1.Telpegfilgrastim for chemotherapy-induced neutropenia in breast cancer: A multicenter, randomized, phase 3 study.
Yuankai SHI ; Qingyuan ZHANG ; Junsheng WANG ; Zhong OUYANG ; Tienan YI ; Jiazhuan MEI ; Xinshuai WANG ; Zhidong PEI ; Tao SUN ; Junheng BAI ; Shundong CANG ; Yarong LI ; Guohong FU ; Tianjiang MA ; Huaqiu SHI ; Jinping LIU ; Xiaojia WANG ; Hongrui NIU ; Yanzhen GUO ; Shengyu ZHOU ; Li SUN
Chinese Medical Journal 2025;138(4):496-498
2.Inhibition of WAC alleviates the chondrocyte proinflammatory secretory phenotype and cartilage degradation via H2BK120ub1 and H3K27me3 coregulation.
Peitao XU ; Guiwen YE ; Xiaojun XU ; Zhidong LIU ; Wenhui YU ; Guan ZHENG ; Zepeng SU ; Jiajie LIN ; Yunshu CHE ; Yipeng ZENG ; Zhikun LI ; Pei FENG ; Qian CAO ; Zhongyu XIE ; Yanfeng WU ; Huiyong SHEN ; Jinteng LI
Acta Pharmaceutica Sinica B 2025;15(8):4064-4077
Several types of arthritis share the common feature that the generation of inflammatory mediators leads to joint cartilage degradation. However, the shared mechanism is largely unknown. H2BK120ub1 was reportedly involved in various inflammatory diseases but its role in the shared mechanism in inflammatory joint conditions remains elusive. The present study demonstrated that levels of cartilage degradation, H2BK120ub1, and its regulator WW domain-containing adapter protein with coiled-coil (WAC) were increased in cartilage in human rheumatoid arthritis (RA) and osteoarthritis (OA) patients as well as in experimental RA and OA mice. By regulating H2BK120ub1 and H3K27me3, WAC regulated the secretion of inflammatory and cartilage-degrading factors. WAC influenced the level of H3K27me3 by regulating nuclear entry of the H3K27 demethylase KDM6B, and acted as a key factor of the crosstalk between H2BK120ub1 and H3K27me3. The cartilage-specific knockout of WAC demonstrated the ability to alleviate cartilage degradation in collagen-induced arthritis (CIA) and collagenase-induced osteoarthritis (CIOA) mice. Through molecular docking and dynamic simulation, doxercalciferol was found to inhibit WAC and the development of cartilage degradation in the CIA and CIOA models. Our study demonstrated that WAC is a key factor of cartilage degradation in arthritis, and targeting WAC by doxercalciferol could be a viable therapeutic strategy for treating cartilage destruction in several types of arthritis.
3.Process parameter optimization and immunogenicity evaluation of calcium phosphate-coated foot-and-mouth disease virus-like particles.
Lihua REN ; Wei GUO ; Qianqian XIE ; Ruipeng LIU ; Shiqi SUN ; Hu DONG ; Yun ZHANG ; Manyuan BAI ; Huichen GUO ; Zhidong TENG
Chinese Journal of Biotechnology 2025;41(7):2672-2681
Bio-mineralization has emerged as a promising strategy to enhance vaccine immunogenicity. This study optimized the calcium phosphate (CaP) mineralization process of foot-and-mouth disease virus-like particles (FMD VLPs) to achieve high mineralization efficiency and scalability. Key parameters, including concentrations of Ca2+, HPO42-, NaCl, and VLPs, as well as stirring speed, were systematically optimized. Stability of the scaled-up reaction system and immunogenicity of the mineralized vaccine were evaluated. Optimal conditions [25.50 mmol/L Ca(NO3)2, 15 mmol/L Na2HPO4, 300 mmol/L NaCl, 0.75 mg/mL VLPs, and 1 500 r/min] yielded CaP-mineralized VLPs (VLPs-CaP) with high mineralization efficiency, uniform morphology, and a favorable particle size. Scaling up the reaction by 25 folds maintained consistent mineralization efficiency and particle characteristics. Immunization in mice demonstrated that VLPs-CaP induced higher titers of specific antibodies and neutralizing antibodies than unmineralized VLPs (P < 0.05). Higher IgG2a/IgG1 ratio and enhanced IFN-γ secretion (P < 0.05) further indicated robust cellular immune responses. We establish a stable and scalable protocol for VLPs-CaP, providing a theoretical and technical foundation for developing high-efficacy VLPs-CaP vaccines.
