1.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
2.TGF-β1-engineered Biomimetic Platelet Nanoparticles for Targeted Therapy of Ischemic Stroke
Li-Qi CHEN ; Tian-Fang KANG ; Guo-Jun HUANG ; Ting YIN ; Ai-Qing MA ; Lin-Tao CAI ; Hong PAN
Progress in Biochemistry and Biophysics 2026;53(3):697-710
ObjectivePost-ischemic acute inflammation and the subsequent persistent dysregulation of the immune microenvironment represent major pathological drivers that aggravate neuronal injury and severely restrict functional recovery following ischemic stroke. Although current reperfusion therapies partially restore blood flow, they fail to effectively modulate the secondary inflammatory cascade and oxidative stress, which remain critical barriers to neurological restoration. To address this challenge, this study aimed to engineer and systematically evaluate a biomimetic nanosystem composed of transforming growth factor-β1 (TGF-β1)-loaded platelet membrane-camouflaged lipid nanoparticles (PLP). This nanosystem was designed to achieve dual lesion-targeted delivery and immune microenvironment remodeling. By verifying its spatiotemporal accumulation, anti-inflammatory activity, and neuroprotective efficacy, we sought to establish an integrated therapeutic strategy that simultaneously enables lesion targeting, immune regulation, and functional recovery after ischemic injury. MethodsThe physicochemical properties of PLP, including hydrodynamic particle size, zeta potential, structural stability, and morphology, were characterized using dynamic light scattering, zeta potential analysis, and transmission electron microscopy. The preservation of platelet membrane-derived adhesion and immunoregulatory proteins was confirmed by SDS-PAGE through comparative analysis of protein band profiles between PLP and native platelet membranes. The in vitro biological activities of PLP were evaluated using two complementary cellular models. LPS-induced M1-polarized RAW264.7 macrophages were employed to assess inflammatory modulation, while oxygen glucose deprivation/reperfusion (OGD/R)-induced BV2 microglial cells and SH-SY5Y neuronal cells were utilized to investigate neuroinflammatory regulation and neuronal protection. For in vivo validation, a transient middle cerebral artery occlusion (tMCAO) mouse model was established to mimic ischemia-reperfusion injury. The spatiotemporal biodistribution and lesion-targeting capability of the PLP were monitored through live fluorescence imaging. Therapeutic efficacy was comprehensively evaluated by triphenyltetrazolium chloride (TTC) staining, glial fibrillary acidic protein (GFAP) immunofluorescence analysis, body weight monitoring, and neurological severity score (NSS) assessment. ResultsPLP nanoparticles displayed a uniform spherical morphology, nanoscale particle size distribution, and stable negative surface charge, indicating favorable colloidal stability and circulation potential. SDS-PAGE results confirmed the effective retention of key platelet membrane proteins associated with endothelial adhesion, immune evasion, and inflammatory regulation, demonstrating the successful biomimetic construction. Optimal therapeutic concentrations were determined in OGD/R-induced BV2 cells, where PLP exhibited excellent cytocompatibility and anti-inflammatory activity.In vitro experiments demonstrated that PLP significantly inhibited the polarization of RAW264.7 macrophages toward the pro-inflammatory M1 phenotype and markedly reduced neuronal apoptosis under ischemia-reperfusion conditions. In vivo fluorescence imaging revealed that PLP rapidly accumulated in the ischemic brain hemisphere and maintained prolonged retention for up to 7 d, suggesting enhanced lesion-specific targeting and sustained drug release. Compared with control group, PLP treatment significantly reduced cerebral infarct volume, attenuated reactive astrogliosis, improved weight recovery, and accelerated neurological functional restoration, as reflected by significantly improved NSS scores. ConclusionThis study establishes a multifunctional biomimetic nanoplatform that integrates platelet membrane-mediated active targeting with the anti-inflammatory, antioxidative, and neuroprotective properties of TGF-β1. The PLP system enables rapid lesion homing and long-term retention while synergistically regulating the post-stroke inflammatory microenvironment by suppressing pro-inflammatory immune activation, reducing neuronal apoptosis, and limiting excessive astrocyte reactivity. Importantly, this study proposes a conceptually therapeutic paradigm that combines targeted delivery with immune microenvironment remodeling to achieve comprehensive neurovascular protection. These findings provide strong experimental evidence supporting the translational potential of biomimetic nanotherapeutics as next-generation precision interventions for ischemic stroke.
