1.Analysis of influencing factors on clinical pregnancy outcomes in patients with hydrosalpinx undergoing in vitro fertilization-embryo transfer after interventional embolization
Kai ZHANG ; Zhiwei CHENG ; Hongwu QIAO ; Yunxiao ZHI ; Xin ZHAO ; Yichun GUAN ; Lin LU ; Xiangting LIU ; Guangying NIU ; Yaping WANG
Chinese Journal of Radiology 2024;58(9):929-934
Objective:To explore the influencing factors of clinical pregnancy outcomes in patients with hydrosalpinx undergoing in vitro fertilization-embryo transfer(IVF-ET) after interventional embolization and whether residual hydrops has an adverse impact on pregnancy outcomes.Methods:Clinical data from 65 patients who underwent interventional embolization and IVF-ET for hydrosalpinx at the Third Affiliated Hospital of Zhengzhou University from March 2021 to October 2022 were collected retrospectively. The hydrops index was quantified by the ratio of the widest diameter to the pelvic transverse diameter of the intraoperative hydrops, and the patient′s age, body mass index(BMI), follicle-stimulating hormone(FSH), lutenizing hormine(LH), estradiol(E2), automated matetials hangling(AMH), endometrial thickness at the time of transplantation, the number of transplanted embryos, embryo type, and location of the hydrosalpinx were recorded. In addition, the clinical pregnancy outcomes of the first transplantation after embolization were followed. Two independent samples t-test, rank sum test and chi-square test were used to analyze the difference of the above indexes among different clinical pregnancy outcomes by SPSS 25.0. The receiver operating characteristic (ROC) curves and Youden index were used to calculate the cut-off value of the water accumulation index. Results:Among 65 patients, the clinical pregnancy rate was 63.1%(41/65), among the 45 patients who underwent embryo transfer before embolization without success, the clinical pregnancy rate after embolization was 62.2%(28/45). Based on data analysis, it showed that IVF-ET clinical pregnancy outcomes were not associated with age, BMI, FSH, LH, E2, AMH, endometrial thickness at the time of transplantation, the number of transplanted embryos, embryo type, as well as location of hydrosalpinx( P>0.05), but associated with hydrosalpinx index( P<0.001). ROC curve analysis showed that the hydrops index could be used as a predictor of pregnancy outcome, and the area under the curve was 0.825, and the optimal cut-off value of the hydrops index was 12.925% based on the Youden index analysis result. Conclusions:Interventional embolization of hydrosalpinx may improve clinical pregnancy rates. When the hydrosalpinx is large enough, it could adversely affected IVF-ET clinical pregnancy, and further aspiration of hydrosalpinx should be performed prior to transplantation.
2.Effects of mindfulness-based stress reduction therapy on fear of the disease progression, sleep and quality of life in patients with acute ischemic stroke
Xiongpo LIN ; Yunxiao LIU ; Jinghua MA ; Jing ZHAO ; Zilan HAO
Chinese Journal of Practical Nursing 2024;40(3):167-173
Objective:To explore the effects of mindfulness-based decompression therapy on fear of disease progression, quality of life and sleep quality in patients with acute ischemic stroke, in order to provide intervention measures to alleviate fear of the disease progression degree and improve sleep and quality of life in patients with acute ischemic stroke.Methods:This study was a randomized controlled study. Using the convenience sampling method, 98 patients with acute ischemic stroke who attended the Department of Neurology at the Third Hospital of Hebei Medical University from November 2021 to September 2022 were selected for the study, and the study population was divided into experimental group ( n=49) and control group ( n=49) using the random number table method. The control group received conventional care, and the experimental group received mindfulness-based stress reduction therapy for 8 weeks in addition to conventional care. Compared the scores of the Fear of Progression Questionnaire-Short Form (FoP-Q-SF), Stroke-Specific Quality of Life Scale (SS-QOL), and Pittsburgh Sleep Quality Index (PSQI) between the two groups of patients before and after intervention using two independent sample t-tests, and further compared the score spread of each scale before and after intervention between the two groups of patients using Mann-Whitney U test. Results:In the experimental group, 4 cases fell off and 3 cases had imperfect questionnaire information, while in the control group, 2 cases fell off and 5 cases had imperfect questionnaire information. Finally, 42 cases were included in each group. The 23 males and 19 females in the control group aged (48.31 ± 7.61) years old, while 25 males and 17 females in the experimental group aged (50.19 ± 8.64) years old. There was no significant difference in FoP-Q-SF, SS-QOL and PSQI scores between the two groups before intervention (all P>0.05). After intervention, the scores of FoP-Q-SF and PSQI in the experimental group (35.79 ± 7.04, 7.19 ± 2.58) were lower than those in the control group (38.52 ± 4.02, 9.45 ± 2.28), while the SS-QOL score (200.36 ± 21.75) was higher than that in the control group (185.41 ± 15.90), the differences were statistically significant ( t=2.19, -4.26, 3.60, all P<0.05). After intervention, the scores of FoP-Q-SF and PSQI in the experimental group were lower than those before intervention (39.69 ± 4.15, 10.00 ± 2.85), while the SS-QOL score was higher than that before intervention (176.93 ± 23.54), the differences were statistically significant ( t=4.80, 10.45, -11.43, all P<0.05). The score spreads of FoP-Q-SF, SS-QOL, and PSQI in the experimental group before and after intervention were 1.00 (0.00, 9.25), 20.00 (12.75, 32.75), 3 (1, 4), which were higher than 1.00 (-1.25, 2.00), 5.50 (1.00, 10.25), 0 (-1, 2) in the control group, the differences were statistically significant ( Z=-2.30, -5.74, -5.53, all P<0.05). Conclusions:Mindfulness-based decompression therapy can effectively relieve the fear of disease progression and improve the quality of sleep and life in patients with acute ischemic stroke.
