1.Clinical evaluation of anlotinib in third-line treatment for advanced non-small cell lung cancer based on real-world data
Jian WU ; Peipei LI ; Yongfu ZHU ; Dongwei ZHANG ; Yongzhong WANG ; Hao CHEN
China Pharmacy 2025;36(12):1488-1494
OBJECTIVE To evaluate the clinical value of anlotinib in third-line treatment for patients with advanced non-small cell lung cancer (NSCLC) through real-world data. METHODS Clinical data of patients with advanced NSCLC who received treatment at the First Affiliated Hospital of Anhui University of Chinese Medicine from February 2021 to December 2024 were retrospectively collected. They were divided into anlotinib group (27 cases, receiving anlotinib therapy) and immunotherapy group (22 cases, receiving immunotherapy agents alone or in combination with chemotherapy drugs) according to treatment regimens. The progression-free survival (PFS) and overall survival (OS) of patients were compared between the two groups, and the occurrence of adverse drug reactions during the treatment period was recorded. Using a partitioned survival model, an economic evaluation of the two treatment regimens was conducted with a cost-utility analysis approach from the perspective of the healthcare system. RESULTS The median PFS and OS of patients in the anlotinib group were 5.93 months and 11.27 months, respectively; the median PFS and OS of patients in the immunotherapy group were 5.33 months and 9.77 months, respectively; the difference was not statistically significant (P>0.05). There was no statistical difference in the total incidence of adverse drug reactions and grade 3-4 serious adverse drug reactions between the two groups (P>0.05). Compared with the immunotherapy group, the incremental cost-effectiveness ratio of the anlotinib group was 1 806 724.60 yuan/quality-adjusted life year (QALY), which was significantly higher than three times China’s per capita gross domestic product in 2024 (287 247 yuan/QALY). CONCLUSIONS For third-line treatment of advanced NSCLC patients, the efficacy of anlotinib is no worse than that of immunotherapy alone or in combination with chemotherapy drugs, and the safety of the two groups is comparable. However, anlotinib is not cost-effective.
2.Construction and effectiveness analysis of working model of cough and asthma pharmaceutical care clinic
Xiang LI ; Ying LI ; Yongzhong WANG ; Lunzhu XIA
China Pharmacy 2025;36(15):1910-1914
OBJECTIVE To establish a working model for the cough and asthma pharmaceutical care clinic and analyze the effects of outpatient pharmaceutical care interventions on patients. METHODS A pharmaceutical care clinic for cough and asthma was established in our hospital, with comprehensive regulations and rules, complete infrastructure and defined pharmaceutical care workflows. The demographic data of patients (gender, age, residence, disease duration and so on) were collected from May 2021 to December 2024. Indicators including health status, disease severity, inhalation technique, and medication adherence during visits and follow-up were collected and analyzed statistically, to assess the effects of pharmaceutical care interventions on patients. RESULTS The service procedure for the cough and asthma pharmaceutical care clinic in our hospital was established. A total of 215 patients’ basic information was collected. It was found that among the patients, males accounted for 55.35%, with an average age of (60.91±15.75) years old. Patients aged 60 to 69 constituted the largest proportion at 28.37%, and they exhibited relatively poor medication adherence [with an average score of (5.64±1.76)]. The majority of patients were diagnosed with chronic obstructive pulmonary disease (COPD) and prescribed budesonide/formoterol powder inhalers. In 68 follow-up cases, EQ-5D-5L scores increased by 5.81 points (P<0.05); COPD Assessment Test (CAT) scores decreased by 4.05 points (P<0.05), indicating reduced disease burden. Asthma Control Test (ACT) scores improved by 4.80 points, reaching partial control levels. Inhaler technique scores increased by 2.31 points (P<0.05). Medication adherence scores rose by 1.09 points (P<0.05). Patient satisfaction was over 90%. CONCLUSIONS After pharmaceutical care intervention, patients’ health status, disease severity, inhalant use technique, and compliance have all improved, and their satisfaction with the cough and asthma pharmaceutical care outpatient service is high. The pharmaceutical care intervention provided by the cough and asthma pharmaceutical care outpatient service can improve patients’ disease symptoms and medication compliance, and enhance the level of safe and rational drug use in the hospital.
