1.Characteristic volatile organic compounds in exhaled breath of coal workers' pneumoconiosis patients by thermal desorption gas chromatography-mass spectrometry
Yazhen HE ; Chunguang DING ; Junyun WANG ; Yuzhen FENG ; Fangda PENG ; Gaisheng LIU ; Fan YANG ; Chunmin ZHANG ; Rui GAO ; Qingyu MENG ; Zhijun WU ; Jingguang FAN
Journal of Environmental and Occupational Medicine 2025;42(5):571-577
Background Coal workers' pneumoconiosis is a serious occupational disease in China. Exhaled volatile organic compounds (VOCs) can serve as the "breath fingerprint" of internal pathological processes, which provides a theoretical basis for exhaled VOCs to be used as potential non-invasive biomarkers for early diagnosis of coal workers' pneumoconiosis. Objective To screen out the characteristic VOCs and important characteristic VOCs of exhaled air in patients with coal workers' pneumoconiosis, and to explore the potential of these VOCs as biomarkers for early non-invasive diagnosis of the disease. Methods In this study, 27 VOCs in the exhaled breath of 22 patients with stage I coal workers' pneumoconiosis, 77 workers exposed to dust, and 92 healthy controls were quantitatively detected by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS). Substances with P<0.05 in univariate analysis and variable importance projection (VIP) >1 in supervised orthogonal partial least squares discriminant analysis (OPLS-DA) model were selected as the characteristic VOCs for early diagnosis of coal workers' pneumoconiosis. Age was included in the LASSO regression model as a covariate to screen out important characteristic VOCs, and the diagnostic performance was evaluated by receiver operating characteristic (ROC) curve. Spearman correlation was further used to explore the correlation between important characteristic VOCs and clinical lung function indicators. Results Through univariate analysis and OPLS-DA modeling, 8 VOCs were selected, including 2-methylpentane, 3-methylpentane, n-hexane, methylcyclopentane, n-heptane, methylcyclohexane, 4-methyl-2-pentanone, and 2-hexanone, in exhaled breath of patients with coal workers' pneumoconiosis. The concentrations of 4 VOCs, including 3-methylpentane, n-hexane, 4-methyl-2-pentanone, and 2-hexanone, showed a decreasing trend with the increase of dust exposure years. By LASSO regression, the important characteristic VOCs of the coal workers' pneumoconiosis group and the dust exposure group were n-hexane, methylcyclohexane and 4-methyl-2-pentanone, and the important characteristic VOCs of the coal workers' pneumoconiosis group and the healthy group were 2-methyl-pentane and 4-methyl-2-pentanone. The ROC analysis showed that the area under the curve (AUC) of n-hexane, methylcyclohexane, and 4-methyl-2-pentanone were 0.969, 0.909, and 0.956, respectively, and the AUC of combined diagnosis was 0.988 and its Youden index was 0.961, suggesting that these results can serve as a valuable reference for further research on early diagnosis. The Correlation analysis found that there was a positive correlation between n-hexane and lung function indicators in the important characteristic VOCs, indicating that it could indirectly reflect the obstruction of lung function ventilation, further proving that important characteristic VOCs have the potential to monitor lung function decline. Conclusion Three important characteristic VOCs selected in this study have the potential to be used as non-invasive biomarkers for early diagnosis and disease monitoring of coal workers' pneumoconiosis, and are worthy of further study and verification.
