1.Univariate and multivariate regression analysis of femoral neck shortening after cannulated screw fixation in femoral neck fractures
Xinbao XU ; Feiyang CHEN ; Yinbing CHEN ; Feixiang ZHANG ; Shujun LYU ; Haidong CUI ; Zhigang CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):620-625
BACKGROUND:With the development of the aging trend of society,the incidence of femoral neck fractures is increasing.Currently,the preferred surgical treatment is cannulated screw internal fixation.However,post-surgical femoral neck shortening occurs in some cases,resulting in impaired hip functionality.OBJECTIVE:To investigate the incidence of femoral neck shortening following the use of half-threaded cannulated screws for internal fixation in patients with femoral neck fractures,to analyze the effect on hip function,and to identify factors contributing to neck shortening.METHODS:A retrospective analysis was conducted on the medical records of 102 patients treated with half-threaded cannulated screws in an inverted triangle setup for femoral neck fractures at Affiliated Hai'an Hospital of Nantong University from January 2016 to January 2021.This group included 36 males and 66 females at the mean age of(57.2±7.7)years,with 34 cases of Garden type Ⅰ and Ⅱ fractures and 68 of Garden type Ⅲ and Ⅳ fractures.The mean bone mineral density value T was-2.8 SD.The Harris score was used to evaluate the hip function.During the follow-up period,the occurrence of femoral neck shortening was determined using X-ray imagery,and the factors influencing this shortening were examined using both univariate and multivariate regression analyses.RESULTS AND CONCLUSION:(1)Among the 102 patients with femoral neck fractures,30 patients developed femoral neck shortening,accounting for 29.4%.72 patients had no femoral neck shortening(70.6%).(2)The Harris score for patients experiencing neck shortening was significantly lower than that for patients without shortening(P<0.05).(3)The study identified several factors associated with femoral neck shortening following the internal fixation of femoral neck fractures included age,gender,bone mineral density value T,preoperative Garden classification,and quality of reduction.These factors not only affect the shortening of the femoral neck after surgery,but are also directly related to the functional performance of the patient's hip joint.(4)Femoral neck shortening after surgery for femoral neck fracture is associated with various clinical parameters,especially the patient's age,gender,bone mineral density,preoperative classification,and accuracy of reduction during surgery.
2.Univariate and multivariate regression analysis of femoral neck shortening after cannulated screw fixation in femoral neck fractures
Xinbao XU ; Feiyang CHEN ; Yinbing CHEN ; Feixiang ZHANG ; Shujun LYU ; Haidong CUI ; Zhigang CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):620-625
BACKGROUND:With the development of the aging trend of society,the incidence of femoral neck fractures is increasing.Currently,the preferred surgical treatment is cannulated screw internal fixation.However,post-surgical femoral neck shortening occurs in some cases,resulting in impaired hip functionality.OBJECTIVE:To investigate the incidence of femoral neck shortening following the use of half-threaded cannulated screws for internal fixation in patients with femoral neck fractures,to analyze the effect on hip function,and to identify factors contributing to neck shortening.METHODS:A retrospective analysis was conducted on the medical records of 102 patients treated with half-threaded cannulated screws in an inverted triangle setup for femoral neck fractures at Affiliated Hai'an Hospital of Nantong University from January 2016 to January 2021.This group included 36 males and 66 females at the mean age of(57.2±7.7)years,with 34 cases of Garden type Ⅰ and Ⅱ fractures and 68 of Garden type Ⅲ and Ⅳ fractures.The mean bone mineral density value T was-2.8 SD.The Harris score was used to evaluate the hip function.During the follow-up period,the occurrence of femoral neck shortening was determined using X-ray imagery,and the factors influencing this shortening were examined using both univariate and multivariate regression analyses.RESULTS AND CONCLUSION:(1)Among the 102 patients with femoral neck fractures,30 patients developed femoral neck shortening,accounting for 29.4%.72 patients had no femoral neck shortening(70.6%).(2)The Harris score for patients experiencing neck shortening was significantly lower than that for patients without shortening(P<0.05).(3)The study identified several factors associated with femoral neck shortening following the internal fixation of femoral neck fractures included age,gender,bone mineral density value T,preoperative Garden classification,and quality of reduction.These factors not only affect the shortening of the femoral neck after surgery,but are also directly related to the functional performance of the patient's hip joint.(4)Femoral neck shortening after surgery for femoral neck fracture is associated with various clinical parameters,especially the patient's age,gender,bone mineral density,preoperative classification,and accuracy of reduction during surgery.