3.Assessment of the implementation of Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015)
Yuze YANG ; Hongfang WANG ; Haoxian YANG ; Quan WU ; Mingsheng LI ; Bala HARI ; Yongzhong MA ; Zechen FENG ; Bin BAI ; Jie GAO ; Wei ZHOU ; Weixu HUANG ; Zhengjie SHI ; Hezheng ZHAI
Chinese Journal of Radiological Health 2025;34(5):660-665
Objective To track and evaluate the implementation and application of the occupational health standard Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015) by radiation health technical service agencies, medical institutions, health supervision agencies, and radiotherapy facility design units, and to provide a scientific basis for the further revision and implementation of this standard. Methods Following the Guideline for health standards tracking evaluation (WS/T 536-2017) and the project implementation plan, relevant practitioners were randomly selected for a questionnaire survey. The survey primarily focused on their awareness, standard training, application, and revision suggestions of GBZ/T 201.4-2015. The results were summarized and analyzed. Results A total of 168 evaluation questionnaires were collected from relevant practitioners in 28 provinces. Only 31.6% of the respondents reported being “well familiar” or “ familiar” with the standard, 27.4% of the respondents believed that the standard was widely used, and 45.2% of the respondents believed that the standard could meet the needs of their work. Only 14.9% of the respondents had received relevant training on the standard, more than half of the respondents had not applied the standard within the past 10 years, and 45.2% of the respondents believed that the standard "needs to be revised". Conclusion Due to the small number of californium-252 neutron afterloading radiotherapy devices in operation on the market, the overall awareness of the standard is low, suggesting that relevant authorities need to strengthen training and publicity of the standard, and that certain sections of the standard need to be revised or merged.
4.Determination of radionuclide levels in food and assessment of effective dose in Beijing, China
Huan WANG ; Yaru SUN ; Meinan YAO ; Yongzhong MA ; Shuchang YAN ; Hui ZHANG ; Zhen WU ; Bin BAI
Chinese Journal of Radiological Health 2025;34(5):733-739
Objective To investigate the levels of radionuclides in food in Beijing, China, and assess the committed effective dose to local residents from food intake. Methods From 2021 to 2022, a total of 65 food samples across 7 categories were collected in Beijing. The activity concentrations of radionuclides, including 137Cs, 210Pb, 238U, 228Ra, 226Ra, 40K, 90Sr, 210Po, 3H and 14C, were measured using gamma spectrometry and radiochemical methods. By combining the monitoring results with dietary consumption data of Beijing residents and the internal dose coefficients for Chinese reference adult phantom, the committed effective dose was estimated. Results The levels of radionuclides in food in Beijing were within the normal background range, consistent with related surveys in China and abroad, with activity concentrations below national standard limits. No significant differences were found in the activity concentrations of 137Cs, 238U, 228Ra, 226Ra and 40K between food samples collected from key areas and those from control areas (P > 0.05). The committed effective doses calculated according to internal dose coefficients for Chinese reference adult male phantom and GB 18871-2002 were 0.26 mSv and 0.19 mSv, respectively. Based on the Chinese reference adult male phantom, the majority of the committed effective dose was attributed to 210Pb (45.1%), 228Ra (37.1%), 210Po (12.3%), and 226Ra (4.7%). Conclusion The levels of radionuclides in food in Beijing fluctuated within the background range, resulting in a low radiation dose burden to the population.
5.Accuracy Assessment of Cone-Beam CT Images for Pelvic Tumor Dose Calculation.
Bao LI ; Yongzhong CHEN ; Jun JIN ; Longjun YAN ; Xiaoyong WANG
Chinese Journal of Medical Instrumentation 2025;49(3):302-307
OBJECTIVE:
To evaluate the feasibility and accuracy of cone-beam CT (CBCT) images for radiotherapy dose calculation in pelvic tumors.
METHODS:
An improved volumetric density coverage method was used to establish CT value-relative electron density (RED) curves for CBCT images. The planning CT plans were transferred to the CBCT images, and the constructed density curves were applied to calculate doses for CBCT plans while maintaining the optimization parameters unchanged. Dose calculation deviations between the two plans were analyzed.
RESULTS:
The mean differences in dosimetric parameters for the target volume and organs at risk (OAR) between the two plans were less than 1% and 1.5%, respectively. The target conformity index (CI), homogeneity index (HI), and gamma passing rates were highly consistent, with no statistically significant differences.
CONCLUSION
CBCT images corrected by this method can be used for dose calculation in pelvic tumor radiotherapy planning.
