1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Disease burden and changing trend in tracheal, bronchus, and lung cancer attributable to air pollution globally and in China and the United States from 1990 to 2021
Shoucai HU ; Chenglong YANG ; Lingling ZHANG ; Fu LI ; Yanan ZHANG ; Bin LIU ; Qingxin LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):97-104
Objective To systematically analyze the spatiotemporal distribution characteristics and epidemiological trends of tracheal, bronchus, and lung cancer (TBL) disease burden attributed to air pollution globally and in China and the United States from 1990 to 2021, and to assess the patterns of disease burden changes from 2022 to 2031 based on predictive models, providing a scientific basis for formulating targeted TBL prevention and control strategies. Methods Based on the Global Burden of Disease (GBD) 2021 database, we analyzed the disease burden data of TBL attributed to air pollution globally and in China and the United States from 1990 to 2021. R Studio 4.3.2 software was used to analyze the corresponding trends and the Bayesian age-period-cohort (BAPC) prediction model was used to predict the status of the disease burden of TBL attributed to air pollution in the world and in China and the United States from 2022 to 2031. Results In 2021, China had the highest number of deaths and disability-adjusted life years attributed to air pollution (211 400 patients and 4.8947 million person-years), followed by the United States (6 000 patients and 124 300 person-years). The age-standardized mortality rate (ASMR) and age-standardized disability-adjusted life years rate (ASDR) of TBL due to air pollution in the world and in China and the United States showed a decreasing trend. From 1990 to 2021, the ASMR and ASDR of TBL in China due to air pollution were much higher than those in the United States and the global average. In terms of gender, from 1990 to 2021, the disease burden of male patients with TBL attributed to air pollution was much higher than that of female patients. The BAPC prediction model showed that from 2022 to 2031, the ASMR and ASDR of TBL attributed to air pollution showed an upward trend globally, while they showed a downward trend in China and the United States. Conclusion Over the past 30 years, the air pollution-related TBL disease burden in the world and in China and the United States has continued to decline, but China's disease burden is still significantly higher than the global average. The disease burden in men far exceeds that in women, with men and the population aged ≥50 years being high-risk groups. In the future, the global disease trend may reverse and rise, while China and the United States are expected to continuously decline. However, precise prevention and control for high-risk groups remains a key challenge.
3.Staged Efficacy of Qijia Rougan Prescription Combined with Entecavir for Chronic Hepatitis B-related Hepatic Fibrosis with Qi Deficiency and Collateral Stasis Syndrome Based on "Zhu Ke Jiao" Theory
Baixue LI ; Xin WANG ; Jibin LIU ; Li WEN ; Cen JIANG ; Wenjun WU ; Dong WANG ; Shuwan LIU ; Huabao LIU ; Yongli ZHENG ; Liang HUANG ; Yue SU ; Song ZHANG ; Yanan SHANG ; Hang ZHOU ; Quansheng FENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):180-188
ObjectiveThis paper aims to investigate and evaluate the staged efficacy and safety of the representative empirical prescription of the “Zhu Ke Jiao” theory, Qijia Rougan prescription, combined with entecavir in the treatment of hepatic fibrosis in chronic hepatitis B. MethodsA multicenter randomized controlled clinical study was conducted, and 101 patients diagnosed with chronic hepatitis B-related hepatic fibrosis (CHB-HF) who met the diagnosis and inclusion criteria were randomly assigned to an observation group (Qijia Rougan prescription + entecavir) and a control group (entecavir). The treatment duration was 24 weeks. Liver stiffness measurement (LSM), fibrosis-4 index (FIB-4), portal vein diameter, hepatitis B serology, biochemical indicators, hepatic fibrosis markers in serum [hyaluronic acid (HA), laminin (LN), procollagen Ⅲ peptide (PⅢP), and type Ⅳ collagen (Ⅳ-C)], and traditional Chinese medicine syndrome scores were used as efficacy evaluation indicators. Efficacy assessments and explorations of different staged subgroups of Qijia Rougan prescription were conducted according to LSM values based on the Metavir pathological staging standard. ResultsA total of 98 cases were included for statistical analysis, with 49 cases in the observation group and 49 in the control group. The general data of the patients in both groups were comparable. Compared with the same group before treatment, the observation group showed a significant reduction in LSM and FIB-4 (P<0.01), as well as notable improvements in LN, Ⅳ-C, and various TCM syndrome scores (P<0.05, P<0.01). When compared to the control group after treatment, the observation group demonstrated significant improvements in LSM, FIB-4, and various TCM syndrome score indicators (P<0.05, P<0.01), indicating that the observation group performed better than the control group. Subgroup analysis of the regression of hepatic fibrosis stages showed that compared to the same group before treatment, the observation group had better improvement in regression of stages F2 and F3 (P<0.05). When compared to the control group after treatment, the observation group exhibited superior improvement in regression of stage F3 (P<0.05). No adverse events occurred in either group during the treatment period. ConclusionCompared with entecavir alone, the combination of Qijia Rougan prescription and entecavir significantly improves the degree of hepatic fibrosis and clinical TCM symptoms in patients. The optimal intervention period is primarily during stage F3, which is a potential “interception” point of the “Zhu Ke Jiao” theory.
4.Serum vitamin D and vitamin K 1 levels in children with physical examination at the child health care outpatient clinics of a hospital in Qingdao
LIU Qing, L Yanan, ZHANG Tingting, LI Yufen
Chinese Journal of School Health 2026;47(2):173-177
Objective:
To understand the serum vitamin D and vitamin K 1 levels of children in the Qingdao area, so as to provide scientific grounds for appropriate vitamin supplementation.
