1.Alterations of diffusion kurtosis measures in gait-related white matter in the "ON-OFF state" of Parkinson's disease.
Xuan WEI ; Shiya WANG ; Mingkai ZHANG ; Ying YAN ; Zheng WANG ; Wei WEI ; Houzhen TUO ; Zhenchang WANG
Chinese Medical Journal 2025;138(9):1094-1102
BACKGROUND:
Gait impairment is closely related to quality of life in patients with Parkinson's disease (PD). This study aimed to explore alterations in brain microstructure in PD patients and healthy controls (HCs) and to identify the correlation of gait impairment in the ON and OFF states of patients with PD, respectively.
METHODS:
We enrolled 24 PD patients and 29 HCs from the Movement Disorders Program at Beijing Friendship Hospital Capital Medical University between 2019 and 2020. We acquired magnetic resonance imaging (MRI) scans and processed the diffusion kurtosis imaging (DKI) images. Preprocessing of diffusion-weighted data was performed with Mrtrix3 software, using a directional distribution function to track participants' main white matter fiber bundles. Demographic and clinical characteristics were recorded. Quantitative gait and clinical scales were used to assess the status of medication ON and OFF in PD patients.
RESULTS:
The axial kurtosis (AK), mean kurtosis (MK), and radial kurtosis (RK) of five specific white matter fiber tracts, the bilateral corticospinal tract, left superior longitudinal fasciculus, left anterior thalamic radiation, forceps minor, and forceps major were significantly higher in PD patients compared to HCs. Additionally, the MK values were negatively correlated with Timed Up and Go Test (TUG) scores in both the ON and OFF in PD patients. Within the PD group, higher AK, MK, and RK values, whether the patients were ON or OFF, were associated with better gait performance (i.e., higher velocity and stride length).
CONCLUSIONS
PD exhibits characteristic regional patterns of white matter microstructural degradation. Correlations between objective gait parameters and DKI values suggest that dopamine-responsive gait function depends on preserved white matter microstructure. DKI-based Tract-Based Spatial Statistics (TBSS) analysis may serve as a tool for evaluating PD-related motor impairments (e.g., gait impairment) and could yield potential neuroimaging biomarkers.
Humans
;
Parkinson Disease/diagnostic imaging*
;
White Matter/physiopathology*
;
Male
;
Female
;
Middle Aged
;
Aged
;
Gait/physiology*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Diffusion Tensor Imaging/methods*
3.Preliminary study on the relationship between the degree of transverse sinus stenosis and cerebral blood flow in normal adults based on four-dimensional flow MRI
Xu HAN ; Heyu DING ; Chihang DAI ; Xiaoyu QIU ; Yan HUANG ; Ruowei TANG ; Shusheng GONG ; Long JIN ; Zhenghan YANG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Journal of Radiology 2025;59(3):269-276
Objective:To evaluate the relationship between transverse sinus stenosis (TSS) and cerebral blood flow in normal adults based on four-dimensional flow (4D Flow) MRI.Methods:The study was a cross-sectional study. Totally 81 normal volunteers who underwent magnetic resonance venography (MRV) and 4D Flow MRI were prospectively enrolled at Beijing Friendship Hospital, Capital Medical University from January 2020 to December 2022. Based on MRV evaluation of transverse sinus dysplasia, the volunteers were divided into a dysplasia group (26 cases) and a non-dysplasia group (55 cases); The area of the stenosis and the normal transverse sinus at the distal end were measured. The degree of TSS and the bilateral average transverse sinus stenosis (BA-TSS) were calculated. TSS was determined using TSS levels of 1/3, 1/2, and 2/3 as thresholds, and was divided into three groups: no TSS group, unilateral TSS group, and bilateral TSS group, with 28, 39, and 14 cases, 37, 37, and 7 cases, and 43, 36, and 2 cases, respectively. Based on 4D Flow MRI, the blood flow of the internal carotid artery, vertebral artery, superior sagittal sinus, straight sinus, and transverse sinus distal and proximal ends were measured. The cerebral blood flow (bilateral internal carotid artery blood flow+bilateral vertebral artery blood flow), venous sinus return blood flow 1 (superior sagittal sinus blood flow+straight sinus blood flow), return blood flow 2 (sum of bilateral transverse sinus distal end blood flow), return blood flow 3 (sum of bilateral transverse sinus proximal end blood flow), and the ratio of return blood flow to cerebral blood flow were calculated. Independent sample t-test was used to compare the differences between the group with and without transverse sinus dysplasia; Single factor analysis of variance was used to compare the differences between the TSS free group, unilateral TSS group, and bilateral TSS group. Based on single factor linear regression, the relationships between BA-TSS and blood flow parameters were analyzed.Results:There was no statistically significant difference in various blood flow parameters between the group with and without transverse sinus dysplasia (all P>0.05). When using 1/3, 1/2, and 2/3 as thresholds, there was no statistically significant difference in various blood flow parameters between the non TSS group, unilateral TSS group, and bilateral TSS group (all P>0.05). BA-TSS was linearly positively correlated with cerebral blood flow (β=0.986, 95% CI 0.108-1.865, P=0.028), but not linearly correlated with return blood flow 1, 2, and 3 (all P>0.05). The degree of BA-TSS was linearly negatively correlated with return blood flow 1/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.009) and return blood flow 2/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.018), but not with return blood flow 3/cerebral blood flow ( P=0.076). Conclusion:The BA-TSS degree in normal adults is positively correlated with cerebral blood inflow and negatively correlated with the proportion of venous sinus outflow.