Vaccines, Virus-Like Particle/immunology*
;
Immunogenicity, Vaccine
;
Calcium Phosphates/chemistry*
;
Foot-and-Mouth Disease Virus
;
Biomineralization
;
Particle Size
;
Animals
;
Mice
;
Antibodies, Neutralizing/blood*
;
Antibodies, Viral/blood*
;
Immunity, Cellular
4.Effects of vacuum freeze-drying based on different lyoprotectants on the stability of foot-and-mouth disease virus-like particles.
Wei GUO ; Qianqian XIE ; Ruipeng LIU ; Hu DONG ; Yun ZHANG ; Xiaoqiang WANG ; Shiqi SUN ; Huichen GUO ; Zhidong TENG
Chinese Journal of Biotechnology 2025;41(7):2682-2693
Vaccination is a crucial strategy for the prevention and control of infectious diseases. Virus-like particles (VLPs), composed of structural proteins, have garnered significant attention as a novel type of vaccine due to their excellent safety and immunogenicity. However, similar to most vaccine antigens, VLPs exhibit insufficient thermal stability, which not only restricts the widespread application of vaccines but also increases the risk of vaccine inactivation. This study aims to enhance the stability and shelf life of VLPs derived from type A foot-and-mouth disease virus (FMDV) by employing vacuum freeze-drying technology. The optimal lyoprotectant formulation was determined through single-factor and combinatorial screening. Subsequently, the correlation between the immunogenicity of the freeze-dried vaccine and the content of FMDV VLPs was evaluated via a mouse model. The stability of FMDV VLPs before and after freeze-drying was further assessed by storing them at 4, 25, and 37 ℃ for varying time periods. Results indicated that the lyoprotectant formulation No.1, composed of 7.5% trehalose, 0.1% Tween 80, 50 mmol/L glycine, 1% sodium glutamate, and 3% polyvinylpyrrolidone (PVP), effectively preserved the content of FMDV VLPs during the vacuum freeze-drying process. The immunization trial in mice revealed that the levels of specific antibodies, immunoglobulin G1 (IgG1), interleukin-4 (IL-4), and neutralizing antibodies induced by freeze-dried FMDV VLPs were comparable to those induced by non-freeze-dried FMDV VLPs. The heat treatment results showed that the storage periods of freeze-dried FMDV VLPs at 4, 25, and 37 ℃ were significantly longer than those of non-freeze-dried FMDV VLPs. In conclusion, the selected lyoprotectant formulation effectively improved the stability of FMDV VLPs vaccines. This study provides valuable insights for enhancing the stability of novel subunit vaccines.
