1.Versatile, low-cost ophthalmic wet lab device to improve diagnostic and surgical eye training
Umar Mardianto ; Andi Arus Victor ; Prasandhya Astagiri Yusuf ; Vetnizah Juniantito ; Aria Kekalih ; Tri Rahayu ; Alhadi Bustamam ; Lukman Edwar
Medical Journal of Indonesia 2026;35(1):76-80
Ophthalmologists rely on wet lab training for both diagnostic procedures and surgical techniques. Existing wet lab devices are limited to surgical training and lack functionality for performing required perioperative diagnostic examinations. This study aimed to develop an affordable, easily manufactured eye holder to enhance ophthalmology training for wet lab simulations. A three-dimensional (3D)-printed animal eye holder was designed in 3D with a funnel-shaped structure resembling an orbital eye socket. The design was optimized for optimal wet lab activities. The animal eye holder device demonstrated potential use for ultrasound biometry, handheld keratometry, tonometry, and ophthalmological surgical training. These activities can be performed effectively after the animals’ eyes are stabilized inside the holder in flat and inclined positions. This innovative animal eye holder is the first designed to provide flexible diagnostic practice and surgical training, especially during wet lab activities.
3D printing
;
cataract
;
device
;
glaucoma
;
ophthalmologic surgical procedures
2.Finite Element Simulation Analysis of a Nickel-Titanium Alloy Patent Foramen Ovale Occluder.
Chinese Journal of Medical Instrumentation 2025;49(2):119-124
In this paper, a preliminary stress/strain analysis of the design structure of a nickel-titanium alloy patent foramen ovale occluder is conducted with the finite element simulation analysis method. In the analysis, solid structure modeling is carried out on three different specifications of domestic patent foramen ovale occluders. Referring to the test method of fatigue performance in inspection standard YY/T 1553-2017, an initial installation deformation is applied to the model, and then the fatigue displacement of 2 mm is applied to the sample to make the model fatigue deformation. The fatigue safety factors of each type of occluder are obtained by strain simulation analysis. The results indicate that the minimum fatigue safety factors of the three specifications of domestic patent foramen ovale occluders are 2.09, 2.35 and 2.06 respectively, which all meet the design of fatigue safety factor greater than 1. Among them, 1818 and 3030 specifications of patent foramen ovale occluders have close values in minimum fatigue safety factors, and both are lower than that of 1825 model. Therefore, it is recommended to carry out physical fatigue tests on both 1818 and 3030 specifications to further verify the fatigue performance of the products.
Finite Element Analysis
;
Titanium
;
Nickel
;
Alloys
;
Foramen Ovale, Patent
;
Materials Testing
;
Septal Occluder Device
;
Stress, Mechanical
3.Discussion on Registration Evaluation Concerns of Embolic Microsphere Devices.
Xiangmei ZHANG ; Yidan ZHANG ; Xiaoqi LIAN
Chinese Journal of Medical Instrumentation 2025;49(2):224-229
The structural characteristics and clinical application of embolic microspheres were summarized in this paper. According to evaluation experience and current regulatory registration evaluation requirements, registration evaluation concerns on embolic microsphere as medical device were analyzed from four aspects: administration attributes, product description, non-clinical studies and clinical evaluation, in order to provide references for the development and registration application of such products and improve the efficiency of registration application.
Microspheres
;
Device Approval
;
Embolization, Therapeutic/instrumentation*
4.Research on Application of Medical Device Real-World Evidence in Regulatory Decisions of the United States.
Xiaofang GU ; Yuanyuan HOU ; Kai LIN ; Juenan PAN
Chinese Journal of Medical Instrumentation 2025;49(4):460-465
In recent years, with the development of big data application technology, the real-world data and the corresponding generated real-world evidence have attracted the attention of healthcare regulatory authorities around the world. Regulators recognize that real-world research with specific purposes using real-world data can provide important evidence for regulatory decisions. A total of 90 instances of publicly released on the application of real-world evidence to support regulatory decisions of U. S. Food and Drug Administration are explored, and the positioning and value of real-world evidence in U. S. Food and Drug Administration regulatory decisions are summarized and analyzed, providing references for the use of real-world data and real-world evidence to promote medical devices whole cycle regulation in China.
United States
;
United States Food and Drug Administration
;
Equipment and Supplies
;
Device Approval
;
China
5.Innovation and development of stent retrievers in acute ischemic stroke.