3.Correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis
Yunxiao YANG ; Chenglan HUANG ; Yutong HOU ; Yuan YAO ; Yu ZHAO ; Yuanjing XU ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3879-3884
BACKGROUND:Patients with degenerative cervical spondylosis often suffer from changed varicosity of the cervical spine,unbalanced neck-shoulder muscular strength,and descending power. OBJECTIVE:To probe into the correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis. METHODS:Totally 50 patients with degenerative cervical spondylosis received treatment at the 3D Printed Outpatient Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2022 to March 2023 were included in the study.After excluding the 10 patients of cervical lateral projection that failed to meet the measurement conditions,the cervical lateral projections were shot to measure the following iconography parameters:Borden value and C2-7 Cobb angle as well as pain thresholds on the midpoint of the superior trapezius muscle in bilateral bundles and at 1 cm beside the C5-6 interspike.The correlation between sagittal curvature parameters and pain threshold of neck-shoulder muscles in degenerative cervical spondylosis was analyzed. RESULTS AND CONCLUSION:(1)The Borden value of sagittal curvature showed a moderately positive correlation with the bundle pain threshold in the left upper trapezius muscle,the bundle pain threshold in the right upper trapezius muscle,and the pain threshold at the 1 cm of the left side beside the C5-6 interspike(r=0.498,P<0.01;r=0.448,P<0.05;r=0.405,P<0.05)and a weak positive correlation with the pain threshold at the 1 cm of the right side beside the C5-6 interspike(r=0.322,P<0.05).(2)The C2-7 Cobb angle showed a weak positive correlation with the left squared myalgia threshold(r=0.355,P<0.05),and there was no correlation with the pain threshold of the left trapezius muscle and the pain threshold at the 1 cm of both sides beside the C5-6 interspike.(3)There was a correlation between the pain threshold of the neck-shoulder muscles,and a high correlation between the pain threshold of the left and right muscles and the pain threshold within the left and right side muscles,indicating that the neck-shoulder muscles are consistent and may be related to the coordination of the neck-shoulder movements.
4.3D printed personalized cervical orthopedic brace can alleviate and treat early cervical spondylosis
Yunxiao YANG ; Yu ZHAO ; Minghai WANG ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(29):4639-4644
BACKGROUND:Short-term wearing of cervical brace combined with shoulder and neck muscle exercise can significantly improve the symptoms of early cervical spondylosis.After stopping wearing cervical brace,patients'symptoms are easy to recur,which may be due to the lack of cervical curvature correction function. OBJECTIVE:To analyze the effect of 3D printed personalized cervical orthopedic brace for adjusting cervical curvature in the treatment of early cervical spondylosis. METHODS:From January 2021 to January 2023,30 patients with early cervical spondylosis in the Shanghai Fifth People's Hospital,Fudan University were studied,including 11 males and 19 females,with a mean age of(31.7±6.6)years old.All patients customized and wore 3D printed personalized cervical orthopedic braces for 3 hours a day for continuous 12 weeks.Borden value of cervical curvature,pain threshold of shoulder and neck muscles,cervical dysfunction index,and visual analog scale score in 30 patients were recorded before and 4 and 8 weeks after treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,the difference of Borden value of cervical curvature,right trapezius tenderness threshold,and cervical dysfunction index was not significant in 30 patients after 4 weeks of treatment(P>0.05).Visual analog scale score,left trapezius tenderness threshold,left and right C5C6 tenderness threshold were significantly improved(P<0.05).(2)Compared with before treatment,the cervical curvature Borden value,left and right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold,and cervical dysfunction index of 30 patients were significantly improved after 12 weeks of treatment(P<0.05).(3)Compared with 4 weeks after treatment,the Borden value of cervical curvature,right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold and cervical dysfunction index of 30 patients after 12 weeks of treatment were significantly improved(P<0.05).(4)The results show that short-term wearing of 3D printed personalized cervical orthopedic brace can improve the pain of patients with early cervical spondylosis,while long-term application has certain effect on the recovery of cervical curvature.
