1.Association of polychlorinated biphenyl exposure with platelet parameters across different glycemic states: The moderating role of a healthy lifestyle
Zhuo CHEN ; Huilin LOU ; Taimeng CHEN ; Fangyuan LIN ; Xueyan WU ; Yao GUO ; Haoran XU ; Mengke CHENG ; Peihan CHEN ; Yilin ZHOU ; Zhenxing MAO ; Xin TANG
Journal of Environmental and Occupational Medicine 2026;43(5):535-541
Background Platelet parameters are important indicators of cardiovascular risk, and environmental pollutants such as polychlorinated biphenyls (PCBs) may impair platelet function through oxidative stress. Objective To investigate the differential effects of single and mixed exposure to PCBs on platelet parameters among individuals with normal glucose tolerance (NGT), impaired fasting glucose (IFG), and type 2 diabetes mellitus (T2DM), and to evaluate the potential modifying role of a healthy lifestyle. Methods This study included 2249 participants (including 707 with NGT, 759 with IFG, and 783 with T2DM). Plasma PCB concentrations were measured using triple quadrupole gaschromatography-tandem mass spectrometry. Generalized linear regression was used to assess the associations between individual PCB congeners and platelet parameters. Quantile g-computation (QGC) and Bayesian kernel machine regression (BKMR) models were used to evaluate the overall effects of PCBs mixture exposure on platelet parameters across different glycemic states, as well as its interaction with healthy lifestyle score (HLS). Results Generalized linear regression analyses showed significant differences in the effects of PCBs on platelet parameters across different glycemic states (P<0.05). After adjusting for confounders, PCBs mixture exposure was significantly associated with lower platelet counts (PLT) in individuals with NGT (b=−10.60, 95%CI: −16.48, −4.71) and IFG (b=−12.91, 95%CI: −18.90, −6.92), whereas no significant association was observed in individuals with T2DM (P=0.051). Mean platelet volume (MPV) and platelet-large cell ratio (P-LCR) increased significantly with higher PCBs exposure levels across all three groups (P<0.05). BKMR analysis showed a positive association between PCBs mixture exposure and P-LCR, with the strongest association observed in the NGT group. Furthermore, a significant interaction was observed between HLS and PCBs mixture exposure, and a higher HLS attenuated the effects of PCBs on P-LCR. Conclusion Glycemic glycemic states may modify the effects of PCBs on platelets. Individuals with NGT appear more sensitive to PCBs exposure, whereas the T2DM state may attenuate this effect. Moreover, healthy lifestyles, including not smoking, moderate alcohol consumption, maintaining moderate-to-high physical activity, a healthy diet, and an appropriate body mass index (BMI), may mitigate the adverse effects of most PCBs on platelet parameters.
2.Association of polychlorinated biphenyl exposure with platelet parameters across different glycemic states: The moderating role of a healthy lifestyle
Zhuo CHEN ; Huilin LOU ; Taimeng CHEN ; Fangyuan LIN ; Xueyan WU ; Yao GUO ; Haoran XU ; Mengke CHENG ; Peihan CHEN ; Yilin ZHOU ; Zhenxing MAO ; Xin TANG
Journal of Environmental and Occupational Medicine 2026;43(5):535-541
Background Platelet parameters are important indicators of cardiovascular risk, and environmental pollutants such as polychlorinated biphenyls (PCBs) may impair platelet function through oxidative stress. Objective To investigate the differential effects of single and mixed exposure to PCBs on platelet parameters among individuals with normal glucose tolerance (NGT), impaired fasting glucose (IFG), and type 2 diabetes mellitus (T2DM), and to evaluate the potential modifying role of a healthy lifestyle. Methods This study included 2249 participants (including 707 with NGT, 759 with IFG, and 783 with T2DM). Plasma PCB concentrations were measured using triple quadrupole gaschromatography-tandem mass spectrometry. Generalized linear regression was used to assess the associations between individual PCB congeners and platelet parameters. Quantile g-computation (QGC) and Bayesian kernel machine regression (BKMR) models were used to evaluate the overall effects of PCBs mixture exposure