1.Pharmacokinetic study of the antidepressant active components from Jiaotai pills in healthy subjects
Yujie CHEN ; Yiran WANG ; Zhipeng LIAO ; Xinfang BIAN ; Yanjun WANG ; Wenzheng JU
China Pharmacy 2026;37(3):366-370
OBJECTIVE To study the pharmacokinetic characteristics of antidepressant active components from Jiaotai pills in healthy subjects. METHODS Eight healthy subjects (3 males and 5 females) were recruited and given a single oral dose of 8.55 g of Jiaotai pills. Venous blood samples were collected before administration (0 h) and at intervals from 0.25 to 36.0 hours post- administration. After treating the plasma samples with protein precipitation, the blood concentrations of the antidepressant active ingredients (coptisine, berberine, magnoflorine, and palmatine) in Jiaotai pills were determined using liquid chromatography- tandem mass spectrometry (LC-MS/MS) method. DAS 2.0 software was employed to calculate the pharmacokinetic parameters of healthy subjects [half-life (t1/2), peak concentration (cmax), time to peak concentration (tmax), area under the concentration-time curve (AUC), and mean residence time (MRT)] using a non-compartmental model. RESULTS After healthy subjects took Jiaotai pills, the drug-time curve of the four antidepressant active ingredients conforms to a two-compartment model and tmax values were similar, with all reaching peak blood concentrations within 2.00 to 4.00 hours post-administration. However, the t1/2 and MRT of coptisine and berberine were significantly longer than that of magnoflorine and palmatine. There were also significant differences in the AUC and cmax among the four antidepressant active ingredients, with magnoflorine exhibiting markedly higher AUC0-t and cmax compared to the other three components. CONCLUSIONS In this study,LC-MS/MS is used to analyze the pharmacokinetic characteristics of the antidepressant active ingredients from Jiaotai pills in healthy subjects, can provide valuable references for the clinical application of Jiaotai pills.
2.Analysis of data from the survey of radiotherapy resources in Gansu Province, China, 2024
Jialong WU ; Yun WANG ; Hanyu ZHANG ; Jie WANG ; Yanjun WANG ; Fang WANG ; Qian WANG ; Ruiying WANG ; Xiangru QU ; Limei NIU ; Qin CHEN
Chinese Journal of Radiological Health 2026;35(1):1-5
Objective To investigate the current distribution of radiotherapy resources in Gansu Province, evaluate the equity of resource allocation, and provide a scientific basis for optimizing regional resource allocation. Methods A questionnaire survey was carried out to assess radiotherapy resources in medical institutions across Gansu Province, China. The equity of radiotherapy resource distribution and associated disparities were assessed using the Gini coefficient, Lorenz curve, and Theil index. Results A total of 23 medical institutions in Gansu Province provided radiotherapy services, comprising 39 radiotherapy devices and 438 professionals, of whom medical physicists accounted for 16.9%. The radiotherapy frequency was 0.47 cases per thousand population. The Gini coefficients for radiotherapy resource distribution ranged from 0.38 to 0.56 by population and from 0.52 to 0.70 by geography. The Theil index for radiotherapy resources ranged from 1.36 to 3.67. Conclusion Radiotherapy resources in Gansu Province were insufficient, and the capacity of radiotherapy service was suboptimal. The equity of radiotherapy resource allocation by geography was worse than that by population. Therefore, it is imperative to address the shortage of radiotherapy resources, strengthen the professional workforce, enhance the capacity radiotherapy service and resource utilization, optimize resource allocation, and promote regional equity in radiotherapy provision in Gansu Province.
3.A Case of Autologous Reconstruction with TRAM Flap Combined with Contralateral Reduction in Lactational Patient with Breast Cancer and Macromastia
Weifang ZHANG ; Yueyao SUN ; Yanjun LIU ; Yifang WANG ; Xin CHEN ; Jie ZHANG ; Mengyang AN ; Bo LIU ; Fangjian SHANG
Cancer Research on Prevention and Treatment 2026;53(3):233-236
4.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.
