1.Intra-articular injection of different concentrations of silicon-based bioceramics in treatment of knee osteoarthritis in rats
Jingwen GUO ; Qingwei WANG ; Zijun HE ; Zihang HU ; Zhi CHEN ; Rong ZHU ; Yuming WANG ; Wenfei LIU ; Qinglu LUO
Chinese Journal of Tissue Engineering Research 2026;30(2):288-295
BACKGROUND:Currently,treatment method for knee osteoarthritis includes oral medicine,joint cavity drug injection,and physiotherapy,but the curative effect is limited.Existing studies have confirmed that silicon-based bioceramics can promote cartilage and subchondral bone repair and vascular regeneration.OBJECTIVE:To explore the effect of different concentrations of silicon-based bioceramics injected into the knee joint cavity in the treatment of knee osteoarthritis in rats.METHODS:Silicon-based bioceramics-calcium silicate was prepared.Twenty-five SD rats were randomly divided into five groups,with five rats in each group.The healthy group did not receive any intervention,and the modeling group,low-dose calcium silicate group,high-dose calcium silicate group,and saline group used anterior cruciate ligament transection to establish bilateral knee osteoarthritis models.Four weeks after modeling,0.05 mL of 50 and 100 mg/mL calcium silicate solution were injected into the knee joint cavity in the low-dose calcium silicate group and high-dose calcium silicate group,respectively,and 0.05 mL of saline was injected into the knee joint cavity in the saline group,once a week for 4 consecutive weeks.In the fifth week of administration,bilateral knee joint Micro-CT detection,knee joint cartilage hematoxylin-eosin staining,and modified Mankin score were performed.RESULTS AND CONCLUSION:(1)Micro-CT quantitative analysis showed that compared with the healthy group,the volume fraction and number of trabeculae of the medial tibial plateau in the modeling group decreased(P<0.05),and the separation of trabeculae increased(P<0.05).Compared with the modeling group,the volume fraction and number of trabeculae of the medial tibial plateau in the low-dose calcium silicate group and the saline group increased(P<0.05),and the separation of trabeculae decreased(P<0.05).(2)Hematoxylin-eosin staining showed that the cartilage surface of the healthy group and the low-dose calcium silicate group was relatively smooth and flat,the chondrocytes were evenly distributed,without clustered chondrocytes,the tide line was complete,and the staining was uniform;the cartilage surface of the high-dose calcium silicate group was slightly uneven,the middle and deep cells were disordered,with a small number of clustered chondrocytes,the tide line was discontinuous,and the staining was uneven;the cartilage surface of the saline group and the modeling group was obviously rough,the cells were disordered,with a large number of clustered chondrocytes,the tide line disappeared,and the staining was uneven.The modified Mankin score of the healthy group was lower than that of the high-dose calcium silicate group,the saline group,and the modeling group(P<0.05).The modified Mankin score of the high-dose calcium silicate group and the low-dose calcium silicate group was lower than that of the saline group and the modeling group(P<0.05).(3)The results show that calcium silicate knee joint injection has a certain effect in the treatment of knee osteoarthritis.Compared with 100 mg/mL calcium silicate solution,50 mg/mL calcium silicate solution can promote the recovery of subchondral bone and cartilage.
