1.2024 annual report of interventional treatment for congenital heart disease
Changdong ZHANG ; Yucheng ZHONG ; Geng LI ; Jun TIAN ; Gejun ZHANG ; Nianguo DONG ; Yuan FENG ; Daxin ZHOU ; Yongjian WU ; Lianglong CHEN ; Xiaoke SHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(07):909-918
In recent years, with the continuous development and increasing maturity of interventional techniques, interventional treatment for congenital heart disease (CHD) has been progressively disseminated to county- and city-level hospitals in China. Concurrently, the standardized management of adult CHD (particularly patent foramen ovale) and the lifelong management of complex CHD are gaining increasing clinical attention, while the emergence of new techniques and products continuously advances the discipline. This article aims to review the new progress made in the field of interventional treatment for congenital heart disease in China during 2024. It specifically reviews and analyzes the following key aspects: (1) annual statistics on interventional closure procedures for CHD; (2) recent insights into patent foramen ovale closure; (3) advances in transcatheter pulmonary valve replacement; (4) interventional treatment and lifelong management strategies for complex CHD; (5) new interventional techniques for acquired heart disease; and (6) the application of artificial intelligence in CHD management. Through the synthesis and discussion of these topics, this article seeks to provide a detailed analysis of the current landscape of interventional treatment for CHD in China and project its future development trends.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Short-term outcomes of transcatheter pulmonary valve replacement with Venus-P valve in patients with moderate-to-severe pulmonary regurgitation and right ventricular systolic dysfunction.
Haiyue XIE ; Wenhao ZHU ; Zhiyuan XIA ; Gejun ZHANG
Journal of Zhejiang University. Medical sciences 2025;54(3):390-398
OBJECTIVES:
To evaluate the short-term outcomes of transcatheter pulmonary valve replacement (TPVR) using the Venus-P valve in patients with moderate-to-severe pulmonary regurgitation and right ventricular systolic dysfunction (RVSD) following surgical repair of complex congenital heart disease.
METHODS:
A retrospective analysis was conducted on patients undergoing Venus-P valve implantation (TPVR group, n=28) or surgical pulmonary valve replacement (SPVR group, n=19) at Fuwai Hospital between February 2014 and February 2024. All patients had moderate-to-severe pulmonary regurgitation with right ventricular ejection fraction less than 45% preoperatively. Postoperative pulmonary valve function and ventricular parameters were assessed at discharge and during a 6-month follow-up.
RESULTS:
All procedures were successfully completed with no early mortality. At 6 months, the TPVR group demonstrated significantly lower pulmonary valve transvalvular pressure gradients compared to the SPVR group (P<0.05). Both groups exhibited significant improvements from baseline in New York Heart Association (NYHA) functional class, biventricular ejection fractions, and right ventricular end-diastolic volume index (all P<0.05). The reduction in right ventricular end-diastolic diameter differed between the two groups (P<0.01). However, multivariable analysis revealed no association between this difference and surgical approach (β=4.4, P>0.05). In the TPVR group, QRS duration was significantly shortened postoperatively (P<0.01), with improvements in left ventricular end-diastolic volume index and cardiac index (both P<0.01), but these improvements did not differ significantly from the SPVR group (all P>0.05). During the follow-up, one patient in each group developed infective endocarditis within 1-month post-procedure; both were successfully treated with antibiotics. No other major complications were observed.
CONCLUSIONS
For patients with moderate-to-severe pulmonary regurgitation and RVSD, TPVR using the Venus-P valve effectively improves short-term pulmonary valve function and ventricular performance with a favorable safety profile, demonstrating potential as a minimally invasive alternative to SPVR .
