1.Valve-in-valve transcatheter mitral valve replacement with SAPIEN 3 valve for bioprosthetic mitral valve failure: one-year outcomes in 26 patients.
Zechao RAN ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Tingqian CAO ; Siyu HE ; Xiaoting LI ; Yingqiang GUO
Journal of Zhejiang University. Medical sciences 2025;54(5):668-675
OBJECTIVES:
To evaluate the one-year outcomes of valve-in-valve transcatheter mitral valve replacement (ViV-TMVR) using SAPIEN 3 valve for treating mitral bioprosthetic valve failure.
METHODS:
A retrospective analysis was conducted on 26 patients with mitral bioprosthetic valve failure who underwent ViV-TMVR at West China Hospital, Sichuan University, between November 2022 and July 2024. The age of patients was 71.5 (64.5, 74.5) years, and 69.2% were female. Bioprosthetic valve failure occurred at (9.7±3.7) years after initial surgical implantation, with the most common failure mode being mixed stenosis and regurgitation (53.8%). The SAPIEN 3 valve was implanted via either a transseptal or transapical approach. Echocardiography was performed preoperatively, immediately post-procedure, and at 1 month, 6 months, and 1 year post-procedure. Outcomes included all-cause mortality, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 score, and postoperative complications.
RESULTS:
The procedure was performed via the transseptal approach in 21 patients (80.8%) and the transapical approach in 5 patients (19.2%). All procedures were technically successful. No paravalvular leakage was observed immediately post-procedure, and mitral valve hemodynamics improved significantly. At the 1-year follow-up, 2 patients had died. Two patients (8.3% of survivors) were of NYHA functional class Ⅲ, and KCCQ-12 score improved to (88.4±14.6) points (both P<0.01). Echocardio-graphy at 1 year postoperatively showed significant reductions in peak mitral valve velocity [to (2.29±0.32) m/s] and mean transvalvular pressure gradient [to (9.5±3.5) mmHg, 1 mmHg=0.133 kPa] compared to baseline (both P<0.05). No moderate or severe mitral regurgitation or paravalvular leakage was observed. The proportion of patients with moderate-to-severe pulmonary hypertension decreased from 65.4% preoperatively to 13.0% at 1 year (P<0.05).
CONCLUSIONS
ViV-TMVR with the SAPIEN 3 valve for mitral biopro-sthetic valve failure is associated with high procedural success, significantly improved valve hemodynamics of the mitral value, alleviation of pulmonary hypertension, enhanced quality of life, and a low rate of complications at 1 year after the operation.
Humans
;
Female
;
Male
;
Retrospective Studies
;
Aged
;
Bioprosthesis
;
Heart Valve Prosthesis
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Middle Aged
;
Prosthesis Failure
;
Treatment Outcome
;
Mitral Valve Insufficiency/surgery*
2.Preliminary effectiveness of the whole-life cycle management model for valvular heart disease at West China Hospital: A retrospective cohort study
Zechao RAN ; Yuqiang WANG ; Siyu HE ; Shitong ZHONG ; Tingqian CAO ; Xiang LIU ; Zeruxin LUO ; Lulu LIU ; Jun SHI ; Yingqiang GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(07):968-976
Objective To propose a whole-life cycle management model for valvular heart disease (VHD), systematically elucidate its underlying logic and implementation pathways, and concurrently review and analyze its preliminary application outcomes. Methods Since 2020, West China Hospital of Sichuan University has established a management system encompassing "assessment-decision-intervention-follow-up", including: (1) a risk-stratified, tiered management pathway; (2) six core functions ("promotion, screening, prevention, diagnosis, treatment, and rehabilitation") coordinated by disease-specific managers; (3) an intelligent decision support information platform; and (4) a collaborative network of multidisciplinary teams and regional academic alliances. To evaluate the effectiveness of this management model, we retrospectively included three cohorts: (1) the population screened by echocardiography from 2020 to 2024, analyzing the detection rate of aortic valve disease and risk stratification; (2) patients enrolled in the whole-life cycle management from April 2021 to December 2024, assessing follow-up outcomes, hospital satisfaction, and changes in quality of life; (3) patients who underwent transcatheter aortic valve replacement (TAVR) from January 2022 to January 2024, evaluating the one-year all-cause mortality rate, perioperative complications, and improvements in New York Heart Association (NYHA) classification. Results Between 2020 and 2024, a total of 583 874 individuals underwent echocardiographic screening. A total of 48 089 patients with aortic valve disease were identified, including 3 401 (7.1%) high-risk patients, 18 657 (38.8%) moderate-risk patients, and 26 031 (54.1%) low-risk patients. Among them, 2 417 patients were enrolled in whole-life cycle management. Patient satisfaction scores showed a yearly increase, rising from 73.89 points before 2020 to 93.74 points in 2024. The 1-year mortality rate in the TAVR cohort decreased to 5.3%, significantly lower than the 8.2% observed under early standard management between 2014 and 2019 (P<0.01). Conclusion Through process optimization and resource integration, the VHD whole-life cycle management model has demonstrated significant effectiveness in standardizing diagnostic and follow-up procedures, enhancing patient satisfaction and quality of life, and reducing mortality. These outcomes highlight its practical value for broader implementation in China.
