1.Three-Dimensional Finite Element Analysis of Implant-Supported Overdenture with Lingual Metal-Reinforced Bar
Xinyue ZHANG ; Yong WANG ; Qian CHEN ; Tuanfeng ZHOU ; Kenan MA ; Zixuan WANG ; Yijiao ZHAO
Journal of Medical Biomechanics 2024;39(3):532-538
Objective To investigate the biomechanical effects of lingual metal-reinforced denture bases on edentulous implant-supported prostheses by three-dimensional finite element analysis,and provide references for the treatment of edentulous jaws.Methods Two implant-supported Locator-type overdenture models with lingual metal-reinforced and non-reinforced denture bases were constructed.A 150 N vertical load on the fovea of the posterior teeth,a 150 N oblique load on the fovea of the posterior teeth,and a 150 N vertical load on the anterior teeth were applied to simulate the centric occlusion,left and right lateral chewing,and anterior teeth cutting,and stresses on the tissues of two models were analyzed.Results When the posterior and anterior teeth were loaded vertically,the stress distribution on each organization was similar between the two denture base designs.The maximum stress difference was between 0 and 0.16 MPa.Under unilateral masticatory chewing,the range of stress concentration on denture base,implant and mucoperiosteum,and the maximum stress of the implant and peri-implant bone without metal reinforcement were significantly greater than those with metal reinforcement,and the maximum stress difference was between 0.59 MPa and 2.99 MPa.Conclusions Lingual metal-reinforced denture base can play a role in stress dispersion,or reduce the risk of bone resorption and denture base fracture to a certain extent.
2.Expert consensus on the workflow of digital aesthetic design in prosthodontics
Zhonghao LIU ; Feng LIU ; Jiang CHEN ; Cui HUANG ; Xianglong HAN ; Wenjie HU ; Chun XU ; Weicai LIU ; Lina NIU ; Chufan MA ; Yijiao ZHAO ; Ke ZHAO ; Ming ZHENG ; Yaming CHEN ; Qingfeng HUANG ; Yi MAN ; Mingming XU ; Xuliang DENG ; Ti ZHOU ; Xiaorui SHI
Journal of Practical Stomatology 2024;40(2):156-163
In the field of dental aesthetics,digital aesthetic design plays a crucial role in helping dentists to predict treatment outcomes vis-ually,as well as in enhancing the consistency of knowledge and understanding of aesthetic goals between dentists and patients.It serves as the foundation for achieving ideal aesthetic effects.However,there is no clear standard for this digital process currently in China and abroad.Many dentists lack of systematic understanding of how to carry out digital aesthetic design for treatment.To establish standardized processes for dental aesthetic design and to improve the homogeneity of treatment outcomes,Chinese Society of Digital Dental Industry(CSD-DI)convened domestic experts in related field to compile this consensus.This article elaborates on the key aspects of digital aesthetic data collection,integration steps,and the digital aesthetic design process.It also formulates a decision tree for dental aesthetics at macro level and outlines corresponding workflows for various clinical scenarios,serving as a reference for clinicians.
3.Exploration and innovative application of digital technology in pediatric dentistry
Yijiao ZHAO ; Xiaoxian CHEN ; Jun WANG ; Yong WANG
Chinese Journal of Stomatology 2024;59(11):1080-1087
Pediatric dentistry treats patients aged 0-18 years, encompassing the characteristics of general dentistry. The clinical techniques are closely related to restorative dentistry, endodontics, orthodontics, and maxillofacial surgery, while also possessing unique aspects. It particularly focuses on the growth and development patterns of children′s dentition and maxillofacial structures. Currently, digital technology has deeply integrated with various clinical disciplines of dentistry, and pediatric dentistry has made significant progress with pediatric-specific digital applications. On one hand, the introduction of mature digital technologies is enabling the digital transformation of pediatric dental treatment models; on the other hand, there is innovative development of new digital technologies tailored to the specific needs of pediatric dental care, filling gaps in the field. Based on years of research in digital technology for pediatric dentistry, our team details the current innovative applications and scientific explorations in this area from these two perspectives. Additionally, we anticipate the potential expansion of digital technologies not yet applied in pediatric dentistry, providing a reference for clinical scholars in the field to conduct exploratory research.