2.Liquid biopsy in hepatocellular carcinoma: Challenges, advances, and clinical implications
Jaeho PARK ; Yi-Te LEE ; Vatche G. AGOPIAN ; Jessica S LIU ; Ekaterina K. KOLTSOVA ; Sungyong YOU ; Yazhen ZHU ; Hsian-Rong TSENG ; Ju Dong YANG
Clinical and Molecular Hepatology 2025;31(Suppl):S255-S284
Hepatocellular carcinoma (HCC) is an aggressive primary liver malignancy often diagnosed at an advanced stage, resulting in a poor prognosis. Accurate risk stratification and early detection of HCC are critical unmet needs for improving outcomes. Several blood-based biomarkers and imaging tests are available for early detection, prediction, and monitoring of HCC. However, serum protein biomarkers such as alpha-fetoprotein have shown relatively low sensitivity, leading to inaccurate performance. Imaging studies also face limitations related to suboptimal accuracy, high cost, and limited implementation. Recently, liquid biopsy techniques have gained attention for addressing these unmet needs. Liquid biopsy is non-invasive and provides more objective readouts, requiring less reliance on healthcare professional’s skills compared to imaging. Circulating tumor cells, cell-free DNA, and extracellular vesicles are targeted in liquid biopsies as novel biomarkers for HCC. Despite their potential, there are debates regarding the role of these novel biomarkers in the HCC care continuum. This review article aims to discuss the technical challenges, recent technical advancements, advantages and disadvantages of these liquid biopsies, as well as their current clinical application and future directions of liquid biopsy in HCC.
3.Construction and clinical validation of a machine learning-based nomogram model for predicting lymphatic leakage following radical prostatectomy
Xiudong YANG ; Xing LIU ; Xin LIU ; Yan JIANG ; Wei WANG ; Zongbin HE ; Sha HUANG ; Meihong WEN ; Yazhen LIU
The Journal of Practical Medicine 2025;41(21):3378-3384
Objective To identify risk factors associated with lymphatic leakage after laparoscopic radical prostatectomy(LRP)and to develop a machine learning-based nomogram for predicting such outcomes to support clinical prevention strategies.Methods We retrospectively analyzed perioperative data from 248 patients who underwent radical prostatectomy for prostate cancer between January 2020 and January 2024.Independent risk factors were identified through univariate and multivariate logistic regression analyses.A predictive model was developed,and its diagnostic performance was assessed by the area under the receiver operating characteristic curve(AUC).Five-fold cross-validation was performed to evaluate the model's generalizability.A nomogram was subsequently constructed to facilitate individualized risk quantification.Results Among the 248 patients,89(35.9%)developed lymphatic leakage,while 159(64.1%)did not.Independent risk factors for lymphatic leakage included intraopera-tive lymph node dissection(OR=5.415,95%CI:2.167~13.532,P<0.001),intraoperative plasma transfusion(OR=2.952,95%CI:1.524~5.718,P=0.001),and postoperative fasting duration of≥2 days(OR=1.412,95%CI:1.089~1.829,P=0.009).The predictive model showed good discrimination and calibration(AUC=0.711,95%CI:0.647~0.776,P<0.001;sensitivity:0.764;specificity:0.597).Model robustness was confirmed through five-fold cross-validation(training set AUC=0.822;test set AUC=0.829).The nomogram provided a clinically useful tool for quantifying individual risk of lymphatic leakage.Conclusions Intraoperative lymph node dissection,plasma transfusion,and postoperative fasting lasting≥2 days are independent risk factors for lymphatic leakage following radical prostatectomy.The validated predictive model demonstrates favorable clinical utility.
4.Construction and clinical validation of a machine learning-based nomogram model for predicting lymphatic leakage following radical prostatectomy
Xiudong YANG ; Xing LIU ; Xin LIU ; Yan JIANG ; Wei WANG ; Zongbin HE ; Sha HUANG ; Meihong WEN ; Yazhen LIU
The Journal of Practical Medicine 2025;41(21):3378-3384
Objective To identify risk factors associated with lymphatic leakage after laparoscopic radical prostatectomy(LRP)and to develop a machine learning-based nomogram for predicting such outcomes to support clinical prevention strategies.Methods We retrospectively analyzed perioperative data from 248 patients who underwent radical prostatectomy for prostate cancer between January 2020 and January 2024.Independent risk factors were identified through univariate and multivariate logistic regression analyses.A predictive model was developed,and its diagnostic performance was assessed by the area under the receiver operating characteristic curve(AUC).Five-fold cross-validation was performed to evaluate the model's generalizability.A nomogram was subsequently constructed to facilitate individualized risk quantification.Results Among the 248 patients,89(35.9%)developed lymphatic leakage,while 159(64.1%)did not.Independent risk factors for lymphatic leakage included intraopera-tive lymph node dissection(OR=5.415,95%CI:2.167~13.532,P<0.001),intraoperative plasma transfusion(OR=2.952,95%CI:1.524~5.718,P=0.001),and postoperative fasting duration of≥2 days(OR=1.412,95%CI:1.089~1.829,P=0.009).The predictive model showed good discrimination and calibration(AUC=0.711,95%CI:0.647~0.776,P<0.001;sensitivity:0.764;specificity:0.597).Model robustness was confirmed through five-fold cross-validation(training set AUC=0.822;test set AUC=0.829).The nomogram provided a clinically useful tool for quantifying individual risk of lymphatic leakage.Conclusions Intraoperative lymph node dissection,plasma transfusion,and postoperative fasting lasting≥2 days are independent risk factors for lymphatic leakage following radical prostatectomy.The validated predictive model demonstrates favorable clinical utility.