Freeze Drying/methods*
;
Animals
;
Foot-and-Mouth Disease Virus/immunology*
;
Mice
;
Vaccines, Virus-Like Particle/chemistry*
;
Foot-and-Mouth Disease/immunology*
;
Vacuum
;
Drug Stability
;
Mice, Inbred BALB C
;
Viral Vaccines/immunology*
5.Prognosis and its influencing factors in patients with non-gastric gastrointestinal stromal tumors at low risk of recurrence: a retrospective multicenter study in China
Linxi YANG ; Weili YANG ; Xin WU ; Peng ZHANG ; Bo ZHANG ; Junjun MA ; Xinhua ZHANG ; Haoran QIAN ; Ye ZHOU ; Tao CHEN ; Hao XU ; Guoli GU ; Zhidong GAO ; Gang ZHAI ; Xiaofeng SUN ; Changqing JING ; Haibo QIU ; Xiaodong GAO ; Hui CAO ; Ming WANG
Chinese Journal of Gastrointestinal Surgery 2024;27(11):1123-1132
Objective:To investigate the prognosis and the factors that influence it in patients with non-gastric gastrointestinal stromal tumors (GISTs) who are at low risk of recurrence.Methods:This was a retrospective cohort study. Clinicopathologic and prognostic data from patients with non-gastric GISTs and at low risk of recurrence (i.e., very low-risk or low-risk according to the 2008 version of the Modified NIH Risk Classification), who attended 18 medical centers in China between January 2000 and June 2023, were collected. We excluded patients with a history of prior malignancy, concurrent primary malignancy, multiple GISTs, and those who had received preoperative imatinib. The study cohort comprised 1,571 patients with GISTs, 370 (23.6%) of whom were at very low-risk and 1,201 (76.4%) at low-risk of recurrence. The cohort included 799 (50.9%) men and 772 (49.1%) women of median age 57 (16–93) years. Patients were followed up to July 2024. The prognosis and its influencing factors were analyzed. Receiver operating characteristic curves for tumor diameter and Ki67 were established, and the sensitivity, specificity, area under the curve (AUC) and optimal cut-off value with 95% confidence intervals were calculated. Propensity score matching was implemented using the 1:1 nearest neighbor matching method with a matching tolerance of 0.02.Results:With a median follow-up of 63 (12–267) months, the 5- and 10-year overall survival (OS) rates of the 1,571 patients were 99.5% and 98.0%, respectively, and the 5- and 10-year disease-free survival (DFS) rates were 96.3% and 94.4%, respectively. During postoperative follow-up, 3.8% (60/1,571) patients had disease recurrence or metastasis, comprising 0.8% (3/370) in the very low-risk group and 4.7% (57/1,201) in the low-risk group. In the low-risk group, recurrence or metastasis occurred in 5.5% (25/457) of patients with duodenal GISTs, 3.9% (25/645) of those with small intestinal GISTs, 9.2% (6/65) of those with rectal GISTs, and 10.0% (1/10) of those with colonic GISTs. Among the 60 patients with metastases, 56.7% (34/60) of the metastases were located in the abdominal cavity, 53.3% (32/60) in the liver, and 3.3% (2/60) in bone. During the follow-up period, 13 patients (0.8%) died of disease. Receiver operating characteristic curves were plotted for tumor diameter and Ki67 and assessed using the Jordon index. This showed that the difference in DFS between the two groups was statistically significant when the cutoff value for tumor diameter was 3.5 cm (AUC 0.731, 95% CI: 0.670–0.793, sensitivity 77.7%, specificity 64.1%). Furthermore, the difference in DFS between the two groups was statistically significant when the cutoff value for Ki67 was 5% (AUC 0.693, 95% CI: 0.624–0.762, sensitivity 60.7%, specificity 65.3%). Multifactorial analysis revealed that tumor diameter ≥3.5 cm, Ki67 ≥5%, and R1 resection were independent risk factors for DFS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). Furthermore, age >57 years, Ki67 ≥5%, and R1 resection were also independent risk factors for OS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). We also grouped the patients according to whether they had received postoperative adjuvant treatment with imatinib for 1 or 3 years. This yielded 137 patients in the less than 1-year group, 139 in the 1-year plus group; and 44 in both the less than 3 years and 3-years plus group. After propensity score matching for age, tumor diameter, Ki67, and resection status, the differences in survival between the two groups were not statistically significant (all P>0.05). The 10-year DFS and OS were 87.5% and 95.5%, respectively, in the group treated with imatinib for less than 1 year and 88.5% and 97.8%, respectively, in the group treated for more than 1 year. The 10-year DFS and OS were 89.6% and 92.6%, respectively, in the group treated with imatinib for less than 3 years and 88.0% and 100.0%, respectively, in the group treated with imatinib for more than 3 years. Conclusion:The overall prognosis of primary, non-gastric, low recurrence risk GISTs is relatively favorable; however, recurrences and metastases do occur. Age, tumor diameter, Ki67, and R1 resection may affect the prognosis. For some patients with low risk GISTs, administration of adjuvant therapy with imatinib for an appropriate duration may help prevent recurrence and improve survival.
