1.Application of Auto-prescription combined with low-dose contrast and iterative reconstruction algorithm in the CT angiography of thoracodorsal artery
Jian HE ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Deshuo DONG ; Zhiming MA ; Changyu DU
Journal of Practical Radiology 2025;41(5):861-865
Objective To explore the application value of Auto-prescription combined with low-dose contrast and adaptive statisti-cal iterative reconstruction-Veo(ASIR-V)algorithm in the computed tomography angiography(CTA)of thoracodorsal artery(TDA).Methods A total of 100 patients who underwent TDA CTA examination were prospectively selected.A tube voltage of 120 kVp and contrast agent of 1.5 mL/kg were used for group A(50 cases),and images were reconstructed with 40% post-set ASIR-V.The Auto-prescription for tube voltage and contrast agent of 1.2 mL/kg were used for group B(50 cases),while images were reconstruc-ted with 40%,60%,and 80% post-set ASIR-V,labeled as subgroups B1 to B3.The objective and subjective evaluation results of the images were compared between and within groups.Results Group A had an effective dose(ED)of 2.98(2.65,4.03)mSv,while group B had an ED of 1.92(1.44,3.33)mSv.The iodine intake in group B was lower than that in group A,and the CT value of the axillary artery in group B was significantly higher than that in group A(P<0.001).With the increased of ASIR-V level in group B,the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images gradually increased(P<0.05).In terms of subjec-tive scores on axial images,both subgroups B2 and B3 were superior to group A(P<0.001);with the increased of ASIR-V level in group B,subjective scores of axial images increased first and then decreased,among which subjective score of subgroup B2 was the highest and the differences were statistically significant(P<0.001).In terms of subjective scores on three-dimensional image quality,subgroups B1 to B3 were superior to group A(P<0.001).Conclusion The use of Auto-prescription combined with low-dose con-trast and 60% ASIR-V can significantly optimize the display of TDA,and reduce the radiation dose and contrast agent dose to a certain extent.
2.Effect of bundle intervention on reducing catheter-associated urinary tract infection
Tingyu LAN ; Hongwu HE ; Xing MING ; Qingqin LUO ; Ruiping LAI ; Kun MENG ; Yijun TANG ; Duoshuang XIE
Chinese Journal of Infection Control 2025;24(2):201-206
Objective To evaluate the effect of bundle intervention on reducing catheter-associated urinary tract in-fection(CAUTI).Methods Hospitalized patients with urinary catheterization in a tertiary first-class hospital were subjected to targeted monitoring of a baseline survey from January to December 2022(pre-intervention).The main causes were found out,and bundle intervention measures were developed and implemented through plan-do-check-act(PDCA)tools from January to March 2023(intervention period).The data from April to December 2023(post-intervention)were collected,difference in catheter use rate and incidence of CAUTI before and after intervention were compared.Results The implementation rate of correctly hanging urine collection bags after intervention was 97.00%,the implementation rate of timely emptying urine collection bags was 91.72%,awareness rate of hand hy-giene among patient's family members was 79.13%,implementation rate of urinary catheter clamping during trans-portation was 74.79%,and daily evaluation implementation rate was 87.68%,which were higher than the pre-in-tervention rates of 85.63%,80.47%,62.75%,60.00%,and 79.93%,respectively.The incidence of CAUTI de-creased from 1.23‰ before intervention to 0.57‰ after intervention,the use rate of urinary catheter decreased from 5.53%before intervention to 5.37%after intervention.Differences of the above indicators were all statistically sig-nificant(all P<0.05).Conclusion Through targeted monitoring on CAUTI and PDCA quality tools,the weak links in healthcare-associated infection control are identified,more targeted prevention and control measures are for-mulated,the implementation of bundle intervention measures can reduce the incidence of CAUTI.
