1.Simultaneous Determination of Four Off-flavors in Freshwater Fish by Gas Chromatography-Mass Spectrometry Combined with Silica Solid Phase Extraction
Liang-Liang TIAN ; Dong-Mei HUANG ; Yuan WANG ; Xuan-Yun HUANG ; Yong-Fu SHI ; Hong-Li YE
Chinese Journal of Analytical Chemistry 2025;53(7):1158-1166
An effective method for simultaneously detecting four semivolatile earthy-musty odors in freshwater fish by gas chromatography-mass spectrometry(GC-MS)was developed.The concurrent extraction of geosmin(GSM),2-methylisoborneol(MIB),2-isopropyl-3-methoxypyrazine(IPMP),and 2-isobutyl-3-methoxypyrazine(IBMP)in fish tissue was conducted with n-hexane.The optimized QuEChERS material was implemented,and it was found that C18,primary secondary amine(PSA)and MgSO4 could adsorb the target analytes in n-hexane.So only the graphitized carbon black(GCB)could be used to purify the extraction.The adsorption rates of different materials for the four kinds of odors materials were explored in n-hexane and ethyl acetate.The experimental results revealed that the adsorption rates of silica for the four targets were 99.5%-100%in n-hexane and 0.7%-5.0%in ethyl acetate respectively.Then the silica solid phase extraction(SPE)method was utilized to eluent the compounds using 1.0 mL n-hexane/ethyl acetate in different proportions.The results of the comparative analysis demonstrated that n-hexane/ethyl acetate(4∶1,V/V)was the optimized eluent.Based on the obtained results,n-hexane extraction and GCB purification combined with silica SPE were used to isolate GSM,MIB,IPMP and IBMP from fish and the method was validated.It was found that the method showed good linearity in the range of 0.5-200 ng/mL,and with detection limits of 0.6 μg/kg for GSM and MIB,0.2 μg/kg for IPMP and IBMP.The limits of quantitation(LOQ)were 1.0 μg/kg for GSM and MIB,0.6 μg/kg for IPMP and IBMP.Good recoveries(77.5%-112.0%)and relative standard deviations(1.56%-9.42%)were also obtained.The use of silica SPE greatly mitigated the issue that the off-flavor compounds were easily lost in the gas blowing concentration process.There was no cross contamination in this method because the sample pretreatments were conducted separately,which was different with the most commonly used HS-SPME method for detecting semi-volatile substances.The sensitivity of this method was high enough to produce good quantitative results below the odor thresholds of the examined off-flavor compounds.
2.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
4.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
5.Comparison of side-opening and front-opening approach bone cement injectors in percutaneous kyphoplasty for thoracolumbar osteoporotic vertebral compression fractures.
Wei-Xin DONG ; Zhen-Tao CHU ; Yong HU ; Ou-Jie LAI ; Zhen-Shan YUAN ; Xiao-Yang SUN
China Journal of Orthopaedics and Traumatology 2025;38(2):128-133
OBJECTIVE:
To compare clinical efficacy between side-opening and front-opening bone cement injectors in percutaneous kyphoplasty(PKP) for the management of thoracolumbar osteoporotic vertebral compression fractures(OVCFs).
METHODS:
A retrospective cohort study was conducted, comprising 62 patients with single-segment thoracolumbar OVCFs (T11-L2), who underwent bilateral PKP at our department during the period from June 2020 to October 2021. Patients were categorized into two groups based on the specific bone cement injector employed during the surgical procedure: the side-opening group (n=29) and the front-opening group (n=33). Among them, the side-opening group consisted of 6 male and 23 female patients, with a mean age of (73.32±9.11) years. The front-opening group included 7 male and 26 female patients, with a mean age of (71.29±10.39) years. The variables encompassed essential patient characteristics were recorded, such as gender, age, bone mineral density (BMD), and fracture level (T11-L2), as well as procedural aspects, including operation duration, cement injection volume, cement distribution type (lobular or diffuse), occurrence of cement leakage, pre-and post-operative visual analogue scale (VAS) pain scores, and vertebral compression ratio.
RESULTS:
All patients underwent successful surgery, with a mean follow-up duration of (15.37±3.03) months. There were no statistically significant differences in gender, age, BMD, fracture level, preoperative vertebral compression degree, and VAS scores between the side-opening group and the front-opening group (P>0.05). The operation time, the mean cement injection volumes, the distribution of bone cement within the vertebrae has no statistically significant difference between two groups(P>0.05). Both the side-opening and front-opening groups showed significant improvements in VAS scores at 3 days and 6 months after operation (P<0.05). However, there was no significant difference in VAS scores between the two groups at both 3 days and 6 months after the operation (P>0.05).
CONCLUSION
Side-opening bone cement injectors in bilateral PKP surgery for single-segment thoracolumbar OVCF achieve similar clinical efficacy as front-opening injectors, without significant improvement in cement distribution and containment.
Humans
;
Female
;
Male
;
Kyphoplasty/instrumentation*
;
Aged
;
Bone Cements
;
Fractures, Compression/surgery*
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Thoracic Vertebrae/injuries*
;
Lumbar Vertebrae/injuries*
;
Osteoporotic Fractures/surgery*
;
Middle Aged
;
Aged, 80 and over
6.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
7.The Korean Organ Transplant Registry (KOTRY): Third Official Adult Heart Transplant Report
Hyo-In CHOI ; Sang Eun LEE ; Junho HYUN ; Darae KIM ; Dong-Ju CHOI ; Eun-Seok JEON ; Hae-Young LEE ; Hyun-Jai CHO ; Hyungseop KIM ; In-Cheol KIM ; Jaewon OH ; Minjae YOON ; Jin Joo PARK ; Jin-Oh CHOI ; Min Ho JU ; Seok-Min KANG ; Soo Yong LEE ; Sung-Ho JUNG ; Jae-Joong KIM
Korean Circulation Journal 2025;55(2):79-96
Background and Objectives:
The Korean Organ Transplant Registry (KOTRY) provided data for this third official report on adult heart transplantation (HT), including information from 709 recipients.
