1.Quality of leukoreduced pooled concentrated platelets prepared from whole blood under different storage temperatures and durations
Huijuan AN ; Hong SHAN ; Zheng LIU ; Jiaojiao ZHANG ; Jiaojie WANG ; Lili BIE ; Min LIU
Chinese Journal of Blood Transfusion 2026;39(5):603-609
Objective: To compare the in vitro quality differences of leukoreduced pooled concentrated platelets prepared from whole blood preserved at different temperatures and for various durations, determine the safe time window for refrigerated whole blood in platelet preparation, and provide experimental evidence for optimizing blood component preparation procedures and improving the comprehensive utilization rate of blood resources. Methods: A total of 324 units of 400 mL ACD-B anticoagulated whole blood were randomly divided into two groups and stored at 4℃ and 22℃, respectively. The buffy coat was separated at three time intervals: <6 h, 6-12 h, and >12 h (≤18 h) post-collection, and allowed to rest overnight at 22℃. On the following day, the buffy coats from each group were pooled to prepare leukoreduced pooled platelet concentrates (LPPCs). Cell counts were performed, and metabolic parameters including pH, glucose, and lactate levels were measured to evaluate metabolic status. Platelet in vitro function and activation were assessed by thromboelastography (TEG), platelet aggregation rate, and the expression of PAC-1 and CD62P. The differences between the two groups were compared. Results: For pooled concentrated platelets prepared from whole blood stored at 4℃ and 22℃ for <6 h and 6-12 h, there were no significant differences in platelet count, pH, glucose levels, lactic acid levels, thromboelastography (TEG), platelet aggregation rate, or platelet activation rate (P>0.05). With prolonged refrigeration time of whole blood, compared with pooled concentrated platelets prepared from whole blood stored at 22℃ for >12 h but ≤18 h, those prepared from whole blood stored at 4℃ for >12 h but ≤18 h showed a decreased platelet count (1 152.83±180.08 vs 1 368.83±134.86, P=0.040), a significantly increased ADP-induced aggregation rate (26.82±6.59 vs 13.88±10.21, P=0.030), and significantly elevated expression rates of PAC-1 and CD62P (72.64±6.74 vs 63.28±5.97, P=0.030). However, there were no significant differences in pH, glucose content, lactate content, or thromboelastography (P>0.05). Conclusion: There was no significant difference in the in vitro count, function, or activation of pooled concentrated platelets prepared from whole blood stored at 4℃ and 22℃ within 12 hours. However, statistically significant differences were observed between the mixed concentrated platelets prepared from whole blood stored at 4℃ and those stored at 22℃ for more than 12 hours but not exceeding 18 hours. These findings can provide a reference for the preparation methods and clinical application of refrigerated platelets.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.Clinical Advantages of Traditional Chinese Medicine in Treatment of Childhood Simple Obesity: Insights from Expert Consensus
Qi ZHANG ; Yingke LIU ; Xiaoxiao ZHANG ; Guichen NI ; Heyin XIAO ; Junhong WANG ; Liqun WU ; Zhanfeng YAN ; Kundi WANG ; Jiajia CHEN ; Hong ZHENG ; Xinying GAO ; Liya WEI ; Qiang HE ; Qian ZHAO ; Huimin SU ; Zhaolan LIU ; Dafeng LONG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):238-245
Childhood simple obesity has become a significant public health issue in China. Modern medicine primarily relies on lifestyle interventions and often suffers from poor long-term compliance, while pharmacological options are limited and associated with potential adverse effects. Traditional Chinese Medicine (TCM) has a long history in the prevention and management of this condition, demonstrating eight distinct advantages, including systematic theoretical foundation, diversified therapeutic approaches, definite therapeutic efficacy, high safety profile, good patient compliance, comprehensive intervention strategies, emphasis on prevention, and stepwise treatment protocols. Additionally, TCM is characterized by six distinctive features: the use of natural medicinal substances, non-invasive external therapies, integration of medicinal dietetics, simple exercise regimens, precise syndrome differentiation, and diverse dosage forms. By combining internal and external treatments, TCM facilitates individualized regimen adjustment and holistic regulation, demonstrating remarkable effects in improving obesity-related metabolic indicators, regulating constitutional imbalance, and promoting healthy behaviors. However, challenges remain, such as inconsistent operational standards, insufficient high-quality clinical evidence, and a gap between basic research and clinical application. Future efforts should focus on accelerating the standardization of TCM diagnosis and treatment, conducting multicenter randomized controlled trials, and fostering interdisciplinary integration, so as to enhance the scientific validity and international recognition of TCM in the prevention and treatment of childhood obesity.
