1.Chinese expert consensus on the diagnosis and treatment of chronic pain after lung surgery with integrated Traditional Chinese and Western medicine (2026 edition)
Jichen QU ; Wentian ZHANG ; Jianqiao CAI ; Zhigang CHEN ; Bin LI ; Wei DAI ; Xiangwu WANG ; Yan LI ; Xiang LÜ ; ; Yongfu ZHU ; Mingran XIE ; Sufang ZHANG ; Lei JIANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(04):522-534
Chronic post-surgical pain (CPSP) is a common long-term complication following lung surgery. Its high incidence significantly impacts patients’ quality of life and functional recovery, and imposes a substantial socioeconomic burden. This consensus aims to systematically establish a standardized integrated Chinese and Western medicine diagnostic and treatment framework for chronic post-lung surgery pain (CPLSP). Based on the latest domestic and international evidence-based medical research and multidisciplinary clinical experience, the working group comprehensively elaborates on core issues regarding CPLSP, including its definition, epidemiology, pathogenesis, clinical assessment, Western medical treatment, traditional Chinese medicine (TCM) treatment, and integrated strategies. The consensus emphasizes a patient-centered approach, adhering to the principles of multimodality, individualization, and stepwise management, highlighting the synergistic advantages of integrating Chinese and Western medicine throughout the entire perioperative management cycle encompassing "perioperative anti-inflammation, acute analgesia, and chronic rehabilitation." Through systematic literature retrieval and evidence integration, a total of 9 core recommendations were established to provide scientifically sound and clinically practical guidance.
2.Associations between statins and all-cause mortality and cardiovascular events among peritoneal dialysis patients: A multi-center large-scale cohort study.
Shuang GAO ; Lei NAN ; Xinqiu LI ; Shaomei LI ; Huaying PEI ; Jinghong ZHAO ; Ying ZHANG ; Zibo XIONG ; Yumei LIAO ; Ying LI ; Qiongzhen LIN ; Wenbo HU ; Yulin LI ; Liping DUAN ; Zhaoxia ZHENG ; Gang FU ; Shanshan GUO ; Beiru ZHANG ; Rui YU ; Fuyun SUN ; Xiaoying MA ; Li HAO ; Guiling LIU ; Zhanzheng ZHAO ; Jing XIAO ; Yulan SHEN ; Yong ZHANG ; Xuanyi DU ; Tianrong JI ; Yingli YUE ; Shanshan CHEN ; Zhigang MA ; Yingping LI ; Li ZUO ; Huiping ZHAO ; Xianchao ZHANG ; Xuejian WANG ; Yirong LIU ; Xinying GAO ; Xiaoli CHEN ; Hongyi LI ; Shutong DU ; Cui ZHAO ; Zhonggao XU ; Li ZHANG ; Hongyu CHEN ; Li LI ; Lihua WANG ; Yan YAN ; Yingchun MA ; Yuanyuan WEI ; Jingwei ZHOU ; Yan LI ; Caili WANG ; Jie DONG
Chinese Medical Journal 2025;138(21):2856-2858
3.Personalized mandibular reconstruction assisted by three-dimensional retrieval model based on fully connected neural network and a database of mandibles.
Shiyu QIU ; Yang LIAN ; Yifan KANG ; Lei ZHANG ; Yiwang CAI ; Xiaofeng SHAN ; Zhigang CAI
Journal of Peking University(Health Sciences) 2025;57(2):360-368
OBJECTIVE:
To propose a new protocol for personalized mandibular reconstruction assisted by three-dimensional (3D) retrieval model based on fully connected neural network (FCNN) and a database of mandibles, and to verify clinical feasibility of the protocol.
METHODS:
A database of mandibles of 300 normal northern Chinese Han people was established. On the basis of cephalometry, the mandible landmarks with good stability were further screened. Mandibular landmarks were selected and geometric features of the mandible were extracted. A 3D retrieval algorithm was developed, which could retrieve the mandible most similar to a given mandible from the database. A FCNN was built to train the algorithm to improve accuracy of the 3D retrieval model. Using Geomagic Control 2014 software, matching accuracy of the 3D retrieval model was based on aforementioned mandible database and algorithm. From December 2019 to March 2021, a total of 5 patients underwent personalized mandibular reconstruction assisted by a 3D retrieval model based on mandible database and FCNN in the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The most similar mandible was retrieved from mandible database through 3D retrieval algorithm. It was used to restore the premorbid morphology of defect area and guide mandibular reconstruction. For the 5 patients, mandible was reconstructed with iliac flap. Virtual surgical plan was transformed using individual surgical guides.
RESULTS:
Through screening, mandibular landmarks with high reproducibility and stability were identified and composed of mandibular landmarker protocols. After training, the average deviation between most similar mandible retrieved from the 300-case mandible database through 3D retrieval model based on FCNN and given mandible was (1.77±0.44) mm. And the root-mean-square deviation between the most similar mandible retrieved from the database and given mandible was (2.58±0.86) mm. The mandibular reconstruction surgery was successful in all the 5 patients. Their facial symmetry and occlusion were restored. All the patients were satisfied with postoperative appearance. The mean deviation between postoperative mandible and preoperative design was (0.98±0.17) mm. The area with a deviation ≤1 mm accounted for 61.34%±14. 13%, ≤2 mm accounted for 83.82%±7.35%, and ≤3 mm accounted for 93.94%± 2.87%.
CONCLUSION
The personalized mandibular reconstruction assisted by 3D retrieval model based on the 300-case mandible database and FCNN is feasible clinically.