3.The relationship between urinary arsenic methylation metabolic patterns and the transformation of skin keratinization and pigmentation abnormalities in population exposed to arsenic through drinking water
Xinye LI ; Zhiwei GUO ; Fan ZHAO ; Yuchen GUO ; Mengxin LI ; Lingling HE ; Zhen DI ; Wei SONG ; Kaiwen LIU ; Yu MA ; Yijun LIU ; Chang KONG ; Binggan WEI ; Zhongbing ZHANG
Chinese Journal of Endemiology 2025;44(6):439-444
Objective:To study the relationship between urinary arsenic methylation metabolism patterns and skin keratinization and pigmentation abnormalities in population exposed to arsenic through drinking water.Methods:Using a cross-sectional study method, a survey on endemic arsenic poisoning was conducted among permanent residents of drinking water endemic arsenic poisoning areas in Bayannur City, Inner Mongolia Autonomous Region in 2004 (before water improvement). In 2017 (after water improvement), 71 arsenic exposed individuals were followed up as survey subjects. According to the "Diagnosis of Endemic Arsenism" (WS/T 211-2015), the clinical grading of skin injuries (skin keratinization, pigmentation abnormalities) in the survey subjects was evaluated. Urine samples were collected for detection of arsenic methylation metabolite levels by high-performance liquid chromatography inductively coupled plasma mass spectrometry and calibrated with urinary creatinine. The changes and amplitudes of urinary arsenic methylation indicators before and after water improvement were calculated and analyzed according to the outcome of skin keratinization and pigmentation abnormalities which were divided into reduced, unchanged, and added groups.Results:(1) The changes in urinary total arsenic (TAs), inorganic arsenic (iAs), monomethyl arsenic (MMA), and dimethyl arsenic (DMA) levels in different outcome groups of skin keratinization were compared, and the differences were statistically significant ( H = 9.08, 8.77, 9.28, 8.57, P < 0.05). The changes in urinary TAs, iAs, MMA, DMA levels, iAs percentage (iAs%), DMA percentage (DMA%), and primary methylation index (PMI) in different outcome groups of skin pigmentation abnormalities were compared, and the differences were statistically significant ( H = 8.04, 10.67, 8.29, 9.14, 6.30, 9.10, 7.20, P < 0.05). (2) The comparison of amplitudes in urinary TAs, iAs, MMA, and DMA levels in different outcome groups of skin keratinization showed statistically significant differences ( H = 6.92, 7.34, 6.66, 6.16, P < 0.05). The amplitudes in urinary iAs level, iAs%, DMA%, and PMI in different outcome groups of skin pigmentation abnormalities were compared, and the differences were statistically significant ( H = 7.94, 7.61, 9.95, 7.22, P < 0.05). Conclusion:The changes pattern of urinary TAs, iAs, MMA, DMA, iAs%, DMA%, and PMI in population exposed to arsenic through drinking water is related to the transformation of skin keratinization and pigmentation abnormalities.
4.Performance of Computer-Aided Detection Software in Tuberculosis Case Finding in Township Health Centers in China
Xuefang CAO ; Boxuan FENG ; Bin ZHANG ; Dakuan WANG ; Jiang DU ; Yijun HE ; Tonglei GUO ; Shouguo PAN ; Zisen LIU ; Jiaoxia YAN ; Qi JIN ; Lei GAO ; Henan XIN
Chronic Diseases and Translational Medicine 2025;11(2):140-147
Background::Computer-aided detection (CAD) software has been introduced to automatically interpret digital chest X-rays. This study aimed to evaluate the performance of CAD software (JF CXR-1 v3.0, which was developed by a domestic Hi-tech enterprise) in tuberculosis (TB) case finding in China.Methods::In 2019, we conducted an internal evaluation of the performance of JF CXR-1 v3.0 by reading standard images annotated by a panel of experts. In 2020, using the reading results of chest X-rays by a panel of experts as the reference standard, we conducted an on-site prospective study to evaluate the performance of JF CXR-1 v3.0 and local radiologists in TB case finding in 13 township health centers in Zhongmu County, Henan Province.Results::Internal assessment results based on 277 standard images showed that JF CXR-1 v3.0 had a sensitivity of 85.94% (95% confidence interval [CI]: 77.42%, 94.45%) and a specificity of 74.65% (95% CI: 68.81%, 80.49%) to distinguish active TB from other imaging conditions. In the on-site evaluation phase, images from 3705 outpatients who underwent chest X-ray detection were read by JF CXR-1 v3.0 and local radiologists in parallel. The imaging diagnosis of local radiologists for active TB had a sensitivity of 32.89% (95% CI: 22.33%, 43.46%) and a specificity of 99.28% (95% CI: 99.01%, 99.56%), while JF CXR-1 v3.0 showed a significantly higher sensitivity of 92.11% (95% CI: 86.04%, 98.17%) ( p < 0.05) and maintained high specificity at 94.54% (95% CI: 93.81%, 95.28%). Conclusions::CAD software could play a positive role in improving the TB case finding capability of township health centers.