3.Transcatheter aortic valve replacement for elderly patients with severe aortic valve stenosis and bicuspid aortic valve
Xiaoting LI ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Zechao RAN ; Yingqiang GUO
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(8):460-466
Objective:To investigate the safety and efficacy of transcatheter aortic valve replacement (TAVR) with self-expandable bioprosthetic valves (Evolut PRO, Medtronic Inc.) in elderly patients with aortic stenosis.Methods:This single-center, single-arm, retrospective cohort study included all consecutive patients who underwent TAVR using Evolut PRO at West China Hospital of Sichuan University between May 2022 and July 2024, and collected all their data at baseline, postoperative, and 30 days. The primary endpoint was all-cause mortality, and secondary endpoints included cardiac mortality, stroke, permanent pacemaker implantation(PPI), bleeding events, vascular and peripheral access complications, acute kidney injury, and hemodynamic data.Results:70 patients were included in the study, including 25 of (35.7%) tricuspid aortic valve (TAV), 23 (32.9%) of Type 0 bicuspid aortic valve (BAV) 20 (28.6%) of Type 1 BAV, and 2 (2.9%) of Type 2 BAV. The mean age was (72.9±6.6) years, 37 (52.9%) were male, and 70 (100%) had a New York Heart Association (NYHA) grade Ⅲ or Ⅳ. Sixty-nine (98.6%) achieved successful surgery, and 1 patient (1.4%) was converted intraoperatively to open-chest surgery. At 30 days, all-cause and cardiovascular mortality were 0, the incidence of stroke was 0, the rate of PPI was 8.7%, and no moderate or greater paravalvular leaks were observed. All patients improved to Class Ⅰ or Ⅱ after receiving TAVR. The mean aortic valve gradient (AVG) decreased from (54.1 ± 18.0 )mmHg(1mmHg=0.133kPa) at baseline to (10.5 ± 5.2)mmHg at 30 days. There were no significant differences in the results among the Type 0 BAV, Type 1/2 BAV, and TAV groups.Conclusion:Evolut PRO is safe and effective in early clinical treatment of elderly patients with aortic valve stenosis.
4.The role of diagnostic whole body scan in decision-making of 131I treatment for differentiated thyroid cancer
Xiaotong JIANG ; Jinchuan LIU ; Yingqiang ZHANG ; Tong WANG ; Ning GUO ; Yuqing SUN ; Cong SHI ; Bing YAN ; Yansong LIN
China Oncology 2025;35(1):77-84
Background and purpose:As one of the first-line treatment methods for differentiated thyroid cancer(DTC),131I treatment is an important therapeutic approach for most patients with medium-high recurrence risk DTC after total or near-total thyroidectomy.Risk stratification and real-time dynamic assessment before 131I treatment after surgery are important steps in deciding on 131I treatment,enabling individualized treatment.This retrospective study aimed to explore the role of diagnostic whole body scan(DxWBS)in the decision-making of treatment for DTC after surgery and before 131I therapy.Methods:DTC patients who underwent pre-ablation evaluation were included.Patients were divided into low,medium and high sTg groups based on their pre-131I treatment stimulated thyroglobulin(sTg)levels(<1 ng/mL,1 ng/mL≤sTg<10 ng/mL,sTg≥10 ng/mL).The concordance rates of DxWBS and post treatment whole body scan(RxWBS)in each patient of the whole cohort were compared.The lesion detection rate between DxWBS and RxWBS in different sTg level groups was also explored.The"thyroid stunning effect"by DxWBS was evaluated by RxWBS.Through these analyses,the role of DxWBS in 131I treatment decision-making and its predicting treatment objectives were assessed.This study was approved by the Ethics Committee of Peking Union Medical College Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences(ethics number:JS-2151).Results:A total of 91 patients were included.The low,medium and high sTg groups accounted for 15.4%(14/91),34.1%(31/91)and 50.5%(46/91)of the