1. The ultrasonographic characteristics of fibrocystic breast change
Dong WEI ; Xueying LIN ; Yimi HE ; Ensheng XUE ; Liwu LIN
Chinese Journal of Ultrasonography 2019;28(10):897-900
Objective:
To investigate the ultrasonographic features of fibrocystic breast change (FBC) and improve the ultrasonographic diagnosis and differential diagnosis of FBC.
Methods:
Fifty-five patients of FBC with 60 lesions and 39 patients of invasive ductal carcinoma (IDC) with 42 lesions, which were confirmed by pathology after operation in the Affiliated Union Hospital of Fujian Medical University from January 2014 to February 2019 were enrolled. The preoperative sonographic findings of FBC and IDC were retrospectively analyzed and compared.
Results:
There was no significant difference between the two groups in the rates of showing irregular shape, which were 86.7% in FBC group and 88.1% in IDC group, respectively (
2.The ultrasonographic characteristics of fibrocystic breast change
Dong WEI ; Xueying LIN ; Yimi HE ; Ensheng XUE ; Liwu LIN
Chinese Journal of Ultrasonography 2019;28(10):897-900
Objective To investigate the ultrasonographic features of fibrocystic breast change ( FBC) and improve the ultrasonographic diagnosis and differential diagnosis of FBC . Methods Fifty‐five patients of FBC with 60 lesions and 39 patients of invasive ductal carcinoma ( IDC ) with 42 lesions ,which were confirmed by pathology after operation in the Affiliated Union Hospital of Fujian M edical University from January 2014 to February 2019 were enrolled . T he preoperative sonographic findings of FBC and IDC were retrospectively analyzed and compared . Results T here was no significant difference between the two groups in the rates of showing irregular shape ,which were 86 .7% in FBC group and 88 .1% in IDC group , respectively ( P >0 .05) ,but the rate of showing crab feet or burrs on the edge of lesions in FBC group was lower than that in IDC group( P <0 .05 ) . T he occurrence rates of posterior echo enhancement and cystic degeneration in FBC group were 81 .7% and 71 .7% respectively ,w hich were significantly higher than those in IDC group ( 38 .1% and 16 .7% ) ( P <0 .001) . In addition ,the FBC group showed fewer features such as hyperechoic halo and more features such as hypovascular supply than that of IDC group ( all P <0 .001 ) . Conclusions In terms of ultrasonic features ,including irregular shape or even crab feet and burrs ,FBC can be easily misdiagnosed as malignant tumors . However ,posterior echo enhancement ,interior scattered small cysts ,lack of blood supply and rare hyperechoic halo may be the characteristics of FBC ,w hich can be differentiated from malignant tumors .
3.Value of color Doppler ultrasonography in differential diagnosis of mammary ductal ectasia and breast cancer
Yanfang WANG ; Liwu LIN ; Ensheng XUE ; Liyun YU ; Meilian ZHANG ; Yimi HE
Chinese Journal of Ultrasonography 2018;27(5):411-416
Objective To investigate the value of color Doppler ultrasonography in mammary ductal ectasia( MDE). Methods Preoperative sonograms of 54 MDE,135 invasive ductal carcinoma( IDC) and 68 ductal carcinoma in situ ( DCIS ) patients were retrospectively analyzed and further confirmed by histopathology. Results MDE showed 88.9% (48/54) mass type and 11.1% (6/54) ductal type.The average age of patients in MDE was younger than that in IDC( P <0.05). The number of MDE located around the areola was more than that of IDC( P <0.05). Mean maximum diameter of MDE was smaller than that of DCIS ( P <0.05). Compared to DCIS and IDC,MDE in mass type showed higher detection rate of liquidity area and mammary ductal ectasia( all P <0.05),while lower detection rate of hyperecho, peripheral hyperechoic zone,posterior echo attenuation or blood flow richness( all P <0.001). Compared to IDC,MDE in mass type showed higher detection rate of inside ductal echolocation,while showed lower detection rate of irregular shape,spiculate margin or axillary lymph node enlargement. Compared to DCIS, MDE showed higher detection rate of large aspect ratios( ≥0.7). Less MDE in ductal type with hyperecho were found than DCIS in ductal type ( P < 0.001 ). The coincidence rate of ultrasonic diagnosis and postoperative histopathhology results in 54 MDE patientis was 13.0% ( 7/54 ). Conclusions The sonographic findings of MDE has diverse manifestations. It shows important value of ultrasonography for MDE in its diagnosis and differential diagnosis with breast cancer.