on platelet parameters across different glycemic states, as well as its interaction with healthy lifestyle score (HLS). Results Generalized linear regression analyses showed significant differences in the effects of PCBs on platelet parameters across different glycemic states (P<0.05). After adjusting for confounders, PCBs mixture exposure was significantly associated with lower platelet counts (PLT) in individuals with NGT (b=−10.60, 95%CI: −16.48, −4.71) and IFG (b=−12.91, 95%CI: −18.90, −6.92), whereas no significant association was observed in individuals with T2DM (P=0.051). Mean platelet volume (MPV) and platelet-large cell ratio (P-LCR) increased significantly with higher PCBs exposure levels across all three groups (P<0.05). BKMR analysis showed a positive association between PCBs mixture exposure and P-LCR, with the strongest association observed in the NGT group. Furthermore, a significant interaction was observed between HLS and PCBs mixture exposure, and a higher HLS attenuated the effects of PCBs on P-LCR. Conclusion Glycemic glycemic states may modify the effects of PCBs on platelets. Individuals with NGT appear more sensitive to PCBs exposure, whereas the T2DM state may attenuate this effect. Moreover, healthy lifestyles, including not smoking, moderate alcohol consumption, maintaining moderate-to-high physical activity, a healthy diet, and an appropriate body mass index (BMI), may mitigate the adverse effects of most PCBs on platelet parameters.
3.Network framework for PET tumor segmentation driven by geodesic image prior
Lin YANG ; Dan SHAO ; Zhenxing HUANG ; Dong LIANG ; Hairong ZHENG ; Zhanli HU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(4):234-239
Objective:To construct a prior based on the inherent properties of PET to accurately segment the lesion areas.Methods:A network framework for PET tumor segmentation driven by geodesic priors was proposed (geodesic network for short). Specifically, partial differential equations were constructed to characterize the geodesic distances between different regions in PET images. Tumor marker points identified by CT labeling were used as the initial conditions for the equations. To enhance the contrast between areas of lung or breast tumors and normal tissues, a smooth Heaviside function was utilized to map the geodesic distances. The network framework adopted a dual-branch architecture, using geodesic priors to assist in PET image segmentation.Results:The proposed method achieved a Dice coefficient of 94.92% in lung cancer segmentation and 90.12% in breast cancer segmentation. With the addition of geodesic priors in the Unet, the Dice coefficient for breast cancer increased by 32.37% (from 42.50% to 74.87%).Conclusion:Geodesic priors can significantly improve segmentation outcomes and enhance the generalization capability of the network.
4.Network framework for PET tumor segmentation driven by geodesic image prior
Lin YANG ; Dan SHAO ; Zhenxing HUANG ; Dong LIANG ; Hairong ZHENG ; Zhanli HU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(4):234-239
Objective:To construct a prior based on the inherent properties of PET to accurately segment the lesion areas.Methods:A network framework for PET tumor segmentation driven by geodesic priors was proposed (geodesic network for short). Specifically, partial differential equations were constructed to characterize the geodesic distances between different regions in PET images. Tumor marker points identified by CT labeling were used as the initial conditions for the equations. To enhance the contrast between areas of lung or breast tumors and normal tissues, a smooth Heaviside function was utilized to map the geodesic distances. The network framework adopted a dual-branch architecture, using geodesic priors to assist in PET image segmentation.Results:The proposed method achieved a Dice coefficient of 94.92% in lung cancer segmentation and 90.12% in breast cancer segmentation. With the addition of geodesic priors in the Unet, the Dice coefficient for breast cancer increased by 32.37% (from 42.50% to 74.87%).Conclusion:Geodesic priors can significantly improve segmentation outcomes and enhance the generalization capability of the network.
