1.Application of total life cycle management in managing maintenance cost of ultrasound imaging equipment
Zhanguo LI ; Yu WANG ; Huifang YANG ; Jing ZHAO
China Medical Equipment 2025;22(4):174-177
Objective:To explore the application effect of Total Life Cycle Management(TLCM)in managing maintenance cost of ultrasound imaging equipment.Methods:Thirty ultrasound imaging equipment of the China-Japan Friendship Hospital from June 2021 to July 2023 were selected.From June 2021 to June 2022,a conventional maintenance mode was adopted to manage these equipment,and TLCM was implemented to manage them from July 2022 to July 2023.The qualified rate and failure frequency of the ultrasound imaging equipment,the satisfaction scores of medical staffs in using equipment,and the costs of operation and maintenance were compared between different management modes.Results:Under TLCM mode,the qualified rate was 93.33%,which was significantly higher than 73.33% under conventional maintenance mode,and the difference was significant(x2=4.320,P<0.05). Under TLCM mode,the boot-up time of ultrasound imaging equipment was shorter than that under the conventional maintenance mode,and the difference was significant (t=7.146,P<0.05). Under TLCM mode,the failure rate of long-term use of equipment was lower than that under conventional maintenance,and the difference was significant (x2=4.443,P<0.05). The satisfaction scores of medical staffs for the performance,efficiency,and cleanliness of equipment under TLCM mode were higher than those under conventional maintenance mode,and the differences of them between two modes were significant (t=3.955,5.872,6.368,8.214,P<0.05). Under TLCM mode,both maintenance costs and operational expenses were lower than those under conventional maintenance,and the differences of them between two modes were significant (t=41.353,16.743,P<0.05). Conclusion:TLCM can effectively enhance operationally qualified rate of equipment,and reduce maintenance costs and failure rate of equipment in long-term use,and improves the satisfaction of medical staff.
2.Fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis
Yamin QIN ; Yipu LI ; Zhanguo SUN ; Yi FANG ; Xinwei HAN ; Dechao JIAO
Journal of Practical Radiology 2025;41(11):1866-1868
Objective To evaluate the feasibility of fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis.Methods Twenty-two patients who underwent Bricker surgery presented with hydronephrosis were selected.Using a catheter-wire technique,percutaneous nephrostomy tract was used to access the uretero-ileal neobladder stric-ture and establish a sheath biopsy channel.Forceps biopsy was performed at the uretero-ileal neobladder anastomotic site,followed by placement of a 10.2F ureteral stent.The technical success rate,complications,biopsy sensitivity,specificity,accuracy were recorded,and preoperative versus postoperative white blood cell counts,creatinine,and urea nitrogen levels were compared.Results The tech-nical success rate was 100%(22/22),with no serious complications,such as ureteral perforation and major bleeding.The accuracy,sensitivity and specificity of the biopsy were 95.45%(21/22),85.71%(6/7)and 100%(15/15),respectively.Preoperative and post-operative white blood cell counts were(9.17±2.16)× 1012/L vs(6.03±1.51)×1012/L,creatinine levels were(219.95±78.47)U/mL vs(78.91±17.23)U/mL,and urea nitrogen levels were(19.85±5.27)U/mL vs(5.95±1.60)U/mL.All three parameters showed statistically significant differences(P<0.05).Conclusion The fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis is safe and feasible.