5.Correlation between lumbar spine and pelvic parameters in Lenke type 5 adolescent idiopathic scoliosis
Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Ya LI ; Peiwu GUO ; Wenqiang YU ; Yu ZHAO ; Zanbo WANG ; Hong ZENG ; Zhenjiang MA ; Dezhi LU ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5753-5758
BACKGROUND:The study of the lumbar spine and pelvis in patients with Lenke type 5 lordosis is limited to the coronal and sagittal planes,and the three-dimensional relationship between the scoliosis and the pelvis has not yet been clarified. OBJECTIVE:To analyze the effect of lumbar scoliosis on the pelvis in patients with Lenke type 5 lordosis and to study the correlation between the lumbar spine and the three-dimensional spatial position of the pelvis. METHODS:Imaging data of 60 patients with Lenke type 5 lordosis scoliosis admitted to the 3D Printing Reception Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2019 to September 2023 were retrospectively analyzed,including Cobb angle,coronal pelvic tilt,lumbar lordosis,left and right pelvic hip width ratio(sacroiliac-anterior superior iliac spine),spinal rotation angle,pelvic tilt,sacral slope,pelvic incidence,coronal deformity angular ratio,sagittal deformity angular ratio,C7 plumb line-center sacral vertical line,apical vertebral translation,and coronal sacral inclination.The information was summarized as a database.SPSS 22.0 software was used to analyze the data related to the lumbar spine and pelvis of the patients with Lenke type 5 primary lumbar curvature adolescent idiopathic scoliosis using Spearman's correlation analysis and linear regression. RESULTS AND CONCLUSION:(1)Cobb angle was highly positively correlated with coronal deformity angular ratio,apical vertebral translation,and spinal rotation angle(r=0.91,r=0.841,r=0.736).(2)Coronal deformity angular ratio was highly positively correlated with apical vertebral translation(r=0.737),moderately positively correlated with C7 plumb line-center sacral vertical line(r=0.514),and moderately negatively correlated with sagittal deformity angular ratio(r=-0.595).(3)There was a high positive correlation between lumbar lordosis and sagittal deformity angular ratio(r=0.942)and a moderate negative correlation with coronal deformity angular ratio(r=-0.554).(4)There was a moderate positive correlation between Cobb angle with coronal pelvic tilt and coronal sacral inclination(r=0.522,r=0.534)and a moderate positive correlation between C7 plumb line-center sacral vertical line and coronal pelvic tilt(r=0.507).Apical vertebral translation with coronal pelvic tilt and coronal sacral inclination showed a moderate positive correlation(r=0.507,r=0.506).Lumbar lordosis with sacral slope and pelvic incidence showed a moderate positive correlation(r=0.512,r=0.538).Sagittal deformity angular ratio was moderately positively correlated with sacral slope and pelvic incidence(r=0.614,r=0.621).(5)Studies have found that the relative position of the lumbar spine and the pelvis is closely related in the horizontal,sagittal and coronal planes.When the lumbar spine affects scoliosis and is rotated,the relative position of the pelvis will also change to compensate,which indicates that while correcting scoliosis,the correction of the pelvis cannot be ignored.
