1.Fetal development of chromogranin A-positive gastrointestinal endocrine cells revisited: a histological study using human fetuses
Ji Hyun KIM ; Zhe-Wu JIN ; Eri MIYAMOTO ; Sakiko TAKAHASHI ; Sayako SUZUKI ; Gen MURAKAMI ; Shin-ichi ABE
Anatomy & Cell Biology 2026;59(1):82-93
Initial gastrointestinal endocrine cells (GIECs) likely appear at the proximal and distal sites of abdominal intestines and may take a close topographical relation with neural elements in the gut. We examined immunohistochemically-stained sections from 10 fetuses at approximately 8–18 weeks of gestational age (36–155 mm of crown-rump length). Irrespective of whether physiological herniation was present (early 5 specimens) or absent (the other 5), the duodenum and jejunum had well-developed mucosa with villi containing abundant flask-like chromogranin-positive cells. In the earlier 5 specimens, the rectum, standing up to a level of the umbilicus, had a lumen and villi with a few positive cells, but the colon carried neither the lumen or chromogranin-positive cells. The initial GIECs seemed to appear in the basal payer of the epithelium at the distal and proximal foci depending on double pathways of neural crest cell migration. Less number of the colic chromograninpositive cells, more than 5-times difference in density relative to small intestine, was seen in the larger 5 specimens. The appearance of GIECs was delayed at the anal transitional zone (a border area between the columnar and squamous epithelia).The reactivity of neuronal nitric oxide synthase was restricted in the myenteric plexus, whereas clusters of slender calretininpositive cells existed in the lamina propria or core of villi in the duodenum and colon. Relatively small, round or oval positive cells were also seen in the basal layer of the columnar epithelium. Therefore, calretinin-positive cells might exist closely to GIECs in the developing villi.
2.Meconium containing intestinal structures: a histological study using human fetuses
Jun ZHANG ; Zhe-Wu JIN ; Feng HAN ; Ye XU ; Gen MURAKAMI ; Masahito YAMAMOTO ; Shogo HAYASHI
Anatomy & Cell Biology 2026;59(1):105-114
Meconium is changed from defoliated intestinal villi with apoptosis. A meconium corpuscle is a limited architecture in the meconium at the light microscopic level. In histological and immunohistochemical sections of the abdomen from 40 fetuses at 20–31 weeks of gestation, we found 12 fetuses with meconium and examined the architecture.A solid or loose meconium was seen depending on sites. The solid meconium in the colon and rectum contained numerous spherical or rugby ball-like corpuscles comprising of a core with tightly-packed atrophied cells and a laminar fibrous sheath.The solid meconium surrounded and incorporated villi that maintained the original architecture. The loose meconium was seen not only in the stomach and duodenum but also, depending on specimens, in the colon and rectum. It was composed of a large mucosal fold, a single small villus and/or fragmented epithelia. Notably, these mucosal tissues still contained chromogranin-positive gastrointestinal cells and cytokeratin-positive epithelia. A large ring-like meconium was composed of the entirely circular mucosa or epithelia that seemed to be detached along the muscularis mucosae or the basal lamina.A sheath-like fibrous structure in meconium seemed to originate from the lamina propria and basal lamina of villi. A defoliation of villi with apoptosis seemed difficult to explain a detachment of the entirely circular mucosa or epithelia in large fetuses examined. The latter event might require a specific mechanism such as an in utero intussusception in which a proximal side of the colon was invaginated into the distal lumen.