4.Differences in Responses to Neoadjuvant Anti-HER2 Therapy between HER2 2+/ISH+ and HER2 3+ in HER2-Positive Breast Cancer
Lingjun MA ; Ran ZHENG ; Lingyun XU ; Ying ZHU ; Hong YIN ; Xiaoqing ZHANG ; Rong DENG ; Jue WANG ; Xiaoming ZHA
Cancer Research and Treatment 2026;58(2):501-512
Purpose:
Dual anti–human epidermal growth factor receptor 2 (HER2) drugs have become the standard regimen for neoadjuvant systemic treatment (NST) to HER2-positive breast cancer patients. However, the efficacy varies greatly among patients with different HER2 protein expression levels.
Materials and Methods:
A total of 575 HER2-positive breast cancer patients from multiple centers throughout China from 2013 to 2022 were retrospectively analyzed. We compared clinicopathological features in different HER2 immunohistochemistry classes (HER2 2+/in situ hybridization [ISH] + or HER2 3+), and their difference in response to NST and survival with single or dual anti-HER2 drugs. Drug sensitivity assays were used to evaluate different efficacy of anti-HER2 drugs in vitro.
Results:
Compared to HER2 3+ subgroup, the HER2 2+/ISH+ group had a higher proportion of hormone receptor–positive status (48.7% vs. 76.1%, p < 0.001), more HER2 protein loss after NST, lower pathological complete response (pCR) rate (46.07% vs. 16.24%, p < 0.001), and tended to have worse disease-free survival (DFS). In HER2 2+/ISH+ patients, treated with pertuzumab and trastuzumab in combination had no significant improvement in pCR (19.12% vs. 12.24%, p=0.287) and DFS (p=0.908) than using alone. Drug sensitivity assay showed poor efficacy with dual anti-HER2 drugs in HER2 2+/ISH+ cell lines; however, fam-trastuzumab deruxtecan drugs had a satisfactory effect.
Conclusion
Owing to the differences in clinicopathological features and treatment efficacy, we considered the HER2 2+/ISH+ group to be a distinct subtype and defined it as the HER2-moderate–positive subgroup. In this subgroup, dual anti-HER2 drugs did not exert significant improvement in pCR and DFS. Therefore, treatment optimization is warranted, with antibody-drug conjugate drugs as potential options.
5.Construction of a biomimetic three-layered PLLA/PCL large-diameter vessel via electrospinning and ultrasonic pore-forming: Preliminary animal evaluation
Wenjun WANG ; Yang GAO ; Feng GAO ; Lei SHI ; Wei LIU ; Weiwang FAN ; Chang XU ; Hong ZHENG ; Xufeng DONG ; ZHUANG Xijing
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(07):1093-1100
Objective To fabricate a large-diameter vascular graft with a pore size gradient structure mimicking that of natural blood vessels, using poly-L-lactic acid (PLLA) and polycaprolactone (PCL) as base materials through electrospinning and ultrasonic pore-forming techniques, and to evaluate its application potential. Methods A three-layered tubular graft was fabricated from a PCL/PLLA blend (mass ratio 6 : 4) via electrospinning, followed by an ultrasonic pore-forming process to create a gradient porosity. The resulting graft (diameter: 2 cm, length: 4 cm) was implanted into the descending thoracic aorta of an experimental pig using an end-to-end anastomosis. Graft patency and anastomotic sites were monitored by computed tomography angiography (CTA) at 1 and 6 weeks post-surgery. After 2 months, the graft was explanted for systematic evaluation of vascular regeneration and repair through gross examination, histopathology (H&E and elastic fiber staining), immunohistochemistry [for ETS-related gene (ERG), Actin, and Vimentin], and scanning electron microscopy (SEM). Results Postoperative CTA confirmed excellent graft patency at both 1 and 6 weeks, with no evidence of thrombosis or anastomotic stenosis. Gross examination of the 2-month explant revealed a smooth luminal surface covered by neotissue. Histopathological analysis demonstrated that the graft successfully induced the formation of a three-layered structure resembling a native vessel wall, comprising endothelial cells, smooth muscle cells, and fibroblasts. Immunohistochemistry further verified coverage of the luminal surface by endothelial cells (ERG-positive), along with the presence of neosmooth muscle (Actin-positive) and fibroblasts (Vimentin-positive). Endothelial cells were observed adhering to the inner surface of the artificial vessel under SEM. Conclusion The biomimetic, three-layered PLLA/PCL large-diameter vascular graft, constructed via electrospinning and ultrasonic pore-forming, exhibits excellent short-term patency and biocompatibility in a large animal model. More importantly, it demonstrates a significant potential to promote host cell infiltration and achieve in situ regeneration of a three-layered vascular wall structure, providing a promising experimental basis for the development of next-generation functional vascular substitutes.
