1.Epidemiological and etiological characteristics of hand-foot-mouth disease in Hangzhou, Zhejiang Province, 2010‒2023
Shuang FENG ; Xiaobin REN ; Zhe WANG ; Zhaokai HE ; Yanyang TAO ; Qingjun KAO ; Zhou SUN
Shanghai Journal of Preventive Medicine 2025;37(2):129-134
ObjectiveTo analyze the epidemiological characteristics and trends of hand-foot-mouth disease (HFMD) in Hangzhou, so as to provide an evidence for developing effective prevention and control measures and evaluating the control effects. MethodsThe incidence data of HFMD in Hangzhou were collected from the Infectious Disease Reporting Information Management System of China Information System for Disease Control and Prevention. Descriptive epidemiology was applied to analyze the temporal, spatial and demographic distribution characteristics and etiology monitoring results of HFMD cases in Hangzhou from 2010 to 2023. Joinpoint regression model was used to analyze the trends of incidence rate of HFMD. Furthermore, circular distribution method was utilized to calculate the incidence peak of HFMD. ResultsFrom 2010 to 2023, the average annual reported incidence rate of HFMD in Hangzhou was 138.85/100 000, the proportion of severe cases was 0.04%, the mortality rate was 0.01/100 000, and the case fatality rate was 5.30/100 000. Both the total incidence rate and the incidence rate by sex showed an increasing trend. The annual reported incidence rate in males (158.72/100 000) was higher than that in females (117.61/100 000). The reported incidence rate showed a significant seasonal characteristic, with summer being the peak of epidemic. The results of surveillance samples suggested that the prevalence of HFMD in Hangzhou is characterized by the co-existence of multiple pathogens, with EV-A71 and CV-A16 being the dominant pathogens in the previous years and CV-A6 being the dominant pathogen since 2018. The proportion of EV-A71 in severe cases (77.19%) was higher than that in ordinary cases (15.37%), in addition, its proportion in ordinary cases, severe cases, and fatal cases all showed a decreasing trend. ConclusionThe incidence rate of HFMD in Hangzhou is still high, so it’s still necessary to continue to strengthen the prevention and control measures for key populations. In recent years, CV-A6 has been the main prevalent pathogen in Hangzhou. Further efforts in pathogen detection and analysis should be enhanced in the future.
2.Posterior medial branch block for persistent pain after percutaneous vertebral augmentation in osteoporotic vertebral fractures.
Zhe-Ren WANG ; Ren YU ; Chun-de LU ; Zhi-Yuan XU ; Bin WU ; Cheng NI
China Journal of Orthopaedics and Traumatology 2025;38(11):1145-1150
OBJECTIVE:
To evaluate the short-and medium-term efficacy of posterior medial branch block in the treatment of persistent pain after percutaneous vertebral augmentation.
METHODS:
From January 2018 to January 2023, a total of 1, 062 patients with osteoporotic vertebral compression fractures underwent percutaneous vertebral augmentation. Among them, 32 elderly patients who experienced persistent low back pain after surgery and subsequently received posterior medial branch block and cryoablation were included. Six patients died during follow-up, leaving 26 patients for final analysis (1 male, 25 females). The mean age was (82.96±5.66) years (ranged, 76 to 94 years). The mean body mass index was (23.76±3.08) kg·m-2(ranged 18.1 to 27.2 kg·m-2). The bone mineral density T-value ranged from -2.5 to -4.3 with a mean of (-3.09±0.56). The mean volume of bone cement injected was 6.00 (5.38, 7.00) ml. Fracture locations were T11 (2 cases), T12 (7 cases), L1 (10 cases), L2 (6 cases), and L3 (1 case). The mean interval from vertebral augmentation to block treatment was (7.12±2.22) months (rangd 6 to 12 months). The vertebral augmentation procedures were percutaneous kyphoplasty(PKP) in 12 cases and percutaneous vertebroplasty (PVP) in 14 cases. At the 2nd week, 3rd month, and 6th month after the block, the numerical rating scale(NRS), Oswestry disability index(ODI), patient satisfaction, and pain relief rate at the 6th month were evaluated. Relationships between pain relief rate at the 6th month after the last treatment and possible influencing factors were analyzed.
RESULTS:
Compared with X-ray films after percutaneous vertebral augmentation, the X-ray films before block showed an increase in kyphotic angle and vertebral compression rate, with statistically significant differences(P<0.05). At the 2nd week, 3rd month, and 6th month after posterior medial branch block and cryoablation, NRS and ODI scores were significantly lower than before the block(P<0.05). Among the 26 patients, 5 received additional cryoablation. At the 6th month after the last treatment, 19 patients reported excellent or good satisfaction. Univariate binary Logistic analysis showed all P>0.05, and no independent factor affecting final satisfaction or pain relief at 6 months after the last treatment was identified.
CONCLUSION
Posterior medial branch block(with cryoablation) can effectively improve short-and medium-term symptoms and function in patients with persistent axial low back pain after percutaneous vertebral augmentation for osteoporotic vertebral fractures.