2.Intra-articular injection of different concentrations of silicon-based bioceramics in treatment of knee osteoarthritis in rats
Jingwen GUO ; Qingwei WANG ; Zijun HE ; Zihang HU ; Zhi CHEN ; Rong ZHU ; Yuming WANG ; Wenfei LIU ; Qinglu LUO
Chinese Journal of Tissue Engineering Research 2026;30(2):288-295
BACKGROUND:Currently,treatment method for knee osteoarthritis includes oral medicine,joint cavity drug injection,and physiotherapy,but the curative effect is limited.Existing studies have confirmed that silicon-based bioceramics can promote cartilage and subchondral bone repair and vascular regeneration.OBJECTIVE:To explore the effect of different concentrations of silicon-based bioceramics injected into the knee joint cavity in the treatment of knee osteoarthritis in rats.METHODS:Silicon-based bioceramics-calcium silicate was prepared.Twenty-five SD rats were randomly divided into five groups,with five rats in each group.The healthy group did not receive any intervention,and the modeling group,low-dose calcium silicate group,high-dose calcium silicate group,and saline group used anterior cruciate ligament transection to establish bilateral knee osteoarthritis models.Four weeks after modeling,0.05 mL of 50 and 100 mg/mL calcium silicate solution were injected into the knee joint cavity in the low-dose calcium silicate group and high-dose calcium silicate group,respectively,and 0.05 mL of saline was injected into the knee joint cavity in the saline group,once a week for 4 consecutive weeks.In the fifth week of administration,bilateral knee joint Micro-CT detection,knee joint cartilage hematoxylin-eosin staining,and modified Mankin score were performed.RESULTS AND CONCLUSION:(1)Micro-CT quantitative analysis showed that compared with the healthy group,the volume fraction and number of trabeculae of the medial tibial plateau in the modeling group decreased(P<0.05),and the separation of trabeculae increased(P<0.05).Compared with the modeling group,the volume fraction and number of trabeculae of the medial tibial plateau in the low-dose calcium silicate group and the saline group increased(P<0.05),and the separation of trabeculae decreased(P<0.05).(2)Hematoxylin-eosin staining showed that the cartilage surface of the healthy group and the low-dose calcium silicate group was relatively smooth and flat,the chondrocytes were evenly distributed,without clustered chondrocytes,the tide line was complete,and the staining was uniform;the cartilage surface of the high-dose calcium silicate group was slightly uneven,the middle and deep cells were disordered,with a small number of clustered chondrocytes,the tide line was discontinuous,and the staining was uneven;the cartilage surface of the saline group and the modeling group was obviously rough,the cells were disordered,with a large number of clustered chondrocytes,the tide line disappeared,and the staining was uneven.The modified Mankin score of the healthy group was lower than that of the high-dose calcium silicate group,the saline group,and the modeling group(P<0.05).The modified Mankin score of the high-dose calcium silicate group and the low-dose calcium silicate group was lower than that of the saline group and the modeling group(P<0.05).(3)The results show that calcium silicate knee joint injection has a certain effect in the treatment of knee osteoarthritis.Compared with 100 mg/mL calcium silicate solution,50 mg/mL calcium silicate solution can promote the recovery of subchondral bone and cartilage.
3.STAR Guideline Terminology(Ⅲ):Reporting,Evaluation,Dissemination,Implementation and Updating
Hongfeng HE ; Hui LIU ; Qianling SHI ; Yuanyuan YAO ; Yishan QIN ; Zijun WANG ; Jinhui TIAN ; Long GE ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(4):1018-1025
Objective To sort,summarize,and introduce key terms related to guideline reporting,evaluation,dissemination,implementation,and updating.Methods We systematically searched guideline de-velopment manuals and methodological literature from database inception to October 25,2024.Terms related to guideline reporting,updating,evaluation,and implementation were extracted,standardized,and finalized through a structured consensus process.Results A total of 13 guideline manuals and 32 methodological articles were included,yielding 14 core terms with standardized definitions.Conclusions This article introduces key terms such as reporting standards,external review,and research gaps across guideline development phases to promote concept application and deepen readers'understanding of guideline development.