5.Liquid biopsy in hepatocellular carcinoma: Challenges, advances, and clinical implications
Jaeho PARK ; Yi-Te LEE ; Vatche G. AGOPIAN ; Jessica S LIU ; Ekaterina K. KOLTSOVA ; Sungyong YOU ; Yazhen ZHU ; Hsian-Rong TSENG ; Ju Dong YANG
Clinical and Molecular Hepatology 2025;31(Suppl):S255-S284
Hepatocellular carcinoma (HCC) is an aggressive primary liver malignancy often diagnosed at an advanced stage, resulting in a poor prognosis. Accurate risk stratification and early detection of HCC are critical unmet needs for improving outcomes. Several blood-based biomarkers and imaging tests are available for early detection, prediction, and monitoring of HCC. However, serum protein biomarkers such as alpha-fetoprotein have shown relatively low sensitivity, leading to inaccurate performance. Imaging studies also face limitations related to suboptimal accuracy, high cost, and limited implementation. Recently, liquid biopsy techniques have gained attention for addressing these unmet needs. Liquid biopsy is non-invasive and provides more objective readouts, requiring less reliance on healthcare professional’s skills compared to imaging. Circulating tumor cells, cell-free DNA, and extracellular vesicles are targeted in liquid biopsies as novel biomarkers for HCC. Despite their potential, there are debates regarding the role of these novel biomarkers in the HCC care continuum. This review article aims to discuss the technical challenges, recent technical advancements, advantages and disadvantages of these liquid biopsies, as well as their current clinical application and future directions of liquid biopsy in HCC.
6.Liquid biopsy in hepatocellular carcinoma: Challenges, advances, and clinical implications
Jaeho PARK ; Yi-Te LEE ; Vatche G. AGOPIAN ; Jessica S LIU ; Ekaterina K. KOLTSOVA ; Sungyong YOU ; Yazhen ZHU ; Hsian-Rong TSENG ; Ju Dong YANG
Clinical and Molecular Hepatology 2025;31(Suppl):S255-S284
Hepatocellular carcinoma (HCC) is an aggressive primary liver malignancy often diagnosed at an advanced stage, resulting in a poor prognosis. Accurate risk stratification and early detection of HCC are critical unmet needs for improving outcomes. Several blood-based biomarkers and imaging tests are available for early detection, prediction, and monitoring of HCC. However, serum protein biomarkers such as alpha-fetoprotein have shown relatively low sensitivity, leading to inaccurate performance. Imaging studies also face limitations related to suboptimal accuracy, high cost, and limited implementation. Recently, liquid biopsy techniques have gained attention for addressing these unmet needs. Liquid biopsy is non-invasive and provides more objective readouts, requiring less reliance on healthcare professional’s skills compared to imaging. Circulating tumor cells, cell-free DNA, and extracellular vesicles are targeted in liquid biopsies as novel biomarkers for HCC. Despite their potential, there are debates regarding the role of these novel biomarkers in the HCC care continuum. This review article aims to discuss the technical challenges, recent technical advancements, advantages and disadvantages of these liquid biopsies, as well as their current clinical application and future directions of liquid biopsy in HCC.
