1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Research on the construction and application of blood standard system in China
Jin GUO ; Hongjie WANG ; Xin SHI ; Yong WANG
Chinese Journal of Blood Transfusion 2026;39(4):564-570
Blood standardization is a crucial means of promoting the healthy and sustainable development of China's blood industry. The construction of a blood standard system serves as the foundational work for blood standardization. To facilitate the continuous improvement of blood standardization efforts, this paper begins by describing the current status and analyzing the issues within China's blood standard system. Through systematic research, it proposes a framework for constructing a blood standard system and offers revision recommendations for its enhancement. Based on the first five editions of the blood standard system developed by Sub-Committee of Blood Standards of National Committee of Health Standards, this study further refines the revision and detailed construction of the standards framework—the primary task in establishing the blood standard system. It provides specific guidance for both the construction and application of the blood standard system. This work serves as a reference and basis for the reasonable and standardized formulation and revision of blood standards, as well as for the management and implementation of blood standardization efforts.
3.Two-dimensional black phosphorus materials for bone tissue engineering
Jiahan CHEN ; Chao FENG ; Xiaoxia HUANG ; Minghui NIU ; Xin WANG ; Yong TENG
Chinese Journal of Tissue Engineering Research 2025;29(10):2124-2131
BACKGROUND:Black phosphorus has a high degree of homology with human bone,so it has been extensively studied in the field of bone tissue engineering in recent years.Since 2014,two-dimensional black phosphorus materials have garned significant attention in the field of biomedicine due to their excellent exceptional physical,chemical,and biological properties. OBJECTIVE:To summarize the advancements made in black phosphorus-based nanomaterials for bone tissue engineering,focus on the synthesis methods,osteogenic characteristics,and applications in biomaterials pertaining to two-dimensional black phosphorus nanomaterials. METHODS:Chinese and English key words were"black phosphorus,bone tissue engineering,bone defect,bone regeneration,osteogenesis."Relevant articles in PubMed and CNKI databases from January 2014 to December 2023 were searched.After exclusion and screening,96 articles were analyzed. RESULTS AND CONCLUSION:Black phosphorus nanomaterials play an important role in bone tissue engineering due to their good biocompatibility,biodegradability,photothermal action,antibacterial ability,drug loading performance,and special osteogenic effect,and are ideal candidate materials for promoting bone regeneration.The preparation of black phosphorus nanomaterials is mainly a top-down top-layer stripping method.The main principle is to weaken the van der Waals force between the black phosphorus layers by physical or chemical means to obtain a single or less layer of phosphanse,that is,black phosphorus nanosheets or quantum dots.Black phosphate-based nanocomposites are mainly divided into hydrogels,3D printing scaffolds,composite scaffolds,electrospinning,bionic periosteum,microspheres,and bionic coatings.The research of nano-black phosphorus in bone tissue engineering is in its infancy,and still faces many challenges:the behavior of black phosphorus in vivo and the interaction mechanism with various biomolecules need to be further studied.The long-term potential toxicity of black phosphorus is unknown.The manufacturing process for black phosphorus is difficult to control.Therefore,how to develop uniform size,safe,reliable,and efficient nano black phosphorus and transform it into clinical application requires interdisciplinary research on modern biomedical technology,physicochemical technology,and precision manufacturing technology.