3.Clinical rapid evaluation of proprotein convertase subtilisin/kexin type 9 inhibitors for hypercholesterolemia
Xin YAO ; Fengjiao KANG ; Qinan YIN ; Lizhu HAN ; Yuan BIAN
China Pharmacy 2026;37(2):149-154
OBJECTIVE To conduct a clinical rapid evaluation of the marketed proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors in China, including evolocumab, tafolecimab, recaticimab, ebronucimab, ongericimab and inclisiran. METHODS Based on the Rapid Guide for Drug Evaluation and Selection in Chinese Medical Institutions (second edition), drug instructions, clinical diagnosis and treatment guidelines, and literature for six drugs were retrieved from CNKI, Wanfang Data, VIP, PubMed, Embase, Cochrane Library and related official websites. The clinical rapid evaluation was conducted from five aspects: pharmaceutical characteristics, effectiveness, safety, economy, and other attributes. RESULTS The pharmaceutical characteristics, effectiveness, safety, economy, other attributes, and total score of evolocumab scored 24, 27, 15.7, 10, 5.3, and 82 points, respectively. Tafolecimab scored 23.5, 23, 11.5, 9.97, 4.6, and 72.57 points, respectively. Recaticimab scored 20.5, 22, 15.5, 6.37, 3.5, and 67.87 points. Ebronucimab scored 20, 23, 11, 6.48, 3.5, and 63.98 points. Ongericimab scored 20.5, 23, 8.5, 4.83, 3.5, and 60.33 points. Inclisiran scored 25.5, 24, 13, 6.48, 5, and 73.98 points. CONCLUSIONS Evolocumab is the optimal choice for treating hypercholesterolemia and is recommended as the first-line option. Tafolecimab is the second-line option, and recaticimab is suitable for patients who are sensitive to drug adverse reactions. Inclisiran is suitable for patients with poor compliance. Ebronucimab and ongericimab are weakly recommended due to their later market introduction. Clinicians should make individualized drug selections based on factors such as patient risk level and compliance requirements.
4.Imaging Evaluation for Steatotic Liver Disease
Shin Mei CHAN ; Vitor F MARTINS ; Kathleen MARSH ; Kang WANG ; Jake T WEEKS ; Aiguo HAN ; Meng YIN ; Kathryn J. FOWLER ; Claude B. SIRLIN ; Cheng William HONG
Korean Journal of Radiology 2026;27(2):137-151
Metabolic dysfunction-associated steatotic liver disease (MASLD), previously known as nonalcoholic fatty liver disease, is the fastest-growing cause of chronic liver disease worldwide, affecting approximately 30% of the global population.Imaging is vital for detecting, quantifying, and monitoring hepatic steatosis—the defining abnormality of MASLD—and subsequent fibrosis—the key determinant of liver-related outcomes. This review summarizes the principles, clinical usage, efficacy, and advancements in various imaging modalities for the noninvasive assessment of hepatic steatosis and fibrosis, with an emphasis on ultrasound, CT, and MRI. Additionally, this review explores the evolving landscape of MASLD diagnostic approaches, including machine-learning techniques, opportunistic screening, standardized imaging guidelines, and therapies, emphasizing the pivotal role that radiologists can play in shaping these developments.
5.Response to “Considerations in Imaging-Based Assessment of Steatotic Liver Disease to Enhance Harmonization, Longitudinal Interpretation, and Clinical Implementation”
Shin Mei CHAN ; Vitor F. MARTINS ; Kathleen MARSH ; Kang WANG ; Jake T. WEEKS ; Aiguo HAN ; Meng YIN ; Kathryn J. FOWLER ; Claude B. SIRLIN ; Cheng William HONG
Korean Journal of Radiology 2026;27(6):591-594
6.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
7.Development of a Microstream End-Tidal Carbon Dioxide Monitoring System with Integrated Gas Circuit.
