1.Impact of body mass index on postoperative complications of open pancreaticoduodenectomy
Yating ZHU ; Yiwei REN ; Zhiquan LIU ; Kunpeng LI ; Ran MIAO ; Xiangui HU ; Liu OUYANG
Chinese Journal of Pancreatology 2024;24(5):350-357
Objective:To investigate the impact of body mass index (BMI) on the postoperative complications of open pancreaticoduodenectomy (OPD).Methods:The preoperative, operative and postoperative data of 234 patients who underwent OPD in the Department of the Hepatobiliary and Pancreatic Surgery of First Affiliated Hospital affiliated to Naval Medical University from January 2015 to June 2016 were analyzed retrospectively. According to the Asian BMI standard, the patients were divided into three groups: underweight group (BMI<18.5 kg/m 2, n=32), normal weight group (18.5 kg/m 2≤BMI<23.0 kg/m 2, n=110) and overweight group (BMI≥23.0 kg/m 2, n=92). Normal weight group was compared with underweight group and overweight group, respectively, to analyze the relationship between BMI and intraoperative parameters and major postoperative complications of OPD. Results:The incidence of diabetes in underweight group was lower than that in normal weight group, and the proportion of ASA score 3 in underweight group was higher than that in normal weight group, and there were significantly statistical differences (both P value <0.05). There was no significant difference on the other variables between underweight group, normal weight group and overweight group. The operation time, intraoperative hemorrhage volume >800 ml and intraoperative blood transfusion rate were not statistically different between underweight group and normal weight group, but overweight group had obviously higher intraoperative blood transfusion rate than normal weight group and the difference was statistically significant ( P<0.05). Underweight group had more postoperative intraperitoneal hemorrhage and postoperative blood transfusion rate than normal weight group, and the readmission rate in underweight group was less than that in normal weight group; the incidence of clinically related-post operative pancreatic fistula, postoperative infection, gastrointestinal bleeding and delayed gastric emptying in overweight group were significantly higher than those in normal weight group, and there were significantly statistical differences (all P value <0.05). In underweight group, normal weight group and overweight group, the average length of hospital stay were 9.9 days, 11.3 days, 15 days, and the total hospitalization expenses were 63663.04 yuan, 66241.78 yuan and 80484.31 yuan, respectively. Conclusions:Compared to normal weight patients, the difficulty of OPD in underweight patients does not increase, while the difficulty of OPD in overweight patients increases. Underweight and overweight could both increase the postoperative complications of OPD to some extent.
2.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
3.Clinicopathological characteristics of secondary trigeminal neuralgia due to cerebellopontine angle tumors
Ying WANG ; Ruijie LIU ; Zhiquan YANG ; Zhuanyi YANG
Journal of Central South University(Medical Sciences) 2024;49(4):588-594
Objective:Cerebellopontine angle(CPA)tumors are a common cause of secondary trigeminal neuralgia(TN),characterized by their concealed location,slow progression,and difficulty in early detection.This study aims to explore the clinicopathological characteristics of patients with secondary TN due to CPA tumors to enhance understanding and management of secondary TN. Methods:A retrospective analysis was conducted on clinical data and pathological results of 116 patients with CPA tumor-related TN treated at Xiangya Hospital of Central South University from January 1,2017 to December 31,2022.The study analyzed the relationship of tumor pathological types with clinical manifestations,tumor location,surgical methods,and treatment outcomes. Results:Among the cases,95.7%(111/116)were benign tumors,3.4%(4/116)were malignant tumors,and 0.9%(1/116)were borderline tumors.Benign tumors were predominantly acoustic neuromas,meningiomas,and schwannomas.Among the patients,46.6%(54/116)presented with isolated TN,while 53.4%(62/116)exhibited other associated symptoms depending on factors such as tumor growth location and rate.The complete resection rate in this group was over 90%,with 41.4%(48/116)of patients undergoing concurrent microvascular decompression after tumor resection,predominantly for schwannomas.The overall effective rate of surgical treatment reached 93.9%,with schwannomas showing higher efficacy rates compared with acoustic neuromas and meningiomas(P<0.05).The recurrence rate of acoustic neuromas was significantly higher than that of meningiomas and schwannomas(P<0.05). Conclusion:CPA tumors are a major cause of secondary TN,predominantly benign,with occasional underdiagnosed malignant tumors.Early diagnosis and treatment significantly impact prognosis.Different tumor types vary in clinical symptoms,surgical approaches,and treatment efficacy.Surgical strategies should balance tumor resection extent and neural function preservation,with microvascular decompression as necessary.