3.Analysis of the efficacy of lamb′s tripe extract and vitamin B 12 capsule on chronic atrophic gastritis at different sites
Dongdong XIA ; Huahong XIE ; Bo JIANG ; Hong XU ; Zhanguo NIE ; Chengwei TANG ; Qiang GUO ; Xiaoping ZOU ; Shuisheng SHI ; Tao SUN ; Shourong SHEN ; Guoqing LI ; Xiaozhong GUO ; Xiaoyan ZHAO ; Jiaming QIAN ; Weixing CHEN ; Guiying ZHANG ; Aijun LIAO ; Jingyuan FANG ; Daiming FAN ; Kaichun WU
Chinese Journal of Digestion 2025;45(3):162-168
Objective:To evaluate the efficacy of lamb′s tripe extract and vitamin B 12 capsule (LTEVB 12C) on chronic atrophic gastritis (CAG) at different locations (antrum lesser curvature, antrum greater curvature, gastric angle, corpus lesser curvature, and corpus greater curvature). Methods:From August 2011 to January 2013, 715 patients with CAG in a multicenter, randomized, double-blind, placebo-controlled trial were enrolled from 16 tertiary first-class hospitals across the country, including the First Affiliated Hospital of Air Force Medical University, Nanfang Hospital of Southern Medical University, the First Hospital of Jilin University, West China Hospital of Sichuan University, etc., there were 476 cases in the LTEVB 12C group and 239 cases in the placebo group. The patients of the LTEVB 12C group received LTEVB 12C, and the patients of placebo group received LTEVB 12C mimetic, all the medications were taken 3 capsules each time and 3 times a day after meals, and the treatment course of 2 groups were both 6 months. The efficacy evaluation criteria included the effective rate (a decrease of ≥1 in histopathological score compared with baseline after 6 months of treatment) and the reversal rate (a decrease of ≥ 2 in histopathological score compared with baseline after 6 months of treatment in the patients with moderate to severe CAG). The impact of lesion sites on the therapeutic effects of LTEVB 12C was analyzed by logistic regression analysis. The two-way unordered Cochran-Mantel-Haenszel chi-square test considering the center effect and Pearson chi-square test were used for statistical analysis. Results:The effective rates of chronic inflammation at the antrum greater curvature and corpus greater curvature (23.3%, 110/473 vs. 13.0%, 31/239; 20.3%, 96/472 vs. 12.6%, 30/239), the effective rates of atrophy at the antrum lesser curvature, antrum greater curvature, gastric angle, corpus lesser curvature, and the corpus greater curvature (27.0%, 118/437 vs. 15.7%, 34/216; 29.2%, 126/432 vs. 18.5%, 38/205; 27.8%, 121/435 vs. 16.7%, 36/216; 32.5%, 127/391 vs. 19.8%, 37/187; 33.0%, 119/361 vs. 21.8%, 39/179), and the effective rates of intestinal metaplasia at the antrum lesser curvature, antrum greater curvature, gastric angle, and the corpus lesser curvature (45.0%, 112/249 vs. 29.8%, 31/104; 53.8%, 86/160 vs. 33.9%, 21/62; 45.8%, 103/225 vs. 24.0%, 25/104; 51.9%, 83/160 vs. 28.3%, 17/60) of the LTEVB 12C group were all higher than those of the placebo group, and the differences were statistically significant ( χ2=10.76, 6.39, 9.69, 7.91, 11.05, 9.62, 8.57, 5.20, 7.11, 12.45, and 6.73; all P<0.05). The reversal rates of chronic inflammation at the corpus lesser curvature and corpus greater curvature (5.2%, 12/231 vs. 0, 0/123; 4.7%, 8/170 vs. 0, 0/88), the reversal rates of atrophy at the antrum lesser curvature, antrum greater curvature, corpus lesser curvature, and the corpus greater curvature (6.8%, 22/323 vs. 1.3%, 2/151; 9.2%, 29/315 vs. 1.4%, 2/144; 14.2%, 38/267 vs. 2.5%, 3/121; 20.8%, 35/168 vs. 5.8%, 4/69), and the reversal rates of intestinal metaplasia at the antrum lesser curvature, antrum greater curvature, gastric angle, and the corpus lesser curvature (29.8%, 39/131 vs. 9.1%, 4/44; 41.0%, 32/78 vs. 12.5%, 3/24; 33.3%, 44/132 vs. 4.8%, 3/63; 50.0%, 37/74 vs. 8.7%, 2/23) of the LTEVB 12C group were all higher than those of the placebo group, and the differences were statistically significant ( χ2=6.58, 5.12, 5.60, 8.61, 11.43, 6.59, 7.30, 4.95, 15.92, 7.62; all P<0.05). There were no statistically significant differences in the effective rates and reversal rates of active inflammation at different locations between the LTEVB 12C group and the placebo group (all P>0.05). The results of logistic regression analysis (taking the antrum lesser curvature as the reference) further confirmed that the reversal rates of chronic inflammation ( OR=0.22, 95% confidence interval (95% CI): 0.07 to 0.67; OR=0.24, 95% CI: 0.07 to 0.80), atrophy ( OR=0.28, 95% CI: 0.16 to 0.49; OR=0.28, 95% CI: 0.16 to 0.49), and intestinal metaplasia ( OR=0.42, 95% CI: 0.24 to 0.77; OR=0.20, 95% CI: 0.08 to 0.52) at the corpus lesser curvature and corpus greater curvature were all higher than those at the antrum lesser curvature, and the differences were statistically significant (all P<0.05). There were no statistically siginificant differences in the reversal rates of the aforementioned pathological features between the antrum greater curvature, gastric angle, and the antrum lesser curvature (all P>0.05). Conclusion:LTEVB 12C can achieve good efficacy in the treatment of CAG, and the chronic inflammation, atrophy, and intestinal metaplasia at multiple locations are improved, especially at the corpus lesser curvature and the corpus greater curvature.
