1.Causal relationship between gut microbiota and viral pneumonia and the mediating role of metabolites:a Mendelian randomization study
Ya-Xuan DU ; Han-Bing JI ; Jie DING ; Jia-Rui BAI ; Xiao-Ling YANG ; Xiao-Man GUO ; Hai-Tao DU
Medical Journal of Chinese People's Liberation Army 2025;50(11):1398-1406
Objective To investigate the causal relationship between gut microbiota and viral pneumonia,as well as the underlying mechanisms,using two-sample and two-step Mendelian randomization(MR)approaches,thereby providing novel insights for the prevention and treatment of viral pneumonia.Methods All data were obtained from publicly available genome-wide association studies(GWAS)pooled datasets,including gut microbiota data from the MiBioGen Consortium and the Netherlands Microbiome Project,viral pneumonia data from the FinnGen R10 database,and plasma metabolome data from the publicly available GWAS Catalog.Instrumental variables(IVs)were extracted according to the predefined threshold values.MR analyses were conducted using inverse variance weighting(IVW),MR-Egger,weighted median(WME),weighted mode(WM),and Bayesian-weighted Mendelian randomization(BWMR)methods.Reverse MR analysis was performed to determine whether there was a reverse association.Two-step MR analysis was used to explore the potential mediating role of plasma metabolites,and a series of sensitivity analyses were performed to test the stability of the results.Results Among 196 gut microbiota taxa from the MiBioGen consortium GWAS,11 taxa were associated with viral pneumonia.An increase in the abundance of 4 taxa increased the risk of viral pneumonia,while an increase in the abundance of 7 taxa had a protective effect against viral pneumonia.Among the 207 gut microbiota taxa from the Dutch Microbiome Project GWAS data,10 taxa were associated with viral pneumonia,with 6 risk-increasing and 4 protective taxa identified.Mediation analysis results showed that the causal effect of Defluviitaleaceae on viral pneumonia(OR=0.708,95%CI 0.540-0.929,P=0.013)was mediated to some extent by the N6-acetyllysine levels,with a mediation ratio of 18.4%.Sensitivity analyses did not reveal significant heterogeneity or horizontal pleiotropy.Conclusions Specific gut microbiota are causally associated with viral pneumonia and show potential differences across different populations;the protective effect of Defluviitaleaceae against viral pneumonia may be mediated by the N6-acetyllysine levels.Targeting metabolites may become a potential therapeutic approach for viral pneumonia.
2.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
3.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
4.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
5.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
6.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
7.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
8.An Enhancer LncRNA Regulates NFE2 Expression and Proliferation in Human Leukemic K562 Cells
Yan-Fei LU ; Song-Ya QU ; Jing-Jing ZHU ; Chao LIU ; Jian WANG ; Bing-She HAN ; Jun-Fang ZHANG
Progress in Biochemistry and Biophysics 2024;51(1):190-201
ObjectiveTranscription factor NFE2 was observed abnormal expression in myeloproliferative neoplasm (MPN) patients. However, how NFE2 is transcriptionally regulated remains ambiguous. This study aims to explore the elements and molecular mechanisms involved in the transcriptional regulation of NFE2. MethodsActive enhancers were predicted by public NGS data and conformed experimentally via dual luciferase reporter assay. After that, PRO-seq and GRO-seq data was used to detect enhancer RNAs transcribed from these enhancers. RACE was utilized to clone the full length enhancer RNA (eRNA) transcripts, and RT-qPCR was used to measure their expression in different leukemia cell lines as well as the transcript levels during induced differentiation. Finally, to investigate the molecular function of the eRNA, overexpression and knockdown of the eRNA via lentivirus system was performed in K562 cells. ResultsWe identified three enhancers regulating NFE2 transcription, which located at -3.6k, -6.2k and +6.3k from NFE2 transcription start site (TSS) respectively. At the -3.6k enhancer, we cloned an eRNA transcript and characterized that as a lncRNA which was expressed and located in the nucleus in three types of leukemia cell lines. When this lncRNA was overexpressed, expression of NFE2 was upregulated and decreases of K562 cell proliferation and migration ability were observed. While knocking down of this lncRNA, the level of NFE2 decreases correspondingly and the proliferation ability of K562 cells increases accordingly. ConclusionWe identified an enhancer lncRNA that regulates NFE2 transcription positively and suppresses K562 cell proliferation.
10.Study on the effect of different administration regimens of iprrazole enteric-coated tablets on inhibiting gastric acid secretion
Ting-Yuan PANG ; Zhi WANG ; Zi-Shu HU ; Zi-Han SHEN ; Yue-Qi WANG ; Ya-Qian CHEN ; Xue-Bing QIAN ; Jin-Ying LIANG ; Liang-Ying YI ; Jun-Long LI ; Zhi-Hui HAN ; Guo-Ping ZHONG ; Guo-Hua CHENG ; Hai-Tang HU
The Chinese Journal of Clinical Pharmacology 2024;40(1):92-96
Objective To compare the effects of 20 mg qd and 10 mg bidadministration of iprrazole enteric-coated tablets on the control of gastric acid in healthy subjects.Methods A randomized,single-center,parallel controlled trial was designed to include 8 healthy subjects.Randomly divided into 2 groups,20 mg qd administration group:20 mg enteric-coated tablets of iprrazole in the morning;10 mg bid administration group:10 mg enteric-coated tablets of iprrazole in the morning and 10 mg in the evening.The pH values in the stomach of the subjects before and 24 h after administration were monitored by pH meter.The plasma concentration of iprazole after administration was determined by HPLC-MS/MS.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin(V8.0)software.Results The PK parameters of iprrazole enteric-coated tablets and reference preparations in fasting group were as follows:The Cmax of 20 mg qd group and 10 mg bid group were(595.75±131.15)and(283.50±96.98)ng·mL-1;AUC0-t were(5 531.94±784.35)and(4 686.67±898.23)h·ng·mL-1;AUC0-∞ were(6 003.19±538.59)and(7 361.48±1 816.77)h·ng·mL-1,respectively.The mean time percentage of gastric pH>3 after 20 mg qd and 10 mg bid were 82.64%and 61.92%,and the median gastric pH within 24 h were 6.25±1.49 and 3.53±2.05,respectively.The mean gastric pH values within 24 h were 5.71±1.36 and 4.23±1.45,respectively.The correlation analysis of pharmacokinetic/pharmacodynamics showed that there was no significant correlation between the peak concentration of drug in plasma and the inhibitory effect of acid.Conclusion Compared with the 20 mg qd group and the 10 mg bid group,the acid inhibition effect is better,the administration times are less,and the safety of the two administration regimes is good.

Result Analysis
Print
Save
E-mail