4.Chairside digital design and manufacturing method for children's band and loop space maintainers
Qingzhao QIN ; Jia HU ; Xiaoxian CHEN ; Bingqing SHI ; Zixiang GAO ; Yujia ZHU ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2024;42(2):234-241
Objective This study proposes a chairside digital design and manufacturing method for band and loop space maintainers and preliminarily validates its clinical feasibility.Methods Clinical cases of 10 children requiring space maintenance caused by premature loss of primary teeth were collected.Intraoral scan data of the affected children were also collected to establish digital models of the missing teeth.Using a pediatric band and loop space maintainer de-sign software developed by our research team,a rapid personalized design of band and loop structures was achieved,and a digital model of an integrated band and loop space maintainer was ultimately generated.A chairside space maintainer was manufactured through metal computer numerical control machining for the experimental group,whereas metal 3D printing in the dental laboratory was used for the control group.A model fitting assessment was conducted for the space maintainers of both groups,and senior pediatric dental experts were invited to evaluate the clinical feasibility of the space maintainers with regard to fit and stability using the visual analogue scale scoring system.Statistical analysis was also performed.Results The time spent in designing and manufacturing the 10 space maintainers of the experimental group was all less than 1 h.Statistical analysis of expert ratings showed that the experimental group outperformed the control group with regard to fit and stability.Both types of space maintainers met clinical requirements.Conclusion The chairside digital design and manufacturing method for pediatric band and loop space maintainers proposed in this study can achieve same-day fitting of space maintainers at the first appointment,demonstrating good clinical feasibility and significant potential for clinical application.
5.Deep learning-assisted construction of three-dimensional face midsagittal plane based on point clouds
Yujia ZHU ; Zhenguang LIU ; Aonan WEN ; Zixiang GAO ; Qingzhao QIN ; Xiangling FU ; Yong WANG ; Jinpeng CHEN ; Yijiao ZHAO
Chinese Journal of Stomatology 2023;58(11):1178-1183
Objective:To establish an intelligent registration algorithm under the framework of original-mirror alignment algorithm to construct three-dimensional (3D) facial midsagittal plane automatically. Dynamic Graph Registration Network (DGRNet) was established to realize the intelligent registration, in order to provide a reference for clinical digital design and analysis.Methods:Two hundred clinical patients without significant facial deformities were collected from October 2020 to October 2022 at Peking University School and Hospital of Stomatology. The DGRNet consists of constructing the feature vectors of key points in point original and mirror point clouds (X, Y), obtaining the correspondence of key points, and calculating the rotation and translation by singular value decomposition. Original and mirror point clouds were registrated and united. The principal component analysis (PCA) algorithm was used to obtain the DGRNet alignment midsagittal plane. The model was evaluated based on the coefficient of determination (R 2) index for the translation and rotation matrix of test set. The angle error was evaluated on the 3D facial midsagittal plane constructed by the DGRNet alignment midsagittal plane and the iterative closet point (ICP) alignment midsagittal plane for 50 cases of clinical facial data. Results:The average angle error of the DGRNet alignment midsagittal plane and ICP alignment midsagittal plane was 1.05°±0.56°, and the minimum angle error was only 0.13°. The successful detection rate was 78% (39/50) within 1.50° and 90% (45/50) within 2.00°.Conclusions:This study proposes a new solution for the construction of 3D facial midsagittal plane based on the DGRNet alignment method with intelligent registration, which can improve the efficiency and effectiveness of treatment to some extent.