4.Fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis
Yamin QIN ; Yipu LI ; Zhanguo SUN ; Yi FANG ; Xinwei HAN ; Dechao JIAO
Journal of Practical Radiology 2025;41(11):1866-1868
Objective To evaluate the feasibility of fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis.Methods Twenty-two patients who underwent Bricker surgery presented with hydronephrosis were selected.Using a catheter-wire technique,percutaneous nephrostomy tract was used to access the uretero-ileal neobladder stric-ture and establish a sheath biopsy channel.Forceps biopsy was performed at the uretero-ileal neobladder anastomotic site,followed by placement of a 10.2F ureteral stent.The technical success rate,complications,biopsy sensitivity,specificity,accuracy were recorded,and preoperative versus postoperative white blood cell counts,creatinine,and urea nitrogen levels were compared.Results The tech-nical success rate was 100%(22/22),with no serious complications,such as ureteral perforation and major bleeding.The accuracy,sensitivity and specificity of the biopsy were 95.45%(21/22),85.71%(6/7)and 100%(15/15),respectively.Preoperative and post-operative white blood cell counts were(9.17±2.16)× 1012/L vs(6.03±1.51)×1012/L,creatinine levels were(219.95±78.47)U/mL vs(78.91±17.23)U/mL,and urea nitrogen levels were(19.85±5.27)U/mL vs(5.95±1.60)U/mL.All three parameters showed statistically significant differences(P<0.05).Conclusion The fluoroscopy-guided anterograde forceps biopsy for diagnosing uretero-ileal neobladder anastomotic stenosis is safe and feasible.
5.Construction of key performance indicator system of clinical quality control for ECMO equipment based on Delphi method
Xuebin CHEN ; Jing ZHAO ; Zhangxi ZHU ; Zhanguo LI ; Yong CUI
China Medical Equipment 2025;22(6):103-107
Objective:To construct a quality control indicator system for the performance of extracorporeal membrane oxygenation(ECMO)equipment during clinical use,and to improve scientific evaluation ability for the reliability of clinical application of ECMO products,so as to provide guarantees for ECMO technical specifications and its reliability in clinical application.Methods:The ECMO industry standard specifications,relative research literature and ECMO equipment operation manuals were retrieved,and the quality control indicators of ECMO performance parameters were summarized and organized.The items of indicators were analyzed through individual interviews and group discussions.Three rounds of expert inquiries were conducted using the Delphi method to construct indicator library of ECMO performance parameters.And then,a key performance indicator system of clinical quality control for ECMO equipment was constructed through analyzed the weight of each indicator.Results:The key performance indicator system of clinical quality control for ECMO equipment included 3 key components(primary indicators)(centrifugal pump,air oxygen mixer,and water tank of variable temperature),6 performance parameters(secondary indicators)(flow rate of blood pump,blood pump speed,oxygen concentration,temperature,pressure pre operating pump,and pressure post operating pump),and 6 performance testing ranges(tertiary indicators),all of which were indicators of quality control for ECMO performance.Conclusion:This research organized an indicator system of clinical quality control for ECMO equipment through analyzed the key performance indicators of ECMO equipment,and constructed quality control template for ECMO in clinical application,and conducted beneficial explorations for the management of quality control for ECMO equipment in clinical application.
6.Construction of key performance indicator system of clinical quality control for ECMO equipment based on Delphi method
Xuebin CHEN ; Jing ZHAO ; Zhangxi ZHU ; Zhanguo LI ; Yong CUI
China Medical Equipment 2025;22(6):103-107
Objective:To construct a quality control indicator system for the performance of extracorporeal membrane oxygenation(ECMO)equipment during clinical use,and to improve scientific evaluation ability for the reliability of clinical application of ECMO products,so as to provide guarantees for ECMO technical specifications and its reliability in clinical application.Methods:The ECMO industry standard specifications,relative research literature and ECMO equipment operation manuals were retrieved,and the quality control indicators of ECMO performance parameters were summarized and organized.The items of indicators were analyzed through individual interviews and group discussions.Three rounds of expert inquiries were conducted using the Delphi method to construct indicator library of ECMO performance parameters.And then,a key performance indicator system of clinical quality control for ECMO equipment was constructed through analyzed the weight of each indicator.Results:The key performance indicator system of clinical quality control for ECMO equipment included 3 key components(primary indicators)(centrifugal pump,air oxygen mixer,and water tank of variable temperature),6 performance parameters(secondary indicators)(flow rate of blood pump,blood pump speed,oxygen concentration,temperature,pressure pre operating pump,and pressure post operating pump),and 6 performance testing ranges(tertiary indicators),all of which were indicators of quality control for ECMO performance.Conclusion:This research organized an indicator system of clinical quality control for ECMO equipment through analyzed the key performance indicators of ECMO equipment,and constructed quality control template for ECMO in clinical application,and conducted beneficial explorations for the management of quality control for ECMO equipment in clinical application.