Yanan LIU ; Xuedong SONG ; Qi YIN ; Fuhao KANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(2):204-211
End-tidal carbon dioxide monitoring is an important means of evaluating human lung function and is widely used in fields such as clinical emergency treatment and cardiopulmonary resuscitation. This paper develops a microstream end-tidal carbon dioxide monitoring system. It adopts an integrated gas circuit design to further reduce the size of the equipment. The system uses the method of calculating the root mean square (RMS) of differential pressure signals to regulate the gas circuit flow, enabling the system to stably operate at a flow state of 30 mL/min. In addition, by simultaneously detecting multiple environmental parameters such as temperature and pressure, the system realizes system state monitoring and gas parameter compensation. The test results show that various indicators of the system meet the requirements of relevant standards, laying a good foundation for subsequent engineering applications.
Carbon Dioxide/analysis*
;
Equipment Design
;
Monitoring, Physiologic/methods*
;
Humans
8.Sixteen-Channel Multimodal High-Precision Transcranial Electrical Stimulation System Development.
Yan HANG ; Qi YIN ; Lin HUANG ; Fuhao KANG ; Yanan LIU ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(4):435-443
This paper introduces a 16-channel multimodal high-precision transcranial electrical stimulation system specifically for non-invasive brain stimulation. This system added TMCS mixed four traditional stimulation modes with TACS, TDCS, TPCS and TRNS. By designing a compensated high-precision constant current source, the constant stimulation current with an accuracy of 0.03 mA in the range of ±2 mA and the stimulation frequency of 50~200 kHz with low frequency of 0~4 kHz (high frequency of 0.1 Hz) are realized. In TACS stimulation mode, there are five adjustable wave forms: triangular wave, sine wave, sawtooth wave, square wave and mixed wave. The system has dual closed-loop control overcurrent detection and simultaneous real-time electrode contact impedance detection. After relevant tests and verification, the system has good stimulation accuracy, high safety and reliability. Compared with the existing products at home and abroad, it features lower cost, richer stimulation mode and waveforms, demonstrating a certain market application value.
Transcranial Direct Current Stimulation/instrumentation*
;
Equipment Design
;
Humans
9.Stir-fried Semen Armeniacae Amarum Suppresses Aristolochic Acid I-Induced Nephrotoxicity and DNA Adducts.
Cheng-Xian LI ; Xiao-He XIAO ; Xin-Yu LI ; Da-Ke XIAO ; Yin-Kang WANG ; Xian-Ling WANG ; Ping ZHANG ; Yu-Rong LI ; Ming NIU ; Zhao-Fang BAI
Chinese journal of integrative medicine 2025;31(2):142-152
OBJECTIVE:
To investigate the protective effects of stir-fried Semen Armeniacae Amarum (SAA) against aristolochic acid I (AAI)-induced nephrotoxicity and DNA adducts and elucidate the underlying mechanism involved for ensuring the safe use of Asari Radix et Rhizoma.
METHODS:
In vitro, HEK293T cells overexpressing Flag-tagged multidrug resistance-associated protein 3 (MRP3) were constructed by Lentiviral transduction, and inhibitory effect of top 10 common pairs of medicinal herbs with Asari Radix et Rhizoma in clinic on MRP3 activity was verified using a self-constructed fluorescence screening system. The mRNA, protein expressions, and enzyme activity levels of NAD(P)H quinone dehydrogenase 1 (NQO1) and cytochrome P450 1A2 (CYP1A2) were measured in differentiated HepaRG cells. Hepatocyte toxicity after inhibition of AAI metabolite transport was detected using cell counting kit-8 assay. In vivo, C57BL/6 mice were randomly divided into 5 groups according to a random number table, including: control (1% sodium bicarbonate), AAI (10 mg/kg), stir-fried SAA (1.75 g/kg) and AAI + stir-fried SAA (1.75 and 8.75 g/kg) groups, 6 mice in each group. After 7 days of continuous gavage administration, liver and kidney damages were assessed, and the protein expressions and enzyme activity of liver metabolic enzymes NQO1 and CYP1A2 were determined simultaneously.
RESULTS:
In vivo, combination of 1.75 g/kg SAA and 10 mg/kg AAI suppressed AAI-induced nephrotoxicity and reduced dA-ALI formation by 26.7%, and these detoxification effects in a dose-dependent manner (P<0.01). Mechanistically, SAA inhibited MRP3 transport in vitro, downregulated NQO1 expression in vivo, increased CYP1A2 expression and enzymatic activity in vitro and in vivo, respectively (P<0.05 or P<0.01). Notably, SAA also reduced AAI-induced hepatotoxicity throughout the detoxification process, as indicated by a 41.3% reduction in the number of liver adducts (P<0.01).