4.Strengthening the Construction of Clinical Quality Control System for MRI Equipment to Ensure Their Efficacy in Clinical Application
Hongxia YIN ; Chengwei LI ; Yawen LIU ; Hui XU ; Yu ZHANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):583-586
With the rapid increase in the ownership of MRI equipment in China,quality control,particularly in clinical usage aspects,has become critically important.For clinical quality control of MRI systems,it is essential to establish comprehensive workflow principles encompassing multiple elements such as personnel,equipment,standards,tools and methodologies.To advance the standardization and widespread adoption of clinical quality control for MRI equipment,efforts must focus on strengthening regulatory frameworks,advancing phantom research,development and enhancing professional expertise.Concurrently,continuous improvements in training programs and supervision mechanisms are necessary to ensure the effective implementation of MRI clinical quality control practices.Furthermore,in the era of digital healthcare,clinical quality assurance for MRI equipment is evolving toward automation and intelligent solutions,providing higher-quality and more efficient assurance for clinical applications.
5.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.
6.Automatic Detection of Quality Control Performance of Radio Frequency Coils Based on ACR Phantom
Yawen LIU ; Hongxia YIN ; Yu ZHANG ; Pengling REN ; Yanjun HU ; Hui XU ; Zhenghan YANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):601-606
Purpose To explore an automatic detection method for quality control performance indicators of radio frequency coils based on American College of Radiology(ACR)phantom,and verify its accuracy stability and computational efficiency.Materials and Methods A retrospective study was conducted on 50 quality control images collected based on ACR phantom in Beijing Friendship Hospital,Capital Medical University from May 2017 to July 2019.The measurement and calculation methods of signal noise ratio(SNR),percent image uniformity(PIU)and percent signal ghosting(PSG)were used to automatically calculate the above indicators using a self-designed program in Python.A simple linear regression analysis on the automatically calculated SNR,PSG and PIU values compared to the manually measured results was performed,and Bland-Altman analysis was used to calculate the percentage difference to evaluate the consistency and bias between the performance indicators calculated by the two methods.The time consumption of two detection methods was compared to verify their computational complexity and efficiency.Results There was a strong correlation between the performance indicators SNR,PSG and PIU of radio frequency coils measured and calculated automatically and manually(r=0.991 4,0.992 8 and 0.909 8,all P<0.0001).The Bland-Altman results showed that most of the data fall within the 95%confidence interval and were evenly distributed.In terms of computational complexity and efficiency,compared to the complex manual delineation and calculation of 2-3 minutes per case,automatic detection could simultaneously obtain SNR,PSG and PIU values in less than 1 second.Conclusion The automatic and manual measurement methods have good consistency,and the automatic detection method is easy to operate,which is helpful for the daily quality control work and performance monitoring of radio frequency coils.