7.Application of total life cycle management in managing maintenance cost of ultrasound imaging equipment
Zhanguo LI ; Yu WANG ; Huifang YANG ; Jing ZHAO
China Medical Equipment 2025;22(4):174-177
Objective:To explore the application effect of Total Life Cycle Management(TLCM)in managing maintenance cost of ultrasound imaging equipment.Methods:Thirty ultrasound imaging equipment of the China-Japan Friendship Hospital from June 2021 to July 2023 were selected.From June 2021 to June 2022,a conventional maintenance mode was adopted to manage these equipment,and TLCM was implemented to manage them from July 2022 to July 2023.The qualified rate and failure frequency of the ultrasound imaging equipment,the satisfaction scores of medical staffs in using equipment,and the costs of operation and maintenance were compared between different management modes.Results:Under TLCM mode,the qualified rate was 93.33%,which was significantly higher than 73.33% under conventional maintenance mode,and the difference was significant(x2=4.320,P<0.05). Under TLCM mode,the boot-up time of ultrasound imaging equipment was shorter than that under the conventional maintenance mode,and the difference was significant (t=7.146,P<0.05). Under TLCM mode,the failure rate of long-term use of equipment was lower than that under conventional maintenance,and the difference was significant (x2=4.443,P<0.05). The satisfaction scores of medical staffs for the performance,efficiency,and cleanliness of equipment under TLCM mode were higher than those under conventional maintenance mode,and the differences of them between two modes were significant (t=3.955,5.872,6.368,8.214,P<0.05). Under TLCM mode,both maintenance costs and operational expenses were lower than those under conventional maintenance,and the differences of them between two modes were significant (t=41.353,16.743,P<0.05). Conclusion:TLCM can effectively enhance operationally qualified rate of equipment,and reduce maintenance costs and failure rate of equipment in long-term use,and improves the satisfaction of medical staff.
8.Analysis of the efficacy of lamb′s tripe extract and vitamin B 12 capsule on chronic atrophic gastritis at different sites
Dongdong XIA ; Huahong XIE ; Bo JIANG ; Hong XU ; Zhanguo NIE ; Chengwei TANG ; Qiang GUO ; Xiaoping ZOU ; Shuisheng SHI ; Tao SUN ; Shourong SHEN ; Guoqing LI ; Xiaozhong GUO ; Xiaoyan ZHAO ; Jiaming QIAN ; Weixing CHEN ; Guiying ZHANG ; Aijun LIAO ; Jingyuan FANG ; Daiming FAN ; Kaichun WU
Chinese Journal of Digestion 2025;45(3):162-168
Objective:To evaluate the efficacy of lamb′s tripe extract and vitamin B 12 capsule (LTEVB 12C) on chronic atrophic gastritis (CAG) at different locations (antrum lesser curvature, antrum greater curvature, gastric angle, corpus lesser curvature, and corpus greater curvature). Methods:From August 2011 to January 2013, 715 patients with CAG in a multicenter, randomized, double-blind, placebo-controlled trial were enrolled from 16 tertiary first-class hospitals across the country, including the First Affiliated Hospital of Air Force Medical University, Nanfang Hospital of Southern Medical University, the First Hospital of Jilin University, West China Hospital of Sichuan University, etc., there were 476 cases in the LTEVB 12C group and 239 cases in the placebo group. The patients of the LTEVB 12C group received LTEVB 12C, and the patients of placebo group received LTEVB 12C mimetic, all the medications were taken 3 capsules each time and 3 times a day after meals, and the treatment course of 2 groups were both 6 months. The efficacy evaluation criteria included the effective rate (a decrease of ≥1 in histopathological