4.Construction of a whole business process supervision and management system: based on management information system of blood banks
Weidong HE ; Zhiquan RONG ; Chen XIAO ; Junlei HUANG ; Na HU ; Xuefeng LIANG ; Liyue JIANG ; Caina LI ; Wei WEI ; Yan LIU
Chinese Journal of Blood Transfusion 2024;37(4):455-461
【Objective】 To achieve supervision and management of the whole business process of blood center, raise productivity and ensure blood quality by enabling blood center managers comprehensively grasp the key business operation situation of the whole process at anytime and anywhere. 【Methods】 A whole business process supervision and management system was established covering background of preparation, business scope, content of position supervision and management, overall framework design, interface design of management and supervision management, physical database design, program development and online debugging, and was integrated with the blood bank management information system. The display and management were through a mobile APP to record key indicators of business process from blood collection to blood supply timely and comprehensively. Statistical analysis was conducted on total collection volume, total preparation volume and total supply volume, as well as discarding rate of test unqualified and of non-test unqualified (lipemic blood excluded) in 2023 and 2022. 【Results】 We established a mobile APP based on a blood bank management information system for business supervision and management of whole process, and achieved management by phones. After its implementation in 2023, the total collection volume, total preparation volume and total supply volume in 2023 were all higher than those in 2022, with growth rates of 5.88% (13 247/225 454 U), 4.73% (24 156/510 698 U), and 6.70% (34 814/519 914 U), respectively. The discarding rate in 2023 was lower than that in 2022 (0.54%, 2 868/534 854 U) vs (0.60%, 3 047/510 698 U) (P<0.01), and the non-test unqualified discarding rate (lipemic blood excluded) in 2023 was significantly lower than that in 2022(0.12%, 649/534 854 U) vs (0.19%, 991/510 698 U)(P<0.01). 【Conclusion】 The construction of supervision and management system of a whole business process based on blood bank management information system can meet the standardized service needs of managers at anytime and anywhere, continuously raise productivity and the standardization and scientific level of blood bank management, thus ensuring blood supply.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Distribution and seasonal fluctuation of visceral leishmaniasis vectors sandflies in Henan Province in 2023
Zhiquan HE ; Dan WANG ; Yuanjing KOU ; Chengyun YANG ; Yiying SUN ; Penghui JI ; Tiantian JIANG ; Deling LU ; Dan QIAN ; Hongwei ZHANG ; Ying LIU
Chinese Journal of Schistosomiasis Control 2024;36(4):346-351
Objective To investigate the geographical distribution and seasonal fluctuations of visceral leishmaniasis vectors sandflies in Henan Province in 2023, so as to provide insights into the prevention and control of visceral leishmaniasis vectors. Methods A total of 23 counties (districts) were sampled from 18 cities of Henan Province from May to September, 2023 as sandfly surveillance sites, and sandflies were captured using human capture and light trapping methods. Following morphological identification, the changes in the sandfly density were calculated at different months and in different breeding habitats. Results A total of 406 light traps were set at sandfly surveillance sites in Henan Province from May to September, 2023, and a total of 3 137 female sandlies were captured, with an average density of 7.73 sandlies/(light·night). A total of 1 494 Phlebotomus chinensis sandflies were captured, including 1 222 female sandflies, with an average density of 3.01 sandflies/(light·night), and the highest density of P. chinensis was found in Gongyi City [17.00 sandflies/(light·night)]. A total of 5 544 sandflies were captured using the human capture method, including 230 P. chinensis, and the density of P. chinensis appeared a unimodal distribution, with a peak in early July [5.81 sandflies/(light·night)]. Among different breeding habitats, the highest P. chinensis density was detected in pigpens [4.50 sandflies/(light·night)]. Conclusions P. chinensis was predominantly distributed in hilly areas of northern and central-western Henan Province in 2023, and the sandfly density appeared a unimodal distribution. Intensified monitoring of visceral leishmaniasis vectors is recommended.
