1.Early predictive value of pre-treatment tear inflammatory factor levels in patients with dry eye
Yingxing JIANG ; Yuqiu XU ; Yunyun YANG ; Yu ZHANG
International Eye Science 2026;26(1):157-162
AIM: To investigate the application value of pre-treatment tear inflammatory factor levels in predicting therapeutic efficacy for dry eye patients.METHODS:Prospective controlled observational study. A total of 120 patients with dry eye(240 eyes)admitted to our hospital from November 2022 to March 2024 were included. Before dry eye treatment, the levels of inflammatory factors, including interlukin-4(IL-4), IL-6, IL-8, IL-10, IL-12, IL-13, IL-15, IL-18, IL-1β, interferon-γ(IFN-γ), tumor necrosis factor-α(TNF-α), granulocyte-colony stimulating factor(G-CSF), granulocyte-macrophage colony-stimulating factor(GM-CSF), monocyte chemoattractant protein-1(MCP-1)in the tear fluid were detected by ELISA. According to the treatment protocol in the Chinese Expert Consensus on the Treatment of Dry Eye(2020), the patients were given treatments, and the related factors affecting the treatment outcomes of dry eye patients were analyzed.RESULTS:After continuous treatment for 4 wk, all the patients completed follow-up, and they were divided into the markedly effective group(60 patients, 120 eyes)and the ineffective group(60 patients, 120 eyes)based on their therapeutic effects. The markedly effective group had significantly lower pre-treatment levels of IL-6, IL-10, IL-18, IL-1β, and TNF-α than the poor efficacy group(all P<0.05). IL-6(OR=0.994), IL-18(OR=0.998), IL-1β(OR=0.933), and TNF-α(OR=0.998)were independently associated with treatment efficacy(all P<0.05). The nomogram model yielded a C-index of 0.971(95% CI: 0.950-0.993), with calibration curves closely aligned to the ideal curve. The model demonstrated significant predictive value for early therapeutic efficacy(sensitivity=96.67%, specificity=71.67%, cutoff=208, AUC=0.866, 95% CI=0.794-0.952, P<0.001).CONCLUSION:The nomogram model constructed based on the levels of inflammatory factors in dry eye patients before treatment can well predict the treatment effect of patients.
2.Advances in polymorphisms of genes associated with oxaliplatin-induced peripheral neurotoxicity
China Pharmacy 2026;37(1):130-136
Peripheral neurotoxicity represents one of the most severe dose-limiting adverse reactions associated with oxaliplatin, with genetic polymorphisms playing a significant role in oxaliplatin-induced peripheral neuropathy (OIPN). OIPN can be categorized as acute or chronic based on onset timing. The former presents clinically as sensory abnormalities or even motor disorders, while the latter presents clinically as limb sensory disorders that persist, numbness or pain in the hands and feet. The transporter genes OCT2, OCTN2, and NHE1 may be implicated in OIPN; drug-metabolizing enzyme gene GSTP1 Ile105Val, DPYD rs1801265, voltage-gated sodium channel (NaV) gene SCN4A rs2302237, SCN9A rs6746030, SCN10A rs12632942, and other associated genes such as HLA-G rs1610696, rs371194629 and CCNH rs2230641, rs3093816 are associated with severe OIPN. Conversely, DNA repair-related gene XRCC1 rs23885, NaV gene SCN9A rs3750904, rs12478318 and rs6754031 are associated with reduced OIPN risk. In the future, the genetic research findings on OIPN can be translated into clinical applications, ultimately achieving individualized precision medicine for patients.