Humans
;
Neural Networks, Computer
;
Mandibular Reconstruction/methods*
;
Mandible/diagnostic imaging*
;
Imaging, Three-Dimensional/methods*
;
Adult
;
Databases, Factual
;
Female
;
Male
;
Algorithms
;
Middle Aged
;
Cephalometry
4.Study on key performance of medical ultrasonic probe of third-party repair based on test data
Lei XU ; Jun YAO ; Taotao FAN ; Yinkai CHEN ; Zhigang WANG ; Jiyun LING
China Medical Equipment 2025;22(8):174-176,181
Objective:To conduct performance tests on medical ultrasound probes repaired by the third party,and explore whether the key parameters of the probes of third-party repair can meet the requirements of clinical use for quality.Methods:A total of 79 ultrasound probes that had been repaired by the third party were selected from different medical institutions.The performance tests were conducted on multiple parameters of ultrasound probes of different models and brands in accordance with national technical standards and relevant industry norms.Then,the test results were analyzed,studied and evaluated.Results:The tested results of the temperature rise and the leakage current of the ultrasound probes,which were repaired by the third party,met the national standards.However,in the test for sound power,26.58%of the probes failed to meet the national standards,which outputted sound intensity that was calculated was higher than the specified value.Conclusion:The general performance of the probes that have been repaired by the third party is well,but the quality of the repair is uneven levels,and some indicators do not meet national standards or industry norms,which might lead to occur risks in ultrasound diagnosis of medical institutions.It is recommended to implement regular test for quality and performance of medical ultrasound equipment,and establish a method and system for quality monitoring and re-evaluation after sale of repair for medical ultrasound,so as to ensure the use and safety of the equipment.
5.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
6.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.
7.Pharmacovigilance Profiling Technology for Patient Medical Records Based on Large Language Models
Zhengshan WU ; Shu ZHANG ; Yimin LIN ; Yi LEI ; Qing WANG ; Zhigang SUN ; Lin ZHANG
Herald of Medicine 2025;44(4):554-560
Objective To enhance the efficiency and accuracy of post-marketing safety monitoring and evaluation of drugs in China by studying large language models-based patient medical record pharmacovigilance profiling techniques,providing scientific methods and technical support to ensure the safe use of drugs for patients.Methods This study constructs a pharmacovigilance profile that includes individual patient differences,medication details,and adverse reaction manifestations.It enhances a large language model with a knowledge graph in the field of pharmacovigilance and designs targeted prompts to guide the model to output pharmacovigilance profiles.Results Large language models demonstrate significant advantages in active monitoring,effectively processing and analyzing medical text data,and improving the monitoring and prediction capabilities of drug adverse reactions.Through the design of prompts,the model can more accurately depict patient pharmacovigilance profiles,providing decision support for medical professionals.Conclusions The study of large language model-based patient medical record pharmacovigilance profiling technology provides scientific evidence and technical support for the early detection and prevention of drug adverse reactions,helping to reduce medical costs,improve medical outcome prognoses,and opens new paths to ensure patient drug safety.
8.Pharmacovigilance Profiling Technology for Patient Medical Records Based on Large Language Models
Zhengshan WU ; Shu ZHANG ; Yimin LIN ; Yi LEI ; Qing WANG ; Zhigang SUN ; Lin ZHANG
Herald of Medicine 2025;44(4):554-560
Objective To enhance the efficiency and accuracy of post-marketing safety monitoring and evaluation of drugs in China by studying large language models-based patient medical record pharmacovigilance profiling techniques,providing scientific methods and technical support to ensure the safe use of drugs for patients.Methods This study constructs a pharmacovigilance profile that includes individual patient differences,medication details,and adverse reaction manifestations.It enhances a large language model with a knowledge graph in the field of pharmacovigilance and designs targeted prompts to guide the model to output pharmacovigilance profiles.Results Large language models demonstrate significant advantages in active monitoring,effectively processing and analyzing medical text data,and improving the monitoring and prediction capabilities of drug adverse reactions.Through the design of prompts,the model can more accurately depict patient pharmacovigilance profiles,providing decision support for medical professionals.Conclusions The study of large language model-based patient medical record pharmacovigilance profiling technology provides scientific evidence and technical support for the early detection and prevention of drug adverse reactions,helping to reduce medical costs,improve medical outcome prognoses,and opens new paths to ensure patient drug safety.
9.Study on key performance of medical ultrasonic probe of third-party repair based on test data
Lei XU ; Jun YAO ; Taotao FAN ; Yinkai CHEN ; Zhigang WANG ; Jiyun LING
China Medical Equipment 2025;22(8):174-176,181
Objective:To conduct performance tests on medical ultrasound probes repaired by the third party,and explore whether the key parameters of the probes of third-party repair can meet the requirements of clinical use for quality.Methods:A total of 79 ultrasound probes that had been repaired by the third party were selected from different medical institutions.The performance tests were conducted on multiple parameters of ultrasound probes of different models and brands in accordance with national technical standards and relevant industry norms.Then,the test results were analyzed,studied and evaluated.Results:The tested results of the temperature rise and the leakage current of the ultrasound probes,which were repaired by the third party,met the national standards.However,in the test for sound power,26.58%of the probes failed to meet the national standards,which outputted sound intensity that was calculated was higher than the specified value.Conclusion:The general performance of the probes that have been repaired by the third party is well,but the quality of the repair is uneven levels,and some indicators do not meet national standards or industry norms,which might lead to occur risks in ultrasound diagnosis of medical institutions.It is recommended to implement regular test for quality and performance of medical ultrasound equipment,and establish a method and system for quality monitoring and re-evaluation after sale of repair for medical ultrasound,so as to ensure the use and safety of the equipment.
10.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.

Result Analysis
Print
Save
E-mail