score compared with baseline after 6 months of treatment) and the reversal rate (a decrease of ≥ 2 in histopathological score compared with baseline after 6 months of treatment in the patients with moderate to severe CAG). The impact of lesion sites on the therapeutic effects of LTEVB 12C was analyzed by logistic regression analysis. The two-way unordered Cochran-Mantel-Haenszel chi-square test considering the center effect and Pearson chi-square test were used for statistical analysis. Results:The effective rates of chronic inflammation at the antrum greater curvature and corpus greater curvature (23.3%, 110/473 vs. 13.0%, 31/239; 20.3%, 96/472 vs. 12.6%, 30/239), the effective rates of atrophy at the antrum lesser curvature, antrum greater curvature, gastric angle, corpus lesser curvature, and the corpus greater curvature (27.0%, 118/437 vs. 15.7%, 34/216; 29.2%, 126/432 vs. 18.5%, 38/205; 27.8%, 121/435 vs. 16.7%, 36/216; 32.5%, 127/391 vs. 19.8%, 37/187; 33.0%, 119/361 vs. 21.8%, 39/179), and the effective rates of intestinal metaplasia at the antrum lesser curvature, antrum greater curvature, gastric angle, and the corpus lesser curvature (45.0%, 112/249 vs. 29.8%, 31/104; 53.8%, 86/160 vs. 33.9%, 21/62; 45.8%, 103/225 vs. 24.0%, 25/104; 51.9%, 83/160 vs. 28.3%, 17/60) of the LTEVB 12C group were all higher than those of the placebo group, and the differences were statistically significant ( χ2=10.76, 6.39, 9.69, 7.91, 11.05, 9.62, 8.57, 5.20, 7.11, 12.45, and 6.73; all P<0.05). The reversal rates of chronic inflammation at the corpus lesser curvature and corpus greater curvature (5.2%, 12/231 vs. 0, 0/123; 4.7%, 8/170 vs. 0, 0/88), the reversal rates of atrophy at the antrum lesser curvature, antrum greater curvature, corpus lesser curvature, and the corpus greater curvature (6.8%, 22/323 vs. 1.3%, 2/151; 9.2%, 29/315 vs. 1.4%, 2/144; 14.2%, 38/267 vs. 2.5%, 3/121; 20.8%, 35/168 vs. 5.8%, 4/69), and the reversal rates of intestinal metaplasia at the antrum lesser curvature, antrum greater curvature, gastric angle, and the corpus lesser curvature (29.8%, 39/131 vs. 9.1%, 4/44; 41.0%, 32/78 vs. 12.5%, 3/24; 33.3%, 44/132 vs. 4.8%, 3/63; 50.0%, 37/74 vs. 8.7%, 2/23) of the LTEVB 12C group were all higher than those of the placebo group, and the differences were statistically significant ( χ2=6.58, 5.12, 5.60, 8.61, 11.43, 6.59, 7.30, 4.95, 15.92, 7.62; all P<0.05). There were no statistically significant differences in the effective rates and reversal rates of active inflammation at different locations between the LTEVB 12C group and the placebo group (all P>0.05). The results of logistic regression analysis (taking the antrum lesser curvature as the reference) further confirmed that the reversal rates of chronic inflammation ( OR=0.22, 95% confidence interval (95% CI): 0.07 to 0.67; OR=0.24, 95% CI: 0.07 to 0.80), atrophy ( OR=0.28, 95% CI: 0.16 to 0.49; OR=0.28, 95% CI: 0.16 to 0.49), and intestinal metaplasia ( OR=0.42, 95% CI: 0.24 to 0.77; OR=0.20, 95% CI: 0.08 to 0.52) at the corpus lesser curvature and corpus greater curvature were all higher than those at the antrum lesser curvature, and the differences were statistically significant (all P<0.05). There were no statistically siginificant differences in the reversal rates of the aforementioned pathological features between the antrum greater curvature, gastric angle, and the antrum lesser curvature (all P>0.05). Conclusion:LTEVB 12C can achieve good efficacy in the treatment of CAG, and the chronic inflammation, atrophy, and intestinal metaplasia at multiple locations are improved, especially at the corpus lesser curvature and the corpus greater curvature.