5.Automatic Detection of Quality Control Performance of Radio Frequency Coils Based on ACR Phantom
Yawen LIU ; Hongxia YIN ; Yu ZHANG ; Pengling REN ; Yanjun HU ; Hui XU ; Zhenghan YANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):601-606
Purpose To explore an automatic detection method for quality control performance indicators of radio frequency coils based on American College of Radiology(ACR)phantom,and verify its accuracy stability and computational efficiency.Materials and Methods A retrospective study was conducted on 50 quality control images collected based on ACR phantom in Beijing Friendship Hospital,Capital Medical University from May 2017 to July 2019.The measurement and calculation methods of signal noise ratio(SNR),percent image uniformity(PIU)and percent signal ghosting(PSG)were used to automatically calculate the above indicators using a self-designed program in Python.A simple linear regression analysis on the automatically calculated SNR,PSG and PIU values compared to the manually measured results was performed,and Bland-Altman analysis was used to calculate the percentage difference to evaluate the consistency and bias between the performance indicators calculated by the two methods.The time consumption of two detection methods was compared to verify their computational complexity and efficiency.Results There was a strong correlation between the performance indicators SNR,PSG and PIU of radio frequency coils measured and calculated automatically and manually(r=0.991 4,0.992 8 and 0.909 8,all P<0.0001).The Bland-Altman results showed that most of the data fall within the 95%confidence interval and were evenly distributed.In terms of computational complexity and efficiency,compared to the complex manual delineation and calculation of 2-3 minutes per case,automatic detection could simultaneously obtain SNR,PSG and PIU values in less than 1 second.Conclusion The automatic and manual measurement methods have good consistency,and the automatic detection method is easy to operate,which is helpful for the daily quality control work and performance monitoring of radio frequency coils.
6.Combining radiomics and deep learning to predict overall survival in non-small cell lung cancer patients
Yongxin LIU ; Qiusheng WANG ; Huayong JIANG ; Na LU ; Diandian CHEN ; Yanjun YU ; Yanxiang GAO ; Huijuan ZHANG ; Minmin DENG ; Yinglun SUN ; Fuli ZHANG
Chinese Journal of Medical Physics 2025;42(11):1462-1468
Objective To develop a combined model integrating radiomics and 3D deep learning features for improving the predictive efficacy of overall survival in non-small cell lung cancer(NSCLC)patients undergoing radiotherapy,thereby providing a foundation for optimizing individualized radiotherapy strategies.Methods A retrospective analysis was conducted on 522 NSCLC patients from 3 centers.Radiomics features were extracted from the tumor region of interest on radiotherapy planning CT scans,and a 3D-SE-ResNet was constructed to extract deep learning features.Following feature extraction,features were selected via univariate Cox analysis and Lasso-Cox regression,and a combined model was established by fusing the two feature types through principal component analysis.The discriminative ability of the model was evaluated using the concordance index(C-index)and the area under the receiver operating characteristic curve(AUC),while the risk stratification efficacy was verified by Kaplan-Meier survival analysis.Results The predictive performance of deep learning features was significantly superior to that of radiomics features(C-index:0.73 vs 0.65).The combined model achieved the highest predictive performance in the training set,internal test set,and external test set(C-index:0.74,0.69,0.72 respectively),with higher AUC values for predicting 1-year,2-year,and 3-year OS than either single model.Kaplan-Meier analysis showed significant differences in survival between the high-and low-risk groups(Log-rank test,P<0.001),and calibration curves indicated good consistency between predicted and actual survival outcomes.Conclusion The combined model integrating radiomics and 3D deep learning features can accurately predict survival outcomes in NSCLC patients undergoing radiotherapy.The multi-center validation results support its potential application in prognosis stratification for individualized radiotherapy.