5.Summary of lapse analysis and experience with CT-guided percutaneous lung biopsy
Zhenxing DING ; Yongle HOU ; Shengjie LIU ; Lin LI
Journal of Practical Radiology 2024;40(2):293-296
Objective To investigate the complications of CT-guided percutaneous lung biopsy(CT-PTNB)and its correlation with improper operation.Methods The clinical data of 360 patients who underwent lung tumor needle biopsy were collected.The complications occurred in the process of needle biopsy and their correlation with improper operation were summarized,and the experience was further summarized to increase the success rate of needle biopsy and reduce the occurrence of complications.Results Biopsy tissue was successfully obtained in all 360 patients.There were 84 cases with complications after puncture,including 67 cases with pneumothorax,59 cases with hemorrhage(5 cases with hemoptysis,59 cases with needle tract hemorrhage with pulmonary hemorrhage,6 cases with intrathoracic hemorrhage),9 cases with subcutaneous emphysema of chest wall,and 3 cases with chest wall puncture point pain,and all patients did not undergo surgical treatment.All patients recovered from symptomatic treatment such as bed rest,hemostasis,anti-inflammatory and oxygen inhalation.Only 6 patients with pneumothorax had increased volume of pneumothorax after operation and underwent closed thoracic drainage,and all of them were decannulated successfully.No air embolism and other rare complications occurred.Conclusion The appropriate puncture path should be selected according to the different conditions of the patient.At the same time,the anatomy of the chest wall and lung should be familiar with,and pay attention to all the details of the needle biopsy process to reduce the occurrence of errors.
6.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
7.Characteristics of whole blood donors from 26 blood stations before and after the outbreak of COVID-19:a multicenter study
Peng LI ; Youhua SHEN ; Wei GAO ; Wei ZHANG ; Jianling ZHONG ; Hao LI ; Lin BAO ; Ying WANG ; Xuefang FENG ; Tao SUN ; Xiaoqin CHEN ; Li LI ; Hongzhi JIA ; Shouguang XU ; Xiaobo CAI ; Wen ZHANG ; Qunying LAI ; Zhiqiang YU ; Zhenxing WANG ; Yanjun ZHOU ; Peng WANG ; Yanhua ZHANG ; Guoqiang ZHANG ; Haiying NIU ; Hongli JING
Chinese Journal of Blood Transfusion 2023;36(10):907-912
【Objective】 To analyze the basic characteristics of whole blood donors from blood stations before and after the outbreak of COVID-19. 【Methods】 After excluding invalid data, data related to the basic characteristics of whole blood donors collected from 26 blood stations in China during 2018 to 2021 were statistically analyzed, including the trend of total whole blood donors, the number of repeated blood donors, the frequency of blood donation, the average age of donors and the recruitment of first-time blood donors. 【Results】 Affected by the epidemic, 8 out of 14 indicators were with large variations, accounting for 57%. The overall growth rate of total whole blood donors during the epidemic was higher than before the epidemic (P<0.05).The number of repeated blood donors has shown an increased trend, with a higher number during the epidemic than before (P<0.05). The frequency of blood donation was lower during the epidemic than before(P<0.05).Average ages of blood donors and female blood donors fluctuated widely during the epidemic, both higher than those before the epidemic(P<0.05).The donation rate of first-time blood donors <25 years old and ≥25 years old varied widely and irregularly during the epidemic (both P<0.05). The percentage of first-time blood donors fluctuated irregularly during the epidemic, with overall percentage lower than that before the epidemic(P<0.05). 【Conclusion】 Whole blood donors from 26 blood stations increased after the outbreak of COVID-19, and some indicators in certain areas showed significant fluctuations during the epidemic.