3.Study on the correlation between oxygenation index and monitored parameters of ventilator lung injury view
Yuanjuan TAO ; Yang LI ; Zhipeng LIU ; Zhifeng JI ; Zhigang CUI ; Chunhua YANG ; Dan QI
China Medical Equipment 2025;22(8):7-10
Objective:To explore the correlation between the oxygenation index and the monitored parameters of lung injury view in ventilator,so as to provide a basis for monitoring the change of oxygenation index by the parameters of lung injury view.Methods:A total of 28 patients who received mechanical ventilation treatment and admitted to respiratory department of the First Affiliated Hospital with Nanjing Medical University from May 14 to September 30,2024 were selected.The monitored parameters of lung injury views of them during mechanical ventilation treatment with invasive ventilators were collected,including platform pressure(Pplat),driving pressure(ΔP),mechanical energy(Emech),ratio of tidal volume to ideal body weight(TVe/IBW),etc..Then,the data of oxygenation index were obtained.Finally,135 valid data were screened out.The 84 pieces of data with oxygenation index≤300mmHg were included in low oxygen group,and 51 data with oxygenation index>300mmHg were included in normal group.The correlations between oxygenation index and Pplat,ΔP,Emech,TVe/IBW were conducted by pairwise analysis.Results:In the low oxygen group,the oxygenation index was[(196.302±74.522)mmHg]significantly negative correlation with Emech[(12.686±5.401)J/min](ρ=-0.425,P<0.05),but not was significant correlation with Pplat,ΔP,and TVe/IBW(P>0.05).In the normal group,there were not significant correlations between the oxygenation index and Pplat,ΔP,Emech and TVe/IBW(P>0.05).There was a significant negative correlation between Emech and rank of oxygenation index(β=-0.389,P<0.05)in the low oxygen group.Conclusion:The visualization function of the Emech of the monitored parameters in lung injury view of ventilator can provide help for monitoring the changes of oxygenation index of patients in the low oxygen group,and can improve the oxygenation of patients by optimizing mechanical energy.However,it is necessary to balance the contradiction between ventilation intensity and protection for lung.
4.Associations between statins and all-cause mortality and cardiovascular events among peritoneal dialysis patients: A multi-center large-scale cohort study.
Shuang GAO ; Lei NAN ; Xinqiu LI ; Shaomei LI ; Huaying PEI ; Jinghong ZHAO ; Ying ZHANG ; Zibo XIONG ; Yumei LIAO ; Ying LI ; Qiongzhen LIN ; Wenbo HU ; Yulin LI ; Liping DUAN ; Zhaoxia ZHENG ; Gang FU ; Shanshan GUO ; Beiru ZHANG ; Rui YU ; Fuyun SUN ; Xiaoying MA ; Li HAO ; Guiling LIU ; Zhanzheng ZHAO ; Jing XIAO ; Yulan SHEN ; Yong ZHANG ; Xuanyi DU ; Tianrong JI ; Yingli YUE ; Shanshan CHEN ; Zhigang MA ; Yingping LI ; Li ZUO ; Huiping ZHAO ; Xianchao ZHANG ; Xuejian WANG ; Yirong LIU ; Xinying GAO ; Xiaoli CHEN ; Hongyi LI ; Shutong DU ; Cui ZHAO ; Zhonggao XU ; Li ZHANG ; Hongyu CHEN ; Li LI ; Lihua WANG ; Yan YAN ; Yingchun MA ; Yuanyuan WEI ; Jingwei ZHOU ; Yan LI ; Caili WANG ; Jie DONG
Chinese Medical Journal 2025;138(21):2856-2858
