1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
3.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
4.Current status and suggestions on regulation of traditional Chinese medicine raw materials and preparations under regulatory system of drugs.
Li-Ping QU ; Yong-Dan XU ; Wei-Jing HE ; Ding-Kun ZHANG ; Nan YANG ; Min-Xian SONG ; Zhi-Qiang MIN ; Ting-Mo ZHANG
China Journal of Chinese Materia Medica 2025;50(3):824-832
At present, the cause of traditional Chinese medicine(TCM) in China has entered a new period of high-quality development. How to strengthen the foundation for the TCM industry from the source is an important issue that deserves the attention of the authorities, industry, and academia. This study systematically analyzed the regulatory system of TCM raw materials and preparations. The study took the TCM industry chain and the product life cycle as a clue and focused on the dimensions of TCM resource protection and plant cultivation(farming), production and quality supervision of TCM raw materials and preparations, and their market access and distribution. It analyzed the current situation of the regulation of TCM raw materials and preparations under the regulatory system of drugs, discussed the main problems, and put forward corresponding suggestions. The results can provide an important reference value for the subsequent improvement of the regulatory system of drugs and the construction of a prominent regulatory system of drugs in accordance with TCM characteristics.
Drugs, Chinese Herbal/economics*
;
Medicine, Chinese Traditional/standards*
;
China
;
Quality Control
;
Humans
;
Plants, Medicinal/chemistry*
5.A new triterpenoid from Elephantopus scaber.
Zu-Xiao DING ; Hong-Xi XIE ; Lin CHEN ; Jun-Jie HAO ; Yan-Qiu LUO ; Zhi-Yong JIANG ; Shi-Kui XU
China Journal of Chinese Materia Medica 2025;50(5):1224-1230
The chemical constituents of the petroleum ether extract derived from the 90% ethanol extract of Elephantopus scaber were investigated. By silica gel column chromatography, C_(18), MCI column chromatography and semi-preparative high performance liquid chromatography, ten compounds were isolated. Their structures were identified as 3β-hydroxy-6β,7β-epoxytaraxeran-14-ene(1), 3β-hydroxyolean-12-en-28-oic acid(2), D-friedoolean-14-ene-3β,7α-diol(3), 3β-hydroxy-11α-methoxyolean-12-ene(4), 3β-hydroxyolean-11,13(18)-diene(5), 11α-hydroxy-β-amyrin(6), betulinic acid(7), 3β-hydroxy-30-norlupan-20-one(8), 6-acetonylchelerythrine(9), and 4',5'-dehydrodiodictyonema A(10) by analysis of the 1D NMR, 2D NMR, MS, and IR spectral data. Among them, compound 1 was a new triterpene and other compounds except compounds 2 and 7 were isolated from this plant for the first time.
Triterpenes/isolation & purification*
;
Drugs, Chinese Herbal/isolation & purification*
;
Molecular Structure
;
Asteraceae/chemistry*
;
Chromatography, High Pressure Liquid
;
Magnetic Resonance Spectroscopy
6.Advances in target-guided discovery technologies for active components in traditional Chinese medicine.
Meng DING ; Wang-Xiao TAN ; Xiao ZHANG ; Peng-Fei TU ; Yong JIANG
China Journal of Chinese Materia Medica 2025;50(13):3645-3656
Traditional Chinese medicine(TCM), with diverse structural types of active components and remarkable clinical efficacy, holds a significant position in the pharmacological research. As the key substances, active components of TCM are of great importance in revealing the material basis of TCM efficacy and mechanism of action. However, the conventional approaches of discovering active components in TCM are characterized by tedious procedures, lengthy cycles, and unclear mechanisms, which struggle to meet the current demands for drug development. In recent years, major breakthroughs have been made in target discovery technologies, and new drug targets are constantly being discovered, which has facilitated the development of target-driven approaches. The target-guided active component discovery strategy provides a new paradigm for discovering active components in TCM. This article systematically summarizes two mainstream target-based technologies-virtual screening and ligand fishing-for TCM active component discovery. By analyzing relevant application cases, this article evaluates the strengths and limitations of each technology. The review aims to provide frameworks for expediting bioactive component discovery in complex systems like TCM, so as to accelerate the development of innovative drugs based on the active components of TCM and promote the modernization and internationalization of TCM.
Drugs, Chinese Herbal/pharmacology*
;
Humans
;
Medicine, Chinese Traditional
;
Drug Discovery/methods*
;
Animals
7.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
9.Prediction of testicular histology in azoospermia patients through deep learning-enabled two-dimensional grayscale ultrasound.