4.Clinical features and prognosis of acute B lymphoblastic leukemia children carrying a TCF3: : PBX1 fusion gene
Lulu HUANG ; Yunyan HE ; Yang LI ; Danna LIN ; Ning LIAO ; Yayun LING ; Lyuhong XU ; Xinyu LI ; Huirong MAI ; Ying WANG ; Wuqing WAN ; Ying LIU ; Yanlai TANG ; Xiaoli ZHANG ; Chuan TIAN ; Xiaofeng LI ; Qiwen CHEN ; Xingjiang LONG ; Liuhua LIAO ; Qiaoru LI ; Jianling CAI ; Zijun ZHEN ; Zhiguang LI ; Keyan YANG ; Qinlong ZHENG ; Lihua YANG
Chinese Journal of Applied Clinical Pediatrics 2025;40(7):497-502
Objective:To analyze the clinical features and prognosis of acute B lymphoblastic leukemia (B-ALL) children carrying a TCF3: : PBX1 fusion gene and to evaluate the prognostic value of this gene.Methods:Retrospective cohort study.A total of 2 164 B-ALL children aged 0-18 years diagnosed and treated at 19 pediatric centers from October 2016 to June 2022 were enrolled.They were divided into the positive group and the negative group according to whether they carried a TCF3: : PBX1 fusion gene.The clinical characteristics, treatment response, adverse reactions, and prognosis of the 2 groups of patients were analyzed.The rank sum and Kruskal-Wallis tests were used to compare two and more than two groups of numerical variables, respectively.Fisher′s exact test was used to compare categorical variables.Results:Among the 2 164 patients, 116 (5.4%) were TCF3: : PBX1 positive, of which 70 patients were female, accounting for 60.3%.There were 840 female patients in the TCF3: : PBX1-negative group, accounting for 41.0%.There was a significant difference in the ratio of females between the TCF3: : PBX1-positive and TCF3: : PBX1-negative groups ( P<0.001).No significant difference was observed in age of onset between the two groups( P>0.05).The proportion of bone marrow naive cells [54.00 (14.00, 76.50)% vs.29.00 (3.00, 68.00)%], white blood cell counts [25.30 (10.46, 60.94)×10 9/L vs.9.03 (4.38, 30.73)×10 9/L] and hemoglobin counts [82.00(63.00, 101.00) g/L vs.74.00(60.00, 90.00) g/L] in the TCF3: : PBX1-positive group were significantly higher than those in the negative group at the onset (all P<0.05).In terms of treatment response, the proportion of peripheral blood naive cells on Day 8 in the TCF3: : PBX1-positive group was significantly higher than that in the negative group [2.00 (0, 9.00)% vs.0 (0, 2.00)%, P<0.001].The proportion of minimal residual disease <0.1% on Day 15 in the TCF3: : PBX1-positive group was significantly higher than that in the negative group ( P=0.038).There were no significant differences in cumulative recurrence rate, treatment-related mortality (TRM), and overall survival (OS) between the TCF3: : PBX1-positive group and TCF3: : PBX1-negative group (all P>0.05).The cumulative recurrence risk of TCF3: : PBX1-positive patients was 9.646 times higher than that of ETV6: : RUNX1-positive patients with better prognosis( HR=9.646, 95% CI: 1.026-90.700, P=0.047).There were no significant differences in TRM and OS between TCF3: : PBX1-positive and ETV6: : RUNX1-positive patients (all P>0.05).A significant enrichment of PAX5 mutations was detected in TCF3: : PBX1-positive patients.Among the 7 high-risk TCF3: : PBX1-positive patients in a single center, 4 patients had PAX5 mutations, and this proportion was significantly higher than that in other patients ( P<0.001). Conclusions:B-ALL children carrying a TCF3: : PBX1 fusion gene have a high remission rate and good long-term prognosis after intensive chemotherapy.It is suggesting that TCF3: : PBX1-positive B-ALL patients should be rated at intermediate risk to receive intensive chemotherapy.
5.Clinical features and prognosis of acute B lymphoblastic leukemia children carrying a TCF3: : PBX1 fusion gene
Lulu HUANG ; Yunyan HE ; Yang LI ; Danna LIN ; Ning LIAO ; Yayun LING ; Lyuhong XU ; Xinyu LI ; Huirong MAI ; Ying WANG ; Wuqing WAN ; Ying LIU ; Yanlai TANG ; Xiaoli ZHANG ; Chuan TIAN ; Xiaofeng LI ; Qiwen CHEN ; Xingjiang LONG ; Liuhua LIAO ; Qiaoru LI ; Jianling CAI ; Zijun ZHEN ; Zhiguang LI ; Keyan YANG ; Qinlong ZHENG ; Lihua YANG
Chinese Journal of Applied Clinical Pediatrics 2025;40(7):497-502