Nan ZHANG ; Hongye XU ; Hongjian ZHANG ; Hongyu MA ; Weilong HUA ; Minghao SONG ; Yongxin ZHANG ; Jianmin LIU ; Lei ZHANG ; Xiaoxi ZHANG ; Pengfei YANG
Frontiers of Medicine 2025;19(5):789-806
Acute ischemic stroke (AIS) is a cerebrovascular disease characterized by high morbidity, disability, and mortality, posing a significant threat to human health. Endovascular treatment has now been established as a key method for AIS management, in which stent retrievers that can mechanically remove blood clots play a key role in this technique. In recent years, stent retrievers have evolved in complexity and functionality to improve the ability of clot removing and surgical safety. However, the present instruments still have limitations on treatment efficiency, vascular adaptability, and operational precision, posing an urgent need for innovation in the design of stent retrievers. This paper systematically reviewed the structural features and working principles of AIS stent retrievers from the perspective of efficacy evaluation metrics, historical development, recent advancements in stent retrieval technology, and future prospects.
Humans
;
Ischemic Stroke/surgery*
;
Stents
;
Endovascular Procedures/methods*
;
Thrombectomy/methods*
;
Device Removal/methods*
8.Medical device development from ideation to regulation and technology transfer in low- and middle-income countries
Roxanne P. De Leon ; Lourdes Marie S. Tejero
Acta Medica Philippina 2023;57(6):70-76
Necessity motivates innovators in low- to middle-income countries (LMICs) to develop medical devices that solve unmet local health needs. At the start of each process, multidisciplinary teams incubate ideas. Design planning and validation require funding, infrastructure, procurement, and testing. Ultimately, the regulatory and technology transfer processes usher the technology to market. These stages are standard procedures in developed nations; in an LMIC, these present a new set of hurdles to overcome. To assist innovators, this paper describes the hurdles from ideation to regulation and technology transfer and delineates mechanisms to address them.
medical device
;
health technology
;
technology transfer
9.A Brief Discussion on the in Vitro Diagnostic Reagent Inspection Practice of Self-examination Management Regulations for Medical Device Registration.
Ting HE ; Shuang CHU ; Jing XIE
Chinese Journal of Medical Instrumentation 2023;47(3):324-327
On October 21, 2021, the National Medical Products Administration issued and implemented the Self-examination Management Regulations for Medical Device Registration. The regulations clarify the specific requirements of the registration applicants in the process of self-examination, and put forward detailed requirements from the aspects of self-examination ability, self-examination report, declaration materials and responsibility requirements, so as to ensure the orderly development of the self-examination of medical device registration. Based on the actual verification work of in vitro diagnostic reagent, this study briefly discussed the understanding of the relevant contents of the regulations, aiming to provide some reference for enterprises and related supervision departments that have the requirement of registered self-examination.
Medical Device Legislation
;
Reagent Kits, Diagnostic/standards*
10.Feasibility and acceptability of an electronic mobile device application among physicians from the private sector for reporting cases to the national TB program
Jemelyn U. Garcia, MD ; Arthur Dessi E. Roman, MD ; Mari Rose A. De Los Reyes, MD
Philippine Journal of Internal Medicine 2023;61(1):6-10
Introduction:
In the 2016 National TB Prevalence Survey, the prevalence-to-notification ratio for smear-positive pulmonary
tuberculosis was 3.1. In the TB registry, 94% of cases were reported by public providers, suggesting insufficient reporting from private physicians. This study describes the feasibility and acceptability of an electronic mobile device application for possible use among private physicians for reporting their TB cases.
Methods:
This interventional, pre-, and post-test study uses an electronic mobile device application to report TB cases. Using the application, physicians collected and uploaded specific information for reporting cases. The participants were duly-licensed physicians and board certified in any of the following: Internal Medicine, Adult Infectious Diseases, Adult Pulmonology, Pediatrics, Pediatric Infectious Diseases, or Pediatric Pulmonology. The participants used an electronic mobile device application for reporting TB cases. Feasibility and acceptability were assessed using a questionnaire and through a focus group discussion. Data were summarized with mean and standard deviation for continuous variables and proportions for categorical variables.
Results:
The study was conducted at the Research Institute for Tropical Medicine, a government hospital with a Tuberculosis Directly Observed Treatment Short-Course (TB DOTS) facility. Of the 30 physicians invited to participate, 24 provided consent, but only 15 downloaded the application (age range 34-61, mean 39 years, 11 females). Eleven of 15 physicians (73%) assessed the mobile application as easy to navigate and felt that information encoded was relevant to patient care. However, the internet connection affected the speed of the application. The physicians said they had no time, were too busy, or simply forgot to encode patient data.
Conclusion
The use of the application is acceptable but not feasible for use by private physicians. Modification to the application may be done to improve uptake by private physicians.
tuberculosis
;
case reporting
;
digital mobile device


Result Analysis
Print
Save
E-mail