7.Iodine nutrition status of pregnant women in Weihai City before and after iodine deficiency disorders intervention
Shuliang LIU ; Huaqiang SUN ; Guoying ZHANG ; Zhifang WANG ; Linqing XIU ; Lingfei ZHANG ; Yanjun WU ; Min YIN ; Lei LIN ; Shuai ZHAO
Chinese Journal of Endemiology 2025;44(4):313-317
Objective:To analyze the iodine nutrition status of pregnant women in Weihai City before and after (2022, 2023) the iodine deficiency disorders (IDD) intervention, evaluate the effectiveness of intervention measures, and provide a scientific basis for adjusting IDD prevention strategies in the city.Methods:In May 2023, the intervention action of IDD was carried out for pregnent women in Weihai City. In April 2022 and December 2023, respectively, a cross-sectional survey method was conducted in four districts (cities) of Weihai City. Each district (city) was divided into five areas (east, west, south, north, and central) each year, and one township (street) was selected from each areas. At least 20 pregnant women were selected from each township (street) as survey subjects, and their household salt samples and random urine samples were collected to measure salt iodine and urinary iodine concentrations, and to compare the test results.Results:A total of 922 household salt samples were tested, including 530 iodized salt samples and 469 qualified iodized salt samples. The median salt iodine was 24.00 mg/kg. The coverage rate of iodized salt, the qualified rate of iodized salt, and the consumption rate of qualified iodized salt were 57.48%, 88.49%, and 50.87%, respectively. No significant difference was observed in medians salt iodine between 2022 (24.26 mg/kg) and 2023 (24.00 mg/kg, Z = - 1.58, P = 0.113). However, the coverage rate of iodized salt and the consumption rate of qualified iodized salt in 2023 werehigher than those in 2022 [73.72% (373/506) vs 37.74% (157/416), 65.22% (330/506) vs 33.41% (139/416), χ 2 = 120.90, 92.40, P < 0.001]. A total of 922 urine samples were collected from pregnant women, with a median urinary iodine of 135.90 μg/L. The median urinary iodine of pregnant women in 2022 was 113.55 μg/L. There was a statistically significant difference in medians urinary iodine among different regions ( H = 27.91, P < 0.001). The median urinary iodine of pregnant women in 2023 was 153.00 μg/L. There was no statistically significant difference in medians urinary iodine among different regions ( H = 3.33, P = 0.343). The medians urinary iodine of pregnant women in Huancui District, Wendeng District, and Rushan City in 2023 (156.60, 155.00, 140.85 μg/L) were higher than those in 2022 (93.60, 110.00, 110.70 μg/L), and the differences were statistically significant ( Z = - 5.44, - 4.92, - 5.99, P < 0.001). The median urinary iodine of pregnant women in Weihai City in 2023 showed a statistically significant difference compared to 2022 ( Z = - 7.62, P < 0.001). Conclusions:The IDD intervention measures in Weihai City have achieved good results, and the coverage of iodized salt, the consumption rate of qualified iodized salt, and the iodine nutrition level of pregnant women have improved. We should continue to implement intervention measures, improve the iodine nutrition level of key populations, and maintain a sustained elimination of IDD.
8.Efficacy and Safety of Qixian Tongluo Formula in the Treatment of Post-Cerebral Infarction Paralysis with Kidney Deficiency and Blood Stasis Syndrome:A Pragmatic Randomized Controlled Trial and Preliminary Exploration of miRNA Cross-Kingdom Regulation Mechanism
Shengqiang ZHOU ; Yanjun CHEN ; Guo MAO ; Wen ZENG ; Jia HUANG ; Zhixin LI ; Jintao XIAO ; Ruizhen WANG ; Lingjuan TAN ; Fang LIU
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(4):1120-1130
Objective To evaluate the efficacy and safety of Qixian Tongluo Formula in the treatment of post-cerebral infarction paralysis with kidney deficiency and blood stasis syndrome,and to preliminarily explore the molecular mechanism of Qixian Tongluo Formula in improving impaired motor function from the perspective of cross-kingdom regulation of Chinese medicine microRNA(miRNA).Methods A pragmatic randomized controlled trial was conducted with 102 patients in the recovery period of post-cerebral infarction paralysis with kidney deficiency and blood stasis syndrome in our hospital.Patients were randomly divided into trial group and control group,with 51 cases in each group.The control group received standard Western medicine standard treatment,while the