6.Construction of a machine learning model for identifying clinical high-risk carotid plaques based on radiomics
Xiaohui WANG ; Xiaoshuo LÜ ; ; Zhan LIU ; Yanan ZHEN ; Fan LIN ; Xia ZHENG ; Xiaopeng LIU ; Guang SUN ; Jianyan WEN ; Zhidong YE ; Peng LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(01):24-34
Objective To construct a radiomics model for identifying clinical high-risk carotid plaques. Methods A retrospective analysis was conducted on patients with carotid artery stenosis in China-Japan Friendship Hospital from December 2016 to June 2022. The patients were classified as a clinical high-risk carotid plaque group and a clinical low-risk carotid plaque group according to the occurrence of stroke, transient ischemic attack and other cerebrovascular clinical symptoms within six months. Six machine learning models including eXtreme Gradient Boosting, support vector machine, Gaussian Naive Bayesian, logical regression, K-nearest neighbors and artificial neural network were established. We also constructed a joint predictive model combined with logistic regression analysis of clinical risk factors. Results Finally 652 patients were collected, including 427 males and 225 females, with an average age of 68.2 years. The results showed that the prediction ability of eXtreme Gradient Boosting was the best among the six machine learning models, and the area under the curve (AUC) in validation dataset was 0.751. At the same time, the AUC of eXtreme Gradient Boosting joint prediction model established by clinical data and carotid artery imaging data validation dataset was 0.823. Conclusion Radiomics features combined with clinical feature model can effectively identify clinical high-risk carotid plaques.
7.Discovery of a normal-tension glaucoma-suspect rhesus macaque with craniocerebral injury: Hints of elevated translaminar cribrosa pressure difference.
Jian WU ; Qi ZHANG ; Xu JIA ; Yingting ZHU ; Zhidong LI ; Shu TU ; Ling ZHAO ; Yifan DU ; Wei LIU ; Jiaoyan REN ; Liangzhi XU ; Hanxiang YU ; Fagao LUO ; Wenru SU ; Ningli WANG ; Yehong ZHUO
Chinese Medical Journal 2024;137(4):484-486
8.Effects of miR-155 on apoptosis of chronic myeloid leukemia cells and expression of heat shock proteins
Yingli Ren ; Zhidong Chen ; Beibei Sun ; Jie Yao ; Fan Ma ; Qiang Zhou
Acta Universitatis Medicinalis Anhui 2024;59(1):34-39
Objective :
To explore the effects of microRNA-155 (miR-155) on apoptosis of chronic myeloid leukemia ( CML) cells,and the influence of miRNA-155 regulating the expression of heat shock proteins ( HSP) 27, HSP60,HSP70.
Methods :
Reverse transcription-quantitative real-time PCR ( RT-qPCR) was used to detect the expression levels of miR-155 in CML-resistant imatinib (IM) cell line K562-G and CML cell line K562 .K562-G cells were infected with the lentivirus carrying miR-155 or the negative control lentivirus ,and they were named miR-155 group and control group.The effect of miR-155 on the proliferation of drug-resistant cells was detected by cell counting kit-8 ( CCK-8) method. RT-qPCR and Western blot were used to detect the effect of miR-155 on the expression of heat shock proteins HSP27,HSP60,HSP70.Flow cytometry was used to detect the percentage of cell apoptosis in miR-155 group and control group.
Results :
ompared with K562 cells,miR-155 showed low expres- sion in K562-G cells (P <0. 05) .The proliferation of miR-155 group cells decreased significantly from the 36th hour (P<0. 05) .Compared with the control group,in the miR-155 group,HSP60 and HSP70 increased (P < 0. 05) ,while HSP27 decreased (P<0. 01) .The apoptosis rate of miR-155 group was higher than that of control group (P<0. 05) .