3.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
4.Exploration of ethical issues in the multiple disciplinary team model for children with 46, XY disorders of sex development
Lili PAN ; Zhe SU ; Wei SU ; Ying ZU ; Chenxi LI ; Huiping SU ; Jingyu YOU ; Kexin JIN ; Rongfei ZHENG
Chinese Medical Ethics 2026;39(6):718-723
ObjectiveTo explore the ethical issues and coping strategies in the diagnosis and treatment of 46, XY disorders of sex development (46, XY DSD) under a multidisciplinary team (MDT) model, and to deepen the understanding of relevant ethical issues while accumulating experience. MethodsA retrospective collection was conducted on the data of children with 46, XY disorders of sex development under a single-center MDT model from January 2017 to December 2024, and the ethical issues involved in the diagnosis and treatment process were analyzed. ResultsA total of 24 MDT discussion documents involving 20 children were collected, including 17 with female social gender and 3 with male social gender. The age ranged from 0.5 to 15.8 years, with children under 8 years accounting for 75%. The ethical issues primarily involved how to ensure adequate informed consent, whether surgery was necessary and its timing, and whether gender selection is reasonable and its timing. Among the 10 children raised as females who completed the gender role psychological scale assessment, 5 demonstrated masculine tendencies, all of whom had pathogenic genetic variants. Furthermore, only 1 patient changed the social gender to male. ConclusionThe diagnosis and treatment of 46, XY DSD is relatively complex, requiring multidisciplinary collaboration. This process involves numerous ethical issues and necessitates adhering to medical ethical principles. Ensuring adequate informed consent is crucial, especially for younger children. The surgery and its timing selection must adhere to the principles of beneficence, non-maleficence, and leaving room for the future. Gender selection constitutes a focus and challenge in diagnosis and treatment. Psychological scales and genetic etiologies are conducive to judgments regarding gender selection, yet multiple factors in the real world may interfere with the gender selection.
5.Analysis of Volatile Component Variations in Coptidis Rhizoma Processed with Euodiae Fructus Juice by HS-SPME-GC-MS Combined with Chemometrics and ROAV
Lin YAN ; Yun WANG ; Puling LI ; Lingbang MENG ; Zhe JIA ; Ying LI ; Ying LIU ; Min JIN ; Cun ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(21):218-225
ObjectiveTo analyze the volatile components in raw Coptidis Rhizoma, Euodiae Fructus juice-processed Coptidis Rhizoma (Yuhuanglian), and the processing adjuvant Euodiae Fructus juice, identify marker volatile components in the processed product, and elucidate the material basis changes during the processing with Euodiae Fructus juice. MethodsHeadspace solid-phase microextraction coupled with gas chromatography-quadrupole-time-of-flight mass spectrometry (HS-SPME-GC-Q-TOF-MS) was employed to analyze the volatile components in raw Coptidis Rhizoma, Yuhuanglian, and Euodiae Fructus juice. Chemometric analysis was performed to compare volatile components among samples and screen the marker components. Finally, the relative odor activity value (ROAV) was calculated to investigate odor characteristics. ResultsA total of 127 components were detected, with 27, 75, 84 volatile components identified in Euodiae Fructus juice, raw Coptidis Rhizoma, and Yuhuanglian, respectively. Processing with Euodiae Fructus juice significantly increased the number and content of volatile components. Chemometric analysis revealed significant changes in volatile components among the three sample types, allowing clear discrimination. After processing, 39 components such as methyl octanoate and allyl propionate were introduced, while 34 components including furfural and hexanoic acid increased in content, and 11 components including butyric acid and octanal decreased. Additionally, eight components, including zingiberene, 6-methyl-6-hepten-2-one, and 5-methyl-2-hexanone, were screened as marker components of Yuhuanglian. Moreover, processing enhanced the ROAV values of 2,5-dimethylpyrazine (roasted, nutty, coffee-like aroma), 3-ethylphenol, and guaiacol (smoky, woody aroma). Additionally, it incorporated 1-hepten-3-one from Euodiae Fructus juice and the newly generated 1-hexen-3-one, contributing mushroom and cucumber-like odors. The sensory profile of Yuhuanglian integrated nutty, roasted, smoky, and woody notes with the citrus and fruity aroma originally contributed by octanal. ConclusionThe processing with Euodiae Fructus juice introduced components from adjuvant, significantly altering the volatile component profile and enhancing the sensory odor characteristics of Yuhuanglian. This study provides a valuable reference for exploring the material basis of volatile components and establishing processing specifications for Yuhuanglian.