7.A comparative study of ultra-high-resolution CT and multi-slice spiral CT showing the key sound transmission structures of the middle ear
Yufei SUN ; Ruowei TANG ; Heyu DING ; Ning XU ; Zhaohui ZHONG ; Zhenghan YANG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Archives of Otolaryngology-Head and Neck Surgery 2025;32(4):225-228,233
OBJECTIVE To compare the ability of ultra-high-resolution CT(U-HRCT)and multi-slice spiral CT(MSCT)to display key vocal transmission structures in the middle ear.METHODS Subjects with normal middle ear structures who underwent 0.1 mm layer thickness U-HRCT and 0.625 mm layer thickness MSCT scans at the same time in Beijing Friendship Hospital affiliated to Capital Medical University from December 2019 to August 2024 were retrospectively enrolled.Two experienced head and neck radiologists reconstruct standard transsectional,coronal images based on the thinnest layer thickness.According to the 5-point method,16 key sound transmission structures of the middle ear,including malleus,incus and stapes,as well as joints,ligaments and tendons,were evaluated for image quality scoring.The standard deviation(SD)value,signal noise ratio(SNR),and contrast noise ratio(CNR)of bone in the malleus region and intratympanic gas were measured and calculated on the two examination images.RESULTS Thirty patients(47 sides)with normal middle ear structure were included,including 18 males and 12 females.The two physicians compared the results of U-HRCT in showing malleus head,malleus neck,malleus handle,incus body,long process,and short process,5 points accounted for 100%,and the 5-point scores of incudomalleolar joint space,incudostapedial joint space,stapes footplate and annular ligament were 100%,98.29%,75.83%and 77.83%,respectively,which were significantly higher than those of MSCT(P<0.001).In addition,U-HRCT showed higher scores for lenticular process,stapes head,anterior arch of stapes,posterior arch of stapes,annular ligament,stapes muscle,and tendo musculi tensoris tympani than MSCT(P<0.001),and the lenticular process showed a 100%display rate.There was no significant difference in the SNR between the two groups(P>0.05),but the SD value of the malleus in U-HRCT was 161.6±36.4,which was significantly lower than that in MSCT(297.8±128.1),and the difference was statistically significant(P<0.001).CONCLUSION U-HRCT can clearly visualize the key sound transmission structures of the middle ear,and its visualization ability is significantly better than that of MSCT.
8.Clinical efficacy of minimally invasive coronary artery bypass grafting via left intercostal small incision for multivessel coronary artery disease: A retrospective cohort study
Zeyuan ZHAO ; Zhihua WANG ; Sheng WANG ; Xianjie CHEN ; Zhao LI ; Guoqing LU ; Zhenchang QI ; Zhaoyun CHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(10):1455-1461
Objective To investigate the early clinical efficacy of minimally invasive cardiac surgery coronary artery bypass grafting (MICS CABG) via left intercostal small incision for multivessel coronary artery disease. Methods The patients who received off-pump CABG in the Central China Fuwai Hospital of Zhengzhou University from June 2021 to June 2023 were enrolled. Patients were divided into two groups according to the operative technique used, including a traditional midline sternotomy group and a left intercostal small incision group. The clinical data of the two groups were compared. Results A total of 143 patients were enrolled, including 70 patients in the traditional midline sternotomy group and 73 patients in the left intercostal small incision group. The age of the patients in the left intercostal small incision group and the traditional midline sternotomy group was (63.8±8.0) years and (63.0±7.8) years, respectively; the proportions of males were 69.9% and 74.3%, respectively. The differences were not statistically significant (all P>0.05). All patients in the two groups successfully completed the operation, and no patients in the left intercostal small incision group were converted to thoracotomy. The patients in the left intercostal small incision group showed less postoperative drainage within postoperative 24 hours [(239.4±177.7) mL vs. (338.0±151.9) mL, P<0.001], lower perioperative blood transfusion rate [32.9% (24/73) vs. 51.4% (36/70), P=0.028], higher postoperative myoglobin level within postoperative 24 hours [366.1 (247.9, 513.0) ng/mL vs. 220.8 (147.2, 314.9) ng/mL, P<0.001], shorter intensive care unit stay [45.5 (31.5, 67.5) h vs. 68.0 (46.0, 78.5) h, P=0.001] and postoperative hospital stay [(10.8±4.0) d vs. (13.1±5.3) d, P=0.028] compared to the traditional midline sternotomy group. There was no significant difference in the incidence of major adverse cardiac and cerebrovascular event between the two groups [2.7% (2/73) vs. 2.9% (2/70), P=1.000]. Conclusion Compared to the full median sternotomy, MICS CABG leads to a good clinical result with smaller trauma, faster overall recovery, and less perioperative blood transfusion.