3.Constructing a model of degenerative scoliosis using finite element method:biomechanical analysis in etiology and treatment
Kai HE ; Wenhua XING ; Shengxiang LIU ; Xianming BAI ; Chen ZHOU ; Xu GAO ; Yu QIAO ; Qiang HE ; Zhiyu GAO ; Zhen GUO ; Aruhan BAO ; Chade LI
Chinese Journal of Tissue Engineering Research 2025;29(3):572-578
BACKGROUND:Degenerative scoliosis is defined as a condition that occurs in adulthood with a coronal cobb angle of the spine>10° accompanied by sagittal deformity and rotational subluxation,which often produces symptoms of spinal cord and nerve compression,such as lumbar pain,lower limb pain,numbness,weakness,and neurogenic claudication.The finite element method is a mechanical analysis technique for computer modelling,which can be used for spinal mechanics research by building digital models that can realistically restore the human spine model and design modifications. OBJECTIVE:To review the application of finite element method in the etiology and treatment of degenerative scoliosis. METHODS:The literature databases CNKI,PubMed,and Web of Science were searched for articles on the application of finite element method in degenerative scoliosis published before October 2023.Search terms were"finite element analysis,biomechanics,stress analysis,degenerative scoliosis,adult spinal deformity"in Chinese and English.Fifty-four papers were finally included. RESULTS AND CONCLUSION:(1)The biomechanical findings from the degenerative scoliosis model constructed using the finite element method were identical to those from the in vivo experimental studies,which proves that the finite element method has a high practical value in degenerative scoliosis.(2)The study of the etiology and treatment of degenerative scoliosis by the finite element method is conducive to the prevention of the occurrence of the scoliosis,slowing down the progress of the scoliosis,the development of a more appropriate treatment plan,the reduction of complications,and the promotion of the patients'surgical operation.(3)The finite element method has gradually evolved from a single bony structure to the inclusion of soft tissues such as muscle ligaments,and the small sample content is increasingly unable to meet the research needs.(4)The finite element method has much room for exploration in degenerative scoliosis.
4.Gradient artificial bone repair scaffold regulates skeletal system tissue repair and regeneration
Yu ZHANG ; Ruian XU ; Lei FANG ; Longfei LI ; Shuyan LIU ; Lingxue DING ; Yuexi WANG ; Ziyan GUO ; Feng TIAN ; Jiajia XUE
Chinese Journal of Tissue Engineering Research 2025;29(4):846-855
BACKGROUND:Gradient artificial bone repair scaffolds can mimic unique anatomical features in musculoskeletal tissues,showing great potential for repairing injured musculoskeletal tissues. OBJECTIVE:To review the latest research advances in gradient artificial bone repair scaffolds for tissue engineering in the musculoskeletal system and describe their advantages and fabrication strategies. METHODS:The first author of the article searched the Web of Science and PubMed databases for articles published from 2000 to 2023 with search terms"gradient,bone regeneration,scaffold".Finally,76 papers were analyzed and summarized after the screening. RESULTS AND CONCLUSION:(1)As an important means of efficient and high-quality repair of skeletal system tissues,gradient artificial bone repair scaffolds are currently designed bionically for the natural gradient characteristics of bone tissue,bone-cartilage,and tendon-bone tissue.These scaffolds can mimic the extracellular matrix of native tissues to a certain extent in terms of structure and composition,thus promoting cell adhesion,migration,proliferation,differentiation,and regenerative recovery of damaged tissues to their native state.(2)Advanced manufacturing technology provides more possibilities for gradient artificial bone repair scaffold preparation:Gradient electrospun fiber scaffolds constructed by spatially differentiated fiber arrangement and loading of biologically active substances have been developed;gradient 3D printed scaffolds fabricated by layered stacking,graded porosity,and bio-3D printing technology;gradient hydrogel scaffolds fabricated by in-situ layered injections,simple layer-by-layer stacking,and freeze-drying method;and in addition,there are also scaffolds made by other modalities or multi-method coupling.These scaffolds have demonstrated good biocompatibility in vitro experiments,were able to accelerate tissue regeneration in small animal tests,and were observed to have significantly improved histological structure.(3)The currently developed gradient artificial bone repair scaffolds have problems such as mismatch of gradient scales,unclear material-tissue interactions,and side effects caused by degradation products,which need to be further optimized by combining the strengths of related disciplines and clinical needs in the future.