6.Analysis of Volatile Component Variations in Coptidis Rhizoma Processed with Euodiae Fructus Juice by HS-SPME-GC-MS Combined with Chemometrics and ROAV
Lin YAN ; Yun WANG ; Puling LI ; Lingbang MENG ; Zhe JIA ; Ying LI ; Ying LIU ; Min JIN ; Cun ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(21):218-225
ObjectiveTo analyze the volatile components in raw Coptidis Rhizoma, Euodiae Fructus juice-processed Coptidis Rhizoma (Yuhuanglian), and the processing adjuvant Euodiae Fructus juice, identify marker volatile components in the processed product, and elucidate the material basis changes during the processing with Euodiae Fructus juice. MethodsHeadspace solid-phase microextraction coupled with gas chromatography-quadrupole-time-of-flight mass spectrometry (HS-SPME-GC-Q-TOF-MS) was employed to analyze the volatile components in raw Coptidis Rhizoma, Yuhuanglian, and Euodiae Fructus juice. Chemometric analysis was performed to compare volatile components among samples and screen the marker components. Finally, the relative odor activity value (ROAV) was calculated to investigate odor characteristics. ResultsA total of 127 components were detected, with 27, 75, 84 volatile components identified in Euodiae Fructus juice, raw Coptidis Rhizoma, and Yuhuanglian, respectively. Processing with Euodiae Fructus juice significantly increased the number and content of volatile components. Chemometric analysis revealed significant changes in volatile components among the three sample types, allowing clear discrimination. After processing, 39 components such as methyl octanoate and allyl propionate were introduced, while 34 components including furfural and hexanoic acid increased in content, and 11 components including butyric acid and octanal decreased. Additionally, eight components, including zingiberene, 6-methyl-6-hepten-2-one, and 5-methyl-2-hexanone, were screened as marker components of Yuhuanglian. Moreover, processing enhanced the ROAV values of 2,5-dimethylpyrazine (roasted, nutty, coffee-like aroma), 3-ethylphenol, and guaiacol (smoky, woody aroma). Additionally, it incorporated 1-hepten-3-one from Euodiae Fructus juice and the newly generated 1-hexen-3-one, contributing mushroom and cucumber-like odors. The sensory profile of Yuhuanglian integrated nutty, roasted, smoky, and woody notes with the citrus and fruity aroma originally contributed by octanal. ConclusionThe processing with Euodiae Fructus juice introduced components from adjuvant, significantly altering the volatile component profile and enhancing the sensory odor characteristics of Yuhuanglian. This study provides a valuable reference for exploring the material basis of volatile components and establishing processing specifications for Yuhuanglian.
7.Research on Preservation Performance of Polymer Evidence Bags for Sealing Fire Debris
Yu-Hang JIANG ; Yao LIU ; Yu WANG ; Yan-Ru YAO ; Jing JIN ; Zheng-Zhe ZANG
Chinese Journal of Analytical Chemistry 2025;53(5):765-773,中插11-中插20
Arson is classified as a violent crime,and often involves accelerants that significantly increase casualties and property damage.These accelerants,typically flammable liquids with low saturated vapor pressure,present volatile characteristic components in fire residues,making evidence preservation critical for accurate forensic analysis.In this study,the preservation performance of AMPAC(American KAPAC polyester sampling bags)and polyethylene(PE)evidence bags were evaluated under simulated field conditions(40 oC)through gas chromatography-mass spectrometry(GC-MS)technique,focusing on background interference,sealing integrity,and cross-contamination.The results demonstrated that AMPAC bags exhibited minimal background interference(C12?C14 alkanes detected after 3?7 days)and effective gasoline sealing,though slight losses of C2?C3 alkylbenzenes and trace cross-contamination were observed.In contrast,PE bags showed significant background hydrocarbons(C15?C19 alkanes)and pronounced gasoline component losses,including C2?C4 alkylbenzenes,naphthalenes,and indenes.Notably,severe cross-contamination of gasoline markers was detected in adjacent blank PE bags,with characteristic components such as C2?C4 alkylbenzenes,naphthalenes,methylnaphthalenes,dimethylnaphthalenes,indenes,indanes,methylindenes,and dimethylindenes identified,indicating substantial cross-contamination issues in PE evidence bags.Microstructural analysis revealed superior sealing in AMPAC bags attributed to their smooth,dense surface morphology compared to PE's rougher,porous structure.This study established a comprehensive evaluation framework for fire residue evidence containers,and found that PE bags were unsuitable for long-term gasoline evidence preservation due to compromised integrity.These findings provided critical references for forensic container selection in fire investigations.