4.Controllability Analysis of Structural Brain Networks in Young Smokers
Jing-Jing DING ; Fang DONG ; Hong-De WANG ; Kai YUAN ; Yong-Xin CHENG ; Juan WANG ; Yu-Xin MA ; Ting XUE ; Da-Hua YU
Progress in Biochemistry and Biophysics 2025;52(1):182-193
ObjectiveThe controllability changes of structural brain network were explored based on the control and brain network theory in young smokers, this may reveal that the controllability indicators can serve as a powerful factor to predict the sleep status in young smokers. MethodsFifty young smokers and 51 healthy controls from Inner Mongolia University of Science and Technology were enrolled. Diffusion tensor imaging (DTI) was used to construct structural brain network based on fractional anisotropy (FA) weight matrix. According to the control and brain network theory, the average controllability and the modal controllability were calculated. Two-sample t-test was used to compare the differences between the groups and Pearson correlation analysis to examine the correlation between significant average controllability and modal controllability with Fagerström Test of Nicotine Dependence (FTND) in young smokers. The nodes with the controllability score in the top 10% were selected as the super-controllers. Finally, we used BP neural network to predict the Pittsburgh Sleep Quality Index (PSQI) in young smokers. ResultsThe average controllability of dorsolateral superior frontal gyrus, supplementary motor area, lenticular nucleus putamen, and lenticular nucleus pallidum, and the modal controllability of orbital inferior frontal gyrus, supplementary motor area, gyrus rectus, and posterior cingulate gyrus in the young smokers’ group, were all significantly different from those of the healthy controls group (P<0.05). The average controllability of the right supplementary motor area (SMA.R) in the young smokers group was positively correlated with FTND (r=0.393 0, P=0.004 8), while modal controllability was negatively correlated with FTND (r=-0.330 1, P=0.019 2). ConclusionThe controllability of structural brain network in young smokers is abnormal. which may serve as an indicator to predict sleep condition. It may provide the imaging evidence for evaluating the cognitive function impairment in young smokers.
5.Simultaneous TAVI and McKeown for esophageal cancer with severe aortic regurgitation: A case report
Liang CHENG ; Lulu LIU ; Xin XIAO ; Lin LIN ; Mei YANG ; Jingxiu FAN ; Hai YU ; Longqi CHEN ; Yingqiang GUO ; Yong YUAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):277-280
A 71-year-old male presented with esophageal cancer and severe aortic valve regurgitation. Treatment strategies for such patients are controversial. Considering the risks of cardiopulmonary bypass and potential esophageal cancer metastasis, we successfully performed transcatheter aortic valve implantation and minimally invasive three-incision thoracolaparoscopy combined with radical resection of esophageal cancer (McKeown) simultaneously in the elderly patient who did not require neoadjuvant treatment. This dual minimally invasive procedure took 6 hours and the patient recovered smoothly without any surgical complications.
6.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
7.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
8.Application of Auto-Prescription Technique in CT Portal Venography and Liver Volume Measurement
Yong FAN ; Xin FANG ; Yijun LIU ; Beibei LI ; Shigeng WANG ; Anliang CHEN
Chinese Journal of Medical Imaging 2025;33(9):1009-1014
Purpose To explore the application value of auto-prescription technique in CT portal venography and liver volume measurement.Materials and Methods A total of 180 patients who underwent contrast-enhanced abdominal CT in the First Affiliated Hospital of Dalian Medical University from April to November 2022 were prospectively collected and randomly divided into two groups,with 90 cases in each group.Group A(experimental group)was scanned with auto-prescription technique.Group B(conventional group)was scanned with 120 kVp,and the other imaging parameters kept the same as group A.In group A,the correlation between body mass index and tube voltage(kVp)recommended by auto-prescription technique was analyzed.The following values were compared between group A and group B,including the volume CT dose index,dose length product,CT value of portal vein and liver,standard deviation,contrast-to-noise ratio(CNR),image quality and subjective score of automatic segmentation.The liver volumes of group A and B were measured by Liver Segmentation software.The volumes measured by automatic segmentation software(Vsoft)were recorded,and then were compared with those segmented manually(gold standard)(Vstnd).Results Compared with group B,the volume CT dose index and dose length product in group A decreased by 22%and 25%(t=-4.654,-5.403,both P<0.05),respectively.The CT value and CNR of portal vein and liver in group A were higher than those in group B(t=4.857-6.011,all P<0.05).There was no significant difference in standard deviation,Vstnd and Vsoft between group A and group B(P>0.05).The consistency of subjective scores between the two observers was good(ICC=0.773-0.856,all P<0.05).The subjective scores of two-dimensional and three-dimensional images,as well as the automatic software segmentation scores in group A were higher than those in group B(Z=897.500,1 287.500,912.721,all P<0.05).The recommended kVp value in group A was positively correlated with body mass index(r=0.674,P<0.001).Conclusion The application of auto-prescription technique in CT portal venography can ensure the image quality,measure the liver volume accurately,and reduce the patient's radiation dose individually.
