1.A case-control study of shoulder arthroscopic double row and single row technique for the treatment of Ideberg type ⅠA scapular glenoid fracture.
Zhe-Yuan SHEN ; Rong WU ; Qiao-Ying PENG ; Heng LI ; Song-Hua GUO ; Zhan-Feng ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(3):223-230
OBJECTIVE:
To compare clinical effect of arthroscopic double row fixation and single row fixation in treating Ideberg typeⅠA scapular glenoid fracture.
METHODS:
From June 2018 to December 2022, 26 patients with Ideberg typeⅠA scapular glenoid fracture treated with shoulder arthroscopy were divided into single-row anchor group and double-row anchor group according to the fixation method of fracture block. There were 12 patients in single-row anchor group, including 7 males and 5 females, aged from 25 to 53 years old with an average of (38.42±9.61) years old;the time from injury to operation ranged from 2 to 7 days with an average of (4.75±1.82) days. There were 14 patients in double-row anchor group, including 10 males and 4 females, aged from 21to 53 years old with an average of (37.36±10.19) years old;the time from injury to operation ranged from 1 to 8 days with an average of (4.21±2.01) days. The changes of shoulder joint flexion, abduction, lateral lateral rotation, Constant-Murley shoulder function score and Rowe scores were compared between two groups before operation and 1 year after operation. The percentage of bone mass in pelvis area before operation and the percentage of bone defect in pelvis area at the latest follow-up were compared between two groups.
RESULTS:
All patients were followed up for 12 to 15 months with an average of (13.08±1.17) months in single-row anchor group and 12 to 15 months with an average of (13.29±1.07) months in double-row anchor group, with no statistical significance between two groups (P>0.05). The results of anterior flexion, abduction and lateral lateral rotation in single-row anchor group were(86.67±6.62) °, (79.50±5.68) °, (38.17±1.70) ° before operation, and (162.50±4.52)°, (169.17±3.35)°, (50.67±10.20)° at 1 year after operation; while in double-row anchor group were (84.14±5.48) °, (81.71±5.20) °, (39.29±3.63) ° before operation and (162.29 ± 5.53) °, (167.14±3.61) °, (56.93±9.56) ° at 1 year after operation;the difference between two groups before operation and 1 year after operation was statistically significant (P<0.05). There were no significant difference between two groups (P>0.05). Constant-Murley scores and Rowe scores in single-row anchor group were (55.42±3.75), (43.75±18.49) before operation and (94.83±2.21), (95.42±4.50) at 1 year after operation, respectively;while in double-row anchor group were (54.50±7.88), (41.79±18.25) before operation and (94.36±4.73), (95.00±4.80) at 1 year after operation;there was no significant difference in Constant-Murley score and Rowe score between two groups before operation and 1 year after operation (P>0.05). There was significant difference in the percentage of bone mass in pelvis area between two groups before operation (P>0.05). There was no significant difference in the percentage of bone defect in the shoulder area between single-row anchor group(4.42±1.51)% and double-row anchor group (2.71±1.44)% at 1 year after operation (P<0.05).
CONCLUSION
Both single and double row fixation techniques for the treatment of Ideberg typeⅠA scapular glenoid fracture could receive satisfactory functional recovery. However, double-row fixation has more advantages in reducing bone resorption of fracture mass.
Humans
;
Female
;
Male
;
Middle Aged
;
Arthroscopy/methods*
;
Adult
;
Scapula/surgery*
;
Case-Control Studies
;
Fractures, Bone/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Shoulder Joint/physiopathology*
;
Range of Motion, Articular
2.Altered serum metabolic profile in patients with autoimmune gastritis compared to other chronic gastritis.
Jihua SHI ; Yang ZHANG ; Yiran WANG ; Yuxi HUANG ; Zhe CHEN ; Xue XU ; Wenbin LI ; Dan CHEN ; Hao LUO ; Qingfeng LUO ; Ruiyue YANG ; Xue QIAO
Journal of Pharmaceutical Analysis 2025;15(5):101104-101104
Image 1.