5.Over 20-year Follow-up Result of Total Knee Arthroplasty for Knee Arthropathy: A Single Center Cohort Study
Yiming XU ; Mingwei HU ; Wei ZHU ; Muyang YU ; Jin LIN ; Jin JIN ; Wenwei QIAN ; Bin FENG ; Xisheng WENG
Medical Journal of Peking Union Medical College Hospital 2025;16(1):35-41
To evaluate long-term survival and clinical outcomes of patients with knee osteo-arthritis undergoing total knee arthroplasty (TKA) through long-term follow-up. This study was based on a previous cohort study that had completed follow-up. We retrospectively collected clinical data of patients with knee arthropathy (including knee osteoarthritis and knee rheumatoid arthritis) who received the first TKA operation in Peking Union Medical College Hospital from 1993 to 2002 and were followed up for more than 20 years, and conducted a unified follow-up on them in November 10, 2024 (the last follow-up). Kaplan-Meier curve was used to evaluate the survival rate. Hospitals for special surgery (HSS) scores and joint range of motion (ROM) were compared before surgery, 10 years after surgery and at the last follow-up to evaluate the clinical efficacy of TKA. Likert scale was used to evaluate patient satisfaction at the last follow-up. A total of 226 patients (246 knees) received their first TKA in Peking Union Medical College Hospital from 1993 to 2002 and were followed up for more than 10 years. Among them, 104 patients (131 knees) were included in the study at the last follow-up, including 21 patients (24 knees) with prosthesis in place, 18 patients (18 knees) who underwent reoperation for various reasons, and 65 patients (89 knees) who died from non-TKA surgical causes. Up to the last follow-up, there were 29 patients (35 knees) with an average follow-up of more than 20 years, and 12 patients (16 knees) completed HSS score, ROM measurement and patient satisfaction evaluation. Kaplan-Meier curve showed that the 10-year, 15-year, 20-year, and 25-year survival rates were 93.6%, 92.4%, 89.8%, and 71.8%, respectively. The HSS score at the last follow-up was lower than that at 10- year postoperative follow-up[(84.69±11.03) scores TKA treatment for knee arthropathy has high long-term prosthesis survival rate, significant improvement of knee joint function and high patient satisfaction.
6.Early Postoperative Safety of Total Hip Arthroplasty in Systemic Lupus Erythematosus Patients
Xingdong YANG ; Muyang YU ; Yiming XU ; Wei ZHU ; Mingwei HU ; Xisheng WENG ; Bin FENG
Medical Journal of Peking Union Medical College Hospital 2025;16(1):42-49
To analyze the occurrence of early complications after total hip arthroplasty (THA) in patients with systemic lupus erythematosus (SLE). The data of patients who underwent THA at Peking Union Medical College Hospital from June 2012 to April 2024 were retrospectively and consecutively collected. The patients were categorized into SLE group and control group based on the presence or absence of SLE. Using propensity score matching, we matched patients in the two groups at a 1∶1 ratio according to gender, age, and surgical side. Subsequently, we compared the clinical characteristics, incidence of major complications within 30 days postoperatively, and allogeneic blood transfusion rates between the two groups. A total of 270 patients in the SLE group who met the inclusion and exclusion criteria were selected. Within 30 days postoperatively, 18 cases (6.67%) experienced major complications, including 2 cases (0.74%) of upper respiratory tract infection, 2 cases (0.74%) of pulmonary infection, 3 cases (1.11%) of urinary tract infection, 2 cases (0.74%) of other systemic infection, 5 cases (1.85%) of poor wound healing, 1 case (0.37%) of wound infection, 1 case (0.37%) of gastrointestinal complications, 1 cases (0.37%) of shock, and 1 case (0.37%) of SLE flare-up. The allogeneic blood transfusion rate was 22.59% (61/270). After propensity score matching, 163 cases from SLE and control groups were included for analysis. (1) Regarding medical complications, compared with control group, SLE group showed significant differences in osteoporosis, respiratory system disorders, gastrointestinal diseases, urinary system disorders, hematologic abnormalities, and secondary or concomitant rheumatic diseases (all The incidence of major complications within 30 days following THA in patients with SLE was significantly higher than that in non-SLE patients, while the rate of allogeneic blood transfusion remained comparable. To ensure the safety of THA surgery for patients with SLE, it is important to optimize the patient's condition and achieve stabilization prior to surgery. Additionally, strict perioperative management must be forced.
