1.One Health theory and practice in China:history,present and future
Mu-xin CHEN ; Tian TIAN ; Yang HONG ; Jun-hu CHEN ; Jing-shu LIU ; Jian HE ; Xian-fa CHEN ; Qin LI ; Jin-xin ZHENG ; Tie-jian FENG ; Xiao-nong ZHOU
Chinese Journal of Zoonoses 2025;41(5):447-455
This paper summarizes the progress of theoretical research and practice of One Health in China,and discusses the paradigm of One Health governance to improve the prevention and control of infectious diseases in China and the world,and provide an example for the improvement of the public health system.In particular,China has long history to apply the concept of One Health in the national schistosomiasis control programmes and patriotic health campaigns,which were not only focusing on human health,but also emphasizing the sustainable development of animal health and ecological environment.At the same time,the application of tools such as system dynamics model,eDNA technology,One Health economic assessment and global One Health index(GOHI)in the field of disease control and environmental health provides technical support for the concept of One Health.Despite the challenges of practical application of these tools,the One Health concept will play a greater role in providing sustainable solutions for human-animal-environmental health by strengthening interdisciplinary collaboration,improving standardization protocols and promoting inter-national cooperation.
2.The Application Value of Dynamic Monitoring of Serum Thyroid Hormone Levels in Assessing the Condition Changes and Prognosis of Elderly Patients with Sepsis
Jian-jun LIU ; Jia WU ; Xin-hai GAO ; Yi HU
Progress in Modern Biomedicine 2025;25(15):2530-2539
Objective:To explore the application value of dynamic monitoring of serum thyroid hormone(THs)levels in assessing the condition changes and prognosis of elderly patients with sepsis.Methods:Using a retrospective cohort study,a total of 120 elderly critically ill patients hospitalized in the Department of Critical Care Medicine from April 2020 to April 2023 were selected as research subjects,divided into a sepsis group(60 cases)and a non-sepsis group(60 cases).Sepsis patients were further divided into a survival group(43 cases)and a death group(17 cases)based on 28-day survival status.Serum THs,PCT,IL-6,and Lac were measured on the 1st,5th,and 10th days of hospitalization(d1,d5,dl0)for sepsis patients,and the Sequential Organ Failure Assessment(SOFA)score and Acute Physiology and Chronic Health Evaluation Ⅱ(APACHE Ⅱ)score were recorded.The datas of non-sepsis patients were sampled on d1.The incidence of non-thyroidal illness syndrome(NTIS)was statistically analyzed,and the dynamic changes of serum THs among different groups were compared.The correlation between THs and disease severity,as well as the predictive value of THs for 28-day mortality in sepsis,was analyzed.Results:①The incidence of NTIS was 78.33%(94/120),with a significantly higher incidence in sepsis patients(96.67%,58/60)compared to non-sepsis patients(60.00%),with statistical significance(P<0.05).②Compared to non-sepsis patients,sepsis patients had significantly lower levels of TSH,T3,FT3,and T4 on d1,while rT3 was significantly elevated,with statistical significance(P<0.05);the difference in FT4 levels was not statistically significant(P>0.05).Pearson correlation analysis showed that T3 and T4 were negatively correlated with SOFA and APACHE Ⅱ scores(P<0.05),while other THs indicators showed no correlation with SOFA and APACHE Ⅱ scores(P>0.05).ANOVA results indicated that there was no statistically significant difference in T4 levels at the three time points,and its changes showed no obvious linear trend over time(P>0.05);T3 was significantly lower on d1 than on d5 and d10,and showed an increasing trend with longer hospitalization,while SOFA and APACHE Ⅱ scores were significantly higher on d1 than on d5 and d10,showing a decreasing trend with longer hospitalization(all P<0.05).③Compared to the survival group of sepsis patients,the death group had significantly higher levels of PCT on d10,IL-6 on d5 and d10,and Lac on d1,d5,and d10(P<0.05).The death group had significantly lower levels of T3 and T4 on d1,significantly lower levels of TSH,T3,T4,and FT4 on d5,and significantly lower levels of TSH,T3,FT3,T4,and FT4 on d10,with statistical significance(P<0.05).④Logistic regression analysis showed that independent risk factors for 28-day mortality in sepsis patients included T3 on d1 and T3,FT3,T4,FT4,and IL-6 on d10,with statistical significance(P<0.05).ROC curve analysis indicated that serum levels of T3,FT3,T4,and FT4 on d10 had certain predictive value for 28-day mortality in sepsis patients(all P<0.05),with T3,FT3,and FT4 showing good predictive value,and their AUCs were 0.875,0.872,and 0.861,respectively.The combined AUC for predicting 28-day mortality in sepsis patients using T3,FT3,and FT4 on d10 increased to 0.902.Conclusion:The incidence of NTIS was high in elderly sepsis patients,and the serum THs levels and their dynamic changes were closely related to the patients'condition changes.Continuous dynamic monitoring of serum THs levels could help to assess the progression of sepsis,and T3 may serve as an indicator for evaluating the progression and prognosis of sepsis.