trial group received Qixian Tongluo Formula in addition to the standard treatment,with one dose per day,boiled in water,and taken warm after breakfast and dinner for a course of 2 months.The disability rate was used as the main efficacy indicator,and the incidence of adverse reactions was used as a safety indicator.miRNA from patient serum and Qixian Tongluo decoction were extracted respectively,and high-throughput sequencing was performed.The two sequences were compared to screen out the cross-kingdom gene transfer of Chinese medicine miRNA.Finally,its target genes of miRNA were predicted,and GO function and KEGG pathway enrichment analysis were carried out.Results A total of 67 patients completed the clinical trial,including 36 cases in the trial group and 31 cases in the control group;The disability rate in the trial group(13.9%)was lower than that in the control group(35.5%)(P<0.05);The incidence of adverse reactions was similar between the trial group(7.69%)and the control group(6.06%)(P>0.05);A total of 9530 Qixian Tongluo decoction miRNA sequences were screened,with 150 potentially involved in cross-kingdom gene transfer,including families such as miR-15 and miR-17;According to the target gene prediction of the top 10 miRNAs in cross-kingdom gene transfer of Chinese medicine,345 overlapping target genes were obtained;GO functional enrichment analysis revealed 16 biological processes,7 cellular components,and 2 molecular functions among the top 25 enriched functions,while KEGG pathway analysis mainly focused on the transforming growth factor-βsignaling pathway,neurotrophin signaling pathway,which are closely related to neural repair and functional recovery processes such as glial scar formation and synaptic plasticity after cerebral ischemia.Conclusion Qixian Tongluo Formula can significantly improve the functional independence level of patients with kidney deficiency and blood stasis syndrome in the recovery period of paralysis after cerebral infarction,offering a safe and effective treatment option for these patients;There were a large number of miRNAs in Qixian Tongluo decoction,some of which could cross-kingdom transferred into the human blood circulation,and promote the recovery of motor function in patients with cerebral infarction through multi-target,multi link and multi pathway gene network regulation.This study provides a new idea for subsequent clinical and basic research.
9.Study on the diagnostic efficacy and influencing factors of quantitative infrapatellar fat pad fat fraction and T2* values using mDixon-Quant technique for knee osteoarthritis
Xinru ZHANG ; Yanjun CHEN ; Xintao ZHANG ; Yiou WANG ; Xiaodong ZHANG
Journal of Practical Radiology 2025;41(5):819-823
Objective To investigate the diagnostic efficacy of fat fraction(FF)and T2* values of infrapatellar fat pad(IPFP)based on MR mDixon-Quant technique for knee osteoarthritis(KOA),and to analyze their related influencing factors.Methods A total of 178 knee joints from 114 volunteers were included and underwent knee joints X-ray examination and MR mDixon-Quant sequence scanning.The correlation between FF and T2* values of IPFP with gender,age,body mass index(BMI),and K-L grade was analyzed by Spearman's test and multiple linear regression.Receiver operating characteristic(ROC)curves were plotted to assess the diag-nostic efficacy of FF and T2* values for KOA.Results FF value of IPFP was negatively correlated with age,BMI,and K-L grade(r=-0.470,-0.276,-0.679,P<0.001),and T2* value was also negatively correlated with age,BMI,and K-L grade(r=-0.291,-0.173,-0.505,P<0.001).Multiple linear regression analysis results showed that only K-L grade had a statistically significant correlation with FF and T2* values(P<0.001).ROC curve analysis indicated that the area under the curve(AUC)for diagnosing KOA using the FF and T2* values of IPFP were 0.859 and 0.767,respectively,with sensitivity of 0.878 and 0.841,and specificity of 0.719 and 0.573,respectively.The combined diagnosis had an AUC of 0.855,a sensitivity of 0.625,and a specificity of 0.963,improving the diagnostic specificity for KOA.Conclusion FF and T2* values of IPFP can serve as objective imaging indicators for KOA assessment,and their reduction is correlated with the progress of age,BMI,and K-L grade,of which the K-L grade is an independent influencing factor.The combination of FF and T2 can improve the diagnostic specificity of KOA,and provide a quantitative basis for early KOA detection and severity stratification.