8.Preparation and Performance Test of Highly Stable Ammonium Ion Selective Electrode Based on Hydrophobic Solid Contact Layer
Chen-Yu LIU ; Jia-Wen YIN ; Yun-Zhe HAN ; Sheng-Kang LU ; Qing-Hui JIN
Chinese Journal of Analytical Chemistry 2025;53(5):774-784
The stability of ammonium ion selective electrode is an important indicator to ensure accurate monitoring of ammonia nitrogen concentration in drinking water.However,in long-term monitoring process,interfering ions and water molecules in water samples may penetrate into the interior of the ammonium ion selective electrode to form a water layer,which affects the potential response and stability of the electrode.Perfluorooctanoic acid is a low surface energy material,and doping it in polyaniline can reduce surface energy of the composite and improve surface roughness.In this work,five ammonium ion selective electrodes were prepared by doping polyaniline with different concentrations of perfluorooctanoic acid as a solid contact layer,which made the solid contact layer of electrode had hydrophobic properties,thereby improving stability of the ammonium ion selective electrode.The stability of the ion-selective electrode was evaluated by potential drift experiment,and the optimal doping concentration of perfluorooctanoic acid in the sediment solution was determined to be 5 mmol/L.The experiment results showed that the solid contact layer had a water contact angle of 132o under the doping concentration,the potential drift rate was 41.66 μV/h,and potential drift rate in the aqueous layer test was 1.31 mV/h,which were all better than those of the unmodified electrode.The standard deviation of the electrode potential was 1.42 mV,which was obviously superior to that of the unmodified electrode.The characteristics of high stability of the electrode made it suitable for long-term monitoring of ammonia nitrogen content in water samples.
9.Evaluation of stent effect display in lower extremity arterial occlusive disease based on energy spectrum CTA
Xin HUANG ; Ningning DING ; Li ZHOU ; Wenzhe ZHAO ; Daliang LI ; Zhe LIU ; Jian YANG ; Chao JIN
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(1):178-183
Objective To explore the clinical value of energy-spectrum CT single-energy imaging in enhancing the image quality and stent display of stent placement CT angiography(CTA)in lower extremity atherosclerotic occlusive disease.Methods Twenty patients[mean(65.61±9.65)years;male/female,16/4]who underwent stenting for chronic occlusive disease of the lower extremity arteries by lower extremity arterial energetic spectral CTA were retrospectively recruited at our hospital.The original images were reconstructed into seven sets of single energy(40-100 keV),120 kVp,virtual unenhanced images(VUE)and metal artifact reduction(MAR)technique images.Images were debossed and then scaffolded for display with volumetric reconstruction(VR),maximum density projection(MIP)and curve planar reconstruction(CPR),and were objectively and subjectively assessed and compared using one-way analysis of variance(ANOVA).Results The 80 keV and MAR images had the highest scores compared to the other reconstruction group images(P<0.01).Conclusion 80 keV single-energy imaging and de-metallization artifacts MAR improve the image quality of lower extremity arterial stent lumen and structure display;therefore,they have higher diagnostic value for clinicians.

Result Analysis
Print
Save
E-mail