6.Review of application scope of mobile medical devices combined with EMA method for lung cancer patient caring
Zi-dan WANG ; Hong-yue WU ; Bing LI ; Xin-tong ZHENG ; Jun-ling LIU ; Ying-nan ZHAO ; Yan LI
Chinese Medical Equipment Journal 2025;46(10):71-77
Relevant literature on mobile medical devices combined with the ecological momentary assessment(EMA)method applied to lung cancer patient caring was collected from some databases of CNKI,Wanfang,VIP,China Biomedical Literature Database,PubMed,Embase,Cochrane Library,CINAHL and Web of Science.The method of scoping review was used to sort out the general characteristics of the included literature,types and application of mobile medical devices,assessment content elements and outcome indicators.The feasibility and validity of mobile medical devices combined with the EMA method for the symptom assessment of lung cancer patients were described,whose advantages in monitoring during lung cancer caring and application prospects were elaborated.The problems of mobile medical devices during practical application were pointed out and some countermeasures were put forward accordingly.References were provided for personalized remote caring of lung cancer patients and development of intelligent multi-modal mobile devices.[Chinese Medical Equipment Journal,2025,46(10):71-77]
7.Exploration on Fine Operation Management of Low Value Consumables under SPD Management Model
Hong-bin WANG ; Yi XU ; Qing ZHENG ; Xuezhi HONG ; Chunrong TAN ; Yongqin ZHANG ; Li WANG ; Jinxia ZHANG
Chinese Health Economics 2025;44(9):80-83
Objective:To strengthen the management of low-value consumables in public hospitals by introducing the Supply Processing Distribution(SPD)management model,and to explore refined operational management strategies and path optimization for low-value consumables.Methods:The SPD management model was introduced,and the entire process of hospital consumables was refinedly managed using third-party supply chain information management platforms,visualized tertiary department warehouses,Radio Frequency Identification(RFID)technology and intelligent cabinet systems,Unique Device Identification(UDI)coding,"four-code integration"and other supporting technologies.Results:Based on the analysis of the current situation in the target Hospital,specific measures related to the management of low-value consumables were introduced after the introduction of the SPD model.Conclusion:It provides a reference and guidance for the hospital's medical consumables management department to promote refined management of medical consumables under the SPD model.