Conclusion
miR-155 promotes the apoptosis of chronic myeloid leukemia cells,increases the expression of HSP60 and HSP70,and decreases the expression of HSP27 .
9.Prognosis and its influencing factors in patients with non-gastric gastrointestinal stromal tumors at low risk of recurrence: a retrospective multicenter study in China
Linxi YANG ; Weili YANG ; Xin WU ; Peng ZHANG ; Bo ZHANG ; Junjun MA ; Xinhua ZHANG ; Haoran QIAN ; Ye ZHOU ; Tao CHEN ; Hao XU ; Guoli GU ; Zhidong GAO ; Gang ZHAI ; Xiaofeng SUN ; Changqing JING ; Haibo QIU ; Xiaodong GAO ; Hui CAO ; Ming WANG
Chinese Journal of Gastrointestinal Surgery 2024;27(11):1123-1132
Objective:To investigate the prognosis and the factors that influence it in patients with non-gastric gastrointestinal stromal tumors (GISTs) who are at low risk of recurrence.Methods:This was a retrospective cohort study. Clinicopathologic and prognostic data from patients with non-gastric GISTs and at low risk of recurrence (i.e., very low-risk or low-risk according to the 2008 version of the Modified NIH Risk Classification), who attended 18 medical centers in China between January 2000 and June 2023, were collected. We excluded patients with a history of prior malignancy, concurrent primary malignancy, multiple GISTs, and those who had received preoperative imatinib. The study cohort comprised 1,571 patients with GISTs, 370 (23.6%) of whom were at very low-risk and 1,201 (76.4%) at low-risk of recurrence. The cohort included 799 (50.9%) men and 772 (49.1%) women of median age 57 (16–93) years. Patients were followed up to July 2024. The prognosis and its influencing factors were analyzed. Receiver operating characteristic curves for tumor diameter and Ki67 were established, and the sensitivity, specificity, area under the curve (AUC) and optimal cut-off value with 95% confidence intervals were calculated. Propensity score matching was implemented using the 1:1 nearest neighbor matching method with a matching tolerance of 0.02.Results:With a median follow-up of 63 (12–267) months, the 5- and 10-year overall survival (OS) rates of the 1,571 patients were 99.5% and 98.0%, respectively, and the 5- and 10-year disease-free survival (DFS) rates were 96.3% and 94.4%, respectively. During postoperative follow-up, 3.8% (60/1,571) patients had disease recurrence or metastasis, comprising 0.8% (3/370) in the very low-risk group and 4.7% (57/1,201) in the low-risk group. In the low-risk group, recurrence or metastasis occurred in 5.5% (25/457) of patients with duodenal GISTs, 3.9% (25/645) of those with small intestinal GISTs, 9.2% (6/65) of those with rectal GISTs, and 10.0% (1/10) of those with colonic GISTs. Among the 60 patients with metastases, 56.7% (34/60) of the metastases were located in the abdominal cavity, 53.3% (32/60) in the liver, and 3.3% (2/60) in bone. During the follow-up period, 13 patients (0.8%) died of disease. Receiver operating characteristic curves were plotted for tumor diameter and Ki67 and assessed using the Jordon index. This showed that the difference in DFS between the two groups was statistically significant when the cutoff value for tumor diameter was 3.5 cm (AUC 0.731, 95% CI: 0.670–0.793, sensitivity 77.7%, specificity 64.1%). Furthermore, the difference in DFS between the two groups was statistically significant when the cutoff value for Ki67 was 5% (AUC 0.693, 95% CI: 0.624–0.762, sensitivity 60.7%, specificity 65.3%). Multifactorial analysis revealed that tumor diameter ≥3.5 cm, Ki67 ≥5%, and R1 resection were independent risk factors for DFS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). Furthermore, age >57 years, Ki67 ≥5%, and R1 resection were also independent risk factors for OS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). We also grouped the patients according to whether they had received postoperative adjuvant treatment with imatinib for 1 or 3 years. This yielded 137 patients in the less than 1-year group, 139 in the 1-year plus group; and 44 in both the less than 3 years and 3-years plus group. After propensity score matching for age, tumor diameter, Ki67, and resection status, the differences in survival between the two groups were not