6.Study of sequential surgical guide assisting full arch immediate implant placement and provisionalization in patients with severe periodontitis
Jingwen YANG ; Jianxia HOU ; Jianzhang LIU ; Yu ZHANG ; Quan CHEN ; Yijiao ZHAO ; Yong WANG
Chinese Journal of Stomatology 2021;56(6):576-580
To explore the technical process and the therapeutic effect of using sequential surgical guide with independent intellectual property rights assisting immediate implantation and restoration of the full arch, with the support from the periodontal splint for mobile supporting teeth, patients with severe periodontitis who planned to undergo immediate full arch implantation were recruited from August 2019 to December 2020 at the Department of Prosthodontics, Department of Periodontology, Department of Implantology and First Clinical Division, Peking University School and Hospital of Stomatology. Through the procedure of collecting preoperative maxillofacial data, making systematic diagnostic design, making periodontal splints fixation, producing surgical guide, and carrying out guided surgery for full arch immediate implantation, eight cases were included. By registering the postoperative cone-beam CT (CBCT) with the preoperative data, the difference between the actual three-dimensional position of the implants and the virtual design was observed, and the accuracy of the implant placement position guided by the sequential guide was statistically analyzed using SPSS 25.0 software. Analysis indicators include coronal and apical global displacement, coronal horizontal and vertical displacement, apical horizontal and vertical displacement, and angular deviation. Results revealed that the 8 patients [2 males and 6 females, aged (49.0±9.3) years (38-65 years)] of recruited cases included 7 cases of maxilla and 1 cases of mandible. A total of 48 implants, of which 44 implants were placed upright and 4 were placed tilted, 16 implants in the anterior region and 32 implants in the posterior region. No guide plate fracture or damage to important anatomical structures were reported. The overall displacement at the coronal point [(0.83±0.48) mm] and the global displacement at the apical point [(1.36±0.57) mm] were within the clinically acceptable safety range, and the horizontal displacement and vertical displacement at the coronal point, horizontal displacement and vertical displacement at the apical point, and the angle deviation of implants axial have no statistic significant difference in the anterior and posterior region ( P>0.05). Periodontal splints combined with sequential surgical guides to assist patients with severe periodontitis for immediate full arch implantation and immediate restoration can expand the indications of guide assisted implant surgery. It meets the safety requirements in clinical applications.
7.Clinical experience of high-flow nasal cannula oxygen therapy in severe COVID-19 patients.
Guojun HE ; Yijiao HAN ; Qiang FANG ; Jianying ZHOU ; Jifang SHEN ; Tong LI ; Qibin PU ; Aijun CHEN ; Zhiyang QI ; Lijun SUN ; Hongliu CAI
Journal of Zhejiang University. Medical sciences 2020;49(2):232-239
Acute respiratory failure due to acute hypoxemia is the major manifestation in severe coronavirus disease 2019 (COVID-19). Rational and effective respiratory support is crucial in the management of COVID-19 patients. High-flow nasal cannula (HFNC) has been utilized widely due to its superiority over other non-invasive respiratory support techniques. To avoid HFNC failure and intubation delay, the key issues are proper patients, timely application and improving compliance. It should be noted that elder patients are vulnerable for failed HFNC. We applied HFNC for oxygen therapy in severe and critical ill COVID-19 patients and summarized the following experiences. Firstly, to select the proper size of nasal catheter, to locate it at suitable place, and to confirm the nose and the upper respiratory airway unobstructed. Secondly, an initial ow of 60 L/min and 37℃ should be given immediately for patients with obvious respiratory distress or weak cough ability; otherwise, low-level support should be given first and the level gradually increased. Thirdly, to avoid hypoxia or hypoxemia, the treatment goal of HFNC should be maintained the oxygen saturation (SpO) above 95% for patients without chronic pulmonary disease. Finally, patients should wear a surgical mask during HFNC treatment to reduce the risk of virus transmission through droplets or aerosols.
Aged
;
Betacoronavirus
;
isolation & purification
;
Cannula
;
Coronavirus Infections
;
therapy
;
Humans
;
Oxygen
;
administration & dosage
;
Pandemics
;
Pneumonia, Viral
;
therapy
8.Clinical experience of high-flow nasal cannula oxygen therapy in severe corona virus disease 2019 (COVID-19) patients.