3.Association between Per and Polyfluoroalkyl Substance and Abdominal Fat Distribution: A Trait Spectrum Exposure Pattern and Structure-Based Investigation.
Zhi LI ; Shi Lin SHAN ; Chen Yang SONG ; Cheng Zhe TAO ; Hong QIAN ; Qin YUAN ; Yan ZHANG ; Qiao Qiao XU ; Yu Feng QIN ; Yun FAN ; Chun Cheng LU
Biomedical and Environmental Sciences 2025;38(1):3-14
OBJECTIVE:
To investigate the associations between eight serum per- and polyfluoroalkyl substances (PFASs) and regional fat depots, we analyzed the data from the National Health and Nutrition Examination Survey (NHANES) 2011-2018 cycles.
METHODS:
Multiple linear regression models were developed to explore the associations between serum PFAS concentrations and six fat compositions along with a fat distribution score created by summing the concentrations of the six fat compositions. The associations between structurally grouped PFASs and fat distribution were assessed, and a prediction model was developed to estimate the ability of PFAS exposure to predict obesity risk.
RESULTS:
Among females aged 39-59 years, trunk fat mass was positively associated with perfluorooctane sulfonate (PFOS). Higher concentrations of PFOS, perfluorohexane sulfonate (PFHxS), perfluorodecanoate (PFDeA), perfluorononanoate (PFNA), and n-perfluorooctanoate (n-PFOA) were linked to greater visceral adipose tissue in this group. In men, exposure to total perfluoroalkane sulfonates (PFSAs) and long-chain PFSAs was associated with reductions in abdominal fat, while higher abdominal fat in women aged 39-59 years was associated with short-chain PFSAs. The prediction model demonstrated high accuracy, with an area under the curve (AUC) of 0.9925 for predicting obesity risk.
CONCLUSION
PFAS exposure is associated with regional fat distribution, with varying effects based on age, sex, and PFAS structure. The findings highlight the potential role of PFAS exposure in influencing fat depots and obesity risk, with significant implications for public health. The prediction model provides a highly accurate tool for assessing obesity risk related to PFAS exposure.
Humans
;
Fluorocarbons/blood*
;
Female
;
Adult
;
Middle Aged
;
Male
;
Environmental Pollutants/blood*
;
Abdominal Fat
;
Nutrition Surveys
;
Alkanesulfonic Acids/blood*
;
Obesity
;
Environmental Exposure
4.Caries experience and its correlation with caries activity of 4-year-old children in Miyun District of Beijing
Xinxin CHEN ; Zhe TANG ; Yanchun QIAO ; Wensheng RONG
Journal of Peking University(Health Sciences) 2024;56(5):833-838
Objective:To investigate the prevalence of dental caries of 4-year-old children in Miyun District of Beijing by international caries detection and assessment system(ICDAS),to detect the caries activity Cariostat value and to analyze the correlation between the Cariostat value and dental caries.Methods:Totally 815 children aged 4 years in 7 kindergartens in Miyun District of Beijing were recrui-ted.The clinical examination of all children was conducted by one examiner using ICDAS.The oral de-birs and plaques were collected by one doctor who recorded the Cariostat scores.The results of clinical examination were compared between genders.At the same time,the prevalence of dental caries,the mean d3-6ft/d3_6fs and d1-6ft/d1-6fs among high Cariostat scores group(2.0-3.0),medium Cariostat scores group(1.5)and low Cariostat scores group(0-1.0)were compared.The distributions of incipi-ent caries in different Cariostat scores groups were compared among children with incipient caries only.Results:All the children had incipient caries,and 78.3%of the children had cavitated caries with ICDAS score of 3 or above.The mean d1-2t scores were 9.76±3.65,the mean d3-6ft scores was 4.64±4.43 and the mean d1-6ft scores were 14.41±3.42.The incipient caries with ICDAS score of 1-2 were widely distributed,accounting for 67.7%of the total numbers of caries.There was no significant diffe-rence in caries prevalence and caries experience between genders(P>0.05).The proportion of children with high Cariostat scores in boys(43.6%)was higher than that in girls(33%)and the difference was statistically significant(P<0.05).With the increase of Cariostat scores,the prevalence of cavitated caries,the mean d3-6ft/d3-6fs and d1-6ft/d,_6fs scores in children was on the increase and the difference among the three groups was statistically significant(P<0.05).For children with incipient caries only,the distribution of incipient caries in different Cariostat scores groups was no significant difference(P>0.05).Conclusion:ICDAS can detect early enamel demineralization of deciduous teeth in children.The prevalence of dental caries among 815 4-year-old children in Miyun District of Beijing is more serious,and incipient caries is widely distributed in children.Cariostat value reflects the status of cavi-tated caries and has no correlation with the distribution of incipient caries.Therefore,the combined ap-plication of ICDAS and Cariostat caries activity detection method is helpful for the detection of incipient caries and screening of caries high-risk children,which has great significance for the comprehensive ma-nagement of caries in children and the formulation of early preventive measures.
