1.Tumor cells targetable graphene oxide doped microneedle for synergistic photothermal-chemotherapy treatment of melanoma.
Zhiqiang ZHANG ; Junfang KE ; Yuxin DAI ; Chenxi FANG ; Yunfeng DAI ; Chen WANG ; Meitao DUAN ; Jungang REN ; Ming CHEN ; Chen WANG
Journal of Pharmaceutical Analysis 2025;15(10):101270-101270
Melanoma is characterized by high malignancy, ranking the third among skin malignancies, and is associated with lack of specific treatment options and poor prognosis. Therefore, the development of effective therapies for melanoma is imperative. A critical challenge in addressing subcutaneous disease lies in overcoming the skin barrier. In this study, we engineered a microneedle (MN) system that integrates chemotherapy, photothermal therapy (PTT), and targeted therapy to enhance anti-tumor efficacy while effectively penetrating the skin barrier. In vitro studies have demonstrated that the MN drug delivery system (DDS) can effectively penetrate the stratum corneum of the skin, deliver therapeutics to subcutaneous tumor sites, and establish a drug reservoir at these locations to exert anti-tumor effects. Cellular experiments indicated that the engineered PTT chemotherapy-targeted MNs can be internalized by tumor cells, exhibiting enhanced cytotoxicity against them. In vivo pharmacological investigations revealed that the combination of PTT and chemotherapy delivered via this MN DDS produced synergistic anti-tumor effects, achieving a tumor inhibition rate of up to 98.15%. This in situ DDS minimizes involvement with other organs, significantly reducing chemotherapy-related side effects. In summary, the PTT chemotherapy-targeted MNs developed in this study demonstrate promising application potential by enhancing anti-tumor efficacy while minimizing adverse effects.
2.Simulation analysis of the protective performance of barium sulfate mortar against positron nuclide γ-rays
Zhiqiang XU ; Huaixin NI ; Jiwu GENG ; Lichun LI ; Zaoqin ZHANG ; Shibiao SU ; Meixia WANG ; Ming LIU
Chinese Journal of Radiological Health 2025;34(2):209-213
Objective To obtain the protective performance parameters of barium sulfate mortar against positron nuclide γ-rays, provide reference data for precise shielding calculations, and guide the design, evaluation, and construction of radiation shielding. Methods The FLUKA program was used to build a model for simulating the dose equivalent rate variation around points of interest under the irradiation of the most commonly used positron nuclide 18F with changes in the thicknesses of lead and barium sulfate mortar. The transmission curves of lead and barium sulfate mortar were fitted, and the half-value layer (HVL) and lead equivalence of barium sulfate mortar were calculated based on the fitted curves. Results The ambient dose equivalent rate coefficient of positron nuclide 18F was 1.339 4×10−1 μSv·m2/MBq·h and the HVL for lead was 4.037 mm, with deviations of 0.043% and 1.53% compared to the values provided in the AAPM Report No. 108, respectively. The HVLs for γ-rays produced by 18F, using barium sulfate mortar with apparent densities of 4.20, 4.00, and 3.90 g/cm3 mixed with 35.2-grade cement in a 4∶1 mass ratio, were 2.914, 2.969, and 3.079 cm, respectively. The lead equivalences were
3.Effect of Linaclotide combined with Simethicone and compound polyethylene glycol electrolyte on cleansing effect of bowel in patients with constipation
Jinwen LIAO ; Wenli SHEN ; Lan WU ; Wenxiu LONG ; Wei ZHAO ; Ming WANG ; Zhiqiang DU
China Journal of Endoscopy 2025;31(6):44-53
Objective To investigate the efficacy and safety of Linaclotide combined with Simethicone oil and compound polyethylene glycol electrolyte(PEG)for cleansing effect of bowel in patients with constipation.Methods A prospective randomized controlled trial was designed and implemented by single blind method.383 patients with constipation who underwent colonoscopy from April 2023 to August 2024 were enrolled and randomly divided into routine group(128 cases),experimental group A(128 cases)and experimental group B(127 cases).Routine group treated with 3 L PEG,experimental group A treated with 290 μg Linaclotide+2 L PEG and experimental group B treated with 290 μg Linaclotide+30 mL Simethicone+2 L PEG.Bowel preparation effect[Boston bowel preparation scale(BBPS)scores and foaming removal effect],lesion detection rate,first defecation interval,frequency of defecation,the success rate of cecal intubation,the insertion time of colonoscopy,the withdrawal time of colonoscopy,incidence of adverse reactions and willingness to repeat examination of the three groups were compared.Results No statistically significant differences were observed in the BBPS scores among the three groups(P>0.05);The foaming removal effect score in experimental group B was significantly lower than that in routine group and experimental group A,the difference was statistically significant(P<0.05);The total lesion detection rate and polyps detection rate of experimental group B were