6.Diagnosis, treatment and prevention of severe acute respiratory syndrome coronavirus 2 infection in children: experts′ consensus statement (Fifth Edition)updated for the Omicron variant
Rongmeng JIANG ; Zhengde XIE ; Yi JIANG ; Xiaoxia LU ; Runming JIN ; Yuejie ZHENG ; Yunxiao SHANG ; Baoping XU ; Zhisheng LIU ; Gen LU ; Jikui DENG ; Guanghua LIU ; Xiaochuan WANG ; Jianshe WANG ; Luzhao FENG ; Wei LIU ; Yi ZHENG ; Sainan SHU ; Min LU ; Wanjun LUO ; Miao LIU ; Yuxia CUI ; Leping YE ; Adong SHEN ; Gang LIU ; Liwei GAO ; Lijuan XIONG ; Yan BAI ; Likai LIN ; Zhuang WEI ; Fengxia XUE ; Tianyou WANG ; Dongchi ZHAO ; Zhengyan ZHAO ; Jianbo SHAO ; Wong Wing-kin GARY ; Yanxia HE ; Xingwang LI ; Yonghong YANG ; Kunling SHEN
Chinese Journal of Applied Clinical Pediatrics 2023;38(1):20-30
China has classified the Corona Virus Disease 2019(COVID-19) as a statutory category B infectious disease and managed it according to Category B since January 8, 2023.In view that Omicron variant is currently the main epidemic strain in China, in order to guide the treatment of severe acute respiratory syndrome coronavirus 2(SARS-CoV-2) infection in children with the times, refer to the Diagnosis and Treatment Protocol for Novel Coronavirus Infection (Trial 10 th Edition), Expert Consensus on Diagnosis, Treatment and Prevention of Novel Coronavirus Infection in Children (Fourth Edition) and the Diagnosis and Treatment Strategy for Pediatric Related Viral Infections.The Expert Consensus on the Diagnosis, Treatment and Prevention of Novel Coronavirus Infection in Children (Fifth Edition) has been formulated and updated accordingly on related etiology, epidemiology, pathogenic mechanism, clinical manifestations, auxiliary examination, diagnosis and treatment, and added key points for the treatment of COVID-19 related encephalopathy, fulminating myocarditis and other serious complications for clinical reference.
7.Consensus on prescription review of commonly used H 1-antihistamines in pediatrics
Lihua HU ; Lu LIU ; Huiying CHEN ; Heping CAI ; Wentong GE ; Zhiying HAN ; Huijie HUANG ; Xing JI ; Yuntao JIA ; Lingyan JIAN ; Nannan JIANG ; Zhong LI ; Li LI ; Hua LIANG ; Chuanhe LIU ; Qinghong LU ; Xu LU ; Jun′e MA ; Jing MIAO ; Yanli REN ; Yunxiao SHANG ; Kunling SHEN ; Huajun SUN ; Jinqiao SUN ; Yanyan SUN ; Jianping TANG ; Hong WANG ; Lianglu WANG ; Xiaochuan WANG ; Lei XI ; Hua XU ; Zigang XU ; Meixing YAN ; Yong YIN ; Shengnan ZHANG ; Zhongping ZHANG ; Xin ZHAO ; Deyu ZHAO ; Wei ZHOU ; Li XIANG ; Xiaoling WANG
Chinese Journal of Applied Clinical Pediatrics 2023;38(10):733-739
H 1-antihistamines are widely used in the treatment of various allergic diseases, but there are still many challenges in the safe and rational use of H 1-antihistamines in pediatrics, and there is a lack of guidance on the prescription review of H 1-antihistamines for children.In this paper, suggestions are put forward from the indications, dosage, route of administration, pathophysiological characteristics of children with individual difference and drug interactions, so as to provide reference for clinicians and pharmacists.
8.Long-term clinical value of composite biomaterial mesh in inguinal hernia repair: a multi-center prospective randomized controlled study
Yunxiao MENG ; Xianke SI ; Ding PING ; Hongbing XIAO ; Lei HUA ; Shaojie LI ; Lei HUANG ; Zhao CAI ; Shaochun LI ; Jianxiong TANG
Chinese Journal of Digestive Surgery 2023;22(9):1069-1074
Objective:To investigate the long-term clinical value of composite biomaterial mesh in inguinal hernia repair.Methods:The prospective randomized controlled non-inferiority study was conducted. The clinical data of 172 adult patients with inguinal hernia who were admitted to 3 medical centers, including Huadong Hospital Affiliated to Fudan University et al, from July 2014 to February 2015 were selected. Based on random number table, patients were divided into two groups. Patients underwent technique of abdominal wall reinforcement with biological mesh. Patients using the electrospun composite biomaterial mesh were allocated into experimental group, and patients using the small intestinal submucosa mesh were allocated into control group. Observation indicators: (1) grouping situations of the enrolled patients; (2) endpoint of the study. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the independent sample t test. Count data were described as absolute numbers or percentages, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data was conducted using the non-parameter rank sum test. Taking the recurrence rate of hernia at 6 years after surgery as the basis of efficacy evaluation, the Cochran-Mantel-Haenszel test was used for comparison between groups. The confidence interval method was used to conduct non-inferiority statistical analysis. If the lower limit of 95% confidence interval of the difference of recurrence rate of hernia between the experiment group and the control group was more than -10%, the experiment group was considered to be non-inferior to the control group. If the lower limit of 95% confidence interval is more than 0, the experiment group was considered to be superior to the control group. Results:(1) Grouping situations of the enrolled patients. A total of 172 adult patients with inguinal hernia were selected for eligibility. They were males, aged (61±2)years. All 172 patients were randomly divided into to the experimental group and the control group with 86 cases in each group. At 6 years after surgery, 20 patients in the experi-mental group and 19 patients in the control group was lost to follow-up. (2) Endpoint of the study. ① The primary endpoint of study. At 6 years after surgery, no patient had recurrence in the 66 patients of experimental group and 4 patients had recurrence in the 67 patients of control group. Results of non-inferiority statistical analysis showed that the 95% confidence interval of the difference of recurrence rate of hernia between the two groups was 0.27% to 14.41%, with the lower limit as 0.27%, which was more than -10% and simultaneously more than 0. ② The secondary endpoint of study. There was no significant difference in the simple verbal scale between the two groups after 6 months and 6 years at rest or cough status ( P>0.05). At a follow-up of 6 months after surgery, 2 cases of the experimental group and 5 patients of the control group had complications, showing no significant difference between the two groups( χ2=1.38, P>0.05). At a follow-up of 6 years after surgery, no complication occurred in either group. Conclusion:Composite biological mesh in inguinal repair is safe and feasible, which can have low long-term recurrence and achieve good long-term efficacy.