patients,respectively.Comparison of DxWBS and RxWBS results in the same patients in each sTg group showed no evidence of a stunning effect on 131I treatment.The overall concordance rate between DxWBS and RxWBS was 89.0%(81/91);In different sTg level groups was 100.0%(14/14),90.3%(28/31),84.8%(39/46)respectively.Taking sTg levels into consideration,DxWBS accurately predicted the need for total thyroidectomy,with a 100%(20/20)agreement with RxWBS.Among the 71 patients who received adjuvant therapy and/or remnant ablation due to suspected elevated Tg or high recurrence risk stratification or the iodine-avid metastatic lesions identified by DxWBS,87.5%(63/71)showed only residual thyroid tissue by DxWBS;Through the purpose verification by RxWBS and single photon emission computed tomography(SPECT)/CT,only 12.7%(9/71)of cases were verified as adjuvant or tumoricidal treatment due to iodine-avid cervical lymph node and/or lung metastasis identified by RxWBS,87.3%(62/71)were residual thyroid ablation.In the medium and high sTg group,the overall detection rate of functional cervical lymph node metastasis by DxWBS and RxWBS was 5.5%(5/91).For the detection of functional lung metastases,the overall detection rate of DxWBS was slightly lower than that of RxWBS(3.3%vs 5.5%).This indicates that DxWBS can be used to accurately pre-judge the purposes of 131I treatment,particularly for thyroid ablation and adjuvant therapy.Conclusion:DxWBS did not induce"thyroid stunning"effect.Integrating DxWBS as a theranostic tool into the real-time decision-making and evaluation system of 131I treatment,as well as with sTg and other biochemical indicators,may help to bridge the limitations of static evaluations based on pathology and clinical data,and provides a clear understanding and more precise objectives of 131I treatment.
5.Transcatheter aortic valve replacement for elderly patients with severe aortic valve stenosis and bicuspid aortic valve
Xiaoting LI ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Zechao RAN ; Yingqiang GUO
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(8):460-466
Objective:To investigate the safety and efficacy of transcatheter aortic valve replacement (TAVR) with self-expandable bioprosthetic valves (Evolut PRO, Medtronic Inc.) in elderly patients with aortic stenosis.Methods:This single-center, single-arm, retrospective cohort study included all consecutive patients who underwent TAVR using Evolut PRO at West China Hospital of Sichuan University between May 2022 and July 2024, and collected all their data at baseline, postoperative, and 30 days. The primary endpoint was all-cause mortality, and secondary endpoints included cardiac mortality, stroke, permanent pacemaker implantation(PPI), bleeding events, vascular and peripheral access complications, acute kidney injury, and hemodynamic data.Results:70 patients were included in the study, including 25 of (35.7%) tricuspid aortic valve (TAV), 23 (32.9%) of Type 0 bicuspid aortic valve (BAV) 20 (28.6%) of Type 1 BAV, and 2 (2.9%) of Type 2 BAV. The mean age was (72.9±6.6) years, 37 (52.9%) were male, and 70 (100%) had a New York Heart Association (NYHA) grade Ⅲ or Ⅳ. Sixty-nine (98.6%) achieved successful surgery, and 1 patient (1.4%) was converted intraoperatively to open-chest surgery. At 30 days, all-cause and cardiovascular mortality were 0, the incidence of stroke was 0, the rate of PPI was 8.7%, and no moderate or greater paravalvular leaks were observed. All patients improved to Class Ⅰ or Ⅱ after receiving TAVR. The mean aortic valve gradient (AVG) decreased from (54.1 ± 18.0 )mmHg(1mmHg=0.133kPa) at baseline to (10.5 ± 5.2)mmHg at 30 days. There were no significant differences in the results among the Type 0 BAV, Type 1/2 BAV, and TAV groups.Conclusion:Evolut PRO is safe and effective in early clinical treatment of elderly patients with aortic valve stenosis.
