1.Clinical application of improved treatment of the free margin of the leaflet in aortic root remodeling procedure
Xinjin LUO ; Shaoye WANG ; Juntao QIU ; Xuanshu LI ; Peng ZHANG ; Yuetang WANG ; Cuntao YU
Chinese Journal of Surgery 2025;63(7):618-623
Objective:To investigate the feasibility and clinical outcome of estimating the target length of the free margin of the leaflet by diameter of the prosthesis graft used to reconstruct the aortic root during the modified root remodeling procedure.Methods:This is a retrospective case series study. The clinical data of 11 patients with aortic root aneurysm who underwent modified aortic root remodeling procedure with external sub-valvular ring from July 2021 to May 2024 at Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College were analyzed. The age of the patients was (42.3±14.4) years (range:23 to 61 years), including 9 males and 2 females. The aortic valve of all patients was tri-leaflet configuration. Marfan syndrome was diagnosed in 3 cases. The diameter of the prosthesis graft was determined according to the Lansac group′s criteria based on the diameter of the aortic annulus, and a graft ring of the same diameter was used as the external sub-valvular ring. The free margin of the leaflet was treated with central plication according to the standard of “target length of free margin of the leaflet=the diameter of the selected graft+3 to 5 mm”. The surgical results and postoperative aortic valve closure function were observed.Results:All 11 patients successfully completed the operation without in-hospital death or complications. The graft with a diameter of 28 mm were used in 7 cases, 26 mm in 3 cases, and 30 mm in 1 case. 4 patients required central plication of the free margin of 3 leaflets, 2 patients required treatment of 2 leaflets, 3 patients required treatment of 1 leaflet, and 2 patients did not need treatment of the free margin of the leaflets. The functional status of aortic valve closure was significantly improved in all patients after surgery, and the degree of residual aortic regurgitation was not more than mild. After reconstruction of the aortic root, the measured effective height was (8.8±1.3) mm (range:7 to 11 mm) and the measured coaptation length was (5.2±0.9) mm (range:4 to 7 mm). All patients were re-examined 3 months after surgery. Echocardiography showed that the degree of aortic regurgitation was mild or lower, and the left ventricular end-diastolic diameter was (49.4±6.1) mm (range: 36 to 56 mm), which was smaller than that before the operation ((58.5±7.0) mm (range: 47 to 72 mm)). Eight patients were followed up for more than 6 months, and 5 patients were followed up for more than 1 year. The degree of aortic regurgitation in these patients was mild or below.Conclusions:The method based on the diameter of the selected prosthesis graft to deal with the length of the free margin of the leaflet can be effectively used in the modified aortic root remodeling procedure with external sub-valvular ring. The early postoperative results are satisfactory .
2.Clinical application of improved treatment of the free margin of the leaflet in aortic root remodeling procedure
Xinjin LUO ; Shaoye WANG ; Juntao QIU ; Xuanshu LI ; Peng ZHANG ; Yuetang WANG ; Cuntao YU
Chinese Journal of Surgery 2025;63(7):618-623
Objective:To investigate the feasibility and clinical outcome of estimating the target length of the free margin of the leaflet by diameter of the prosthesis graft used to reconstruct the aortic root during the modified root remodeling procedure.Methods:This is a retrospective case series study. The clinical data of 11 patients with aortic root aneurysm who underwent modified aortic root remodeling procedure with external sub-valvular ring from July 2021 to May 2024 at Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College were analyzed. The age of the patients was (42.3±14.4) years (range:23 to 61 years), including 9 males and 2 females. The aortic valve of all patients was tri-leaflet configuration. Marfan syndrome was diagnosed in 3 cases. The diameter of the prosthesis graft was determined according to the Lansac group′s criteria based on the diameter of the aortic annulus, and a graft ring of the same diameter was used as the external sub-valvular ring. The free margin of the leaflet was treated with central plication according to the standard of “target length of free margin of the leaflet=the diameter of the selected graft+3 to 5 mm”. The surgical results and postoperative aortic valve closure function were observed.Results:All 11 patients successfully completed the operation without in-hospital death or complications. The graft with a diameter of 28 mm were used in 7 cases, 26 mm in 3 cases, and 