9.3D printed orthopedic insoles for flatfoot: a systematic review
Chenglan HUANG ; Yutong HOU ; Yunxiao YANG ; Hong ZENG ; Ziyan ZHANG ; Wenkuan ZHAO ; Zanbo WANG ; Chunlei SHAN ; Kerong DAI ; Bin CAI ; Jinwu WANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(4):416-422
ObjectiveTo review the classification of orthopedic insoles, common techniques of 3D printing orthopedic insoles, common materials and their application for flatfoot. MethodsLiteratures were retrieved from PubMed, Web of Science, CNKI and Wanfang Data from 2012 to 2022, and the relevant contents were summarized. ResultsA total of ten studies were finally included, from 5 countries, involving 290 participants, which published from 2019 to 2022. Orthotic insoles were classified as prefabricated, semi-custom, and custom, while custom ones were classified as traditional custom and 3D printed custom. 3D printed orthotic insoles were often made with selective laser sintering, fused deposition modeling (FDM) and PolyJet printing technologies, and commonly used materials included ethylene-vinyl acetate (EVA), polylactic acid, thermoplastic polyurethane, polyamide, and polypropylene. For flatfoot, 3D printed orthotic insoles could improve plantar pressure, relieve foot pain and the combined use of insole posting could control rearfoot valgus. Conclusion3D printed custom insoles can be made more efficiently and accurately than traditional custom insoles. The printing technologies and materials often chosen for 3D printed orthotic insoles are mainly FDM and EVA. 3D printed orthotic insoles is effective on plantar pressure, comfort and foot movement function of flatfoot.
10.Design and analysis of shoulder type exoskeleton stretcher for individual soldier.
Yunxiao MAO ; Haipo CUI ; Zhan ZHAO ; Xudong GUO ; Xin ZHANG ; Qian MA
Journal of Biomedical Engineering 2023;40(6):1200-1208
For the transportation process of rescuing wounded personnel on naval vessels, a new type of shoulder type exoskeleton stretcher for individual soldier was designed in this paper. The three-dimensional model of the shoulder type exoskeleton stretcher for individual soldier was constructed using three dimensional modeling software. Finite element analysis technique was employed to conduct statics simulation, modal analysis, and transient dynamics analysis on the designed exoskeleton stretcher. The results show that the maximum stress of the exoskeleton stretcher for walking on flat ground is 265.55 MPa, which is lower than the allowable strength of the fabrication material. Furthermore, the overall deformation of the structure is small. Modal analysis reveals that the natural frequency range of the exoskeleton stretcher under different gait conditions is 1.96 Hz to 28.70 Hz, which differs significantly from the swing frequency of 1 Hz during walking. This indicates that the designed structure can effectively avoid resonance. The transient dynamics analysis results show that the maximum deformation and stress of exoskeleton stretcher remain within the safety range, which meets the expected performance requirements. In summary, the shoulder type exoskeleton stretcher for individual soldier designed in this study can solve the problem of requiring more than 2 people to carry for the existing stretcher, especially suitable for narrow spaces of naval vessels. The research results of this paper can provide a new solution for the rescue of wounded personnel on naval vessels.
Humans
;
Stretchers
;
Military Personnel
;
Shoulder
;
Exoskeleton Device
;
Walking
;
Gait
;
Biomechanical Phenomena

Result Analysis
Print
Save
E-mail