Cone-Beam Computed Tomography/methods*
;
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy Dosage
;
Pelvic Neoplasms/diagnostic imaging*
6.Analysis of uranium concentration in surface water and drinking water in Beijing, China
Huan WANG ; Yaru SUN ; Meinan YAO ; Bin BAI ; Qinghua MENG ; Yongzhong MA
Chinese Journal of Radiological Health 2024;33(1):51-55
Objective To explore the uranium concentration in surface water and drinking water in Beijing, China and the relationship between uranium concentration and gross α activity concentration. Methods Water samples were collected from 16 districts in Beijing. Uranium concentration and gross α activity concentration were measured with WGJ-III trace uranium analyzer and LB6008 six-channel α/β counter using the ultraviolet fluorescence and thick source methods. Results The uranium concentrations in surface water and drinking water were 1.131 and 1.572 μg/L, respectively. The gross α activity concentrations in surface water and drinking water were 0.059 and 0.074 Bq/L, respectively. There were no significant differences in uranium concentration and gross α activity concentration between surface water and drinking water (P > 0.05). The uranium concentration was positively correlated with the gross α activity concentration, with a correlation coefficient of 0.700 (P < 0.05). The gross α activity concentration was determined by the uranium concentration with a determination coefficient of 48%. The committed effective dose of 238U in drinking water was between 3.284 × 10−5 and 1.640 × 10−3 mSv, with an average value of 5.400 × 10−4 mSv. Conclusion The uranium concentration and gross α activity in the surface water and drinking water in Beijing fluctuate and remain in the background range. These values are much lower than the recommended limits of 0.03 mg/L and 0.5 Bq/L stipulated in the GB 5749-2021 Standard for Drinking Water Quality. The annual committed effective dose of 238U through drinking water ingestion is very small.
7.Effects of 241Am standard material powder with different matrices on the determination of gross alpha activity in water
Yaru SUN ; Fuyou FAN ; Huan WANG ; Meinan YAO ; Bin BAI ; Yongzhong MA
Chinese Journal of Radiological Health 2024;33(3):278-282
Objective To understand the effects of 241Am standard material powder with different matrices on the determination of gross alpha activity in water, and to provide a reference for the selection and use of alpha standard sources. Methods The alpha counting efficiency of 241Am standard material powder with different matrices was measured by low-background alpha and beta measuring instrument. The radiochemical recovery rate and whole process efficiency of gross alpha activity in water were determined by spike experiments. Results The alpha counting efficiency of the 241Am standard material powder with four matrices was in the descending order of calcium carbonate, calcium carbonate and silica mixed matrix, calcium sulfate, and silica. The default chemical recovery rate is 1 when gross alpha activity in water is measured by thick source method. The use of 241Am standard material with calcium carbonate as a matrix resulted in about 35% decrease in gross alpha activity, and about 10% deviation was observed using 241Am standard material with silica or calcium carbonate and silica mixed matrices. The whole process efficiency of alpha activity in four spiked water samples with 241Am standard solution and 241Am standard material powder with calcium carbonate, silica, or mixed matrix was 6.34%-7.30%. Conclusion Standard materials with different matrices demonstrate different self-absorption of alpha particles and various influence on the chemical recovery. When purchasing and using standard material powders for alpha activity measurement in laboratories, the composition of the matrix should be clarified as much as possible, and the gross alpha activity in water should be determined by measuring the whole process efficiency if necessary.
8.Determination of carbon-14 in seafood by tube furnace oxidation combustion and liquid scintillation counting method
Yaru SUN ; Huan WANG ; Meinan YAO ; Yongzhong MA ; Bin BAI
Chinese Journal of Radiological Health 2024;33(4):370-375
Objective To investigate the method of tube furnace oxidation combustion and liquid scintillation counting for the determination of carbon-14 in seafood, and to provide technical support for the monitoring of carbon-14 in seafood. Methods By studying the pyrolysis characteristics of five types of dried seafood samples, including yellow croaker, white shrimp, swimming crab, clam, and seaweed, a temperature control program suitable for the oxidation combustion of seafood was established. The combustion efficiency, carbon element recovery rate, and the accuracy and precision of the method were determined. Results The combustion efficiency was more than 98% for most seafood using the recommended combustion program. The recovery rate of carbon was similar to that calculated by glucose combustion; both were more than 95%. Four laboratories validated the accuracy of the method by measuring the carbon-14 activity concentration in the Chinese sugar carbon standard material. The relative errors ranged from 1.03% to 3.41% and the average relative error was 2.36%. The precision of this method was verified by measuring the carbon-14 activity concentration in yellow croaker samples. The within-laboratory relative standard deviation ranged from 5.11% to 9.35% and the between-laboratories relative standard deviation was 4.04%. Conclusion The tube furnace oxidation combustion and liquid scintillation counting method was used to determine the activity concentration of carbon-14 in seafood. The recommended oxidation combustion program is more targeted and less time-consuming. The accuracy and precision of this method meet the requirements. This method is suitable for the determination of carbon-14 in seafood.