5.Study on transmission characteristics and genetic variation of carbapenem-resistant Klebsiella pneumonia based on whole genome sequencing
Jiachen LI ; Yanying CHEN ; Yanlei GE ; Jinrui HU ; Xiaoli DU ; Jinyue LIU ; Huan XING ; Pengfang GAO ; Xiao HAN ; Yuelong LI ; Yating TANG ; Juan LI ; Zhigang CUI ; Jinhui ZHANG ; Haijian ZHOU ; Aiying DONG
Chinese Journal of Preventive Medicine 2025;59(6):892-900
Objective:To analyze the short-term hospital-based transmission characteristics and gene variation of Carbapenem-Resistant Klebsiella pneumoniae (CRKP) by genome-wide technique to provide evidence for transmission control. Methods:The experimental strain was derived from all the CRKP isolated in Affiliated Hospital of North China University of Science and Technology from October 2022 to December 2023. Strain identification and drug susceptibility were tested with VITEK 2-Compact automatic bacterial identification drug susceptibility analyzer or disk method, and the results were interpreted through whole genome sequencing. The ST type, carbapenem resistance gene, virulence factor, and O serotype of the collected strains were analyzed.Results:Among the 115 strains of CRKP, 94 strains were isolated from the intensive care unit (ICU), accounting for 81.7%, and 21 strains were isolated from the non-intensive care unit (NICU), accounting for 18.3%. The 115 strains of CRKP can be divided into 11 ST types, of which ST11 type was the most (54.8%, 63/115), followed by ST15 type (22.6%, 26/115) and ST5492 type (15.7%, 18/115). Type ST5492 was a new clonal group in the region. The 115 strains of CRKP could be divided into 7 O serotypes, most of which were O2a type(32.2%,37/115), followed by O5 type(30.4%,35/115) and O1 type(27.8%,32/115). The resistance genes of carbapenem antibiotics showed that there were 107 strains carrying the blaKPC-2 gene, one strain with the blaNDM-1 gene, and one strain with both the blaKPC-2 and blaNDM-13 genes. Virulence genes were detected in 55 CRKP strains (47.8%, 55/115), among which six strains detected peg-344, iucA, iroB, rmpA, and rmpA2 virulence genes (5.2%, 6/115). Four virulence genes ( peg-344, iucA, rmpA, and rmpA2) were detected in 34 strains (29.6%, 34/115). Three virulence genes ( iucA, iroB and rmpA) were detected in two strains (1.7%, 2/115). Three virulence genes ( peg-344, iucA and rmpA) were detected in one strain (0.8%, 1/115). IucA and rmpA virulence genes were detected in 12 strains (10.4%, 12/115). KPC-2_ST11_O2a, KPC-2_ST15_O1 and KPC-2_ST5492_O5 were dominant clones, and their distribution was mainly in the intensive care unit. The whole genome sequence analysis showed that there were three dominant clones, among which ST11 clones were subdivided into three dominant O serotypes, all of which were mainly in the intensive care unit. Conclusion:The popular strain in the hospital of CRKP is a KPC-2_ST11 clone group carrying iucA, rmpA/rmpA2, with cross-department transmission and mutation. ST5492 is a newly-launched clone type. The intensive care unit of hvKP carrying five virulence genes, including peg-344, should be alert to the epidemic risk of CR-hvKP outbreak.