Methods:
A total of 4 469 children aged 0-14 years old, who attended the children s healthcare outpatient clinics of a tertiary hospital in Qingdao, were enrolled in the current study between January 2023 and July 2024. The levels of vitamin D and vitamin K 1 were measured by liquid chromatography tandem mass spectrometry. The inter group differences were analyzed using Chi square test, Wilcoxon rank sum test, and Kruskal-Wallis H test. The correlation analysis of vitamin D and vitamin K 1 levels with age was performed using the Spearman correlation.
Results:
The serum vitamin D level among children was 28.72(22.67, 36.26)ng/mL. The vitamin D deficiency and insufficiency rates were 2.10% and 14.59 %, respectively. The serum 25-(OH)D 2 level was 0.29(0.14, 0.53)ng/mL, the serum 25-(OH)D 3 level was 27.99( 21.78 , 35.57)ng/mL and the serum vitamin K 1 level was 0.54(0.29, 1.04)ng/mL. The vitamin K 1 deficiency rate was 13.76%. Among different age stages, the serum vitamin D level was highest in infancy [37.45(30.39, 43.87)ng/mL] and lowest in school age children [22.39(18.00, 26.97)ng/mL]; the level of vitamin K 1 was highest in preschool children [0.79(0.41, 1.51) ng/mL] and lowest in school age children[0.45 (0.26, 0.76) ng/mL]; the serum vitamin D deficiency and insufficiency rates were highest in school age children (5.03% and 30.81%); the vitamin K 1 deficiency rate was highest in infancy (21.53%) ( H/χ 2=1 698.31, 253.70 , 137.85 , 583.79, 89.30, all P <0.05). Among different seasons, the serum vitamin D and vitamin K 1 levels were lowest in the winter [26.74(18.37, 35.86) and 0.50 (0.27, 0.94)ng/mL; H =50.71, 7.86]; the vitamin D deficiency and insufficiency rates were highest in the winter (5.41% and 24.80%; χ 2=59.93, 83.35) (all P <0.05). The serum vitamin D level had a moderate negative correlation with age ( r =-0.62), and there was a low positive correlation between the serum vitamin D and vitamin K 1 levels in infancy and early childhood ( r =0.21, 0.26) (all P <0.05).
Conclusions
The serum vitamin D and vitamin K 1 levels are lowest in school age children and in the winter, and the serum vitamin K 1 deficiency rate is highest in infancy. There is a need to focus on critical periods of infancy and school age, and strengthen interventions during the high risk winter season. The nutritional status of vitamin D and vitamin K 1 in children should be enhanced.
5.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
6.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
7.Kappa angle on visual quality after regional refractive MIOL implantation in high myopic patients complicated with cataract
Hongdan ZHAO ; Yanan LIU ; Yanfang LI ; Yue DONG
International Eye Science 2026;26(8):1348-1353
AIM: To explore the effect of Kappa angle on changes in visual quality and stereoscopic acuity after regional refractive multifocal intraocular lens(MIOL)implantation in patients with high myopia complicated by cataract.METHODS:A retrospective analysis was conducted on data from patients with normal Kappa angle and high myopia complicated by cataract treated at the hospital from January 2024 to January 2025. Patients were divided into two groups based on the median preoperative Kappa angle(0.182 mm): Group A(0
8.Investigation on status quo and influencing factors of limited social participation in young patients with ankylosing spondylitis
Yanan LIU ; Qian CHEN ; Jie GAO
Journal of Public Health and Preventive Medicine 2026;37(4):177-180
Objective To investigate the status quo of limited social participation in young patients with ankylosing spondylitis (AS), and analyze its influencing factors. Methods Using the random number table method, a simple random sampling method was employed to select 320 young patients with ankylosing spondylitis who were admitted to the First Affiliated Hospital of Naval Medical University from June 2023 to June 2025. Chinese version of social participation scale was applied to evaluate the level of social participation of patients. The above patients were classified into unlimited group (n=148) and limited group (n=172). Logistic regression analysis was performed to analyze the independent influencing factors for limited social participation. Results Compared with the unlimited group, the limited group exhibited longer course of AS, higher BASDAI score, BASFI score, HAMA score, HAMD score and ASQoL score as well as lower PSSS score (P<0.05). Logistic regression analysis suggested that course of disease, high disease activity score, high anxiety score, high depression scores and low social support scores are the relevant factors for the restricted social participation of young patients with ankylosing spondylitis. Conclusion The phenomenon of limited social participation is common in young patients with AS, and its occurrence is the result of a combination of factors such as disease course, disease activity, anxiety, depression and social support level.
9.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
10.Development of a Microstream End-Tidal Carbon Dioxide Monitoring System with Integrated Gas Circuit.
Yanan LIU ; Xuedong SONG ; Qi YIN ; Fuhao KANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(2):204-211
End-tidal carbon dioxide monitoring is an important means of evaluating human lung function and is widely used in fields such as clinical emergency treatment and cardiopulmonary resuscitation. This paper develops a microstream end-tidal carbon dioxide monitoring system. It adopts an integrated gas circuit design to further reduce the size of the equipment. The system uses the method of calculating the root mean square (RMS) of differential pressure signals to regulate the gas circuit flow, enabling the system to stably operate at a flow state of 30 mL/min. In addition, by simultaneously detecting multiple environmental parameters such as temperature and pressure, the system realizes system state monitoring and gas parameter compensation. The test results show that various indicators of the system meet the requirements of relevant standards, laying a good foundation for subsequent engineering applications.
Carbon Dioxide/analysis*
;
Equipment Design
;
Monitoring, Physiologic/methods*
;
Humans


Result Analysis
Print
Save
E-mail