Methods:
Data from HTs performed at seven major centers in Korea between March 2014 and December 2020 were analyzed, focusing on immunosuppression, acute rejection, cardiac allograft vasculopathy (CAV), post-transplant survival, and mechanical circulatory support (MCS) usage.
Results:
The median ages of the recipients and donors were 56.0 and 43.0 years, respectively.Cardiomyopathy and ischemic heart disease were the most common preceding conditions for HT. A significant portion of patients underwent HT at waiting list status 1 and 0. In the multivariate analysis, a predicted heart mass mismatch was associated with a higher risk of 1-year mortality. Patients over 70 years old had a significantly increased risk of 6-year mortality. The risk of CAV was higher for male donors and donors older than 45 years. Acute rejection was more likely in patients with panel reactive antibody levels above 80%, while statin use was associated with a reduced risk. The employment of left ventricular assist device as a bridge to transplantation increased from 2.17% to 22.4%. Pre-transplant extra-corporeal membrane oxygenation was associated with worse post-transplant survival.
Conclusions
In this third KOTRY report, we analyzed changes in the characteristics of adult HT recipients and donors and their impact on post-transplant outcomes. The most notable discovery was the increased use of MCS before HT and their impact on post-transplant outcomes.
8.Comparison of intraoperative neurophysiological monitoring between propofol and remimazolam during total intravenous anesthesia in the cervical spine surgery: a prospective, double-blind, randomized controlled trial
Myoung Hwa KIM ; Jinyoung PARK ; Yoon Ghil PARK ; Yong Eun CHO ; Dawoon KIM ; Dong Jun LEE ; Kyu Wan KWAK ; Jongyun LEE ; Dong Woo HAN
Korean Journal of Anesthesiology 2025;78(1):16-29
Background:
Although total intravenous anesthesia (TIVA) with propofol and remifentanil is frequently used to optimize intraoperative neurophysiological monitoring (IONM), the exact effect of remimazolam on IONM remains unknown. Here, we compared the effects of propofol and remimazolam along with remifentanil on IONM during TIVA.
Methods:
In this prospective, double-blind, randomized controlled trial, 64 patients requiring IONM during cervical spine surgery were administered either propofol (Group P) or remimazolam (Group R). The preoperative latencies of the somatosensory-evoked potentials (SEP; N20 for the median nerve and P37 for the tibial nerve) were measured. SEP latencies and amplitudes and motor-evoked potential (MEP) amplitudes were measured 30 min after anesthetic induction (T1), 30 min after surgical incision (T2), after laminectomy or discectomy (T3), immediately after plate insertion or pedicle screw fixation (T4), and before surgical wound closure (T5). The primary outcome was the between-group difference in the N20 latency changes measured at T1 and preoperatively.
Results:
The change in SEP latencies including N20 and P37 at T1 compared with preoperative time was not significantly different between Groups P and R. Except for the amplitude of the right abductor brevis, there was no significant group-by-time interaction effect for intraoperative MEP amplitudes or SEP latencies and amplitudes.
Conclusions
TIVA with remimazolam and remifentanil for cervical spine surgery yielded stable IONM, comparable to those observed with conventional TIVA with propofol and remifentanil. Further clinical trials are needed in other surgical contexts and with more diverse patient populations to determine the effects of remimazolam on IONM.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Hemicentral Retinal Vein Occlusion: Clinical Outcomes and Visual Prognostic Factors
Dong Woo LEE ; Do Yun SONG ; Mi-Ji KIM ; Yong Wun CHO ; Woong-Sun YOO ; In Young CHUNG
Journal of the Korean Ophthalmological Society 2025;66(2):94-100
Purpose:
To confirm the clinical features of hemicentral retinal vein occlusion and identify predictors of visual outcomes.
Methods:
A retrospective analysis was conducted on patients diagnosed with hemicentral retinal vein occlusion between January 2018 and December 2022 and followed for more than 6 months. Patients underwent intravitreal injections as necessary for intraretinal edema. Visual acuity, central macular thickness, ellipsoid zone damage, and the location of inner retinal layer edema were assessed. Patients were categorized into groups A and group B based on the visual acuity at 6 months.
Results:
In total, 20 eyes were followed, with 15 eyes observed for up to 12 months. Seven patients (35.0%) had diabetes and 11 (55.0%) had hypertension. There was a correlation between poor vision at 6 months and hypertension (p = 0.033). The visual acuity of all patients improved from a logMAR of 0.96 at the initial visit to a logMAR of 0.35 at 6 months (p = 0.005). In the group with good initial visual acuity, there were no significant changes in visual acuity during the follow-up period (p = 0.444). The group with good visual acuity at 6 months had a lower degree of photoreceptor ellipsoid zone disruption compared to the group with poor initial vision, indicating a normal structure (p = 0.015).
Conclusions
During follow-up of patients with hemicentral retinal vein occlusion, overall visual acuity improved over time. Patients with good initial acuity maintained it. Favorable visual outcomes can be expected if the ellipsoid zone has a normal structure at the time of the first examination.

Result Analysis
Print
Save
E-mail