10.Genetic polymorphisms of common sandflies in selected areas of Henan Province based on DNA barcoding
Dan WANG ; Zhiquan HE ; Chengyun YANG ; Deling LU ; Yiying SUN ; Yuanjing KOU ; Dan QIAN ; Hongwei ZHANG ; Ying LIU
Chinese Journal of Schistosomiasis Control 2024;36(4):352-360
Objective To characterize the species of common sandflies in Henan Province using DNA barcoding with cytochrome c oxidase subunit I (COI) gene as the molecular marker, and to analyze the genetic polymorphisms of sandflies, so as to provide insights into visceral leishmaniasis prevention and control in Henan Province. Methods Sandfly specimens were sampled from 13 sandflies surveillance sites from 2021 to 2023 in Anyang City, Zhengzhou, Luoyang and Xuchang cities (Zhengzhou-Luoyang-Xuchang areas) where visceral leishmaniasis cases were reported and in Jiaozuo and Xinxiang cities (Jiaozuo-Xinxiang areas) without visceral leishmaniasis cases reported. Genomic DNA was extracted from a single sandfly, and COI gene was amplified. The amplification product was subjected to bidirectional sequencing. Following sequence assembly, the species of sandflies was characterized through sequence alignment using the BLAST tool. The intra-specific and inter-specific genetic distances of sandflies were estimated among different areas using the software Mega 11, and phylogenetic trees were created. The polymorphisms of nucleotide sequences in the sandflies COI gene were estimated using the software DnaSP. The fixation index (FST) of different geographical isolates of sandflies was calculated using the Arlequin software, and the gene flow value (Nm) was used to measure the gene flow in the sandflies populations. In addition, the population genetic structure of different geographical populations of Phlebotomus chinensis was analyzed using the STRUCTURE software. Results A total of 978 sandflies were collected from 13 sandflies surveillance sites in Zhengzhou-Luoyang-Xuchang areas, Jiaozuo-Xinxiang areas and Anyang City of Henan Province from 2021 to 2023, and 475 sandflies were randomly sampled for subsequent detections. A total of 304 Ph. chinensis, 162 Se. squamirostris and 9 Se. bailyi were identified based on molecular biological detection of the COI gene, and Se. bailyi was reported for the first time in Henan Province. The intraspecific genetic distances of sandflies were 0.000 to 0.040, and the inter-specific genetic distances ranged from 0.133 to 0.161. Phylogenetic analysis revealed that each of the three sandfly species was clustered into a clade. The genetic polymorphisms of Ph. chinensis populations varied among different areas, with the highest haplotype diversity (0.966 ± 0.007) and the greatest nucleotide diversity (0.011) in Zhengzhou-Luoyang-Xuchang areas, and the lowest haplotype diversity (0.720 ± 0.091) and nucleotide diversity (0.004) in Anyang City. The dominant haplotype of Ph. chinensis populations was Pch_Hap_2 in Anyang City and Jiaozuo-Xinxiang areas, with moderate genetic differentiation (0.05 < FST < 0.15) and frequent gene exchange (Nm value > 1) between Ph. chinensis populations sampled from Anyang City, and Jiaozuo-Xinxiang areas. Population genetic structure analysis showed that the dominant component of Ph. chinensis populations was K5 in Anyang City and Jiaozuo-Xinxiang areas. No obvious dominant haplotype was observed in Ph. chinensis populations sampled from Zhengzhou-Luoyang-Xuchang areas, which had very high genetic differentiation (FST > 0.25) and little gene exchange (Nm value < 1) with Ph. chinensis populations from Anyang City, and Jiaozuo-Xinxiang areas, with K3 as the dominant component. In addition, there was no significant difference in the genetic polymorphism level among Se. squamirostris populations from the three areas. Conclusions There are Ph. chinensis, Se. squamirostris and Se. bailyi in Henan Province, and S. bailyi is recorded for the first time in Henan Province by molecular biological assays. There are different levels of genetic differentiation and gene exchange among P. chinensis populations in different areas of Henan Province.

Result Analysis
Print
Save
E-mail