6.Study on transmission characteristics and genetic variation of carbapenem-resistant Klebsiella pneumonia based on whole genome sequencing
Jiachen LI ; Yanying CHEN ; Yanlei GE ; Jinrui HU ; Xiaoli DU ; Jinyue LIU ; Huan XING ; Pengfang GAO ; Xiao HAN ; Yuelong LI ; Yating TANG ; Juan LI ; Zhigang CUI ; Jinhui ZHANG ; Haijian ZHOU ; Aiying DONG
Chinese Journal of Preventive Medicine 2025;59(6):892-900
Objective:To analyze the short-term hospital-based transmission characteristics and gene variation of Carbapenem-Resistant Klebsiella pneumoniae (CRKP) by genome-wide technique to provide evidence for transmission control. Methods:The experimental strain was derived from all the CRKP isolated in Affiliated Hospital of North China University of Science and Technology from October 2022 to December 2023. Strain identification and drug susceptibility were tested with VITEK 2-Compact automatic bacterial identification drug susceptibility analyzer or disk method, and the results were interpreted through whole genome sequencing. The ST type, carbapenem resistance gene, virulence factor, and O serotype of the collected strains were analyzed.Results:Among the 115 strains of CRKP, 94 strains were isolated from the intensive care unit (ICU), accounting for 81.7%, and 21 strains were isolated from the non-intensive care unit (NICU), accounting for 18.3%. The 115 strains of CRKP can be divided into 11 ST types, of which ST11 type was the most (54.8%, 63/115), followed by ST15 type (22.6%, 26/115) and ST5492 type (15.7%, 18/115). Type ST5492 was a new clonal group in the region. The 115 strains of CRKP could be divided into 7 O serotypes, most of which were O2a type(32.2%,37/115), followed by O5 type(30.4%,35/115) and O1 type(27.8%,32/115). The resistance genes of carbapenem antibiotics showed that there were 107 strains carrying the blaKPC-2 gene, one strain with the blaNDM-1 gene, and one strain with both the blaKPC-2 and blaNDM-13 genes. Virulence genes were detected in 55 CRKP strains (47.8%, 55/115), among which six strains detected peg-344, iucA, iroB, rmpA, and rmpA2 virulence genes (5.2%, 6/115). Four virulence genes ( peg-344, iucA, rmpA, and rmpA2) were detected in 34 strains (29.6%, 34/115). Three virulence genes ( iucA, iroB and rmpA) were detected in two strains (1.7%, 2/115). Three virulence genes ( peg-344, iucA and rmpA) were detected in one strain (0.8%, 1/115). IucA and rmpA virulence genes were detected in 12 strains (10.4%, 12/115). KPC-2_ST11_O2a, KPC-2_ST15_O1 and KPC-2_ST5492_O5 were dominant clones, and their distribution was mainly in the intensive care unit. The whole genome sequence analysis showed that there were three dominant clones, among which ST11 clones were subdivided into three dominant O serotypes, all of which were mainly in the intensive care unit. Conclusion:The popular strain in the hospital of CRKP is a KPC-2_ST11 clone group carrying iucA, rmpA/rmpA2, with cross-department transmission and mutation. ST5492 is a newly-launched clone type. The intensive care unit of hvKP carrying five virulence genes, including peg-344, should be alert to the epidemic risk of CR-hvKP outbreak.
7.Exploration on statistics and method of the results of resolution parameters of quality control method of diagnostic equipment with ultrasound based on real world data
Zhipeng LIU ; Mingming LI ; Zhigang CUI ; Chunhua YANG ; Yang LI
China Medical Equipment 2025;22(6):35-38
Objective:To explore more objective detection method for the performance of diagnostic equipment with ultrasound,so as to demonstrate that the subjectivity of the interpretation criteria will affect the results of resolution parameters of detection performance of ultrasonic equipment.Methods:A total of 77 conventional probes of 33 ultrasound equipment of Jiangsu Provincial Hospital were collected and sorted out.The resolution parameters of their performance were tested twice from 2022 to 2023 by the technical personnel of our institute and the tester of Jiangsu Institute of Metrology.The data was described by using the quartiles method.The resolution parameters of performances of ultrasound equipment and probes were paired to conduct Wilcoxon rank sum test,so as to compare the differences in same institute between different years,and in same year between different institute in testing the resolution parameters of performances of ultrasound equipment and probes.Results:For linear array probes,as long as the performance was tested in accordance with the standard method,there was no statistically significant difference in the resolution parameters measured between different institutes and between different times(P>0.05).For the convex array probe,in 2023,the lateral resolution[2(2,2)]of the 70mm target group,and the axial and lateral resolutions[1(1,1)and 3(3,3.25)]of the 120mm