Humans
;
Male
;
Female
;
Aged
;
Spinal Fractures/surgery*
;
Aged, 80 and over
;
Osteoporotic Fractures/surgery*
;
Vertebroplasty/adverse effects*
;
Nerve Block/methods*
3.Application of the modified Byars staged procedure for severe hypospadias repair.
Qi-Gen XIE ; Ting-Ting XUE ; Xu-Ren CHEN ; Zhao-Ying LI ; Zhe XU ; Zuo-Qing LI ; Peng LUO
Asian Journal of Andrology 2025;27(1):65-71
This study aimed to introduce a modified Byars staged procedure and investigate its application value in patients with severe hypospadias. We retrospectively analyzed the clinical data of patients with severe hypospadias admitted to the First Affiliated Hospital of Sun Yat-sen University (Guangzhou, China) between October 2012 and October 2022. In total, 31 patients underwent the conventional Byars procedure (conventional group), and 45 patients underwent the modified Byars staged procedure (modified group). Our modified strategy was built upon the standard Byars procedure by incorporating glansplasty during the first stage and employing a Y-shaped flap in conjunction with a glandular tunnel for urethroplasty during the second stage. Notably, there were no statistically significant differences in the preoperative baseline characteristics, duration of surgery, amount of blood loss, or occurrence of postoperative complications, including urethral fistula, stricture and diverticulum, or penile curvature, between the conventional and modified groups. However, there was a significantly lower incidence of coronal sulcus fistula (0 vs 16.1%, P = 0.02) and glans dehiscence (0 vs 12.9%, P = 0.02) in the surgical group than that in the conventional group. In addition, the modified group exhibited a notably greater rate of normotopic urethral opening (100.0% vs 83.9%, P = 0.01) and a higher mean score on the Hypospadias Objective Penile Evaluation (HOPE; mean ± standard error of mean: 8.6 ± 0.2 vs 7.9 ± 0.3, P = 0.02) than did the conventional group. In conclusion, the modified Byars staged procedure significantly reduced the risks of glans dehiscence and coronal sulcus fistula. Consequently, it offers a promising approach for achieving favorable penile esthetics, thereby providing a reliable therapeutic option for severe hypospadias.
Humans
;
Hypospadias/surgery*
;
Male
;
Retrospective Studies
;
Urologic Surgical Procedures, Male/methods*
;
Child, Preschool
;
Child
;
Postoperative Complications/etiology*
;
Urethra/surgery*
;
Plastic Surgery Procedures/methods*
;
Surgical Flaps
;
Penis/surgery*
;
Treatment Outcome
;
Infant
4.Acupuncture based on the "head qijie" theory combined with endovascular intervention for ischemic stroke: a randomized controlled trial.
Kun DAI ; Lili ZHANG ; Yu XIA ; Fuqiang SUN ; Zhe REN ; Gengchen LU ; Ruimin MA ; Bin CHENG
Chinese Acupuncture & Moxibustion 2025;45(6):723-727
OBJECTIVE:
To observe the clinical efficacy of acupuncture based on the "head qijie" theory combined with endovascular intervention in the treatment of ischemic stroke (IS).
METHODS:
Sixty-six IS patients were randomly divided into an experimental group (33 cases, 3 cases dropped out) and a control group (33 cases, 3 cases dropped out). The control group received endovascular intervention. On the basis of the treatment in the control group, the experimental group received acupuncture based on the "head qijie" theory starting from the second day after surgery, Baihui (GV20) and bilateral Fengchi (GB20), Tianzhu (BL10), etc. were selected, once a day, 6 times a week for 2 weeks. Before and after treatment, the scores of National Institutes of Health stroke scale (NIHSS), modified Barthel index (MBI) and modified Rankin scale (mRS) were observed in the two groups, the clinical efficacy and safety were evaluated.
RESULTS:
After treatment, the NIHSS and mRS scores were decreased compared with those before treatment in both groups (P<0.01), the NIHSS and mRS scores in the experimental group were lower than those in the control group (P<0.05). After treatment, the MBI scores were increased compared with those before treatment in both groups (P<0.01), the MBI score in the experimental group was higher than that in the control group (P<0.05). The total effective rate in the experimental group was 86.7% (26/30), which was higher than 66.7% (20/30) in the control group (P<0.05). The incidence of adverse events in the experimental group was 6.7% (2/30), which was lower than 13.3% (4/30) in the control group (P<0.05).
CONCLUSION
Acupuncture based on the "head qijie" theory combined with endovascular intervention in treating IS has good efficacy, improves neurological function, and enhances daily living ability.
Humans
;
Male
;
Female
;
Acupuncture Therapy
;
Middle Aged
;
Aged
;
Ischemic Stroke/therapy*
;
Acupuncture Points
;
Endovascular Procedures
;
Treatment Outcome
;
Adult
;
Combined Modality Therapy
5.Progress on Wastewater-based Epidemiology in China: Implementation Challenges and Opportunities in Public Health.