5.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.
6.Deep learning image reconstruction algorithm combined with a large reconstruction matrix for low-dose CT screening of lung nodules
Changyu DU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN ; Yijun LIU
Journal of Practical Radiology 2025;41(11):1886-1890
Objective To explore the application value of deep learning image reconstruction(DLIR)algorithm combined with a large reconstruction matrix in lung nodules screening using low-dose computed tomography(LDCT)of the chest.Methods Patients who underwent LDCT scans were prospectively enrolled.The control group(group A)used the iterative reconstruction(IR)algorithm(Karl)with a reconstruction level of Karl 5,reconstructed images of 512×512(group A1)matrix,and 1 024 × 1 024(group A2)matrix.The experimental group employed DLIR combined with 512×512(group B)matrix and 1 024 × 1 024(group C)matrix for image reconstruction at levels 1-5,which were recorded as groups B1-5 and groups C1-5.The CT values and standard deviation(SD)values of the lung parenchyma and tracheal air were measured,and the signal-to-noise ratio(SNR)was calculated.The overall lung image quality was scored on a Likert 5-point scale,and the subgroup with the best lung image quality was selected.The lung nodule detec-tion rate and clarity were compared with group A1.Results Under the same reconstruction matrix,the CT values of the tracheal air and lung parenchyma in the experimental group showed no significant difference compared to the control group,while the SD values were lower and SNR were higher(P<0.05).Within groups B and C,as the DLIR level increased,the SD values of the tracheal air and lung paren-chyma gradually decreased,and SNR gradually improved(P<0.05).Subjective scores for the image quality in groups B and C initially increased and then decreased,with group B3 and group C4 showed the best image quality.No difference was observed in objective eval-uation between the two groups,but the subjective image quality score of group C4 was superior to group B3(P<0.05).Subjective eval-uation of lung nodule display in group C4 was better than in group A1(P<0.05).Conclusion DLIR algorithm combined with a large reconstruction matrix is feasible for lung nodules screening in chest LDCT,reducing image noise while improving lung nodules clarity,demonstrating significant clinical value.
7.The feasibility of bone mineral density screening using a proximal femur radiomics model derived from abdomen-pelvic CT scans
Changyu DU ; Yijun LIU ; Shigeng WANG ; Xiaoyu TONG ; Yong FAN ; Wei WEI ; Anliang CHEN ; Jian HE
Journal of Practical Radiology 2025;41(2):310-314
Objective To develop an automated bone mineral density(BMD)assessment model based on proximal femur images from abdomen-pelvic CT scans and to analyze its application value in opportunistic osteoporosis(OP)screening.Methods A retrospective selection was conducted on 351 patients who underwent abdomen-pelvic plain CT examination.The patients were randomly divided into training set(n=245)and test set(n=106)in a ratio of 7∶3.All images were transferred to a quantitative computed tomography(QCT)post-processing workstation to measure the BMD of the left proximal femur.According to the QCT BMD T-score,the patients were divided into osteoporosis(T-score-2.5),osteopenia(-2.5<T-score<-1)and normal bone density(T-score≥-1).The left proximal femur was dissected using an automatic segmentation model,and two three-class BMD assessment radiomics models were constructed using random forest(RF)and logistic regression(LR)classifiers,respectively.The receiver operating characteristic(ROC)curves were generated,and the area under the curve(AUC),sensitivity,specificity and other metrics were calculated to evaluate the diagnostic performance of the two models.The DeLong test was used to compare differences between the models.Results In the test set,the AUC of the RF and LR models for identifying osteoporosis were 0.953 and 0.954,respectively.The AUC for identifying osteopenia were 0.894 and 0.870,and the AUC for identifying normal bone density were 0.975 and 0.982,respectively.The comparison of model performance showed no statistically significant differences between the RF and LR models in identifying the three bone states in both the training and test sets(P>0.05).Conclusion Both the RF and LR radiomics models,constructed based on abdomen-pelvic plain CT scans,can be used for opportunistic BMD screening with high diagnostic efficiency.