9.RICH1 regulates myocardial fibrosis through TGF-β/SMAD signaling pathway
Lu-xuan WAN ; Ying-qing HU ; Yuan-yuan LIU ; Yong-song TANG ; Jun-yi HUANG ; Zi-xuan ZHANG ; Xiao-xiao MAO ; Xin-wen NIE ; Zhan-hong REN
Chinese Pharmacological Bulletin 2025;41(11):2089-2096
Aim To reveal the mechanism of CIP4 homologs protein 1(RICH1)are involved in the regu-lation of myocardial fibrosis.Methods Mouse cardiac fibroblasts(MCFs)cells were treated with transforming growth factor-β(TGF-β1)to induce the formation of a myocardial fibrosis cell model;the level of the target protein was detected by Western blotting;and the RICH1 gene was detected by transfection of the cells with plasmid.The RICH1 gene was overexpressed(RICH 1 OE)using plasmid transfection;the RICH1 gene was silenced using siRNA fragment(siRICH1);and the expression levels of myocardial fibrosis marker genes,such as Col1 a1,Col3 a1,and Acta2,were de-tected using RT-qPCR.Results RICH1 was signifi-cantly down-regulated in TGF-β1-treated MCFs;the expression levels of myocardial fibrosis marker genes,such as Col1 a1,Col3a1,and Acta2,were down-regu-lated in the RICH1 OE+TGF-β1 group;and in the siRICH1+TGF-β1 group,myocardial fibrosis marker genes,such as Col1 a1,Col3a1 and Acta2 were up-regulated at the expression level;phosphorylated SMAD2(p-SMAD2)and phosphorylated SMAD3(p-SMAD3)levels were down-regulated in the siRICH1 OE+TGF-β1 group.p-SMAD2 and P-SMAD3 levels were upregulated in the siRICH1+TGF-β1 group.Conclusion RICH1 inhibits TGF-β1-induced myo-cardial fibrosis;RICH1 inhibits TGF-β1-induced myo-cardial fibrosis by negatively regulating the SMAD2/3 signaling pathway.
10.The lnfluencing Factors of Pregnancy Outcome of Postoperative Endometriosis Combined Drug Therapy Based on Machine Learning
Xin WANG ; Yong LIU ; Ruihua ZHAO
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(3):894-900
Objective To predict the pregnancy probability of patients and provide clinical guidance,the factors that affect the pregnancy outcome of patients with endometriosis(EM)after operation by machine learning were explored.Methods The clinical data of 167 EM patients after conservative surgery were analyzed retrospectively.Boruta algorithm was used to screen the features with high ranking,and four machine learning models,namely random forest,decision tree,support vector machine(SVM)classifier and extreme gradient lifting(XGBoost)were constructed.The performance of the model is evaluated based on four indicators:accuracy,recall,accuracy and area under curve(AUC)of receiver operating characteristic.Shapley additive interpretation(SHAP)was used to visualize the contribution of each variable to the pregnancy outcome and the positive and negative directions.Results Age,body mass index(BMI),postoperative CA125,preoperative CA125,the course of opportune capsule,the course of dysmenorrhea,the score of dysmenorrhea symptoms,the score of pelvic positive signs,the score of TCM symptoms and menstrual cycle were the important characteristics in the top ranking.The decision tree model(accuracy:0.66,accuracy:0.63,recall:0.62,AUC:0.67,F1:0.60)had the best average classification performance.Based on the results of SHAP analysis,age,BMI index,postoperative CA125 level and Traditional Chinese medicine syndrome score had significant effects on the outcome.The higher the value,the lower the postoperative pregnancy rate.Conclusion Age,BMI,postoperative CA125 level and traditional Chinese medicine syndrome score of patients with endometriosis after combined drug therapy are the main evaluation indexes that affect the pregnancy outcome of patients with endometriosis after combined drug therapy.When the values of these four characteristics are high,patients are not advised to conceive naturally,and appropriate assisted reproductive technology should be selected as soon as possible.

Result Analysis