7.Relationship between self-management behaviors and time perspective among patients with comorbid diabetes
YU Dandan ; ZHANG Yaping ; XU Huilin ; HE Dandan ; LIANG Tongtong ; YANG Jiali ; LI Jun
Journal of Preventive Medicine 2025;37(2):130-134
Objective:
To examine the relationship between self-management behaviors and time perspective among patients with comorbid diabetes, so as to provide the evidence for improving self-management behaviors among patients with comorbid diabetes.
Methods:
The patients with comorbid diabetes who were registered in the chronic disease health management system of Minhang District, Shanghai Municipality in 2021, followed up regularly, and lived in Meilong Town were recruited. Demographic information and family history of diabetes were collected through questionnaire surveys. Time perspective and self-management behaviors were assessed using the Zimbardo Time Perspective Inventory and Diabetes Self-Management Behavior Scale, respectively. The relationship between self-management behaviors and time perspective was analyzed using a multivariable ordinal logistic regression model.
Results:
A total of 907 patients with comorbid diabetes were enrolled, including 472 males (52.04%) and 435 females (47.96%). There were 652 cases aged 65 years and above, accounting for 71.89%. In terms of the types of time perspective, 280 patients were future-oriented (30.87%), 236 were balanced (26.02%), 162 were sensation-seeking (17.86%), 123 were fatalistic (13.56%), and 106 were negative (11.69%). In terms of the self-management behaviors, 46 patients were good (5.07%), 643 were moderate (70.89%), and 218 were poor (24.04%). Multivariable ordinal logistic regression analysis showed that after adjusting for age, gender, educational level, marital status, occupation status, monthly income, and family history of diabetes, the patients with comorbid diabetes who had a future-oriented time perspective had better self-management behaviors (OR=1.874, 95%CI: 1.204-2.915).
Conclusion
The self-management behaviors among patients with comorbid diabetes are moderate to poor, and patients with a future-oriented time perspective can better engage in self-management behaviors.
8.Efficacy Mechanism of Xianlian Jiedu Prescription Against Colorectal Cancer Recurrence vias Regulating Angiogenesis
Yanru XU ; Lihuiping TAO ; Jingyang QIAN ; Weixing SHEN ; Jiani TAN ; Chengtao YU ; Minmin FAN ; Changliang XU ; Yueyang LAI ; Liu LI ; Dongdong SUN ; Haibo CHENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):79-87
ObjectiveTo explore effect of Xianlian Jiedu prescription on the recurrence of colorectal cancer (CRC) and investigate the related mechanisms. MethodsA postoperative recurrence model was established in 25 Balb/c mice by injecting CT26 cells subcutaneously into the armpit, followed by surgical removal of 99% of the subcutaneous tumor. The mice were randomly divided into model group, low-dose Xianlian Jiedu prescription (XLJDP-L) group (6.45 g·kg-1·d-1), medium-dose Xianlian Jiedu prescription (XLJDP-M) group (12.9 g·kg-1·d-1), high-dose Xianlian Jiedu prescription (XLJDP-H) group (25.8 g·kg-1·d-1), and 5-fluorouracil (5-FU) group (1×10-3 g·kg-1·d-1). The mice were euthanized after 14 days of continuous intervention, and recurrent tumor tissue was harvested. Hematoxylin and eosin (HE) staining was used to observe pathological and morphological changes in the recurrent tumor tissue. Immunohistochemistry (IHC) was employed to assess the expression of proliferating cell nuclear antigen (Ki67), vascular endothelial growth factor (VEGF), and platelet-endothelial cell adhesion molecule (CD31) in recurrent tumor tissue. The Western blot was used to detect the protein expression levels of angiopoietin-2 (ANG-2), VEGF, phosphorylated-protein kinase B (p-Akt), protein kinase B (Akt), phosphorylated-phosphatidylinositol 3-kinase (p-PI3K), and phosphatidylinositol 3-kinase (PI3K) in recurrent tumor tissue. ResultsBefore treatment, there were no statistical differences in tumor volume, tumor weight, and body mass