8.Reasonable management and control practice of prophylactic use of antibiotics in urinary system lithotripsy
Yijun CHEN ; Zhuo WANG ; Miao HE ; Yu ZHANG ; Jing TIAN
Journal of Pharmaceutical Practice and Service 2025;43(12):614-618
Objective To analyze the effectiveness of reasonable control measures for prophylactic use of antibiotics in urinary system lithotripsy. Methods By antimicrobial stewardship, strengthening special comments on antibiotics and information notification on rational use of antibiotics, adding and improving the pre-review rules for antibiotics prescriptions, conducting in-depth clinical training and consultation by clinical pharmacists, strengthening innovation in rational use of drugs, and taking various measures to actively improve rational use of prophylactic antibiotics of lithotripsy in urology department, the changes of indexes related to antibiotics in urology department from 2019 to 2022 were analyzed. Results After active and reasonable control, Antibiotics Use Density in urology department decreased year by year. The utilization rate of antibiotics in inpatients decreased from 94.27% in 2019 to 77.47% in 2022. Various rate of microbial inspection reached the standard in 2022. The imipenem and cilastatin sodium for injection ranking of prophylactic use of antibiotics consumption DDDs for urinary system lithotripsy decreased from the 4th place in 2019 to the 8th place in 2022. The ranking of the urology department on carbapenem consumption DDDs in the whole hospital decreased from the 8th place in 2019 to the 12th place in 2022. At the same time, the incidence of urinary tract lithotripsy postoperative infection showed a decreasing trend year by year, from 0.84% in 2019 to 0.49% in 2022. Conclusion Positive control measures can promote the rational use of prophylactic antibiotics for urinary system lithotripsy.
9.Efficacy of endoscopic ultrasound-guided paraesophageal varices puncture cyanoacrylate selective seal for liver cirrhosis complicated with esophageal varices (with video)
Lingling HE ; Yijun LIN ; Xiaohui YE ; Lu ZHU ; Ping LI
Chinese Journal of Digestive Endoscopy 2025;42(7):565-568
Objective:To investigate the efficacy of endoscopic ultrasound-guided paraesophageal varices puncture cyanoacrylate selective seal for liver cirrhosis complicated with esophageal varices.Methods:Data of 86 patients with liver cirrhosis complicated with esophageal varices undergoing endoscopic ultrasound-guided paraesophageal varices puncture cyanoacrylate selective seal (the treatment group, n=40) and conventional endoscopic tissue glue injection treatment (the control group, n=46) were retrospectively collected from Beijing Ditan Hospital from January 2023 to October 2023. The reduced percentage of severe varicose veins, the amount of tissue glue used during operation, the number of punctures and the rate of rebleeding in six months were compared. Results:There were no significant differences in the baseline data including gender, age, blood routine index, liver and kidney functions, proportion of severity varicose veins between the two groups ( P>0.05). In the treatment group, severe varicose veins accounted for 90.0% (36/40) before treatment while it was 12.5% (5/40) after the treatment, and the proportion of severe varicose veins decreased by 77.5%. In the control group, the proportion of severe varicose veins was 89.1% (41/46) before while it was 43.5% (20/46) after the treatment, and the proportion of severe varicose veins decreased by 45.6%. The proportion of severe varicose veins decreased more in the treatment group than that in the control group ( χ2=13.86, P<0.001). Compared with the control group, the median amount of tissue glue applied in the treatment group was significantly less (2.5 mL VS 3.0 mL, Z=-3.55, P<0.001), and the median number of punctures was also significantly less (2 VS 6, Z=-7.10, P<0.001). There was no significant difference in the rate of rebleeding within six months after the treatment between the two groups [12.5% (5/40) VS 10.9% (5/46), χ2=0.06, P=0.814]. Conclusion:For patients with cirrhosis complicated with esophageal varices, endoscopic ultrasound-guided paraesophageal varices puncture cyanoacrylate selective seal demonstrates superior efficacy over conventional endoscopic treatment, with less tissue glue applied, which is worth of promotion and application in clinical practice.
10.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.

Result Analysis
Print
Save
E-mail