8.Short-term clinical and echocardiographic outcomes of the novel domestic transcatheter edge-to-edge repair Neonova? system in patients with mitral regurgitation
Yun YANG ; He LI ; Wenqian WU ; Xiaoke SHANG ; Shu CHEN ; Yucheng ZHONG ; Manwei LIU ; Lin HE ; Zhenxing SUN ; Ziming ZHANG ; Yi ZHOU ; Xin ZHANG ; Nianguo DONG ; Lingyun FANG ; Mingxing XIE
Chinese Journal of Ultrasonography 2023;32(1):51-59
Objective:To investigate short-term safety, efficacy and the learning curve of this self-developed novel transcatheter valve repair system (Neonova?) in patients with mitral regurgitation, and explore the role of perioperative echocardiography.Methods:Ten patients who visited the Union Hospital of Tongji Medical College, Huazhong University of Science and Technology from June 2021 to March 2022 and met the inclusive criteria were prospectively enrolled. All the patients were at high risk of surgery with moderate to severe or severe mitral regurgitation (MR). Clamps of Neonova? were implanted under guidance of transesophageal echocardiography and digital subtraction angiography. Clinical outcomes, echocardiography indexes and learning curves of this technique were evaluated immediately after intervention, 7 d, 1 month and 3 months post-intervention.Results:The technical success rate was 100% with MR relieved in all patients immediately after intervention. The device and procedural success rates were both 90.0% with 1 patient received surgical replacement at 37 days post-intervention while the others′ reduced to mild (8/9) and moderate (1/9) MR. New York Heart Association class and the Kansas City Cardiomyopathy Questionnaire improved significantly (all P<0.001). Mean mitral valve pressure gradient didn′t increase significantly after intervention when compared with that before intervention( P=0.324), and no mitral stenosis was observed. Left ventricular end-diastolic diameter decreased significantly ( P=0.008) during follow up.Procedure duration ranged from 60 to 300 (175.8±75.2)minutes. The simple linear regression model between procedure volume and duration showed that procedure duration decreased significantly with the increase of procedure volume ( F=15.857, P=0.004). Conclusions:Neonova? implantation can improve MR severity and clinical symptoms safely and effectively. Transthoracic echocardiography and transesophageal echocardiography are essential for perioperative management of transcatheter mitral valve repair.
9.Analysis of the unqualified HCV detection results of blood donors from the served area of 22 domestic blood institutions
Zhongsi YANG ; Shouguang XU ; Wei ZHANG ; Jian ZHANG ; Xiaojie LIU ; Feng YANG ; Qin WANG ; Yanqin HE ; Lin BAO ; Zhiqiang YU ; Zhenxing WANG ; Changwen QIU ; Xiaobo CAI ; Li LI ; Peng WANG ; Zhanfeng XU ; Furong YU ; Chao ZHAO ; Jiankang WANG ; Youhua SHEN ; Jingjing BAO ; Jun ZHOU ; Yan QIU
Chinese Journal of Experimental and Clinical Virology 2023;37(4):367-372
Objective:To investigate the unqualified hepatitis C virus (HCV) detection result of blood donors from the served area of blood institutions.Methods:The data related to HCV markers detected of the first and repeat blood donors were collected from the system of practice comparison for the Chinese mainland blood institutions from 2017 to 2021. The anti-HCV reactive rate and the rates of anti-HCV negative but HCV-RNA reaction and all the relationship between rates and the annual, regional and different blood donors were statistically analyzed.Results:During 2017-2021, the number of anti-HCV reactive per 100 000 blood donors decreased from 444.3 to 250.44 in the served area of 22 blood institutions ( χ2=49.677, P<0.05). The number of HCV RNA detected positive per 100 000 anti-HCV negative increased from 0.69 to 2.05 year by year, but there was no statistical significance ( χ2=0.643, P>0.05). The anti-HCV unqualified rate was significantly different among regions ( χ2=3 260.283, P<0.05). The anti-HCV unqualified rate of the first blood donors was significantly higher than that of the repeated blood donors ( F=130.993, P < 0.05). The annual number of HCV RNA detected positive per 100 000 anti-HCV negative blood samples from donors ranged from 0 to 17.28. Conclusions:The anti-HCV unqualified rate of blood donors in the served area of 22 blood institutions decreased year by year. Compared with repeated blood donors, HCV infection should be emphasized in first-time blood donors. The implementation of HCV RNA test can detect out much more HCV infections and reduce the risk of transfusion transmitted infectious HCV.