7.Research progress in online monitoring technologies for workplace dust concentration
Qiangzhi GUO ; Yuntao MU ; Jinning YU ; Chuntao GE ; Chen WANG ; Zhiguo ZHOU ; Xue JIANG ; Yazhen WANG ; Jinling LIU ; Di LIU ; Shibiao SU
China Occupational Medicine 2025;52(4):472-476
Occupational pneumoconiosis remains the most common occupational disease in China, with occupational mineral dust exposure being its primary causative factor. Although national standards for online monitoring and early warning systems of coal mine dust concentrations have been established, national occupational health standards for rapid and online monitoring of dust concentration and particle size distribution in other industries are still limited. Among dust concentration sensor technologies, the light scattering method is the preferred choice for online dust monitoring owing to its wide measurement range and low cost. The beta-ray absorption method is mature but highly sensitive to humidity. The electrostatic induction method offers high sensitivity, simple structure, and low maintenance costs but exhibits high errors in low-concentration dust monitoring. The tapered element oscillating microbalance method is highly sensitive but costly. Multi-sensor data fusion technology can improve monitoring reliability, however, mature domestic products are not yet available. For monitoring dust particle size distribution, sieving and sedimentation methods are cumbersome. The aerodynamic method shows broad prospects in the online monitoring of respirable dust but has obvious measurement errors for larger dust particles. The use of optical measurement method is limited by dust morphology and is not suitable for monitoring coal dust particle size distribution. The electrical mobility method is primarily applicable to submicron dust. Future research should focus on promoting the application of monitoring technology for respirable dust particle size distribution in online monitoring of industrial dust. By integrating Internet of Things, data mining, and artificial intelligence technologies, along with multi-sensor data fusion and numerical simulation, dust concentration prediction models can be established to achieve accurate dust concentration monitoring and early warning of exceedances. The advancements of technologies will provide scientific support for the assessment of industrial dust hazards and the prevention and control of occupational pneumoconiosis.
8.Preemptive immunotherapy for KMT2A rearranged acute leukemias post-allogeneic stem cell transplantation.
Jing LIU ; Shuang FAN ; Xiaohui ZHANG ; Lanping XU ; Yu WANG ; Yifei CHENG ; Chenhua YAN ; Yuhong CHEN ; Yuanyuan ZHANG ; Meng LV ; Yazhen QIN ; Xiaosu ZHAO ; Xiaojun HUANG ; Xiaodong MO
Chinese Medical Journal 2025;138(22):3034-3036
9.Determination of 27 volatile organic compounds in exhaled breath by thermal desorption-gas chromatography-mass spectrometry
Rui GAO ; Fangda PENG ; Yazhen HE ; Jie FENG ; Wubin LIU ; Lijia YU ; Qingsong CHEN ; Chunguang DING
Journal of Environmental and Occupational Medicine 2024;41(1):96-102
Background Volatile organic compounds (VOCs) in exhaled breath are closely associated with respiratory diseases and are linked to various metabolic reactions in the human body. A quantitative analytical method can provide technical support for studying VOCs related to various diseases. Objective To establish a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method for the determination of 27 VOCs in exhaled breath. Methods VOCs in exhaled breath were collected using a Bio-VOC sampler and enriched with Tenax TA thermal desorption tubes before TD-GC-MS analysis. Standards were collected using thermal desorption tubes and optimized for thermal desorption conditions as well as chromatographic and mass spectrometric conditions: The separation of the 27 VOCs was achieved by an optimized temperature program, the improvement of sensitivity by optimizing quantitative ions, and the increase of VOCs desorption efficiency by optimizing thermal desorption time and temperature. Limit of detection, limit of quantification, accuracy, precision, and stability of the proposed method were investigated by spiking with a blank gas bag, and exhaled breath samples from 20 healthy individuals were collected for an application study of the proposed method. Results The thermal desorption