among the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group compared to the model group, indicating model stability. After treatment, compared with those in the model group, the tumor volume and tumor weight in the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group were significantly reduced (P<0.01), showing dose dependency. Meanwhile, there were no significant differences in body weight among the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group compared to the model group. HE staining showed that compared with that in the model group, tumor tissue in the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group had loosely arranged cells, increased intercellular spaces, small and shriveled nuclei, light staining, fewer mitotic figures and atypical nuclei, and increased necrotic areas. IHC showed that compared with those of the model group, the positive rates of Ki67, VEGF, and CD31 in the recurrent tumor tissue of the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group were significantly reduced (P<0.01) in a dose-dependent manner. Western blot results showed that compared with those of the model group, the protein expression levels of ANG-2 and VEGF in the recurrent tumor tissue of the XLJDP-L, XLJDP-M, and XLJDP-H groups and the 5-FU group were significantly downregulated (P<0.05, P<0.01), and the p-Akt/Akt and p-PI3K/PI3K ratios were significantly decreased in a dose-dependent manner (P<0.05, P<0.01). ConclusionXianlian Jiedu prescription significantly inhibits the recurrence of CRC in mice after subcutaneous tumor surgery. The mechanism may involve regulating the PI3K/Akt pathway and downregulating key angiogenic proteins such as ANG-2, VEGF, and CD31.
9.Clinical and Mechanism of Modified Xiaoyaosan and Its Effective Components in Treatment of Thyroid Diseases: A Review
Shanshan LI ; Yu FU ; Dandan WEI ; Fei WANG ; Mengjiao XU ; Ting WANG ; Shuxun YAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):302-310
Thyroid diseases are common clinical endocrine disorders, and their pathogenesis is generally considered to be closely related to genetic predisposition factors, immune system disorders, hormone levels, etc. Xiaoyaosan is widely used in the treatment of various thyroid diseases with excellent effects. This study summarized the relevant literature on the treatment of thyroid diseases with modified Xiaoyaosan prescriptions and their active ingredients from aspects such as theoretical analysis, clinical research, and mechanism research. Theoretical analysis revealed that Xiaoyaosan could not only disperse stagnated liver qi but also replenish deficient spleen Qi, which was consistent with the etiology and pathogenesis of thyroid diseases. Clinical studies found that Xiaoyaosan and its modified prescriptions could be widely used in the treatment of multiple thyroid diseases, such as hyperthyroidism, Hashimoto's thyroiditis, and thyroid nodules. Both the use of modified Xiaoyaosan alone and in combination with medications such as methimazole, propylthiouracil, and euthyrox could effectively improve patients' clinical symptoms. In the mechanism research, this study discovered that the whole formula of Xiaoyaosan and its modified prescriptions could inhibit inflammatory reactions, regulate immune balance, and delay liver damage during the treatment of thyroid diseases. The research on Xiaoyaosan for treating thyroid diseases mainly focused on thyroid cancer, autoimmune thyroiditis, hyperthyroidism, and hypothyroidism. The mechanisms of action mainly involved promoting cell apoptosis, inhibiting cell proliferation and migration, arresting the cell cycle, and regulating thyroid hormone levels. In conclusion, this study systematically combs and summarizes the research status of Xiaoyaosan in treating thyroid diseases through literature retrieval, aiming to provide new perspectives and new ideas for the prevention and treatment of thyroid diseases with traditional Chinese medicine.
10.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.


Result Analysis
Print
Save
E-mail