8.Changing antimicrobial resistance profiles of Burkholderia cepacia in hospitals across China:results from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Chunyue GE ; Yunjian HU ; Xiaoman AI ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Hui LI ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(5):557-562
Objective To examine the changing prevalence and antimicrobial resistance profiles of Burkholderia cepacia in 52 hospitals across China from 2015 to 2021.Methods A total of 9 261 strains of B.cepacia were collected from 52 hospitals between January 1,2015 and December 31,2021.Antimicrobial susceptibility of the strains was tested using Kirby-Bauer method or automated antimicrobial susceptibility testing systems according to a unified protocol.The results were interpreted according to the breakpoints released in the Clinical & Laboratory Standards Institute(CLSI)guidelines(2023 edition).Results A total of 9 261 strains of B.cepacia were isolated from all age groups,especially elderly patients.The proportion was 11.1%(1 032 strains)in children,significantly lower than the proportion in adults.About half(46.5%,4 310/9 261)of the strains were isolated from patients at least 60 years old and 42.3%(3 919/9 261)of the strains were isolated from young adults.Most isolates(71.1%)were isolated from sputum and respiratory secretions,followed by urine(10.7%)and blood samples(8.1%).B.cepacia isolates were highly susceptible to the five antimicrobial agents recommended in the CLSI M100 document(33rd edition,2023).B.cepacia isolates showed relatively higher resistance rates to meropenem and levofloxacin.However,the resistance rates to ceftazidime,trimethoprim-sulfamethoxazole,and minocycline remained below 8.1%.The percentage of B.cepacia strains resistant to levofloxacin was the highest compared to other antibiotics in any of the three age groups(from 12.4%in the patients<18 years old to 20.6%in the patients aged 60 years or older).Conclusions B.cepacia is one of the clinically important non-fermenting gram-negative bacteria.Accurate and timely reporting of antimicrobial susceptibility test results and ongoing antimicrobial resistance surveillance are helpful for rational prescription of antimicrobial agents and proper prevention and control of nosocomial infections.
9.Effects of high-altitude hypoxia exposure on brain injury in rats based on oxidative stress and aquaporins
Xin-jue ZHANG ; Wang-jie CAO ; Yun SU ; Hong-xia GONG ; Yong HUANG ; Yong-qi LIU ; Jian-zheng HE ; Jia-wang GUO ; Neng-xian ZHANG
The Chinese Journal of Clinical Pharmacology 2025;41(1):81-85
Objective To explore the brain damage of SD rats under different time points of hypobaric hypoxia exposure.Methods A rat high-altitube cerebral edema(HACE)model was constructed by simulating an altitude of 6 000 m in a hypobaric hypoxia animal experimental chamber.Thirty-six SD male rats were randomly divided into the control group and the hypobaric hypoxia exposure 3,7 and 14 d groups,with 9 rats in each group.Except for the control group,the rats in each group were continuously exposed to hypobaric hypoxia for 3,7,and 14 d.At the end of the modeling period,serum was collected by blood sampling via the abdominal aorta,and brain tissue samples were taken.The wet-to-dry ratio(W/D)of brain tissue was calculated,and the levels of relevant oxidative enzymes in serum and brain tissue were measured.The expression levels of hypoxia-inducible factor-1α(HIF-1α)and aquaporin 4(AQP4)mRNAs in brain tissue were detected by real-time fluorescence quantitative polymerase chain reaction.Results The W/D of brain tissues in the control group and the group exposed to hypobaric hypoxia for 3,7 and 14 d were 4.46±0.12,4.98±0.16,5.07±0.18 and 4.95±0.07;the superoxide dismutase contents were(111.86±2.45),(90.73±1.48),(79.64±2.56)and(55.33±1.45)U·g-1;the glutathione contents were(126.91±5.18),(125.26±1.53),(56.20±2.17)and(122.73±1.78)μg·mL-1;the malondialdehyde contents were(230.94±2.00),(362.65±3.28),(407.34±3.47)and(237.50±1.59)nmol·g-1;the relative expression levels of HIF-1 α mRNA were 1.00±0,2.99±0.49,4.72±0.49 and 1.91±0.28;the relative expression levels of AQP4 mRNA were 1.00±0,2.62±0.34,8.38±0.84 and 5.27±0.42,respectively.Statistically significant differences were found between the above indexes in the 3,7 and 14 d of hypobaric hypoxia exposure group compared with the control group(P<0.05,P<0.01).Conclusion Different time of hypobaric hypoxia exposure can up-regulate the expression of AQPs proteins in HACE rats and cause the disruption of the blood-brain barrier,and the HACE model constructed in the hypobaric hypoxia chamber with 6 000 m intervention for 7 d was more stable.
10.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.

Result Analysis
Print
Save
E-mail