10.Ultrasonic morphological characteristics of superficial and deep thoracolumbar paraspinal muscles in patients with moderate adolescent idiopathic scoliosis
Shanshan ZHANG ; Yanjun WANG ; Zhiwei LIAN ; Yi XU ; Binbin YANG ; Qiuli LIANG ; Chuhuai WANG
Chinese Journal of Spine and Spinal Cord 2025;35(4):366-375
Objectives:To explore the morphological changes of the superficial and deep thoraolumbar paraspinal muscles on both convex and concave sides during rest and contraction states in patients with mod-erate adolescent idiopathic scoliosis(AIS),and their effects on scoliosis angle,to analyze the relations between scoliosis angle and the morphological changes of paraspinal muscles.Methods:21 AIS patients(thoracic Cobb angle 20°-45°,S-shaped with the main curve in thoracic segment,4 males and 17 females,aged 13.9±1.6 years old)treated in our hospital from July 2020 to December 2023 and 21 healthy subjects(7 males and 14 females,aged 14.6±1.4 years old)were prospectively enrolled.The morphological data of thoracolumbar paraspinal muscles were collected with musculoskeletal ultrasound,including the resting thickness and thick-ness during maximum voluntary isometric contraction(MVIC)of superficial erector spinae(ES)and multifidus(MF)muscles of AIS patients on both convex and concave sides(left and right sides of healthy controls).The differences in resting thickness,contraction thickness,change rate of contraction thickness,and total resting thickness and total contraction thickness(ES+MF)of superficial and deep thoracolumbar paravertebral muscles between the two groups were analyzed,and the structural characteristics of the thoracolumbar paravertebral muscles on the convex and concave sides of AIS were analyzed.The correlation between Cobb angle in tho-racolumbar segment and morphological indexes(resting thickness,contraction thickness change rates)of ES and MF muscles was analyzed,and the influence of scoliosis severity on the morphology of superficial and deep paravertebral muscle was further analyzed.Results:In AIS patients,the mean thoracic Cobb angle were 31.62°±7.68°,and mean lumbar Cobb angle were 19.52°±6.48°.Comparing with healthy controls,patients with AIS were significantly different in resting thickness,contraction thickness and thickness change rates of tho-racic paraspinal muscles on both convex and concave sides,and the resting thickness of ES in thoracic seg-ment on concave side was less than that on the convex side,which of MF was less on the convex side than on the concave side(P<0.01).The contraction thickness of thoracic MF muscles on the convex and concave sides in S-type AIS patients was smaller than that in healthy controls(P<0.05),while the contraction thickness of thoracic ES muscles on the convex and concave side wasn't statistically different from that of healthy con-trols,and the contraction thickness change rate of ES muscles on the convex and MF on the concave side of thoracic segment in AIS patients was significantly decreased(P<0.05).There was no significant difference in the total resting thickness of thoracic(convex and concave)paravertebral muscles(ES+MF)between AIS patients and the corresponding segments(left and right)of control group(P>0.05),and there was no statistically signifi-cant difference in the total resting thickness of thoracic paravertebral muscle between the convex and concave sides of AIS patients(P>0.05).The total contraction thickness of thoracic paravertebral muscle(ES+MF)in AIS patients was lower than that in control group(P<0.05).Compared with the control group,the resting thickness,contraction thickness and thickness change rate of lumbar MF muscle on the convex and concave sides in AIS patients were significantly reduced(P<0.05),and the contraction thickness change rate of the lumbar ES muscle on the concave side was less than that of the control group(P<0.05).There were no significant differ-ences in resting thickness and contraction thickness between the convex and concave paravertebral muscles in AIS patients(P>0.05).The total resting thickness(ES+MF)and total contraction thickness(ES+MF)of lumbar(convex and concave)paraspinal muscles in AIS patients were lower than those in control group(P<0.05).There was a significant negative correlation between the Cobb angle of the main thoracic curve and the rest-ing thickness of the thoracic MF muscle on the concave and the change rate of the contraction thickness of the thoracic ES muscle on the convex in S-type AIS patients(r=-0.53/-0.45,P<0.05).There was no signifi-cant correlation between the Cobb angle of lumbar segment and the change rates of the resting thickness and contraction thickness of ES and MF muscles on both convex and concave sides(P>0.05).Conclusions:In pa-tients with moderate S-type AIS,there are different muscle morphological changes in the paraspinal muscles on both convex and concave sides of the main thoracic curve,and the concave paravertebral muscle is more affected by scoliosis;The contraction function of the bilateral deep core stabilizing muscles in the lumbar re-gion is markedly decreased.Different patterns of superficial and deep muscle atrophy and contractility decline may be a key cause of spinal movement disorder and scoliosis progression in AIS patients.

Result Analysis
Print
Save
E-mail