statistically significant (all P>0.05). The 10-year DFS and OS were 87.5% and 95.5%, respectively, in the group treated with imatinib for less than 1 year and 88.5% and 97.8%, respectively, in the group treated for more than 1 year. The 10-year DFS and OS were 89.6% and 92.6%, respectively, in the group treated with imatinib for less than 3 years and 88.0% and 100.0%, respectively, in the group treated with imatinib for more than 3 years. Conclusion:The overall prognosis of primary, non-gastric, low recurrence risk GISTs is relatively favorable; however, recurrences and metastases do occur. Age, tumor diameter, Ki67, and R1 resection may affect the prognosis. For some patients with low risk GISTs, administration of adjuvant therapy with imatinib for an appropriate duration may help prevent recurrence and improve survival.
10.Research and application analysis of technical support strategy of large medical equipment based on the perspective of metrological safety
Pengfei WANG ; Zhidong SUN ; Xiaochen ZHAO ; Liwen CHI ; Yangyang LI
China Medical Equipment 2024;21(11):121-125,136
Objective:To construct a metrological safety evaluation model for large medical equipment based on the perspective of metrological safety,and to explore its application value in the management of large medical equipment.Methods:According to the different safety risk sources,the diagnosis and treatment area of large medical equipment was divided into five types:light source,electricity,water,radiation and information.The metrological safety assessment indicators were empowered by combining subjective and objective methods,and engineering support strategies were developed according to the metrological safety levels and safety change trends.A total of 48 large medical equipment in clinical use in The 960th Hospital of PLA Joint Logistic Support Force from 2020 to 2023 were selected.The 42 sets of equipment used during 2020 to 2021 adopted the conventional fault maintenance support mode(referred to as the conventional support mode),and the 43 sets of equipment used from 2022-2023(including 37 in conventional mode and 6 newly added)adopted the metrology safety technical support mode(referred to as metrology safety support mode).The metrology safety management ability score,metrological inspection qualification levels and metrological safety management effects of large medical equipment were compared between the two management modes.Results:The evaluation scores of theoretical knowledge,safety awareness,practical operation and emergency level indicators of large medical equipment use management personnel of the metrology safety support model were(17.39±1.38)points,(17.87±1.08)points,(27.68±1.45)points and(27.96±1.24)points,respectively,which were higher than those of the conventional support mode,the difference was statistically significant(t=4.234,4.371,5.832,3.764,P<0.05).The average metrological inspection qualified rates(%)of medical imaging equipment,life support equipment,clinical laboratory equipment,operating room equipment and other equipment using the metrology safety support mode were(95.19±2.56)%,(95.56±1.79)%,(94.64±2.42)%,(96.20±2.01)%and(93.46±2.22)%,respectively,which were higher than those of the conventional support mode,the difference was statistically significant(t=3.846,2.809,2.405,2.492,2.742,P<0.05).The proportion of large medical equipment rated as high safety level and low safety level in the metrological safety support model were 67.44%(29/43)and 4.65%(2/43),respectively,the proportion of high safety level was higher than that in the conventional support mode,and the proportion of low safety level was lower than that in the conventional support mode,the difference was statistically significant(x2=4.261,7.085,P<0.05).Conclusion:The large medical equipment metrological safety support mode based on the safety perspective can improve the safety management ability of personnel related to equipment use and management,improve the operation quality and performance level of equipment,increase the proportion of high-safety level metrology safety of large medical equipment,and reduce the proportion of low-safety level.


Result Analysis
Print
Save
E-mail