5.Analysis of the diagnostic efficiency of wrist joint ulnar deviation supination 45° palmar oblique position for scaphoid waist fracture and displacement
Shifei CHEN ; Jun ZHANG ; Shuman HAN ; Wenjuan WU ; Zhiwei ZHONG ; Jing LI ; Zhe GUO ; Huizhao WU ; Ziyi QIAO
Journal of Practical Radiology 2024;40(5):805-808
Objective To investigate the clinical application value of wrist joint ulnar deviation supination 45° palmar oblique posi-tion in the diagnosis of scaphoid waist fracture and displacement.Methods The imaging and clinical data such as digital radiography(DR),CT of 93 wrist joint trauma patients were analyzed.The four position views including wrist joint anteroposterior+lateral view,scaphoid position,wrist joint ulnar deviation supination 45° palmar oblique position,scaphoid position+wrist joint ulnar devia-tion supination 45° palmar oblique position were analyzed by three readers.The consistency of the evaluation among different readers and the diagnostic efficiency of the diagnosis of scaphoid fracture and displacement were compared.Results The inter-observer agreement,sensitivity,specificity,accuracy,and other diagnostic efficiency of scaphoid waist fracture and displacement was evaluated,wrist joint ulnar deviation supination 45° palmar oblique position+scaphoid position and wrist joint ulnar deviation supination 45° palmar oblique position were better than those of scaphoid position and wrist joint anteroposterior+lateral view.The combination of wrist joint ulnar deviation supination 45° palmar oblique position+scaphoid position obtained the best diagnostic efficiency.Conclusion The wrist joint ulnar deviation supination 45° palmar oblique position shows the long axis of the scaphoid,which has a high diagnostic efficiency in the diagnosis of scaphoid waist fracture and displacement and would be used as a useful supplement to other scaphoid imaging.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Research progress in the diagnosis and control of animal Lyme disease
Jing-Zhe YU ; Jian-Qiao QIU ; Lan ZHOU ; Ren-Dong FANG ; Xue-Lei CHEN
Chinese Journal of Zoonoses 2024;40(1):62-69
Lyme disease is a natural zoonotic infectious disease transmitted by ticks infected by different genotypes of Borre-lia burgdorferi sensu lato,which was discovered in the 1970s.This pathogen is prevalent primarily in temperate and subtropi-cal areas.Dogs,cats,horses,cattle,deer,and other animals are susceptible,and humans are also susceptible hosts.The main symptoms of Lyme disease in humans are erythema migrans,arthritis,and other neurological symptoms,and the common symptoms in infected animals include joint diseases,coat shedding,fever,laminitis,and lameness.Lyme disease is wide-spread,but diagnosis is difficult,and this disease is easily misdiagnosed and missed.Awareness of Lyme disease must be in-creased to avoid its toll on livestock and the pet industry.Therefore,this article reviews research progress in diagnosis and con-trol technology for animal Lyme disease and Borrelia burgdorferi,to provide a reference for accurate,rapid diagnosis and con-trol of Lyme disease.

Result Analysis
Print
Save
E-mail