CONCLUSIONS
Stir-fried SAA is a novel drug candidate for the suppression of AAI-induced liver and kidney damages. The protective mechanism may be closely related to the regulation of transporters and metabolic enzymes.
Aristolochic Acids/toxicity*
;
Animals
;
Humans
;
NAD(P)H Dehydrogenase (Quinone)/genetics*
;
HEK293 Cells
;
Kidney/pathology*
;
Cytochrome P-450 CYP1A2/genetics*
;
Mice, Inbred C57BL
;
DNA Adducts/drug effects*
;
Male
;
Kidney Diseases/drug therapy*
;
Drugs, Chinese Herbal/therapeutic use*
;
Mice
;
Prunus armeniaca
;
Plant Extracts
10.A novel arterial coupler with non-return snap-fit connection approach optimized arterial end-to-end anastomotic technique: An experimental study.
Hong-Bo GUO ; Mo-Fei WANG ; Ren-Qi YIN ; Kang-Kang ZHI
Chinese Journal of Traumatology 2025;28(1):13-21
PURPOSE:
Hand-sewn anastomosis as the gold standard of vascular anastomosis cannot fully meet the requirements of vascular anastomosis in speed and quality. Various vascular couplers have been developed to ameliorate this situation. Most of them are mainly used for venous anastomosis rather than arterial anastomosis. Although it is generally acknowledged that in almost all operations involving vascular reconstruction, it is the arteries that need to be anastomosed faster and more accurately and not the veins. A dedicated device is needed for creating arterial anastomosis in an easy, timesaving, less damaging but reliable procedure. Therefore, we plan to develop a novel arterial coupler device and test pre-clinical safety and effectiveness.
METHODS:
In this cohort study, the rationality of this novel arterial coupler was preliminarily tested by finite element analysis before it was manufactured. Several factors restrict the use of vascular couplers in arterial anastomosis, such as arterial eversion, fixation, etc. The manufactured arterial couplers underwent in vitro and in vivo experiments. In vitro, isolated arteries of beagles were anastomosed with the assistance of an arterial coupler, and the anastomosed arteries were evaluated through anti-traction tests. In animal experiments, the bilateral femoral arteries of 5 beagles served as a control group. After dissection, the femoral artery on one side was randomly selected to be anastomosed with a quick arterial coupler (QAC) (QAC group), and the femoral artery on the other side was anastomosed by the same person using an end-to-end suture technique with a 6-0 Prolene suture (suture group). The bilateral femoral arteries of 5 beagles were used for coupler-assisted anastomosis and hand-sewn anastomosis in vivo, respectively. Success rate, blood loss, anastomotic time, clamp time, total operation time, and patency rate were recorded. The patency of anastomosed arteries was assessed using vascular Doppler ultrasound, electromagnetic flowmeter, and pathological examination (6 weeks after surgery).
RESULTS:
As a novel arterial coupler, QAC was successfully designed and manufactured by using poly lactic-co-glycolic acid raw materials and 3-dimensions printing technology. Its rationality was preliminarily tested through finite element analysis and related mechanical analysis methods. The isolated arteries were successfully anastomosed with the assistance of QAC in vitro testing, which showed good anti-traction properties. In animal studies, QAC-assisted arterial anastomosis has superior profiles compared to hand-sewn anastomosis in anastomotic time (7.80 ± 1.41 vs. 16.38 ± 1.04 min), clamp time (8.80 ± 1.41 vs. 14.14 ± 1.57 min), and total operation time (46.64 ± 2.38 vs. 51.96 ± 3.65 min). The results of electromagnetic flowmeter, vascular Doppler ultrasound, and pathological examination showed that QAC-assisted anastomotic arteries were superior to hand-sewn arteries in terms of postoperative blood flow (16.86 ± 3.93 vs. 10.36 ± 0.92 mL/min) and vascular patency in 6 weeks after surgery.
CONCLUSION
QAC is a well-designed and easily maneuverable device specialized for end-to-end arterial anastomosis. Application of this device may decrease thermal ischemia time and improve the patency of anastomotic arteries, thus, improving outcomes.
Animals
;
Anastomosis, Surgical/instrumentation*
;
Dogs
;
Femoral Artery/surgery*
;
Vascular Surgical Procedures/instrumentation*
;
Finite Element Analysis

Result Analysis
Print
Save
E-mail