6.The role of diagnostic whole body scan in decision-making of 131I treatment for differentiated thyroid cancer
Xiaotong JIANG ; Jinchuan LIU ; Yingqiang ZHANG ; Tong WANG ; Ning GUO ; Yuqing SUN ; Cong SHI ; Bing YAN ; Yansong LIN
China Oncology 2025;35(1):77-84
Background and purpose:As one of the first-line treatment methods for differentiated thyroid cancer(DTC),131I treatment is an important therapeutic approach for most patients with medium-high recurrence risk DTC after total or near-total thyroidectomy.Risk stratification and real-time dynamic assessment before 131I treatment after surgery are important steps in deciding on 131I treatment,enabling individualized treatment.This retrospective study aimed to explore the role of diagnostic whole body scan(DxWBS)in the decision-making of treatment for DTC after surgery and before 131I therapy.Methods:DTC patients who underwent pre-ablation evaluation were included.Patients were divided into low,medium and high sTg groups based on their pre-131I treatment stimulated thyroglobulin(sTg)levels(<1 ng/mL,1 ng/mL≤sTg<10 ng/mL,sTg≥10 ng/mL).The concordance rates of DxWBS and post treatment whole body scan(RxWBS)in each patient of the whole cohort were compared.The lesion detection rate between DxWBS and RxWBS in different sTg level groups was also explored.The"thyroid stunning effect"by DxWBS was evaluated by RxWBS.Through these analyses,the role of DxWBS in 131I treatment decision-making and its predicting treatment objectives were assessed.This study was approved by the Ethics Committee of Peking Union Medical College Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences(ethics number:JS-2151).Results:A total of 91 patients were included.The low,medium and high sTg groups accounted for 15.4%(14/91),34.1%(31/91)and 50.5%(46/91)of the patients,respectively.Comparison of DxWBS and RxWBS results in the same patients in each sTg group showed no evidence of a stunning effect on 131I treatment.The overall concordance rate between DxWBS and RxWBS was 89.0%(81/91);In different sTg level groups was 100.0%(14/14),90.3%(28/31),84.8%(39/46)respectively.Taking sTg levels into consideration,DxWBS accurately predicted the need for total thyroidectomy,with a 100%(20/20)agreement with RxWBS.Among the 71 patients who received adjuvant therapy and/or remnant ablation due to suspected elevated Tg or high recurrence risk stratification or the iodine-avid metastatic lesions identified by DxWBS,87.5%(63/71)showed only residual thyroid tissue by DxWBS;Through the purpose verification by RxWBS and single photon emission computed tomography(SPECT)/CT,only 12.7%(9/71)of cases were verified as adjuvant or tumoricidal treatment due to iodine-avid cervical lymph node and/or lung metastasis identified by RxWBS,87.3%(62/71)were residual thyroid ablation.In the medium and high sTg group,the overall detection rate of functional cervical lymph node metastasis by DxWBS and RxWBS was 5.5%(5/91).For the detection of functional lung metastases,the overall detection rate of DxWBS was slightly lower than that of RxWBS(3.3%vs 5.5%).This indicates that DxWBS can be used to accurately pre-judge the purposes of 131I treatment,particularly for thyroid ablation and adjuvant therapy.Conclusion:DxWBS did not induce"thyroid stunning"effect.Integrating DxWBS as a theranostic tool into the real-time decision-making and evaluation system of 131I treatment,as well as with sTg and other biochemical indicators,may help to bridge the limitations of static evaluations based on pathology and clinical data,and provides a clear understanding and more precise objectives of 131I treatment.
7.Transcatheter valve implantation for aortic and tricuspid valve regurgitation: A case report
Bowen XIAO ; Lulu LIU ; Binggang WU ; Jun SHI ; Yingqiang GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):929-932
Transcatheter aortic valve implantation (TAVI) is an important alternative in treating high-risk patients with aortic valve regurgitation. Transcatheter tricuspid valve implantation (TTVI) is also an important treatment option for high-risk patients with tricuspid regurgitation. We reported a 72-year male patient who underwent TAVI due to severe aortic valve regurgitation using a J-Valve. During a two-year follow-up, the patient developed secondary tricuspid regurgitation to atrial fibrillation, and subsequently received TTVI using a LuX-Valve. Following the interventions, the patient's symptoms were significantly improved, and echocardiography indicated good hemodynamic performance of both transcatheter heart valves. This case highlights the feasibility and effectiveness of performing multiple valve implantations via transcatheter approaches in high-risk elderly patients.