30 mm in 1 case. 4 patients required central plication of the free margin of 3 leaflets, 2 patients required treatment of 2 leaflets, 3 patients required treatment of 1 leaflet, and 2 patients did not need treatment of the free margin of the leaflets. The functional status of aortic valve closure was significantly improved in all patients after surgery, and the degree of residual aortic regurgitation was not more than mild. After reconstruction of the aortic root, the measured effective height was (8.8±1.3) mm (range:7 to 11 mm) and the measured coaptation length was (5.2±0.9) mm (range:4 to 7 mm). All patients were re-examined 3 months after surgery. Echocardiography showed that the degree of aortic regurgitation was mild or lower, and the left ventricular end-diastolic diameter was (49.4±6.1) mm (range: 36 to 56 mm), which was smaller than that before the operation ((58.5±7.0) mm (range: 47 to 72 mm)). Eight patients were followed up for more than 6 months, and 5 patients were followed up for more than 1 year. The degree of aortic regurgitation in these patients was mild or below.Conclusions:The method based on the diameter of the selected prosthesis graft to deal with the length of the free margin of the leaflet can be effectively used in the modified aortic root remodeling procedure with external sub-valvular ring. The early postoperative results are satisfactory .
3.Comparison of 1-year clinical results of transcatheter aortic valve replacement (TAVR) using prostheses with two different frame designs in 124 patients in a single center
Peide ZHANG ; Fei LI ; Xu WANG ; Donghui XU ; Yuetang WANG ; Yongjian WU ; Wei WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(08):895-900
Objective To compare and analyze the clinical effects of two kinds of frame design valves after transcatheter aortic valve replacement (TAVR). Methods We retrospectively reviewed 124 patients who underwent TAVR and were followed up for 1 year. There were 71 males and 53 females aged 75.57±6.21 years. These patients were treated with Venus-A or Edwards Sapien aortic valves. The hemodynamics and cardiac function of these two kinds of transcatheter aortic valves (THV) were evaluated by echocardiography. The 30-day mortality and 1-year clinical effect of the patients were calculated. Results Eight-one patients used Venus-A valve and 43 patients used Edwards Sapien valve. The aortic valve transaortic pressure gradient was reduced and the rate of perivalvular leakage was low (both 2.6%) in both groups, and there was no statistical difference between the two groups. The implantation rate of permanent pacemaker was 17.3% and 11.6%, respectively. The 1-month survival (94.0% and 93.0%) and 1-year survival (94.0% and 91.0%) rates were not statistically different. Conclusion The two groups of THV with different stent structures have good short-term clinical effect and low implantation rate of permanent pacemaker.
4.Outcomes and preoperative evaluation of transfemoral transcatheter aortic valve replacement (TAVR) in the treatment of pure native aortic valve regurgitation
Donghui XU ; Xinjin LUO ; Xu WANG ; Yuetang WANG ; Xiang FENG ; Xuanshu LI ; Juntao QIU ; Wei WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(09):1054-1060
Objective To assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation. Methods A total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients). Results The incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group. Conclusion Transfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.
5. Application of the descending branch of the lateral circumflex femoral artery in the coronary artery bypass grafting operation
Xinjin LUO ; Wei WANG ; Yuetang WANG ; Yang YANG ; Han LI ; Xu WANG ; Shengshou HU
Chinese Journal of Surgery 2017;55(11):834-837
Objective:
To investigate the technical method for harvesting and application of the descending branch of the lateral circumflex femoral artery (DBLCFA) in the coronary artery bypass grafting (CABG) operation.
Methods:
Between December 2016 and April 2017, 19 patients were arranged to use DBLCFA and got CT angiography (CTA) of pelvic and femoral arteries pre-operative at Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College. Finally, DBLCFA was harvested in 16 patients (including 2 female patients, with a mean age of (47.4±8.5) years) through the anterior thigh incision (13 cases on the left side, 3 cases on the right side). The CABG operations were performed under the cardiopulmonary bypass support (in 10 cases) or under the beating heart condition (in 6 cases), and the DBLCFA conduit was used combining with bilateral internal thoracic artery (in 12 cases), radial artery (in 7 cases) and saphenpous vein (in 3 cases).