9.Current status of quality control of kV X-ray radiotherapy equipment
Zechen FENG ; Zihan WANG ; Yongzhong MA ; Hui XU ; Qiao MA ; Hailiang LI
Chinese Journal of Radiological Health 2024;33(4):466-471
kV X-ray radiotherapy was the primary mode of radiotherapy widely used to treat many types of cancer, including deep tumors, before the invention of the Co-60 therapy machine and the electron linear accelerator, which gradually replaced kV X-ray radiotherapy. kV X-ray radiotherapy equipment requires less space and shielding, and still has application value in the treatment of skin lesions and superficial tumors. Especially in recent years, kV X-ray has been used in the treatment of keloid, and electronic brachytherapy equipment has been used in intracavitary, intraoperative, and superficial radiotherapy. Therefore, kV X-ray radiotherapy has seen renewed application. The quality control of kV X-ray radiotherapy equipment is the key to ensure the treatment effect and safety of patients. This paper reviews the current status of quality control of kV X-ray radiotherapy equipment and provides a reference for the formulation of quality control assessment standards for kV X-ray radiotherapy equipment.
10.Variation of 137Cs activity concentration in aerosol in Beijing
Huan WANG ; Qinghua MENG ; Yun LOU ; Bin BAI ; Weijie ZHU ; Hongfang WANG ; Yuxia KONG ; Zechen FENG ; Shuguang ZHAI ; Jun YU ; Yaru SUN ; Yongzhong MA
Journal of Environmental and Occupational Medicine 2024;41(9):1038-1042
Background 137Cs in atmospheric aerosol is the product of past nuclear weapon tests and nuclear accidents. When 137Cs is released into the atmosphere, it will deposit in dry land and marine environment, causing pollution of soil surface, water, agricultural products, and animal byproducts, and affecting public health. Objective To identify the variation pattern of 137Cs activity concentration in aerosol and its correlation with dust concentration in Beijing area from 2017 to 2020. Methods A total of 958 aerosol samples were collected from November 1, 2017 to June 30, 2020 in Beijing with a high volume air sampler at a sampling flow rate about 600 m3·h−1 and a collection time for each sample about 24 h. The activity concentration of 137Cs in the aerosol samples was determined with a low-background high-purity germanium γ spectrometer. The dust concentration was calculated using the difference in the mass of the aerosol filter before and after sampling. The detection rate of 137Cs and dust concentration in different seasons were compared. Spearman rank correlation test was used to analyze the correlation between 137Cs activity concentration and dust concentration. Results From 2017 to 2020, the 137Cs activity concentrations of 33 from 958 aerosol samples in Beijing were above the minimum detectable activityconcentration, the overall detection rate of 137Cs was 3.4%, and the activity concentration ranged from 1.86 to 45.53 μBq·m−3, with a median value of 4.85 μBq·m−3. The detection rate of 137Cs was highest in spring, followed by autumn, and lowest in winter and summer (8.4%, 3.0%, 1.1%, and 0.5%, respectively). The dust concentration ranged from 0.03 to 1.55 mg·m−3, with an average value of 0.18 mg·m−3. There was a statistically significant difference in the dust concentrations in spring, summer, autumn, and winter (F=45.51, P<0.05), and the highest value was 0.24 mg·m−3 in spring (P<0.05). The 137Cs activity concentration was positively correlated with the dust concentration (P<0.05). Conclusion The 137Cs activity concentration in aerosol in Beijing from 2017 to 2020 fluctuates within the range of background level, and its activity concentration is highest in spring, followed autumn, and lowest in summer and winter.

Result Analysis
Print
Save
E-mail