9.Clinical outcomes of right anterior mini-thoracotomy aortic valve surgery: A propensity score matching study
Zeyuan ZHAO ; Chenyi CUI ; Jiahui LI ; Xianjie CHEN ; Zhao LI ; Zhenchang QI ; Sheng WANG ; Zhaoyun CHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1747-1753
Objective To compare perioperative outcomes of minimally invasive aortic valve surgery by a right anterior minithoracotomy (RAMT) and conventional sternotomy. Methods A retrospective analysis of patients who underwent isolated aortic valve surgeries in Central China Fuwai Hospital of Zhengzhou University between May 2021 and August 2023 with a minimal incision via the RAMT approach (a RAMT group) or conventional incision via the full sternotomy approach (a conventional group). A propensity score matching analysis was performed to balance preoperative data and compare perioperative data of the two groups. Results There were 58 patients in the RAMT group, including 46 males and 12 females with an average age of (52.0±14.1) years; 128 patients were enrolled in the conventional group, including 87 males and 41 females with an average age of (60.0±12.4) years. After propensity-score matching, there were 51 patients in each group. The RAMT group had a longer average operation time, cross-clamping time and cardiopulmonary bypass time compared to the conventional group (all P<0.05). However, ICU length of stay, ventilator-assisted time and postoperative hospital stay were significantly shorter in the RAMT group (all P<0.05). Patients in the RAMT group had lower 24 hour chest drain output (P<0.05). RAMT was associated with a trend towards a lower blood transfusion rate in comparison to the sternotomy group, although this was not statistically significant (P>0.05). The occurrence of all-cause death, and perioperative complications was also similar in both groups (P>0.05). Conclusion RAMT has less trauma, faster recovery, less postoperative drainage, and shorter hospital stay than conventional approach. RAMT in patients undergoing isolated aortic valve surgery is a safe approach.
10.Increased CT Attenuation of Pericolic Adipose Tissue as a Noninvasive Marker of Disease Severity in Ulcerative Colitis
Jun LU ; Hui XU ; Jing ZHENG ; Tianxin CHENG ; Xinjun HAN ; Yuxin WANG ; Xuxu MENG ; Xiaoyang LI ; Jiahui JIANG ; Xue DONG ; Xijie ZHANG ; Zhenchang WANG ; Zhenghan YANG ; Lixue XU
Korean Journal of Radiology 2025;26(5):411-421
Objective:
Accurate evaluation of inflammation severity in ulcerative colitis (UC) can guide treatment strategy selection. The potential value of the pericolic fat attenuation index (FAI) on CT as an indicator of disease severity remains unknown.This study aimed to assess the diagnostic accuracy of pericolic FAI in predicting UC severity.
Materials and Methods:
This retrospective study enrolled 148 patients (mean age 48 years; 87 males). The fat attenuation on CT was measured in four different locations: the mesocolic vascular side (MS) and opposite side of MS (OMS) around the most severe bowel lesion, the retroperitoneal space (RS), and the subcutaneous area. The fat attenuation indices (FAI MS, FAI OMS, and FAI RS) were calculated as the fat attenuation measured in MS, OMS, and RS, respectively, minus that of the subcutaneous area, and were obtained in the non-enhanced, arterial, and delayed phases. Correlations between the FAI and UC Endoscopic Index of Severity (UCEIS) were assessed using Spearman’s correlation. Predictors of severe UC (UCEIS ≥7) were selected by univariable analysis. The performance of FAI in predicting severe UC was evaluated using the area under the receiver operating characteristic curve (AUC).
Results:
The FAIMS and FAI OMS scores were significantly higher than FAI RS in three phases (all P < 0.001). The FAIMS and FAI OMS scores moderately correlated with the UCEIS score (r = 0.474–0.649 among the three phases). Additionally, FAI MS and FAI OMS identified severe UC, with AUC varying from 0.77 to 0.85.
Conclusion
Increased CT attenuation of pericolic adipose tissue could serve as a noninvasive marker for evaluating UC severity. FAI MS and FAI OMS of three phases showed similar prediction accuracies for severe UC identification.

Result Analysis
Print
Save
E-mail