Results:
Due to anatomical variations such as short length and anomalous branch, or due to silent atherosclerosis stenosis of femoral artery, DBLCFA in 3 patients was considered inappropriate for use and was not harvested after CTA examination. In another 16 patients, DBLCFA was safely and quickly harvested and successfully used. On average, 3.4±0.6 anastomosis was built up in CBAG, no adverse effects were exhibited. The length of the harvested DBLCFA was (10.3±1.8) cm, with average lumen diameter of (1.9±0.5) mm. DBLCFA was used as free graft in 15 patients (7 to the first diagonal branch, 6 to the ramus intermedius branch, 1 to the left anterior descending branch and 1 to the second obtuse marginal branch). In 1 patient, the DBLCFA was firstly implanted end-to-side to the internal thoracic artery as a "Y" type composite graft, and then anastomosed to the third obtuse marginal branch.
Conclusions
The descending branch of the lateral circumflex femoral artery is an option conduit in CABG. It can be harvested easily and safely. However, pre-operative CTA examination is necessary to exclude the variation and appropriate strategy for graft establishment should be considered during the operation.
6.Short-term Effect and Risk Factor Analysis on the Timing of Intra-aortic Balloon Pump Implantation for Coronary Artery Bypass Grafting in Patients With High Risk Coronary Artery Disease
Yuetang WANG ; Juntao QIU ; Xu WANG ; Jing ZHANG ; Zujun CHEN ; Xianqiang WANG ; Wei WANG
Chinese Circulation Journal 2017;32(3):232-236
Objective: To evaluate short-term effect and risk factors for the timing of intra-aortic balloon pump (IABP) implantation with coronary artery bypass grafting (CABG) in high risk coronary artery disease (CAD) patients. Methods: A total of 197 high risk CAD patients received IABP with CABG in our hospital from 2010-01 to 2015-12 were retrospectively analyzed. There were 91 (46.2%) male and the mean arterial pressure (MAP) was (70.3±8.2) mmHg. Based on IABP implantation time, the patients were divided into 2groups: Pre-operative IABP group,n=89 and Intra- , post-operative IABP group,n=108. Peri-operative condition, durations of mechanical ventilation and ICU stay were compared between 2 groups; survival condition was studied by Kaplan-Meier analysis; risk factors causing 30-day mortality was assessed by Logistic regression analysis and its sensitivity and specialty was measured by ROC curve. Results: The mean durations for aortic clamping and cardiopulmonary bypass were (86.7±37.3) min and (147.3±18.4) min in all 197 patients. The age, gender, blood levels of CK-MB c-TnI, creatinine, MAP and European cardiac surgery system scoring were similar between 2 groups, allP>0.05. Compared with Intra- , post-operative IABP group, Pre-operative IABP group had decreased CK-MB (130.6±25.4) mmol/L vs (149.7±18.2) mmol/L at 48h post-operation and mechanical ventilation time (81.5±10.3) h vs (107.9±11.5) h, less in-hospital stay (21.3±4.1) d vs (27.7±9.4) d, reduced acute kidney injury (3.4% vs 23.1%), brain complication (5.6% vs 19.4%) and 30-day mortality (4.5% vs 36.1%), allP<0.05. Kaplan-Meier analysis indicated that the median survival time was longer in Pre-operative IABP group, (27.9±1.2 vs 16.5±2.2) dP<0.05; Logistic regression analysis and ROC curve demonstrated that IABP re-implantation (OR=2.37, 95% CI 1.42-5.72,P=0.01) was an important risk factor for 30-day mortality with the sensitivity of 75.3% and specialty of 67.4%. Conclusion: Pre-operative IABP implantation was helpful for decreasing post-operative level of CK-MB, reducing mechanical ventilation, in-hospital time and short-term mortality in high risk CAD patients; IABP re-implantation was the risk factor for short-term mortality.