10.Echocardiographic evaluation of the domestic D-Shant device for treatment of patients with chronic heart failure
Yi ZHOU ; He LI ; Yuman LI ; Lingyun FANG ; Jie LIU ; Wenqian WU ; Zhenxing SUN ; Ziming ZHANG ; Lin HE ; Yihan CHEN ; Yuji XIE ; Xiaoke SHANG ; Nianguo DONG ; Mingxing XIE
Chinese Journal of Ultrasonography 2022;31(9):737-745
Objective:To evaluate the efficacy of the domestic D-Shant device for the treatment of patients with chronic heart failure (CHF) using echocardiography.Methods:Twenty-four CHF patients who were treated with domestic D-Shant device in Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from September 2020 to December 2021 were enrolled in the study. Pulmonary capillary wedge pressure (PCWP)/ left atrial pressure (LAP), right atrial pressure (RAP), pulmonary artery pressure, interatrial septal gradient pressure, cardiac index and pulmonary/systemic blood flow ratio (Qp/Qs) were measured before and after implantation using right heart catheterization.Left atrial end-diastolic area index (LAEDAI), left atrial end-diastolic volume index (LAEDVI), left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), left ventricular ejection fraction (LVEF), right atrial end-diastolic diameter, right ventricular end-diastolic diameter, tricuspid annular plane systolic excursion (TAPSE), right ventricular tractional area change (RVFAC), device shunt aperture, velocity and pressure, together with mitral and tricuspid regurgitation severity were measured using echocardiography before, and 1 month as well as 3 months after D-Shant device implantation. Clinical data were collected and analyzed including 6-minute walking test (6MWT), New York Heart Association (NYHA) classification and the Kansas City Cardiomyopathy Questionnaire (KCCQ). Spearman correlation analysis was used to determine the relation between the changes in PCWP/LAP as well as echocardiographic parameters before and 3 months after implantation and NYHA classification. Binary Logistic regression analysis was performed to determine the predictive factors of NYHA classification improvement at 3-month follow-up after D-Shant device implantation.Results:①D-Shant devices were successfully implanted in all patients. ②Compared with preoperative values, invasive PCWP/LAP systolic, diastolic and mean pressures, transatrial septal gradient, and pulmonary systolic, diastolic and mean pressures decreased significantly after implantation(all P<0.001); Qp/Qs increased significantly after implantation( P<0.001). ③Compared with preoperative values, TAPSE, RVFAC and pulmonary artery flow velocity increased at 1 month after implantation(all P<0.05), whereas a significant reduction in mitral regurgitation grade, and an increase in LVEF and pulmonary artery flow velocity at 3 months after implantation(all P<0.05). Right atrial end-diastolic diameter, right ventricular end-diastolic diameter, LAEDAI, LAEDVI, LVEDVI, LVESVI, ratio of early to late diastolic peak velocities of mitral inflow(E/A), systolic peak velocity of mitral annulus at septal site(S′), ratio of early diastolic peak velocity of mitral inflow to diastolic peak velocity of mitral annulus(E/e′), pulmonary artery diameter, inferior vena cava diameter and degree of tricuspid regurgitation did not change among before, and 1 month as well as 3 months after implantation. There were no significant changes in the device shunt aperture, velocity and pressure between 1 month and 3 months after implantation(all P>0.05). ④The significant improvements in NYHA classification, KCCQ scores and 6MWT were observed at 1 and 3 months after implantation compared with preoperative values (all P<0.01). ⑤NYHA classification at 3 months after implantation was correlated with LVEF pre-post, PCWP/LAP pre-post, TAPSE pre-post and RVFAC pre-post ( rs=0.738, -0.730, 0.738, 0.723; all P<0.001). Logistic regression analysis showed that LVEF pre-post was an independent predictor for NYHA classification improvement at 3 months after implantation ( OR=0.687, 95% CI=0.475-0.992, P=0.045) . Conclusions:Domestic D-Shant device can effectively improve the cardiac function and clinical symptoms in patients with CHF. Echocardiography is a feasible and effective method to evaluate the benefits of domestic D-Shant device for the treatment of CHF.

Result Analysis
Print
Save
E-mail