1.Quality Evaluation of Black Panacis Quinquefolii Radix Based on Neuroprotective Spectrum-effect Relationship
Yuting YANG ; Shuyun LIANG ; Shanshan LI ; Yulong YANG ; Ziqi YANG ; Guangzhi CAI ; Liru ZHAO ; Jiyu GONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(18):149-156
ObjectiveTo clarify the neuroprotective effect of black Panacis Quinquefolii Radix(PQR) and explore its active ingredients, with the aim of establishing an activity-oriented quality evaluation method. MethodsTransgenic Tg(HuC∶EGFP) zebrafish was used to establish a neuronal injury model by aluminum chloride immersion. Different doses(10, 20 mg·L-1) of PQR and black PQR ethanol extracts were administered. The neuroprotective effects of PQR and black PQR were compared by analyzing the fluorescent area and intensity of zebrafish neurons. Based on ultra-performance liquid chromatography(UPLC), a fingerprint profile of black PQR was established, followed by principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA). Differential components were screened using the criteria of variable importance in the projection(VIP) value>1 and P<0.05. The neuroprotective activity of 14 batches of black PQR was assessed, and Spearman correlation analysis was used to identify saponins related to neuroprotective activity, which were then validated. Based on the above results, active marker components were determined, and an UPLC method was established for their quantitation with clear content limits. ResultsPharmacological efficacy results showed that both PQR and black PQR at different doses could significantly improved neuronal damage in zebrafish. At a dose of 20 mg·L-1, black PQR demonstrated superior efficacy(P<0.05). The fingerprint similarities of 14 batches of black PQR were>0.94, with 26 common peaks identified. Through comparison with the reference standards, 8 components were confirmed, including peak 1(ginsenoside Rg1), peak 2(ginsenoside Re), peak 5(ginsenoside Rb1), peak 9(ginsenoside Rd), peak 16[ginsenoside 20(S)-Rg3], peak 17[ginsenoside 20(R)-Rg3], peak 18(ginsenoside Rk1), and peak 19(ginsenoside Rg5). The results of PCA and OPLS-DA indicated that there were differences in saponins among black PQR samples from different origins, and 12 differential components were screened. All 14 batches of black PQR exhibited good protective effects on zebrafish neurons, with Shaanxi-produced black PQR showing superior protective effects compared to the other three production regions. Spearman correlation analysis revealed that a total of 11 components, including ginsenosides 20(S)-Rg3, 20(R)-Rg3, Rk1 and Rg5, showed a significant positive correlation with the neuroprotective effect in zebrafish(P<0.05). The activity validation results indicated that ginsenosides 20(S)-Rg3, 20(R)-Rg3, Rk1 and Rg5 were the primary components responsible for the neuroprotective effects of black PQR. Quantitative analysis showed that the content of ginsenoside 20(S)-Rg3 in 14 batches of black PQR ranged from 0.17% to 0.52%, and the repair rate of neuronal damage ranged from 42.77% to 97.83%. ConclusionBased on the fingerprint and neuronal protective activity, the spectrum-effect related quality control model of black PQR was established, with ginsenoside 20(S)-Rg3 as the quality control index, and the neuronal damage repair rate≥60% as the evaluation standard, the minimum limit of ginsenoside 20(S)-Rg3 in black PQR should be≥0.20%.
2.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
3.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.
4.Clinical efficacy of transcatheter edge-to-edge repair in patients with non-central degenerative mitral regurgitation
Peijian WEI ; Junke CHANG ; Jianrui MA ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shiguo LI ; Fujian DUAN ; Wenbin OUYANG ; Shouzheng WANG ; Fang FANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(4):373-381
Objective:To evaluate the clinical efficacy of mitral valve transcatheter edge-to-edge repair (TEER) in patients with non-central degenerative mitral regurgitation (DMR).Methods:This retrospective study included patients with non-central DMR who underwent TEER at Fuwai Hospital between January 2021 and February 2024. Patients were categorized into two groups: the commissure-involved group and the non-commissure group, based on whether the mitral valve commissures were involved. Clinical data, surgical outcomes, and echocardiographic findings at 3 months postoperatively were collected and compared, and patients were followed up. The primary endpoint was the procedural success rate at discharge.Results:A total of 59 patients were included, aged (68.6±9.3) years, including 23 females (39%). In the overall study population, 78% (46/59) of patients had severe mitral regurgitation. Forty-two cases were in the non-commissure group, and 17 cases were in the commissure-involved group. Patients in the non-commissure group mainly had lesions in the A1/P1 region, while patients in the commissure-involved group mainly had lesions in the A3/P3 region. There was no significant difference in the procedural success rate at discharge (93% vs. 88%, P=0.95) and the incidence of postoperative complications (5% vs. 6%, P=1.00) between the two groups. Two patients in the commissure-involved group experienced single leaflet device attachment, with one of them requiring conversion to surgical mitral valve surgery; In the non-commissure group, two patients experienced single-valve clamping, and one of them was converted to surgical mitral valve surgery. The follow-up time of the entire cohort was (15.5±10.3) months. In the non-commissure group, 2 patients died and 2 were readmitted. While in the commissure-involved group, no patients died and only 1 patient was readmitted. Conclusion:TEER is an effective treatment for patients with non-central DMR involving the commissures, without increasing the incidence of postoperative complications.