significantly higher than those of routine group and experimental group A,the differences were statistically significant(P<0.05).The first defecation interval of the routine group was significantly longer than that of experimental group A and experimental group B,the difference was statistically significant(P<0.05);The frequency of defecation was compared among the three groups,and the difference was no statistically significant(P>0.05).The success rate of cecal intubation in the three groups was 100.0%,and the insertion time of colonoscopy was similar,the differences were not statistically significant(P>0.05);The withdrawal time of colonoscopy in experimental group B was significantly shorter than that in routine group and experimental group A,the difference was statistically significant(P<0.05).The incidence of abdominal distension and total adverse reactions in the routine group were higher than those in experimental group A and experimental group B,the differences were statistically significant(P<0.05);The willingness to repeat examination rate of the routine group was significantly lower than that of experimental group A and experimental group B,the differences were statistically significant(P<0.05).Conclusion 290 μg Linaclotide combined with 30 mL Simethicone and 2 L PEG solution regimen has advantages in intestinal preparation for patients with constipation,and can achieve better intestinal cleaning effect than 3 L PEG solution and 290 μg linalopeptide+2 L PEG solution regimen,with higher safety and willingness to repeat examination.It can be recommended for bowel preparation for patients with constipation.
4.Effect of Linaclotide combined with Simethicone and compound polyethylene glycol electrolyte on cleansing effect of bowel in patients with constipation
Jinwen LIAO ; Wenli SHEN ; Lan WU ; Wenxiu LONG ; Wei ZHAO ; Ming WANG ; Zhiqiang DU
China Journal of Endoscopy 2025;31(6):44-53
Objective To investigate the efficacy and safety of Linaclotide combined with Simethicone oil and compound polyethylene glycol electrolyte(PEG)for cleansing effect of bowel in patients with constipation.Methods A prospective randomized controlled trial was designed and implemented by single blind method.383 patients with constipation who underwent colonoscopy from April 2023 to August 2024 were enrolled and randomly divided into routine group(128 cases),experimental group A(128 cases)and experimental group B(127 cases).Routine group treated with 3 L PEG,experimental group A treated with 290 μg Linaclotide+2 L PEG and experimental group B treated with 290 μg Linaclotide+30 mL Simethicone+2 L PEG.Bowel preparation effect[Boston bowel preparation scale(BBPS)scores and foaming removal effect],lesion detection rate,first defecation interval,frequency of defecation,the success rate of cecal intubation,the insertion time of colonoscopy,the withdrawal time of colonoscopy,incidence of adverse reactions and willingness to repeat examination of the three groups were compared.Results No statistically significant differences were observed in the BBPS scores among the three groups(P>0.05);The foaming removal effect score in experimental group B was significantly lower than that in routine group and experimental group A,the difference was statistically significant(P<0.05);The total lesion detection rate and polyps detection rate of experimental group B were significantly higher than those of routine group and experimental group A,the differences were statistically significant(P<0.05).The first defecation interval of the routine group was significantly longer than that of experimental group A and experimental group B,the difference was statistically significant(P<0.05);The frequency of defecation was compared among the three groups,and the difference was no statistically significant(P>0.05).The success rate of cecal intubation in the three groups was 100.0%,and the insertion time of colonoscopy was similar,the differences were not statistically significant(P>0.05);The withdrawal time of colonoscopy in experimental group B was significantly shorter than that in routine group and experimental group A,the difference was statistically significant(P<0.05).The incidence of abdominal distension and total adverse reactions in the routine group were higher than those in experimental group A and experimental group B,the differences were statistically significant(P<0.05);The willingness to repeat examination rate of the routine group was significantly lower than that of experimental group A and experimental group B,the differences were statistically significant(P<0.05).Conclusion 290 μg Linaclotide combined with 30 mL Simethicone and 2 L PEG solution regimen has advantages in intestinal preparation for patients with constipation,and can achieve better intestinal cleaning effect than 3 L PEG solution and 290 μg linalopeptide+2 L PEG solution regimen,with higher safety and willingness to repeat examination.It can be recommended for bowel preparation for patients with constipation.