9.Fluoroscopy-guided Fustar adjustable bent sheath clamp biopsy for diagnosing obstructive esophageal diseases
Yipu LI ; Mengyao SONG ; Rongna HOU ; Chengzhi ZHANG ; Zhanguo SUN ; Dechao JIAO
Chinese Journal of Interventional Imaging and Therapy 2024;21(10):580-582
Objective To observe the feasibility and effectiveness of fluoroscopy-guided Fustar adjustable bent sheath clamp biopsy for diagnosing obstructive esophageal diseases.Methods Totally 29 patients with esophageal or esophagogastric junction obstruction who failed to complete endoscopic biopsy were retrospectively analyzed.Real-time fluoroscopy-guided clamp biopsy of lesion areas were performed through 10F Fustar adjustable bent sheath under local anesthesia.The technical success rate,operation time,radiation dose were recorded,and the complications were evaluated.Results Clamp biopsy of lesion areas were successfully performed in all 29 cases,with technical success rate of 100%(29/29),the average operation time of(29.81±10.05)min and the average radiation dose of(127.14±100.36)mGy.No serious complication such as esophageal perforation nor massive bleeding occurred.After biopsy,22 cases(22/29,75.86%)were preliminarily diagnosed as positive,among them 2 cases underwent surgical operation,and the postoperative pathological results were consistent with biopsy.Negative biopsy results were found in 7 cases(7/29,24.14%),among them 2 cases underwent clamp biopsy again 3 months later which showed positive results.Conclusion Fustar adjustable bent sheath clamp biopsy was feasible and effective for diagnosing obstructive esophageal diseases,which could be regarded as the substitution and supplementation of endoscopic clamp biopsy.
10.The value of magnetic resonance imaging and pathological multi parameters in predicting the efficacy of neoadjuvant chemotherapy for advanced breast cancer
Zhengtong WANG ; Fan ZHAO ; Chongchong LI ; Yueqin CHEN ; Zhanguo SUN ; Hao YU ; Zhitao SHI ; Lin CHEN ; Weiwei WANG
Journal of Chinese Physician 2024;26(9):1343-1349
Objective:To explore the value of conventional magnetic resonance imaging (MRI), diffusion weighted imaging (DWI), diffusion kurtosis imaging (DKI) sequence and pathological examination in predicting the efficacy of neoadjuvant chemotherapy (NAC) in advanced breast cancer.Methods:The clinical data of 65 cases of advanced breast cancer with NAC confirmed by pathology in the Affiliated Hospital of Jining Medical University from March 2022 to May 2023 were retrospectively analyzed, including 20 cases in the pathological complete remission (pCR) group and 45 cases in the non pCR group; All patients underwent routine MRI, DWI, DKI examinations and pathological analysis. The clinical pathological data, routine MRI features, apparent diffusion coefficient (ADC) values, mean kurtosis coefficient (MK), and mean diffusion coefficient (MD) between the two groups were analyzed; We compared the differences in various parameters between two groups and plotted receiver operating characteristic (ROC) curves to compare their diagnostic efficacy of NAC in breast cancer.Results:There were significant differences in molecular typing, estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (Her-2) and Ki-67 between pCR group and non pCR group (all P<0.05). In pCR group, Her-2 overexpression type and triple negative breast cancer (TNBC) type breast cancer were more common. ER and PR were mostly negative, Her-2 was mostly positive, and Ki 67 was mainly positive. The difference in tumor T2WI signal between the pCR group and the non pCR group was statistically significant ( P<0.05), with the pCR group showing mostly moderate/low T2WI signal. The ADC and MD values of the pCR group were lower than those of the non pCR group, while the MK value of the pCR group was higher than that of the non pCR group, and the differences were statistically significant (all P<0.001). The area under the ROC curve (AUC) for predicting the efficacy of NAC using a clinical pathological model was 0.829, which was higher than the AUC of molecular subtypes, ER, PR, Her-2, and Ki-67 ( Z=3.008, 2.697, 2.815, 2.131, 2.376, all P<0.05); The AUC of the DKI+ DWI predicting the efficacy of NAC was 0.934, which was higher than that of the DWI single sequence model, and the difference in type was statistically significant ( Z=2.396, P=0.017). The diagnostic efficacy of the DKI+ DWI model was higher than that of the single parameter ADC, MD, and MK, and the differences were statistically significant ( Z=2.396, 2.219, 2.161, all P<0.05); The AUC of the combined imaging and pathology model was 0.983, and its diagnostic efficacy was higher than that of the conventional MRI feature model, pathology model, DWI model, and DKI model, with statistically significant differences ( Z=5.877, 2.961, 3.240, 2.264, all P<0.05). Conclusions:The results of pathology, conventional MRI, DWI and DKI parameters of pCR and non pCR breast cancer patients are significantly different, and the combined model is better than the single model in predicting the efficacy of NAC.