5.Consistency Evaluation of Processing of Black Panacis Quinquefolii Radix Decoction Pieces Based on "Chromaticity-chemistry-activity"
Yulong YANG ; Shanshan LI ; Yuting YANG ; Ziqi YANG ; Guangzhi CAI ; Liru ZHAO ; Jiyu GONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(20):195-203
ObjectiveTo assess the quality consistency of black Panacis Quinquefolii Radix(bPQR) decoction pieces prepared by atmospheric and pressurized steaming processes based on chromaticity-chemical composition-vasoactive inhibition. The ultimate goal was to screen the pressurized steaming process yielding quality equivalent to atmospheric steaming, and optimize the processing technology of bPQR. MethodsThe bPQR decoction pieces were prepared using both atmospheric and pressurized steaming processes, and the chromaticity values[lightness value(L*), red/green chromaticity value(a*), yellow/blue chromaticity value(b*), total chromaticity value(E*ab)] were measured. High performance liquid chromatography(HPLC) was employed to establish fingerprint profiles for the decoction pieces, and cluster analysis was conducted on chromaticity values and the common peak areas in fingerprint profiles to elucidate the quality relationships between the decoction pieces processed by different methods. The optimal atmospheric steaming of bPQR decoction pieces was determined through zebrafish angiogenesis inhibition experiments. The contents of ginsenosides Rg1, Re, Rb1, 20(S)-Rg3, Rk1 and Rg5 in the decoction pieces were quantified, and Spearman correlation analysis was employed to investigate the relationship between saponin content, chromaticity, and angiogenesis inhibition activity during the steaming process. By integrating the consistency of chromaticity, saponin components and angiogenesis inhibition activity, pressurized steaming conditions with quality equivalent to the atmospheric pressure method were selected. ResultsCompared with the atmospheric steaming method, pressurized steaming resulted in faster color darkening and higher conversion rates of ginsenosides in bPQR decoction pieces. Moreover, the neovascularization inhibitory activity of bPQR decoction pieces continued to increase with the deepening of processing. Based on the effectiveness and safety, the optimal process for preparing bPQR decoction pieces with neovascularization inhibitory activity was determined to be atmospheric steaming for 21 h. All six ginsenosides tested exhibited strong to extremely strong correlations with both the chromaticity values of the decoction pieces and their neovascularization inhibitory activities. Among them, ginsenosides Rg1, Re and Rb1 exhibited positive correlations with chromaticity values and negative correlations with zebrafish angiogenesis inhibition activity. Conversely, ginsenosides 20(S)-Rg3, Rk1 and Rg5 showed negative correlations with chromaticity values and positive correlations with zebrafish angiogenesis inhibition activity. By integrating chromaticity values, cluster analysis results, as well as the results of activity, it was determined that the quality of bPQR decoction pieces steamed under pressurized conditions of 110 ℃(0.045 MPa) for 5 h and 115 ℃(0.07 MPa) for 3 h was highly consistent with that obtained by atmospheric steaming for 21 h. ConclusionThe preparation of bPQR decoction pieces by pressurized steaming has the advantages of short preparation time, low energy consumption, and rapid saponin conversion rate, making it a viable alternative to atmospheric steaming for preparing bPQR decoction pieces. Meanwhile, the evaluation method based on chromaticity-chemical composition-activity can provide a more scientific and effective explanation of change rules in the quality during traditional Chinese medicine processing, and offer a new model for optimizing processing technology and enhancing quality control.
6.Specification for postoperative care and treatment after transcatheter aortic valve replacement
Peide ZHANG ; Yuxin FAN ; Mian XU ; Siyu LIU ; Guangzhi ZHAO ; Shuo CHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(09):1203-1208
Since the first successful transcatheter aortic valve replacement (TAVR) was performed globally in 2002, the TAVR technology has become increasingly mature. With more than a decade of development in China, its application experience, device research and development, procedural improvements, evidence-based medicine, and guideline updates have continuously progressed, leading to a significant increase in the number of procedures conducted. Compared to traditional surgical operations, TAVR has different postoperative monitoring points and principles for the prevention and management of complications, necessitating the formulation of corresponding monitoring and treatment protocols that align with the technical characteristics of the procedure. This guideline is based on clinical practice and incorporates both domestic and international literature as well as the experiences of Fuwai Hospital. It distills and organizes routine postoperative monitoring practices, process optimization, and complication management for TAVR, establishing a set of practical guidelines for postoperative monitoring in China. These guidelines have strong practical value for optimizing postoperative management strategies and preventing and managing complications, which is beneficial for early functional recovery of patients, shortening hospital stays, and reducing complication rates. They provide guidance and reference for domestic peers and support the standardized development and quality improvement of postoperative management for TAVR in China.
7.Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report
Ying' ; ao ZHAO ; Yiming YAN ; Ziping LI ; Hang LI ; Fengwen ZHANG ; Fang FANG ; Guangzhi ZHAO ; Jing DONG ; Chuangshi WANG ; Jiande WANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1796-1799
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
8.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
9.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
10.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.

Result Analysis
Print
Save
E-mail