4.Relationship study between the features of conventional ultrasound & shear wave elasticity and axillary lymph node involvement in breast cancer
Jiawei ZHUO ; Yimi HE ; Meilian ZHANG ; Xu YE ; Ensheng XUE ; Liwu LIN
Chinese Journal of Ultrasonography 2018;27(8):709-713
Objective To investigate the correlation between the features of conventional ultrasound& shear wave elasticity and axillary lymph node involvement in breast cancer . Methods A total of 169 breast cancers patients were divided into lymph node metastasis group( n = 115) and non metastasis group ( n = 54 ) according to the postoperative pathological results . Preoperative conventional ultrasonographic features and preoperative shear wave elastography quantitative parameters ( E values ) of the two groups breast lessons were analyzed by single factor analysis to screen out statistically significant factors ,then Logistic regression analysis was performed to analyze the relationship between above factors and lymph node involvement . Results Single factor analysis showed the microcalcification and hyperechoic halo detection rates of lymph node metastasis group [ 81 .7% ( 94/115) and 71 .3% ( 82/115 ) ,respectively] were higher than those in non metastasis group [ 61 .1% (33/54) and 50 .0% ( 27/54) ,respectively] . The elastography maximum value( Emax) of lymph node involvement group was ( 182 .2 ± 74 .0) kPa ,which was larger than that in non metastasis group′s ( 153 .3 ± 76 .9) kPa ( P < 0 .05) . Multivariate Logistic regression analysis showed the microcalcification( OR = 2 .498 , P = 0 .022) ,the hyperechoic halo( OR = 2 .482 , P = 0 .013) and the Emax value( OR = 1 .007 , P = 0 .007) were risk factors of axillary lymph node metastasis in breast cancer . Conclusions Breast cancer with microcalcification ,hyperechoic signs and high Emax value is more likely to develop axillary lymph node metastasis .
5. The value of ultrasound-guided fine needle aspiration combined with detection of BRAF V600E in diagnosis of benign and malignant thyroid nodules
Zhijing LUO ; Ensheng XUE ; Liyun YU ; Yimi HE ; Wenjin LIN ; Qingfu QIAN ; Xiubin TANG
Chinese Journal of Ultrasonography 2018;27(6):500-504
Objective:
To evaluate the value of ultrasound-guided fine needle aspiration(US-FNA) combined with detection of BRAF V600E and thyroid imaging reporting and data system(TI-RADS) in diagnosis of benign and malignant thyroid nodules.
Methods:
In this study, 123 operative thyroid nodules from 114 patients who underwent US-FNA and detection of BRAF V600E were enrolled. TI-RADS was apply for the classification of each nodule before surgery. Specimens from each nodule were subjected for hematoxylin and eosin (HE) staining and cytological diagnosis and detection of BRAF V600E mutation.