target group of our institute were different with the lateral resolution[2(1,2)]of the 70mm target group,and the axial and lateral resolutions[2(2,3)and 2(2,3)]of the 120mm target group of Jiangsu Institute of Metrology,and the differences of them between our institute and Jiangsu Institute of Metrology were significant(Z=-2.887,-2.53,-3.69,P<0.05),respectively.In our institute,the axial and lateral resolutions[1(1,2)and 2.5(2,3)]of the 70mm target group,and the axial resolution[1(1,2)]of the 120mm target group in 2022 were different with the axial and lateral resolutions[1(1,1)and 2(2,2)]of the 70mm target group,and the axial resolution[1(1,1)]of the 120mm target group in 2023,and the differences of them between two years were significant(Z=-3.317,-3.419,-2.982,P<0.05).In Jiangsu Institute of Metrology,the lateral resolutions of the 70mm target group,and the axial resolution[1(1,1)]of the 120mm target group in 2022 year were different with those in 2023 year,and the differences of them were significant(Z=-2.333,-3.051,P<0.05),respectively.Conclusion:The interpretation for lateral resolution of convex array probe in target group with high depth,the difference of subjective interpretation criteria will cause the essential difference of final results.This paper suggested that the key image should be retained when the resolution of the image of target group with high depth of the convex array probe is interpreted.At the later stage,artificial intelligence(AI)-assisted quality control can also be introduced to conduct objective interpretation by computers.
8.Exploration on statistics and method of the results of resolution parameters of quality control method of diagnostic equipment with ultrasound based on real world data
Zhipeng LIU ; Mingming LI ; Zhigang CUI ; Chunhua YANG ; Yang LI
China Medical Equipment 2025;22(6):35-38
Objective:To explore more objective detection method for the performance of diagnostic equipment with ultrasound,so as to demonstrate that the subjectivity of the interpretation criteria will affect the results of resolution parameters of detection performance of ultrasonic equipment.Methods:A total of 77 conventional probes of 33 ultrasound equipment of Jiangsu Provincial Hospital were collected and sorted out.The resolution parameters of their performance were tested twice from 2022 to 2023 by the technical personnel of our institute and the tester of Jiangsu Institute of Metrology.The data was described by using the quartiles method.The resolution parameters of performances of ultrasound equipment and probes were paired to conduct Wilcoxon rank sum test,so as to compare the differences in same institute between different years,and in same year between different institute in testing the resolution parameters of performances of ultrasound equipment and probes.Results:For linear array probes,as long as the performance was tested in accordance with the standard method,there was no statistically significant difference in the resolution parameters measured between different institutes and between different times(P>0.05).For the convex array probe,in 2023,the lateral resolution[2(2,2)]of the 70mm target group,and the axial and lateral resolutions[1(1,1)and 3(3,3.25)]of the 120mm target group of our institute were different with the lateral resolution[2(1,2)]of the 70mm target group,and the axial and lateral resolutions[2(2,3)and 2(2,3)]of the 120mm target group of Jiangsu Institute of Metrology,and the differences of them between our institute and Jiangsu Institute of Metrology were significant(Z=-2.887,-2.53,-3.69,P<0.05),respectively.In our institute,the axial and lateral resolutions[1(1,2)and 2.5(2,3)]of the 70mm target group,and the axial resolution[1(1,2)]of the 120mm target group in 2022 were different with the axial and lateral resolutions[1(1,1)and 2(2,2)]of the 70mm target group,and the axial resolution[1(1,1)]of the 120mm target group in 2023,and the differences of them between two years were significant(Z=-3.317,-3.419,-2.982,P<0.05).In Jiangsu Institute of Metrology,the lateral resolutions of the 70mm target group,and the axial resolution[1(1,1)]of the 120mm target group in 2022 year were different with those in 2023 year,and the differences of them were significant(Z=-2.333,-3.051,P<0.05),respectively.Conclusion:The interpretation for lateral resolution of convex array probe in target group with high depth,the difference of subjective interpretation criteria will cause the essential difference of final results.This paper suggested that the key image should be retained when the resolution of the image of target group with high depth of the convex array probe is interpreted.At the later stage,artificial intelligence(AI)-assisted quality control can also be introduced to conduct objective interpretation by computers.