Jia-Ying HU ; Zhen-Zhe LIN ; Li DING ; Zhi-Xing ZHANG ; Wan-Ling HUANG ; Sha-Sha HUANG ; Bin LI ; Xiao-Yan XIE ; Ming-De LU ; Chun-Hua DENG ; Hao-Tian LIN ; Yong GAO ; Zhu WANG
Asian Journal of Andrology 2025;27(2):254-260
Testicular histology based on testicular biopsy is an important factor for determining appropriate testicular sperm extraction surgery and predicting sperm retrieval outcomes in patients with azoospermia. Therefore, we developed a deep learning (DL) model to establish the associations between testicular grayscale ultrasound images and testicular histology. We retrospectively included two-dimensional testicular grayscale ultrasound from patients with azoospermia (353 men with 4357 images between July 2017 and December 2021 in The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China) to develop a DL model. We obtained testicular histology during conventional testicular sperm extraction. Our DL model was trained based on ultrasound images or fusion data (ultrasound images fused with the corresponding testicular volume) to distinguish spermatozoa presence in pathology (SPP) and spermatozoa absence in pathology (SAP) and to classify maturation arrest (MA) and Sertoli cell-only syndrome (SCOS) in patients with SAP. Areas under the receiver operating characteristic curve (AUCs), accuracy, sensitivity, and specificity were used to analyze model performance. DL based on images achieved an AUC of 0.922 (95% confidence interval [CI]: 0.908-0.935), a sensitivity of 80.9%, a specificity of 84.6%, and an accuracy of 83.5% in predicting SPP (including normal spermatogenesis and hypospermatogenesis) and SAP (including MA and SCOS). In the identification of SCOS and MA, DL on fusion data yielded better diagnostic performance with an AUC of 0.979 (95% CI: 0.969-0.989), a sensitivity of 89.7%, a specificity of 97.1%, and an accuracy of 92.1%. Our study provides a noninvasive method to predict testicular histology for patients with azoospermia, which would avoid unnecessary testicular biopsy.
Humans
;
Male
;
Azoospermia/diagnostic imaging*
;
Deep Learning
;
Testis/pathology*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Sperm Retrieval
;
Sertoli Cell-Only Syndrome/diagnostic imaging*
10.Impact of admission-blood-glucose-to-albumin ratio on all-cause mortality and renal prognosis in critical patients with coronary artery disease: insights from the MIMIC-IV database.
Yong HONG ; Bo-Wen ZHANG ; Jing SHI ; Ruo-Xin MIN ; Ding-Yu WANG ; Jiu-Xu KAN ; Yun-Long GAO ; Lin-Yue PENG ; Ming-Lu XU ; Ming-Ming WU ; Yue LI ; Li SHENG
Journal of Geriatric Cardiology 2025;22(6):563-577
BACKGROUND:
Blood glucose and serum albumin have been associated with cardiovascular disease prognosis, but the impact of admission-blood-glucose-to-albumin ratio (AAR) on adverse outcomes in critical ill coronary artery disease (CAD) patients was not investigated.
METHODS:
Patients diagnosed with CAD were non-consecutively selected from the MIMIC-IV database and categorized into quartiles based on their AAR. The primary outcome was 1-year mortality, and secondary endpoints were in-hospital mortality, acute kidney injury (AKI), and renal replacement therapy (RRT). A restricted cubic splines model and Cox proportional hazard models assessed the association between AAR and adverse outcomes in CAD patients. Kaplan-Meier survival analysis determined differences in endpoints across subgroups.
RESULTS:
A total of 8360 patients were included. There were 726 patients (8.7%) died in the hospital and 1944 patients (23%) died at 1 year. The incidence of AKI and RRT was 63% and 4.3%, respectively. High AAR was markedly associated with in-hospital mortality (HR = 1.587, P = 0.003), 1-year mortality (HR = 1.502, P < 0.001), AKI incidence (HR = 1.579, P < 0.001), and RRT (HR = 1.640, P < 0.016) in CAD patients in the completely adjusted Cox proportional hazard model. Kaplan-Meier survival analysis noted substantial differences in all endpoints based on AAR quartiles. Stratified analysis and interaction test demonstrated stable correlations between AAR and outcomes.
CONCLUSIONS
The results highlight that AAR may be a potential indicator for assessing in-hospital mortality, 1-year mortality, and adverse renal prognosis in critical CAD patients.

Result Analysis
Print
Save
E-mail