Results:
①BRAF V600E mutation was found in 71 (71/123) nodules with histologic confirmation of papillary-thyroid carcinoma, 58 of which were cytologically diagnosed as carcinoma and 13 were indeterminate. Compared with the postoperative pathological results, US-FNA combined with BRAF V600E could improve the sensitivity and accuracy of diagnosis to thyroid nodules compared with individual US-FNA, and the difference was statistically significant(
6.Ultrasonic Characteristics of Complex Fibroadenoma of Breast and Its Differential Diagnosis from Invasive Ductal Carcinoma
Meilian ZHANG ; Hu CHEN ; Ensheng XUE ; Liwu LIN ; Yimi HE
Chinese Journal of Medical Imaging 2017;25(5):365-369
Purpose To explore ultrasonic characteristics of complex fibroadenoma (CF) of breast and its differential diagnosis from invasive ductal carcinoma (IDC).Materials and Methods Sixty-one patients with CF and 81 patients with IDC from January 2010 to February 2016 in the Affiliated Union Hospital of Fujian Medical University were enrolled,and the CF and IDC were confirmed by pathology after operation.The preoperative sonographic findings of CF and IDC were retrospectively analyzed and compared.Results Fifty-nine cases with CF were detected by ultrasonography in 61 cases.Ultrasonic findings of 59 cases of CF showed as follows:79.7% (47/59) of the CF cases with an aspect ratio <0.7;79.7% (47/59) with blood flow signal of 0 to 1 level;72.9% (43/59) with liquid dark area,including 67.8% (40/59) with round or oval cystic fluid area showing local sievelike or diffused distribution;72.9% (43/59) with irregular shape;61.0% (36/59) with obscure boundary;61.0% (36/59) with the largest diameter of tumor <2 cm;59.3% (35/59) with calcifications,including 33.9% (20/59) with coarse calcification,25.4% (15/59) with microcalcification and 85.7% (30/35) with distribution of calcified lesions along the linear high echo zone;54.2% (32/59) with echo heterogenicity showing linear high echo and high echo in the middle and low echo.There were significant differences in the detection rates of internal regular fluid area,internal linear high echo or high echo area,and alcification distribution along the linear high echo between CF and IDC lesions (all P<0.01).Compared with IDC,there were higher rates in CF for detecting lesions of largest diameter of tumor <2 cm,more regular shape,more clear border,poorer blood flow signal (P<0.05),but there were lower rates in CF for detecting axillary lymph node enlargement,lesions with edge or spiculation and hyperechoic halo (P<0.01).Conclusion Color Doppler ultrasonography is of great value in the diagnosis of CF and its differential diagnosis from IDC.
7.Analysis of ultrasonic diagnosis and misdiagnosis of breast fibroadenoma
Jiajia YANG ; Ensheng XUE ; Liwu LIN ; Yimi HE ; Qin YE
Chinese Journal of Medical Imaging Technology 2017;33(5):666-669
Objective To explore the atypical ultrasonic appearances of breast fibroadenoma and analyze the cause of mis diagnosis.Methods A total of 493 lesions in 485 patients of breast fibroadenoma detected by ultrasound examination andconfirmed by pathology were retrospectively analyzed.Atypical appearances were analyzed and misdiagnosis rate were cal-culated.Statistical methods were taken to compare the misdiagnosis rates in lesions with various atypical appearances andthose with none or single atypical appearance.Misdiagnosis rates in lesions with different sizes and pathological types wereanalyzed statically.Then misdiagnosing causes were analyzed.Results A total of 404 lesions were diagnosed correctly,in-cluding 99 lesions with atypical appearances,and the other 89 lesions were misdiagnosed,which showed atypical appear-ances.The misdiagnosis rate of lesions with ≥2 atypical features was higher than that with none or single atypical feature(x2 =256.40,P< 0.05).Large lesions (maximum diameter> 3 am) showed higher misdiagnosis rates than small ones(maximum diameter ≤3 cm,x2=6.73,P<0.05),and complex fibroadenoma lesions also showed higher misdiagnosisrate than simple ones (x2 =188.01,P<0.05).Conclusion The lesions with various atypical appearances,large size andcomplex fibroadenoma in pathology are easy to be misdiagnosed.
8.The differential diagnosis value of high frequency ultrasound in dorsal thyroid nodules
Qingyu LIU ; Ensheng XUE ; Yimi HE ; Wenjin LIN ; Yunlin HUANG ; Sufang ZHANG ; Zhijing LUO
Chinese Journal of Ultrasonography 2017;26(4):320-324
Objective To explore the value of high frequency ultrasound in differential diagnosis in dorsal thyroid (including gland dorsal or posterior) nodules.Methods Ultrasonographic features of 101 patients with ultrasonography suspected or misdiagnosed nodules in the dorsal area of the thyroid gland,which were then confirmed by pathology or hyaluronography/gastroscopy,were retrospectively analyzed.Ultrasonographic homogeneity (other nodules with similar ultrasonographic features were found in the ipsilateral gland),parenchyma homology (nodule parenchyma was continuous with glandular parenchyma) and blood homology (blood flow signals in nodules were continuous with those in glandular parenchyma) were applied as indicators for determinng thyroid nodules.Double-line sign or vascular arch sign at the edge of nodules served as an indicator for determining parathyroid nodules.Results Of the 101 cases,there were 46 thyroid nodules,35 parathyroid nodules,7 enlarged lymph nodes;6 esophageal diverticulum,6 esophageal cancer,1 cleft cyst.The determination of thyroid nodules by at least one of ultrasonographic homogeneity,parenchyma homology and blood homology showed sensitivity of 73.5 %,specificity of 96.5 % and accuracy of 85.8%.In the determination of parathyroid nodules by double-line sign or vascular arch sign at the edge of nodules,sensitivity,specificity and accuracy was 54.1%,85.5 % and 74.5 %,respectively.Conclusions Nodules in the dorsal area of the thyroid gland have different sources,and the understanding of corresponding characteristic ultrasonographic appearances is helpful for improving the differential diagnosis of these nodules.