Qiu da ZHENG ; Xia Lu LIN ; Ying Sheng HE ; Zhe WANG ; Peng DU ; Xi Qing LI ; Yuan REN ; De Gao WANG ; Lu Hong WEN ; Ze Yang ZHAO ; Jianfa GAO ; Phong K THAI
Biomedical and Environmental Sciences 2025;38(11):1354-1358
Wastewater-based epidemiology has emerged as a transformative surveillance tool for estimating substance consumption and monitoring disease prevalence, particularly during the COVID-19 pandemic. It enables the population-level monitoring of illicit drug use, pathogen prevalence, and environmental pollutant exposure. In this perspective, we summarize the key challenges specific to the Chinese context: (1) Sampling inconsistencies, necessitating standardized 24-hour composite protocols with high-frequency autosamplers (≤ 15 min/event) to improve the representativeness of samples; (2) Biomarker validation, requiring rigorous assessment of excretion profiles and in-sewer stability; (3) Analytical method disparities, demanding inter-laboratory proficiency testing and the development of automated pretreatment instruments; (4) Catchment population dynamics, reducing estimation uncertainties through mobile phone data, flow-based models, or hydrochemical parameters; and (5) Ethical and data management concerns, including privacy risks for small communities, mitigated through data de-identification and tiered reporting platforms. To address these challenges, we propose an integrated framework that features adaptive sampling networks, multi-scale wastewater sample banks, biomarker databases with multidimensional metadata, and intelligent data dashboards. In summary, wastewater-based epidemiology offers unparalleled scalability for equitable health surveillance and can improve the health of the entire population by providing timely and objective information to guide the development of targeted policies.
China/epidemiology*
;
Humans
;
Wastewater/analysis*
;
COVID-19/epidemiology*
;
Public Health
;
Wastewater-Based Epidemiological Monitoring
;
SARS-CoV-2
6.Research progress in the diagnosis and control of animal Lyme disease
Jing-Zhe YU ; Jian-Qiao QIU ; Lan ZHOU ; Ren-Dong FANG ; Xue-Lei CHEN
Chinese Journal of Zoonoses 2024;40(1):62-69
Lyme disease is a natural zoonotic infectious disease transmitted by ticks infected by different genotypes of Borre-lia burgdorferi sensu lato,which was discovered in the 1970s.This pathogen is prevalent primarily in temperate and subtropi-cal areas.Dogs,cats,horses,cattle,deer,and other animals are susceptible,and humans are also susceptible hosts.The main symptoms of Lyme disease in humans are erythema migrans,arthritis,and other neurological symptoms,and the common symptoms in infected animals include joint diseases,coat shedding,fever,laminitis,and lameness.Lyme disease is wide-spread,but diagnosis is difficult,and this disease is easily misdiagnosed and missed.Awareness of Lyme disease must be in-creased to avoid its toll on livestock and the pet industry.Therefore,this article reviews research progress in diagnosis and con-trol technology for animal Lyme disease and Borrelia burgdorferi,to provide a reference for accurate,rapid diagnosis and con-trol of Lyme disease.
7.Analysis of surgical key points and postoperative rehabilitation management of total pancreaticoduodenectomy for pancreatic cancer
Zhe LIU ; Yanan JIA ; Yunzhao LUO ; Shaocheng LYU ; Wenli XU ; Jiqiao ZHU ; Ren LANG ; Qiang HE ; Xianliang LI
Chinese Journal of Hepatobiliary Surgery 2024;30(3):188-192
Objective:To explore the safety key points of total pancreaticoduodenectomy in the era of vascular resection technology and the important factors affecting rapid postoperative recovery.Methods:The clinical data of 52 patients with pancreatic cancer who underwent total pancreaticoduodenectomy in Beijing Chaoyang Hospital Affiliated to Capital Medical University from November 2014 to September 2022 were retrospectively analyzed, including 34 males and 18 females, aged (62±9). The intraoperative situation, incidence of postoperative complication, postoperative blood glucose control and postoperative survival rate were analyzed.Results:All operations of the 52 patients were successfully completed, including 48 patients underwent total pancreaticoduodenectomy combined with portal vein resection and allograft vascular grafts via artery approach. The portal vein occlusion time was (20±5) min. The incidence of postoperative complications was 28.8% (15/52), including 2 cases of abnormal gastric empty, 2 cases of diarrhea, 2 cases of chylous fistula, 4 cases of abdominal infection, 1 case of gastrointestinal fistula, 3 cases of gastrointestinal bleeding, and 1 case of pulmonary infection. Subcutaneous short-acting insulin injection was used to control blood glucose in the early stage after surgery, short-acting insulin combined with long-acting insulin was used for subcutaneous injection before sleep for diet recovery. All patients did not experience uncontrolled hyperglycemia. The median survival time of 52 patients was 13 months, and the longest follow-up time was 38 months. There were 37 patients died of tumor recurrence, 4 patients died of cardiovascular and cerebrovascular accidents, and 1 patient died of pulmonary infection in the 42 died patients.Conclusions:Total pancreaticoduodenectomy via artery approach can improve the R 0 resection rate in pancreatic cancer patients with vascular invasion, the rate of postoperative complication and mortality has no significant increase. The postoperative blood sugar control is satisfactory and the quality of life is guaranteed.
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail