1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Clinical and genetic characteristics of osteopetrosis in children.
Min WANG ; Ao-Shuang JIANG ; Cheng-Lin ZHU ; Jie WANG ; Ya-Ping WANG ; Shan GAO ; Yan LI ; Tian-Ping CHEN ; Hong-Jun LIU ; Jian WANG
Chinese Journal of Contemporary Pediatrics 2025;27(5):568-573
OBJECTIVES:
To study the clinical and genetic characteristics of osteopetrosis (OPT) in children.
METHODS:
A retrospective analysis was performed on the clinical data of 14 children with OPT. Whole-exome sequencing was used to detect pathogenic genes, and clinical phenotypes and genotypic features were summarized.
RESULTS:
Among the 14 children (10 males and 4 females), the median age at diagnosis was 8 months. Clinical manifestations included systemic osteosclerosis (14 cases, 100%), anemia (12 cases, 86%), infections (10 cases, 71%), thrombocytopenia (9 cases, 64%), hepatosplenomegaly (8 cases, 57%), and developmental delay (5 cases, 36%). Malignant osteopetrosis (MOP) cases had lower platelet counts, creatine kinase isoenzyme, and serum calcium levels, but higher white blood cell counts, lactate dehydrogenase, and alkaline phosphatase levels compared to non-MOP cases (P<0.05). Genetic testing identified 15 variants in 12 patients, including 8 variants in the CLCN7 gene (53%), 6 in the TCIRG1 gene (40%), and 1 in the TNFRSF11A gene (7%). Three novel CLCN7 variants were identified: c.2351G>C, c.1215-43C>T, and c.1534G>A. All four patients with TCIRG1 variants exhibited MOP clinical phenotypes. Of the seven patients with CLCN7 variants, 4 presented with intermediate OPT, 2 with benign OPT, and 1 with MOP.
CONCLUSIONS
Clinical phenotypes of OPT in children are heterogeneous, predominantly involving CLCN7 and TCIRG1 gene variants, with a correlation between clinical phenotypes and genotypes.
Humans
;
Osteopetrosis/genetics*
;
Male
;
Female
;
Infant
;
Child, Preschool
;
Retrospective Studies
;
Vacuolar Proton-Translocating ATPases/genetics*
;
Child
;
Chloride Channels/genetics*
;
Mutation
;
Receptor Activator of Nuclear Factor-kappa B
3.Waist Circumference Status and Distribution in Chinese Adults: China Nutrition and Health Surveillance (2015-2017).
Jing NAN ; Mu Lei CHEN ; Hong Tao YUAN ; Qiu Ye CAO ; Dong Mei YU ; Wei PIAO ; Fu Sheng LI ; Yu Xiang YANG ; Li Yun ZHAO ; Shu Ya CAI
Biomedical and Environmental Sciences 2025;38(6):757-762
4.A Retrospective Study of Pregnancy and Fetal Outcomes in Mothers with Hepatitis C Viremia.
Wen DENG ; Zi Yu ZHANG ; Xin Xin LI ; Ya Qin ZHANG ; Wei Hua CAO ; Shi Yu WANG ; Xin WEI ; Zi Xuan GAO ; Shuo Jie WANG ; Lin Mei YAO ; Lu ZHANG ; Hong Xiao HAO ; Xiao Xue CHEN ; Yuan Jiao GAO ; Wei YI ; Yao XIE ; Ming Hui LI
Biomedical and Environmental Sciences 2025;38(7):829-839
OBJECTIVE:
To investigate chronic hepatitis C virus (HCV) infection's effect on gestational liver function, pregnancy and delivery complications, and neonatal development.
METHODS:
A total of 157 HCV antibody-positive (anti-HCV[+]) and HCV RNA(+) patients (Group C) and 121 anti-HCV(+) and HCV RNA(-) patients (Group B) were included as study participants, while 142 anti-HCV(-) and HCV RNA(-) patients (Group A) were the control group. Data on biochemical indices during pregnancy, pregnancy complications, delivery-related information, and neonatal complications were also collected.
RESULTS:
Elevated alanine aminotransferase (ALT) rates in Group C during early, middle, and late pregnancy were 59.87%, 43.95%, and 42.04%, respectively-significantly higher than Groups B (26.45%, 15.70%, 10.74%) and A (23.94%, 19.01%, 6.34%) ( P < 0.05). Median ALT levels in Group C were significantly higher than in Groups A and B at all pregnancy stages ( P < 0.05). No significant differences were found in neonatal malformation rates across groups ( P > 0.05). However, neonatal jaundice incidence was significantly greater in Group C (75.16%) compared to Groups A (42.25%) and B (57.02%) ( χ 2 = 33.552, P < 0.001). HCV RNA positivity during pregnancy was an independent risk factor for neonatal jaundice ( OR = 2.111, 95% CI 1.242-3.588, P = 0.006).
CONCLUSIONS
Chronic HCV infection can affect the liver function of pregnant women, but does not increase the pregnancy or delivery complication risks. HCV RNA(+) is an independent risk factor for neonatal jaundice.
Humans
;
Female
;
Pregnancy
;
Adult
;
Pregnancy Complications, Infectious/epidemiology*
;
Retrospective Studies
;
Pregnancy Outcome
;
Infant, Newborn
;
Viremia/virology*
;
Hepatitis C
;
Hepacivirus/physiology*
;
Hepatitis C, Chronic/virology*
;
Young Adult
;
Alanine Transaminase/blood*
5.Association of Body Mass Index with All-Cause Mortality and Cause-Specific Mortality in Rural China: 10-Year Follow-up of a Population-Based Multicenter Prospective Study.
Juan Juan HUANG ; Yuan Zhi DI ; Ling Yu SHEN ; Jian Guo LIANG ; Jiang DU ; Xue Fang CAO ; Wei Tao DUAN ; Ai Wei HE ; Jun LIANG ; Li Mei ZHU ; Zi Sen LIU ; Fang LIU ; Shu Min YANG ; Zu Hui XU ; Cheng CHEN ; Bin ZHANG ; Jiao Xia YAN ; Yan Chun LIANG ; Rong LIU ; Tao ZHU ; Hong Zhi LI ; Fei SHEN ; Bo Xuan FENG ; Yi Jun HE ; Zi Han LI ; Ya Qi ZHAO ; Tong Lei GUO ; Li Qiong BAI ; Wei LU ; Qi JIN ; Lei GAO ; He Nan XIN
Biomedical and Environmental Sciences 2025;38(10):1179-1193
OBJECTIVE:
This study aimed to explore the association between body mass index (BMI) and mortality based on the 10-year population-based multicenter prospective study.
METHODS:
A general population-based multicenter prospective study was conducted at four sites in rural China between 2013 and 2023. Multivariate Cox proportional hazards models and restricted cubic spline analyses were used to assess the association between BMI and mortality. Stratified analyses were performed based on the individual characteristics of the participants.
RESULTS:
Overall, 19,107 participants with a sum of 163,095 person-years were included and 1,910 participants died. The underweight (< 18.5 kg/m 2) presented an increase in all-cause mortality (adjusted hazards ratio [ aHR] = 2.00, 95% confidence interval [ CI]: 1.66-2.41), while overweight (≥ 24.0 to < 28.0 kg/m 2) and obesity (≥ 28.0 kg/m 2) presented a decrease with an aHR of 0.61 (95% CI: 0.52-0.73) and 0.51 (95% CI: 0.37-0.70), respectively. Overweight ( aHR = 0.76, 95% CI: 0.67-0.86) and mild obesity ( aHR = 0.72, 95% CI: 0.59-0.87) had a positive impact on mortality in people older than 60 years. All-cause mortality decreased rapidly until reaching a BMI of 25.7 kg/m 2 ( aHR = 0.95, 95% CI: 0.92-0.98) and increased slightly above that value, indicating a U-shaped association. The beneficial impact of being overweight on mortality was robust in most subgroups and sensitivity analyses.
CONCLUSION
This study provides additional evidence that overweight and mild obesity may be inversely related to the risk of death in individuals older than 60 years. Therefore, it is essential to consider age differences when formulating health and weight management strategies.
Humans
;
Body Mass Index
;
China/epidemiology*
;
Male
;
Female
;
Middle Aged
;
Prospective Studies
;
Rural Population/statistics & numerical data*
;
Aged
;
Follow-Up Studies
;
Adult
;
Mortality
;
Cause of Death
;
Obesity/mortality*
;
Overweight/mortality*
6.Visualization and Analysis of Sweat Pore Features in Latent Fingerprints Using Core-Shell Structured Composite Nanofibrous Membrane
Shi-Yue MA ; Ya-Li PEI ; Hong-Yu CHEN ; Xin DU ; Yan-Feng ZHANG ; Rong-Liang MA ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(8):1269-1278
Introducing fingerprint level 3 features(especially sweat pores)in fingerprint recognition can significantly improve the value of fingerprints.However,conventional fingerprint visualization methods suffer from issues such as poor stability and reproducibility,insufficient resolution,and feature masking in detecting level 3 features.Electrospun membrane has unique advantages in latent fingerprint(LFP)detection due to its excellent adsorption performance and high specific surface area,and thus its application potential in LFP visualization urgently need to be explored.A novel pore visualization method based on core-shell structured PAN-Flu/PVP composite nanofibrous membrane was proposed in this work.Specifically,the PAN-Flu/PVP composite nanofibrous membrane was prepared via coaxial electrospinning technology,with polyacrylonitrile(PAN)loaded with fluorescein(Flu)as the core and polyvinylpyrrolidone(PVP)as the shell.The experimental results showed that the prepared PAN Flu/PVP composite nanofibrous membrane had a porous structure and excellent adsorption performance.Based on the water solubility of the outer shell PVP and the water induced fluorescence enhancement effect of the core Flu,high-resolution visualization of sweat pores could be achieved within 2 s.The optimization experiment showed that the best quality of sweat latent fingerprints was obtained when the Flu content was 4 mg/mL,the spinning time was 1 h,and the sweating time was 2 min.Through repeated fingerprinting and live fingerprint comparison experiment,the strong stability and high reproducibility of the as-produced membrane in displaying fingerprint sweat pores were finally verified.In summary,the development method could quickly,stably and accurately extract the spatial distribution and activity level of fingerprint sweat pores,which was of great significance for improving the utilization and value of fingerprints.
7.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
8.Qualitative systematic evaluation of influencing factors for implementation of clinical practice guidelines in China based on theoretical domains framework.
Xu-Dong ZHANG ; Ju-Wen ZHANG ; Fan-Ya YU ; Jun-Hong YU ; Wei CHEN
China Journal of Chinese Materia Medica 2025;50(13):3803-3814
The effective implementation of clinical practice guideline(CPG), as a crucial vehicle of evidence-based medicine, plays a vital role in improving healthcare quality and patient safety. Currently, there remains a significant gap between the actual implementation outcomes of traditional Chinese medicine(TCM) guidelines and their intended objectives, which necessitates a systematic investigation into their influencing factors to optimize implementation strategies. This study aims to comprehensively identify the factors influencing CPG implementation in China, adapt the theoretical domains framework(TDF) to the local context, and integrate TCM-specific characteristics to provide recommendations for optimizing the development and implementation processes of TCM guidelines. Systematic search was conducted across multiple databases, including CNKI, Wanfang, VIP, SinoMed, PubMed, and EMbase, covering the period from each database's inception to March 2024. Qualitative and mixed-methods studies were included to examine factors affecting the implementation of clinical practice guidelines. The methodological quality of the included studies was assessed using the critical appraisal skills programme(CASP) tool. RESULTS:: were synthesized through framework analysis and thematic synthesis, and expert consensus was achieved via a structured consensus meeting. A total of 16 studies involving 2 388 participants were included with overall good methodological quality. Based on the TDF, 43 influencing factors across 14 domains were identified. The most critical factors included the quality of guideline evidence, training and academic conferences organized by hospitals and academic institutions to promote guideline adoption among medical staff, support from professional leaders for guideline implementation, the applicability and clarity of guideline recommendations, and material resources(supplies, funding, and facilities) required for implementation. Additionally, influencing factors of TCM guideline implementation were identified, including the distinctive advantages of TCM therapies, the applicability of syndrome differentiation, and the feasibility of TCM treatments. Based on these findings, it is recommended that TCM guideline development should incorporate these unique influencing factors to formulate high-quality, clear, and actionable recommendations. Following guideline publication, healthcare and academic institutions should strengthen training and dissemination efforts and ensure the availability of necessary implementation resources to facilitate the successful adoption of guidelines in clinical practice.