5.Comparing Outcomes of Banana-Shaped and Straight Cages in Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Diseases: A Systematic Review and Meta-Analysis
Guang-Xun LIN ; Li-Ru HE ; Jin-Niang NAN ; Wen-Bin XU ; Keyi XIAO ; Zhiqiang QUE ; Shang-Wun JHANG ; Chien-Min CHEN ; Ming-Tao ZHU ; Gang RUI
Neurospine 2024;21(1):261-272
Objective:
This meta-analysis aims to refine the understanding of the optimal choice between different cage shapes in transforaminal lumbar interbody fusion (TLIF) by systematically comparing perioperative data, radiological outcomes, clinical results, and complications associated with banana-shaped and straight bullet cages.
Methods:
A meticulous literature search encompassing PubMed, Embase, Scopus, Web of Science, China Knowledge Network, and Wanfang Data was executed up to October 5, 2023. Inclusion criteria focused on studies comparing banana-shaped and straight bullet cages in TLIF. The quality of included studies was assessed using appropriate tools such as the Newcastle-Ottawa Scale (NOS) for nonrandomized studies. Rigorous evaluations were performed for radiographic outcomes, including disc height (DH), segmental lordosis (SL), lumbar lordosis (LL), subsidence, and fusion rates. Clinical outcomes were meticulously evaluated using visual analogue scale (VAS), Oswestry Disability Index (ODI), and complications.
Results:
The analysis incorporated 7 studies, involving 573 patients (297 with banana-shaped cages, 276 with straight cages), all with NOS ratings exceeding 5 stars. No statistically significant differences were observed in operative time, blood loss, or hospitalization between the 2 cage shapes. Banana-shaped cages exhibited greater changes in DH (p = 0.001), SL (p = 0.02), and LL (p = 0.01). Despite statistically higher changes in ODI for straight cages (26.33, p < 0.0001), the actual value remained similar to banana-shaped cages (26.15). Both cage types demonstrated similar efficacy in VAS, complication rates, subsidence, and fusion rates.
Conclusion
Although banana-shaped cages can excel in restoring DH, SL, and LL, straight bullet cages can provide comparable functional improvements, pain relief, and complication rates.
6.Design and application of clinical probation log based on subjective-objective-assessment-plan
Zhifeng WU ; Li MING ; Zhangya YANG ; Min WANG ; Yizhen SUN ; Wang YANG ; Zhiqiang CHEN ; Zhangxue HU ; Yuping ZHANG
Chinese Journal of Medical Education Research 2024;23(7):906-909
Objective:To investigate the application value of a new clinical probation log designed based on the subjective-objective-assessment-plan (SOAP) structured medical record.Methods:Quantitative and qualitative studies were conducted among 97 students in the autumn semester to evaluate the effect of the new clinical probation log based on the SOAP structured medical record on their academic performance and clinical thinking. SPSS 26.0 was used to perform the t-test and ANOVA. Results:The students using the new version had a significantly better score (96.29±1.38) than those using the old version (93.53±1.60) ( P<0.001), while the multivariate analysis showed that the students who first used the old version and then switched to the new version had a significantly better improvement in the score compared with those who first used the new version and then switched to the old version ( P<0.001). The qualitative interview showed that it was necessary to use handwritten internship log, and compared with the old version, the new version could better promote the ordered clinical thinking of students. The teacher comments could give feedbacks, and all the students interviewed thought that the new version held promise for clinical application. Conclusions:The clinical probation log based on the SOAP structured medical record can help to improve the effectiveness of probation and cultivate clinical thinking ability, and thus it holds promise for application in clinical probation teaching.
7.Prognostic nomogram for predicting lower limb venous thrombosis in patients after craniocerebral surgery
Zhiqiang GE ; Gang ZUO ; Qian XU ; Jiyao LIANG ; Yibin CHEN ; Junjie HUO ; Ming JIANG
Journal of Clinical Surgery 2024;32(7):701-705
Objective To explore the risk factors for lower limb venous thrombosis in patients after craniocerebral surgery,and establish a prognostic nomogram for the occurrence of lower limb venous thrombosis.Methods A total of 427 patients who underwent craniotomy for craniocerebral trauma and met the inclusion criteria in the First People's Hospital of Taicang from January 2018 to December 2020 were collected as training group,and the nomogram was drawn and verified internally.And 106 patients who underwent surgery from January 2021 to June 2021 were used as test group,and the model was externally verified set.The nomogram was established and internally validated with the data of the training group,and externally validated with the data of the test group.For the training group,multivariate Logistic regression analysis was performed by including all variables with P<0.05 in univariate analysis,and established the prognostic nomogram by R software.In the training group and the test group,the performance of the nomogram was verified by C-index,calibration chart and decision curve analysis respectively.Results In the training group of 427 people,107 had lower limb venous thrombosis,with an incidence rate of 25.1%.Among the 106 people in the test group,33 developed lower limb venous thrombosis,with an incidence rate of 31.1%.Multivariate logistic regression analysis showed that age,lower preoperative GCS score,postoperative lower limb muscle strength<3,hypertension,and diabetes were independent risk factors for the occurrence of lower limb vein thrombosis after craniocerebral surgery.The C-index of this nomogram in the training group and the test group was 0.837(95%CI:0.796-0.878)and 0.933(95%CI:0.886-0.979),respectively.Conclusion The nomogram including the age,preoperative GCS score,postoperative lower limb muscle strength<3,hypertension,and diabetes can predict the probability of lower limb vein thrombosis after craniocerebral surgery with convenient discrimination and clinical utility.