Guojun HE ; Yijiao HAN ; Qiang FANG ; Jianying ZHOU ; Jifang SHEN ; Tong LI ; Qibin PU ; Aijun CHEN ; Zhiyang QI ; Lijun SUN ; Hongliu CAI
Journal of Zhejiang University. Medical sciences 2020;49(1):232-239
Acute respiratory failure due to acute hypoxemia is the major manifestation in severe coronavirus disease 2019 (COVID-19) induced by severe acute respiratory syndrome coronavirus 2 infection. Rational and effective respiratory support is crucial in the management of COVID-19 patients. High-flow nasal cannula (HFNC) has been utilized widely due to its superiority over other non-invasive respiratory support techniques. To avoid HFNC failure and intubation delay, the key issues are proper patients, timely application and improving compliance. It should be noted that elder patients are vulnerable for failed HFNC. We applied HFNC for oxygen therapy in severe and critical COVID-19 patients and summarized the following experiences. Firstly, to select the proper size of nasal catheter, to locate it at suitable place, and to confirm the nose and the upper respiratory airway unobstructed. Secondly, an initial flow of 60 L/min and 37℃ should be given immediately for patients with obvious respiratory distress or weak cough ability; otherwise, low-level support should be given first and the level gradually increased. Thirdly, to avoid hypoxia or hypoxemia, the treatment goal of HFNC should be maintained the oxygen saturation (SpO) above 95% for patients without chronic pulmonary disease. Finally, patients should wear a surgical mask during HFNC treatment to reduce the risk of virus transmission through droplets or aerosols.
Aged
;
Betacoronavirus
;
Cannula
;
Coronavirus Infections
;
complications
;
therapy
;
Humans
;
Hypoxia
;
etiology
;
prevention & control
;
therapy
;
Masks
;
Oxygen
;
administration & dosage
;
Oxygen Inhalation Therapy
;
instrumentation
;
standards
;
Pandemics
;
Pneumonia, Viral
;
complications
;
therapy
9.Research and development of clinical application accuracy of intraoral three-dimensional scanning technology
Yue CAO ; Junkai CHEN ; Yijiao ZHAO ; Yong WANG ; Yuchun SUN
Chinese Journal of Stomatology 2020;55(3):201-205
Intraoral three-dimensional scanning technology has been adopted in stomatology field and developed rapidly with improved accuracy. At present, the scanning accuracy of the intraoral three-dimensional scanners used in restoration of single crown, three unit fixed partial bridge and single implant crown satisfies the clinical requirements. While for restoration of multi-unit fixed, the scanning accuracy is not enough. There are still technical bottlenecks for scanning functional motion boundary of soft tissue, especially for direct acquisition of edentulous functional impressions. Through literature review and analysis, we summarize the intraoral scanning accuracy of oral hard and soft tissues, and analyze the clinical applicability and limitations of intraoral scanning technology, providing reference for clinical application.
10.Exploration and innovation of training management mode for stomatology digital technology national engineering laboratory
Yijiao ZHAO ; Xinyue ZHANG ; Hu CHEN ; Huifang YANG ; Jianjiang ZHAO ; Yong WANG
Chinese Journal of Medical Science Research Management 2018;31(5):395-399
Objective This paper aimed at the management needs of the digital technique research-type laboratory of stomatology to explore a "three-stage training management" mode under the concept of "Standard Operating Procedures" (SOP) to improve the traditional training model for laboratory.Methods Experimental technology training management is an important step to insure the safely running of college research-type laboratory.Digital oral medical experimental technique is a kind of new technique developed in recent years,it is one of the important technical means of oral medical research today.In this paper,we based on the scientific research service demand of digital technique research-type laboratory in oral medical colleges explored and established a kind of three-stage training management mode under the concept of "Standard Operating Procedures".This training management mode included network self-study training,laboratory practical training and regular self-study training.Results The SOP training management model has achieved a good preliminary application effect in Peking University School and Hospital of Stomatology.Conclusions The training management model established in this study could improve the traditional training model and provide a theoretical support and experience for the domestic oral medical colleges.

Result Analysis
Print
Save
E-mail