8.Qualitative systematic review of the safety and feasibility of early mobilization in critically ill patients with femoral catheters
Yuqiang WANG ; Yingqiang GUO ; Wei HUANG ; Lei LI ; Jun SHI ; Pengming YU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(03):434-439
Objective To investigate the safety and feasibility of early mobilization in critically ill patients with femoral catheters, and to provide reference for guiding clinical rehabilitation training. Methods The literature on the safety and feasibility of early mobilization in critically ill patients with femoral catheters included in PubMed, EMbase, OVID, Springer-link, Wiley Online Library, and Web of Science up to June 2021 was searched, and relevant data were extracted for analysis. Results Seventy-two papers were initially screened, and 12 papers that met the criteria were finally included, covering 1 056 patients, and 489 patients had femoral catheters. Patients underwent 6 495 sessions of physical therapy, and a total of 62 patients had adverse events, including 14 (2.86%, 14/489) patients with catheter-related adverse events. Conclusion Although early mobilization in critically ill patients with femoral catheters may lead to adverse catheter-related events, the incidence is low. Therefore, the associated risks and benefits should be weighed in clinical practice, and femoral catheter is not recommended as a contraindication for early mobilization in critically ill patients.
9.Procedure specifications for transapical transcatheter aortic valve replacement
Jun SHI ; Yuan ZHAO ; Yingqiang GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(04):491-500
Transcatheter aortic valve replacement (TAVR) techniques have been rapidly developed in recent years. Current guidelines and studies mainly focus on aortic stenosis patients treated by transfemoral approach, but they are not completely appropriate to patients with isolated aortic regurgitation or other patients who need transapical TAVR (TA-TAVR), which affects the standardized treatment of those patients. Therefore, our team pronounced the operational standards for TA-TAVR, based on fully reviewing the literatures worldwide, combined with the opinions of experts from 15 heart centers with rich experience in carrying out TA-TAVR in China. This standard aims to provide clinicians with standardized diagnosis and treatment principles of TA-TAVR and improve the quality of TA-TAVR in China.
10.First exploration of postoperative pulmonary complications after transcatheter tricuspid valve replacement and recommendations for rehabilitation: A prospective cohort study
Yuqiang WANG ; Jun SHI ; Lulu LIU ; Zeruxin LUO ; Fengmei ZHANG ; Yingqiang GUO ; Pengming YU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(08):963-970
Objective To investigate the morbidity of postoperative pulmonary complications (PPCs) in patients after transcatheter tricuspid valve replacement (TTVR). Methods A prospective cohort study enrolled 19 patients who were diagnosed with severe or greater tricuspid regurgitation in West China Hospital from October 11, 2020 to March 1, 2021, and would receive TTVR using LuX-valve for valve replacement. The patients were divided into a PPCs group and a non-PPCs group according to the presence of PPCs. The incidence of PPCs after tricuspid valve intervention between the two groups was compared. Results Of 19 patients diagnosed with severe or greater tricuspid regurgitation registered in the database, 17 met the inclusion criteria, including 15 females and 2 males, with a mean age of 68.4±8.0 years. PPCs occurred in 9 of 17 (52.9%) patients. At discharge, compared with the non-PPCs group, the PPCs group had a longer postoperative hospital stay [11.0 (10.0, 17.0) d vs. 7.5 (7.0, 8.0) d, P=0.01], longer ICU stay [72.0 (45.5, 95.0) h vs. 20.5 (16.0, 22.8) h, P<0.01], and more hospital cost [74.3 (65.9, 98.3) thousand yuan vs. 52.6 (44.2, 57.4) thousand yuan, P<0.01]. At 30 days of follow-up, the PPCs group was found that the rate of New York Heart Association cardiac function≥class Ⅲ (66.7% vs. 12.5%, P<0.01) was higher, the six-minute walk distance (170.2±169.3 m vs. 377.9±80.5 m, P<0.01) was shorter and Kansas City Cardiomyopathy Questionnaire heart failure score (40.9±31.2 vs. 80.4±5.8, P<0.01) was less than those of the non-PPCs group. Conclusion PPCs are common in the patients undergoing TTVR and severely affect patients' cardiac function, exercise function and quality-of-life recovery. Proactive preoperative intervention as well as early postoperative rehabilitation management should be provided to those at high risk of PPCs.

Result Analysis
Print
Save
E-mail