8.Characterization of rhinovirus in patients with respiratory tract infection in Mianyang, 2021—2022
Yue GONG ; Ming PAN ; Guo CHEN ; Qinqin SONG ; Yanhai WANG ; Chen GAO ; Zhiqiang XIA ; Lulu WANG ; Qian CHENG ; Kexin ZONG ; Jun HAN
Chinese Journal of Experimental and Clinical Virology 2024;38(3):279-285
Objective:To understand the prevalence and characteristics of Rhinovirus (HRV) infection in influenza-like Illness (ILIs) patients in Mianyang, Sichuan province, China.Methods:Throat swabs were collected from patients of ILIs in sentinel hospitals in Mianyang during 2021—2022. Real-time fluorescence quantitative PCR was used to detect 16 common pathogens. The VP4/VP2 coding region genes of HRV positive samples were amplified by nest PCR. The phylogeny, consistency and amino acid variation of different serotypes were analyzed and compared with reference sequences from GenBank database.Results:A total of 332 ILIs′ samples were collected with a virus detection rate of 58.73% (195/332) in Mianyang. Among them, 23 samples (23/332) were HRV-positive, and 18 VP4/VP2 sequences of HRV strains were successfully amplified. It was found that 13 HRV serotypes were detected in ILIs samples in Mianyang, which belonged to three genotypes, namely HRV-A (12 strains), HRV-B (5 strains) and HRV-C (1 strain).Conclusions:HRV was one of the pathogens of ILIs cases in Mianyang during 2021—2022, with HRV-A types as the dominant strains.
9.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
10.Comparing Outcomes of Banana-Shaped and Straight Cages in Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Diseases: A Systematic Review and Meta-Analysis
Guang-Xun LIN ; Li-Ru HE ; Jin-Niang NAN ; Wen-Bin XU ; Keyi XIAO ; Zhiqiang QUE ; Shang-Wun JHANG ; Chien-Min CHEN ; Ming-Tao ZHU ; Gang RUI
Neurospine 2024;21(1):261-272
Objective:
This meta-analysis aims to refine the understanding of the optimal choice between different cage shapes in transforaminal lumbar interbody fusion (TLIF) by systematically comparing perioperative data, radiological outcomes, clinical results, and complications associated with banana-shaped and straight bullet cages.
Methods:
A meticulous literature search encompassing PubMed, Embase, Scopus, Web of Science, China Knowledge Network, and Wanfang Data was executed up to October 5, 2023. Inclusion criteria focused on studies comparing banana-shaped and straight bullet cages in TLIF. The quality of included studies was assessed using appropriate tools such as the Newcastle-Ottawa Scale (NOS) for nonrandomized studies. Rigorous evaluations were performed for radiographic outcomes, including disc height (DH), segmental lordosis (SL), lumbar lordosis (LL), subsidence, and fusion rates. Clinical outcomes were meticulously evaluated using visual analogue scale (VAS), Oswestry Disability Index (ODI), and complications.
Results:
The analysis incorporated 7 studies, involving 573 patients (297 with banana-shaped cages, 276 with straight cages), all with NOS ratings exceeding 5 stars. No statistically significant differences were observed in operative time, blood loss, or hospitalization between the 2 cage shapes. Banana-shaped cages exhibited greater changes in DH (p = 0.001), SL (p = 0.02), and LL (p = 0.01). Despite statistically higher changes in ODI for straight cages (26.33, p < 0.0001), the actual value remained similar to banana-shaped cages (26.15). Both cage types demonstrated similar efficacy in VAS, complication rates, subsidence, and fusion rates.
Conclusion
Although banana-shaped cages can excel in restoring DH, SL, and LL, straight bullet cages can provide comparable functional improvements, pain relief, and complication rates.

Result Analysis
Print
Save
E-mail