Humans
;
Pulmonary Valve Insufficiency/surgery*
;
Retrospective Studies
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Ventricular Dysfunction, Right/physiopathology*
;
Treatment Outcome
;
Female
;
Male
;
Child
;
Adult
;
Heart Valve Prosthesis
;
Adolescent
;
Cardiac Catheterization/methods*
;
Child, Preschool
7.Effectiveness of Transcatheter Closure Treatment of Ventricular Septal Defect Without Distance From the Aortic Valve With Eccentric Occluder
Zirui SUN ; Yu HAN ; Shubo SONG ; Yan HAN ; Lele BEN ; Taibing FAN ; Gejun ZHANG
Chinese Circulation Journal 2025;40(8):795-798
Objectives:To evaluate the feasibility and clinical efficacy of eccentric occluder for the treatment of ventricular septal defect(VSD)without distance from the aortic valve.Methods:This analysis included 16 patients(9 males and 7 females)with VSD without distance from the aortic valve,who were treated at Fuwai Central China Cardiovascular Hospital from February 2022 to June 2024.Ten cases had mild right coronary sinus prolapse,and 2 had mild aortic valve regurgitation.All patients were diagnosed with VSD located zero-distance from aortic valve through transthoracic echocardiography(TTE)and left ventricular angiography.Eccentric occluder was used for interventional closure.TTE and 12-lead electrocardiography(ECG)were performed at 1 month,3 months,and 6 months after surgery to observe the presence of residual shunt,aortic valve regurgitation,and cardiac electrical conduction abnormalities.Results:Transcatheter closure was successful in 15 patients,procedure failed in one patient due to the unstable fixation of the occluder.Average diameter of the defect is(4.37±1.53)mm,and the diameter of the occluder is 6.5(6.0,8.0)mm.Postoperative left ventricular angiography showed minimal residual shunt in 3 cases,and no complications such as pericardial tamponade,hemolysis,thromboembolism,or infection,were observed.At one month after occlusion,TTE results showed that residual shunt disappeared in 3 patients with residual shunt.During 3-month and 6-month follow-up,all the occluders were well-positioned with no new aortic valve regurgitation or worsening of the original regurgitation,and no atrioventricular block or bundle branch block and other electrocardiographic conduction abnormalities.Conclusions:The use of eccentric occluder for intervention of ventricular septal defect patients without distance from the aortic valve is safe and effective.
8.Effectiveness of Transcatheter Closure Treatment of Ventricular Septal Defect Without Distance From the Aortic Valve With Eccentric Occluder
Zirui SUN ; Yu HAN ; Shubo SONG ; Yan HAN ; Lele BEN ; Taibing FAN ; Gejun ZHANG
Chinese Circulation Journal 2025;40(8):795-798
Objectives:To evaluate the feasibility and clinical efficacy of eccentric occluder for the treatment of ventricular septal defect(VSD)without distance from the aortic valve.Methods:This analysis included 16 patients(9 males and 7 females)with VSD without distance from the aortic valve,who were treated at Fuwai Central China Cardiovascular Hospital from February 2022 to June 2024.Ten cases had mild right coronary sinus prolapse,and 2 had mild aortic valve regurgitation.All patients were diagnosed with VSD located zero-distance from aortic valve through transthoracic echocardiography(TTE)and left ventricular angiography.Eccentric occluder was used for interventional closure.TTE and 12-lead electrocardiography(ECG)were performed at 1 month,3 months,and 6 months after surgery to observe the presence of residual shunt,aortic valve regurgitation,and cardiac electrical conduction abnormalities.Results:Transcatheter closure was successful in 15 patients,procedure failed in one patient due to the unstable fixation of the occluder.Average diameter of the defect is(4.37±1.53)mm,and the diameter of the occluder is 6.5(6.0,8.0)mm.Postoperative left ventricular angiography showed minimal residual shunt in 3 cases,and no complications such as pericardial tamponade,hemolysis,thromboembolism,or infection,were observed.At one month after occlusion,TTE results showed that residual shunt disappeared in 3 patients with residual shunt.During 3-month and 6-month follow-up,all the occluders were well-positioned with no new aortic valve regurgitation or worsening of the original regurgitation,and no atrioventricular block or bundle branch block and other electrocardiographic conduction abnormalities.Conclusions:The use of eccentric occluder for intervention of ventricular septal defect patients without distance from the aortic valve is safe and effective.
9.Early outcome of balloon-expandable valves in the treatment of severe aortic stenosis: A single-center study
Yihang LI ; Jingnan ZHANG ; Fang FANG ; Junyi WAN ; Liang XU ; Xiangbin PAN ; Gejun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(07):1007-1013
Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. Conclusion The use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.
10.In vitro bench testing using patient-specific 3D models for percutaneous pulmonary valve implantation with Venus P-valve
Yu HAN ; Zehua SHAO ; Zirui SUN ; Yan HAN ; Hongdang XU ; Shubo SONG ; Xiangbin PAN ; De Jaegere Peter P. T. ; Taibing FAN ; Gejun ZHANG
Chinese Medical Journal 2024;137(8):990-996
Background::Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. Methods::Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University.Results::3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) ( n = 2) or risk of compression coronary artery ( n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). Conclusions::In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.

Result Analysis
Print
Save
E-mail