3.Bedside transesophageal echocardiography-guided atrial septostomy under extracorporeal membrane oxygenation support
Ang LIU ; Ke WANG ; Fu-jian DUAN ; Wen-ying KANG ; Jun-song GONG ; PINGCUO-YUNDAN ; Chao-wu YAN
Chinese Journal of Interventional Cardiology 2025;33(4):189-194
Objective To investigate the feasibility and safety of bedside transesophageal echocardiography(TEE)-guided atrial septostomy in patients undergoing extracorporeal membrane oxygenation(ECMO)support.Methods Eight patients(2 females and 6 males)who developed pulmonary edema during VA-ECMO treatment between January 2020 and October 2024 were enrolled.All patients underwent bedside TEE-guided atrial septal puncture,followed by gradual balloon dilation using an Inoue balloon(diameter:18-24 mm).The endpoint for dilation was defined as mean left atrial pressure<15 mmHg.Post-procedure evaluation included assessment of the septal defect size,mean left atrial pressure,and improvement in bilateral pulmonary edema.Results The mean age of all 8 patients was(43.50±16.84)years old.Atrial septostomy was successfully performed in all patients.The mean balloon dilation diameter was(22.75±2.68)mm,resulting in a mean septal defect size of(6.31±0.37)mm.The mean left atrial pressure significantly decreased from(26.63±1.77)mmHg pre-procedure to(12.75±1.28)mmHg post-procedure(P<0.001).All patients demonstrated marked improvement in bilateral pulmonary edema,and six patients also showed a significant reduction in the severity of mitral regurgitation following the procedure.No procedure-related complications were observed.Conclusions Bedside TEE-guided atrial septostomy is safe and effective for reducing left heart loading during ECMO support and improving pulmonary edema.
4.Short-term efficacy of 3D-printed artificial vertebral body combined with PEEK-Cage implantation in treatment of ossification of posterior longitudinal ligament of cervical spine
Shao-tong SUN ; Jun LIU ; Ting-yu LIU ; Wei-jian REN
Journal of Regional Anatomy and Operative Surgery 2025;34(4):325-329
Objective To investigate the short-term efficacy of 3D-printed artificial vertebral body combined with PEEK-Cage implantation in anterior cervical surgery for ossification of the posterior longitudinal ligament of the cervical spine(OPLL).Methods The clinical data of 15 patients with OPLL who underwent anterior cervical surgery with 3D-printed artificial vertebral body and PEEK-Cage implantation in the Fifth Department of Orthopaedics,Liaoning Provincial People's Hospital from September 2022 to June 2023 was retrospectively analyzed.The surgical time,intraoperative blood loss,postoperative drainage volume,bed rest time,hospital stay,and surgery-related complications of patients were analyzed.The Japanese Orthopaedic Association(JOA)score and visual analogue scale(VAS)score of patients were counted before surgery,3 days after surgery,1 month after surgery and 6 months after surgery.The changes of Cobb angle of fusion segment of patients were recorded before surgery,3 days after surgery,1 month after surgery and 6 months after surgery.Results All 15 patients successfully completed the surgery.The surgical time was 130 to 160 minutes,with an average of(148.68±10.04)minutes.The intraoperative blood loss was 50 to 200 mL,with an average of(130.0±18.8)mL.The postoperative drainage volume was 220 to 980 mL,with an average of(270.0±24.6)mL.The bed rest time was 3 to 11 days,with an average of(3.6±2.8)days.The hospital stay was 7 to 16 days,with an average of(8.2±2.6)days.All patients'incisions healed in the first stage,and no infection occurred.One patient suffered from dural sac tear during surgery;4 patients had dysphagia after surgery;1 patient suffered from muscle weakness of one limb after surgery;Hematoma formed in the incision of cervical spine in 1 patient 3 days after surgery.At 3 days,1 month,and 6 months after surgery,the Cobb angle,VAS score and JOA score of 3 patients with myeloid symptoms and upper limb root pain were significantly improved compared with those before surgery(P<0.05),and the Cobb angle and JOA score of 12 patients with only myeloid symptoms were significantly improved compared with those before surgery(P<0.05).Conclusion 3D-printed artificial vertebral body combined with PEEK-Cage implantation in anterior cervical surgery is an effective method for the treatment of OPLL,which can significantly relieve patients'pain and improve their dysfunction in a short time,with good stability and fusion effect.