temperature was 280 ℃, and desorption time was 6 min. A VF-624ms chromatographic column was selected for the separation of target substances. The initial temperature of heating program was 35 ℃, maintained for 1 min, and then increased to 100 ℃ at a heating rate of 3 ℃·min−1 for 1 min, followed by increasing to 210 ℃ at a heating rate of 28 ℃·min−1 for 5 min. A quantitative analysis was conducted with a single ion monitoring (SIM) mode. Under these conditions, the 27 VOCs showed good linear relationships in their respective concentration ranges and the correlation coefficients were higher than 0.9990. The limits of detection of the method were in the range of 0.01-0.13 nmol·mol−1, the limits of quantification were in the range of 0.02-0.44 nmol·mol−1, and the spiked recoveries were in the range of 80.1%-120.5%, with intra-batch and inter-batch precision ≤ 18.8% and 17.9% respectively. All substances can be stored at room temperature (23-28 °C) for 7 d and at 4 °C for 14 d. The proposed method was applied to exhaled breath samples from 20 subjects with detection rates≥ 80% (except for trans-2-pentene and decane) and a concentration range of 0.00-465.50 nmol·mol−1. Conclusion The established TD-GC-MS method for quantification of VOCs in exhaled breath is characterized by high sensitivity and good accuracy, and is suitable for quantitative determination of VOCs in exhaled breath, which can provide technical support for the study of exhaled breath VOCs.
10.Comparison of occupational exposure limits in China with threshold limit values announced by American Conference of Governmental Industrial Hygienists
Qiangzhi GUO ; Yazhen WANG ; Yuntao MU ; Jinling LIU ; Xue JIANG ; Di LIU ; Chen SHEN ; Lingling LI ; Yi LIU
Journal of Environmental and Occupational Medicine 2024;41(11):1290-1296
Background The threshold limit values (TLVs) established and regularly updated by the American Conference of Governmental Industrial Hygienists (ACGIH) are widely adopted and referenced globally, serving as a crucial reference for China's occupational exposure limits (OELs). It is necessary to track it regularly and compare it with China's OELs. Objective To compare the OELs stipulated in Occupational exposure limits for hazardous agents in the workplace—Part 1: Chemical hazardous agents (GBZ 2.1—2019) and the ACGIH TLVs (2024) and to provide references for subsequent formulation and revision of OELs in China. Methods The OELs specified in GBZ 2.1—2019 and the TLVs issued by ACGIH were used to establish a database using Microsoft Excel 2019 software. Cross verification was conducted through matching Chemical Abstracts Service Registry Numbers (CAS Rn) and both Chinese and English names to ensure accuracy. Then, comparisons and analyses were carried out based on the type of limit values, which were matched as follows: permissible concentration-time weighted average (PC-TWA) with threshold limit value-time weighted average (TLV-TWA), permissible concentration-short term exposure limit (PC-STEL) with threshold limit value-short term exposure limit (TLV-STEL), and maximum allowable concentration (MAC) with threshold limit value-ceiling (TLV-C). Comparisons included types, quantities, and sizes of limits. Results The GBZ 2.1—2019 OELs and the ACGIH TLVs (2024) were generally consistent in terms of types and definitions, but there were differences in the number and size of the limits. In terms of the number of limits, GBZ 2.1—2019 specified 365 OELs for 358 chemical hazardous agents, while ACGIH TLVs (2024) included 316 corresponding limits. Among these, 148 (46.9%) limits were consistent, 38 (12.0%) were basically consistent, and 130 (41.1%) were inconsistent. In terms of the size of the limits, out of the 130 inconsistent limits, 51 OELs were lower than the corresponding TLVs, 67 OELs were higher than the corresponding TLVs, and 12 were under different limit types. For some chemical hazardous agents, their OELs were significantly lower or higher than their TLVs. Conclusion Some of the OELs for chemical hazardous agents specified in GBZ 2.1—2019 are significantly lower or higher than the TLVs. For these chemical hazardous factors, it is recommended to prioritize their inclusion in research projects and to complete the revisions as soon as possible based on the latest scientific evidence.

Result Analysis
Print
Save
E-mail