9.The value of ultrasonic follow-up in diagnosis of benign and malignant thyroid nodules
Sufang ZHANG ; Ensheng XUE ; Yimi HE ; Qin YE ; Wenjin LIN ; Yunlin HUANG ; Qingfu QIAN
Chinese Journal of Ultrasonography 2016;25(7):579-583
Objective To analyze the changes of benign and malignant thyroid nodules during followup and to increase the diagnostic accuracy.Methods The ultrasonographic changes of 161 thyroid nodules confirmed by pathology were retrospectively analyzed,including size,internal components,echogenicity,margin,microcalcification,anteroposterior to transverse dimension ratio(A/T) and the relationships with thyroid capsule,and the change of cervical lymph nodes.Results Ninety-three benign thyroid nodules and 68 malignant thyroid nodules were enrolled in this study,the changes in size,internal components,microcalcification,the relationships with glandular capsule,and cervical lymph nodes were significantly different (P < 0.05),while the echogenicity,margin,and A/T were not significantly different,benign nodules changed more easily in size and internal components,while malignant nodules changed more easily in microcalcification.Both the nodules broken the thyroid capsule or cervical lymph nodes exhibited malignant signs suggest probable malignancy.Conclusions Analyzing the ultrasonographic changes during follow-up contributes to identify benign and malignant thyroid nodules.
10.The experimental study of the impact factors of real-time shear wave elastography
Yunlin HUANG ; Ensheng XUE ; Liyun YU ; Yimi HE ; Wenjin LIN ; Qingyu LIU ; Wenrong LIN
Chinese Journal of Ultrasonography 2016;25(12):1076-1080
Objective To investigate the impact factors of real-time shear wave elastography ( SWE) by using the ultrasound phantoms . Methods The noduled phantoms with different densities and viscosities and background phantoms with three textures ( soft ,medium ,and hard) were prepared by using gelatin as the main ingredient . Nodule phantoms were embedded in background phantom in different depths . The elasticity ( Emax ) was measured by SWE . Factorial designed was used to evaluate the effects of various factors ,including density ,viscosity and depth of nodule phantom and texture of background phantom on Emax of nodule phantom . Binary Logistic regression was used to analysis the effects of various factors , including density ,viscosity ,diameter ,depth of nodule phantom and texture of background phantom on the window phenomenon . Results The density ,viscosity and the Emax of nodule phantoms increased as the gelatin ratio increased . The Emax of nodule phantoms in shallow position ( depth < 3 .0 cm ) were higher than those in deep position ( depth ≥ 3 .0 cm) . In hard-background phantoms ,the Emax of nodule phantoms was maximal ,soft-background phantoms was minimal . Main effects of the density ,viscosity ,depth of nodule phantoms and texture of background phantoms on Emax of nodule phantoms were different ,and all of the factors had interactive effects ( P < 0 .05 ) . The density ,viscosity ,diameter and depth of nodule phantoms were independent risk factors of the windowphenomenon ( P < 0 .05 ) . According to OR ( 23 .846 ,0 .093 ,and 0 .003 ,respectively) ,reduced density and viscosity ,or increased diameter and depth of nodule phantoms ,could increase the incidence of the window phenomenon . Conclusions The density and viscosity of self-making ultrasound phantoms can be easily and flexibly controlled .Density ,viscosity , diameter ,depth of nodule and texture of background are the impact factors of shear wave elastography .

Result Analysis
Print
Save
E-mail