Objective:To analyze the clinical features and prognosis of acute B lymphoblastic leukemia (B-ALL) children carrying a TCF3: : PBX1 fusion gene and to evaluate the prognostic value of this gene.Methods:Retrospective cohort study.A total of 2 164 B-ALL children aged 0-18 years diagnosed and treated at 19 pediatric centers from October 2016 to June 2022 were enrolled.They were divided into the positive group and the negative group according to whether they carried a TCF3: : PBX1 fusion gene.The clinical characteristics, treatment response, adverse reactions, and prognosis of the 2 groups of patients were analyzed.The rank sum and Kruskal-Wallis tests were used to compare two and more than two groups of numerical variables, respectively.Fisher′s exact test was used to compare categorical variables.Results:Among the 2 164 patients, 116 (5.4%) were TCF3: : PBX1 positive, of which 70 patients were female, accounting for 60.3%.There were 840 female patients in the TCF3: : PBX1-negative group, accounting for 41.0%.There was a significant difference in the ratio of females between the TCF3: : PBX1-positive and TCF3: : PBX1-negative groups ( P<0.001).No significant difference was observed in age of onset between the two groups( P>0.05).The proportion of bone marrow naive cells [54.00 (14.00, 76.50)% vs.29.00 (3.00, 68.00)%], white blood cell counts [25.30 (10.46, 60.94)×10 9/L vs.9.03 (4.38, 30.73)×10 9/L] and hemoglobin counts [82.00(63.00, 101.00) g/L vs.74.00(60.00, 90.00) g/L] in the TCF3: : PBX1-positive group were significantly higher than those in the negative group at the onset (all P<0.05).In terms of treatment response, the proportion of peripheral blood naive cells on Day 8 in the TCF3: : PBX1-positive group was significantly higher than that in the negative group [2.00 (0, 9.00)% vs.0 (0, 2.00)%, P<0.001].The proportion of minimal residual disease <0.1% on Day 15 in the TCF3: : PBX1-positive group was significantly higher than that in the negative group ( P=0.038).There were no significant differences in cumulative recurrence rate, treatment-related mortality (TRM), and overall survival (OS) between the TCF3: : PBX1-positive group and TCF3: : PBX1-negative group (all P>0.05).The cumulative recurrence risk of TCF3: : PBX1-positive patients was 9.646 times higher than that of ETV6: : RUNX1-positive patients with better prognosis( HR=9.646, 95% CI: 1.026-90.700, P=0.047).There were no significant differences in TRM and OS between TCF3: : PBX1-positive and ETV6: : RUNX1-positive patients (all P>0.05).A significant enrichment of PAX5 mutations was detected in TCF3: : PBX1-positive patients.Among the 7 high-risk TCF3: : PBX1-positive patients in a single center, 4 patients had PAX5 mutations, and this proportion was significantly higher than that in other patients ( P<0.001). Conclusions:B-ALL children carrying a TCF3: : PBX1 fusion gene have a high remission rate and good long-term prognosis after intensive chemotherapy.It is suggesting that TCF3: : PBX1-positive B-ALL patients should be rated at intermediate risk to receive intensive chemotherapy.
6.Design and verification of inspection system for quality of human body metabolic tester based on alcohol combustion mode
Wei CAO ; Chendong LI ; Youcai WANG ; Yanyan CHEN ; Zijun HE
China Medical Equipment 2025;22(9):36-40
Objective:To design an inspection system for quality of metabolism tester based on alcohol combustion mode for human body,so as to realize assessment for accuracy degree of human metabolism tester.Methods:According to the specific indicators that were measured by the metabolism tester for human body,a simulation of bidirectional controllable flow and a simulation of component concentration of exhaled breath were designed and realized.Then,the ratio of alcohol consumption to oxygen consumption and carbon dioxide production were calculated by the formula of alcohol combustion.Finally,the metabolic indexes(volume of gas flow,oxygen consumption,dioxide carbon production,rate of energy metabolism,respiratory quotient)that were outputted by the inspection system for quality were calculated according to Weir formula.Furthermore,the verification for precision of simulation modules of exhale and inhalation,and weighing device module was carried out,and an application test of inspection system for quality was also carried out.Results:The errors of the volume of gas flow and alcohol consumption that were outputted by simulation modules of exhale and inhalation,and weighing device module were all within±1%,and the errors between the reference value of the metabolic index of the inspection system for quality and the actually measured value of the metabolic index of the hood calorimeter were all within 10%.Conclusion:There was higher consistency between inspection system for quality of metabolism tester for human body and the actual measurement data of calorimeter,which can better simulate the process of respiratory metabolism of human body,and provide standardized testing means for the performance verification of metabolic tester.