5.Related factors of cognitive impairment in middle-aged and old-aged patients with type 2 diabetes mellitus
Jiayu WANG ; Yangfan CHAI ; Qirun LI ; Jun MA ; Ying GAO ; Wei LIU ; Youyuan HUANG ; Yan ZHANG ; Jia JIA ; Shuyu WANG ; Wenbo WANG ; Liguang DONG ; Anping WANG ; Yingkui SI ; Guilan KONG ; Jian ZHANG ; Junqing ZHANG
Chinese Mental Health Journal 2025;39(1):13-19
Objective:To investigate the related factors of cognitive impairment in middle-aged and old-aged patients with type 2 diabetes mellitus(T2DM).Methods:A total of 970 patients with T2DM(585 middle-aged group and 385 old-aged group)were selected from residents of a large community in Beijing from September to December 2018.The Mini-Mental State Examination(MMSE)was used to assess the cognitive func-tion.Multivariate logistic regression was used to analyze the related factors.Results:The detection rates of cognitive impairment were 12.0%and 13.5%in middle-aged and old-aged patients with T2DM,respectively.Among mid-dle-aged patients with T2DM,work(OR=0.22,95%CI:0.03-0.77)and education at the junior college or un-dergraduate level and above(OR=0.18,95%CI:0.04-0.55)were protective factors for cognitive impair-ment.Myocardial infarction(OR=4.13,95%CI:1.26-13.63)was a risk factor for cognitive impairment.Among old-aged patients with T2DM,drinking tea 1-2 times a week(OR=0.11,95%CI:0.01-0.58)and education at the junior college or undergraduate level and above(OR=0.19,95%CI:0.05-0.54)were protective factors for cognitive impairment.Stroke(OR=3.64,95%CI:1.55-8.39)and good sleep self-assessment(OR=2.75,95%CI:1.13-7.35)were risk factors for cognitive impairment.Conclusion:Cognitive impairment in middle-aged pa-tients with T2DM is related to work,education level and myocardial infarction,and cognitive impairment in old-aged patients with T2DM is related to lifestyle,education level and stroke.
6.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
7.Risk analysis for coil adverse events based on FDA MAUDE database
Jian-wei YANG ; Lin HUANG ; Yu-juan ZHAO ; Yi XUAN ; Jian-jun CAO ; Chang-qing LIU ; Hui-fang NIU ; Xia LI
Chinese Medical Equipment Journal 2025;46(6):83-87
The coil adverse events in the U.S.Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database from January 2021 to June 2024 were analyzed retrospectively.The risks of coils during the clinical application and their causes were explored with hospital survey and expert demonstration in Shandong Province.Some improving measures were put forward for the safe use of coils,including implementing the main responsibility of the registrant,enhancing the professional skills of the using institutions and strengthening the supervision of the supervisory authorities.[Chinese Medical Equipment Journal,2025,46(6):83-87]
8.One Health theory and practice in China:history,present and future
Mu-xin CHEN ; Tian TIAN ; Yang HONG ; Jun-hu CHEN ; Jing-shu LIU ; Jian HE ; Xian-fa CHEN ; Qin LI ; Jin-xin ZHENG ; Tie-jian FENG ; Xiao-nong ZHOU
Chinese Journal of Zoonoses 2025;41(5):447-455
This paper summarizes the progress of theoretical research and practice of One Health in China,and discusses the paradigm of One Health governance to improve the prevention and control of infectious diseases in China and the world,and provide an example for the improvement of the public health system.In particular,China has long history to apply the concept of One Health in the national schistosomiasis control programmes and patriotic health campaigns,which were not only focusing on human health,but also emphasizing the sustainable development of animal health and ecological environment.At the same time,the application of tools such as system dynamics model,eDNA technology,One Health economic assessment and global One Health index(GOHI)in the field of disease control and environmental health provides technical support for the concept of One Health.Despite the challenges of practical application of these tools,the One Health concept will play a greater role in providing sustainable solutions for human-animal-environmental health by strengthening interdisciplinary collaboration,improving standardization protocols and promoting inter-national cooperation.
9.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
10.Risk analysis for coil adverse events based on FDA MAUDE database
Jian-wei YANG ; Lin HUANG ; Yu-juan ZHAO ; Yi XUAN ; Jian-jun CAO ; Chang-qing LIU ; Hui-fang NIU ; Xia LI
Chinese Medical Equipment Journal 2025;46(6):83-87
The coil adverse events in the U.S.Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database from January 2021 to June 2024 were analyzed retrospectively.The risks of coils during the clinical application and their causes were explored with hospital survey and expert demonstration in Shandong Province.Some improving measures were put forward for the safe use of coils,including implementing the main responsibility of the registrant,enhancing the professional skills of the using institutions and strengthening the supervision of the supervisory authorities.[Chinese Medical Equipment Journal,2025,46(6):83-87]

Result Analysis
Print
Save
E-mail