9.Study on the correlation between oxygenation index and monitored parameters of ventilator lung injury view
Yuanjuan TAO ; Yang LI ; Zhipeng LIU ; Zhifeng JI ; Zhigang CUI ; Chunhua YANG ; Dan QI
China Medical Equipment 2025;22(8):7-10
Objective:To explore the correlation between the oxygenation index and the monitored parameters of lung injury view in ventilator,so as to provide a basis for monitoring the change of oxygenation index by the parameters of lung injury view.Methods:A total of 28 patients who received mechanical ventilation treatment and admitted to respiratory department of the First Affiliated Hospital with Nanjing Medical University from May 14 to September 30,2024 were selected.The monitored parameters of lung injury views of them during mechanical ventilation treatment with invasive ventilators were collected,including platform pressure(Pplat),driving pressure(ΔP),mechanical energy(Emech),ratio of tidal volume to ideal body weight(TVe/IBW),etc..Then,the data of oxygenation index were obtained.Finally,135 valid data were screened out.The 84 pieces of data with oxygenation index≤300mmHg were included in low oxygen group,and 51 data with oxygenation index>300mmHg were included in normal group.The correlations between oxygenation index and Pplat,ΔP,Emech,TVe/IBW were conducted by pairwise analysis.Results:In the low oxygen group,the oxygenation index was[(196.302±74.522)mmHg]significantly negative correlation with Emech[(12.686±5.401)J/min](ρ=-0.425,P<0.05),but not was significant correlation with Pplat,ΔP,and TVe/IBW(P>0.05).In the normal group,there were not significant correlations between the oxygenation index and Pplat,ΔP,Emech and TVe/IBW(P>0.05).There was a significant negative correlation between Emech and rank of oxygenation index(β=-0.389,P<0.05)in the low oxygen group.Conclusion:The visualization function of the Emech of the monitored parameters in lung injury view of ventilator can provide help for monitoring the changes of oxygenation index of patients in the low oxygen group,and can improve the oxygenation of patients by optimizing mechanical energy.However,it is necessary to balance the contradiction between ventilation intensity and protection for lung.
10.Factors related to re-falling of knee range of motion after arthrolysis for post-traumatic knee stiffness
Zhigang CUI ; Taoran JIN ; Sihai LIU ; Fei WANG ; Kemin LIU ; Jianjun LI
Chinese Journal of Rehabilitation Theory and Practice 2024;30(5):565-569
Objective To observe the temporary loss(re-falling)of knee range of motion(ROM)during rehabilitation after arthroly-sis for post-traumatic knee stiffness,and analyze the factors related to it. Methods From July,2016 to September,2019,64 patients(68 knees)in Beijing Bo'ai Hospital accepted minimally inva-sive arthrolysis for post-traumatic knee stiffness,and were followed up for twelve months.ROM of flexion and extension of knee was measured before operation,and one,six and twelve weeks,and six and twelve months af-ter operation;while they were asssessed with Hospital for Special Surgery Knee Score(HSS).Multivariate Logis-tic regression was performed on re-falling. Results The ROM and HSS score improved as a whole after operation;however,HSS score improved constantly,but ROM decreased six weeks after operation compared with that one weeks after operation,involving 46 knees of 44 cases.Arthrolysis longer than 12 months from primary injuries,multiple complicated fracture and history of infection were the risk factors for re-falling(OR>8.058,P<0.05). Conclusion Minimally invasive arthrolysis is effective on knee function after arthrolysis for post-traumatic knee stiff-ness.However,re-falling of ROM may happen during rehabilitation.Delay of operation,multiple complicated fracture and history of infection may increase the risk of re-falling.

Result Analysis
Print
Save
E-mail