7.STAR Guideline Terminology(Ⅱ): Clinical Question Formulation, Evidence Retrieval and Appraisal, and Recommendation Development
Di ZHU ; Haodong LI ; Zijun WANG ; Qianling SHI ; Hui LIU ; Yishan QIN ; Yuanyuan YAO ; Zhewei LI ; Hongfeng HE ; Jinhui TIAN ; Long GE ; Yaolong CHEN ;
Medical Journal of Peking Union Medical College Hospital 2025;16(3):756-764
To introduce and analyze guideline terminology related to clinical question formulation, evidence retrieval and appraisal, and recommendation development. A systematic search was conducted in guideline development manuals and relevant methodological literature, covering publications up to October 25, 2024. Terminology related to the three aforementioned stages of related to guideline development was extracted from the included literature, standardized, and refined through consensus meetings to finalize a comprehensive terminology list and definitions. A total of 30 guideline development manuals and 15 methodological articles were included, and 23 core terms were identified. It is recommended to develop a standardized and scientifically sound guideline terminology system with unified naming, clear definitions, and alignment with the linguistic environment and usage habits in China. At the same time, it is essential to strengthen terminology training for both guideline developers and users based on this system, in order to deepen their correct understanding and proper application of guideline terminology.
8.Development and application of telepsychiatry
Zijun PAN ; Jiali HE ; Xiaoran WANG ; Yonghai BAI
Academic Journal of Naval Medical University 2025;46(10):1355-1362
Telepsychiatry,as an innovative healthcare model that utilizes remote communication technology for the diagnosis,treatment,counseling,and management of mental illnesses,not only has seen rapid development during the coronavirus disease 2019 pandemic,but also has played a crucial role in alleviating the global shortage of mental health resources.In recent years,with the rapid advancement of digital technology,emerging technologies such as artificial intelligence,virtual reality,and wearable digital health devices have demonstrated broad application prospects in the field of telepsychiatry.This article systematically reviews the relevant literatures on telepsychiatry,delving into its concepts,major tools,and clinical applications,providing insights for researchers and decision-makers in the field,and ultimately promoting the widespread adoption of telepsychiatry.
9.Design and Verification of a Human Energy Metabolism Detection System Based on Breath-by-Breath Method.
Chendong LI ; Wei FANG ; Youcai WANG ; Yanyan CHEN ; Wei CAO ; Jun XU ; Yuyang WANG ; Fei YANG ; Zijun HE ; Yining SUN
Chinese Journal of Medical Instrumentation 2025;49(2):197-203
OBJECTIVE:
To accurately measure human energy metabolism with high temporal resolution, a respiratory gas analysis system was designed using a breath-by-breath approach.
METHODS:
Firstly, indirect calorimetry was employed in respiratory gas analysis to measure the respiratory flow and concentration signals in real-time. Secondly, oxygen consumption
Humans
;
Energy Metabolism
;
Breath Tests/instrumentation*
;
Calorimetry, Indirect/instrumentation*
;
Equipment Design
10.Design and verification of inspection system for quality of human body metabolic tester based on alcohol combustion mode
Wei CAO ; Chendong LI ; Youcai WANG ; Yanyan CHEN ; Zijun HE
China Medical Equipment 2025;22(9):36-40
Objective:To design an inspection system for quality of metabolism tester based on alcohol combustion mode for human body,so as to realize assessment for accuracy degree of human metabolism tester.Methods:According to the specific indicators that were measured by the metabolism tester for human body,a simulation of bidirectional controllable flow and a simulation of component concentration of exhaled breath were designed and realized.Then,the ratio of alcohol consumption to oxygen consumption and carbon dioxide production were calculated by the formula of alcohol combustion.Finally,the metabolic indexes(volume of gas flow,oxygen consumption,dioxide carbon production,rate of energy metabolism,respiratory quotient)that were outputted by the inspection system for quality were calculated according to Weir formula.Furthermore,the verification for precision of simulation modules of exhale and inhalation,and weighing device module was carried out,and an application test of inspection system for quality was also carried out.Results:The errors of the volume of gas flow and alcohol consumption that were outputted by simulation modules of exhale and inhalation,and weighing device module were all within±1%,and the errors between the reference value of the metabolic index of the inspection system for quality and the actually measured value of the metabolic index of the hood calorimeter were all within 10%.Conclusion:There was higher consistency between inspection system for quality of metabolism tester for human body and the actual measurement data of calorimeter,which can better simulate the process of respiratory metabolism of human body,and provide standardized testing means for the performance verification of metabolic tester.

Result Analysis
Print
Save
E-mail