China
;
Humans
;
Practice Guidelines as Topic
;
Medicine, Chinese Traditional/standards*
;
Evidence-Based Medicine
9.Application of Assessment Scales in Palliative Care for Glioma: A Systematic Review.
Zhi-Yuan XIAO ; Tian-Rui YANG ; Ya-Ning CAO ; Wen-Lin CHEN ; Jun-Lin LI ; Ting-Yu LIANG ; Ya-Ning WANG ; Yue-Kun WANG ; Xiao-Peng GUO ; Yi ZHANG ; Yu WANG ; Xiao-Hong NING ; Wen-Bin MA
Chinese Medical Sciences Journal 2025;40(3):211-218
BACKGROUND AND OBJECTIVE: Patients with glioma experience a high symptom burden and have diverse palliative care needs. However, the assessment scales used in palliative care remain non-standardized and highly heterogeneous. To evaluate the application patterns of the current scales used in palliative care for glioma, we aim to identify gaps and assess the need for disease-specific scales in glioma palliative care. METHODS: We conducted a systematic search of five databases including PubMed, Web of Science, Medline, EMBASE, and CINAHL for quantitative studies that reported scale-based assessments in glioma palliative care. We extracted data on scale characteristics, domains, frequency, and psychometric properties. Quality assessments were performed using the Cochrane ROB 2.0 and ROBINS-I tools. RESULTS: Of the 3,405 records initially identified, 72 studies were included. These studies contained 75 distinct scales that were used 193 times. Mood (21.7%), quality of life (24.4%), and supportive care needs (5.2%) assessments were the most frequently assessed items, exceeding half of all scale applications. Among the various assessment dimensions, the Distress Thermometer (DT) was the most frequently used tool for assessing mood, while the Short Form-36 Health Survey Questionnaire (SF-36) was the most frequently used tool for assessing quality of life. The Mini Mental Status Examination (MMSE) was the most common tool for cognitive assessment. Performance status (5.2%) and social support (6.8%) were underrepresented. Only three brain tumor-specific scales were identified. Caregiver-focused scales were limited and predominantly burden-oriented. CONCLUSIONS: There are significant heterogeneity, domain imbalances, and validation gaps in the current use of assessment scales for patients with glioma receiving palliative care. The scale selected for use should be comprehensive and user-friendly.
Humans
;
Glioma/psychology*
;
Palliative Care/methods*
;
Quality of Life
;
Psychometrics
;
Brain Neoplasms/psychology*
10.A comparative study on the current status of disability assessment and long-term care needs assessment in 49 pilot cities of the long-term care insurance system
Jiali ZHANG ; Hongxiu CHEN ; Yilin WANG ; Ya LIU ; Shihao XU ; Yanyan WANG ; Birong DONG ; Hong SUN ; Xiuying HU
Chinese Journal of Nursing 2025;60(19):2384-2390
Objective To analyze the disability level and long-term care needs assessment policies issued by 49 pilot cities in China's long-term care insurance system,providing insights for further improvement of the system.Methods Policy documents related to long-term care insurance,published between June 2016 and December 2024 on official platforms of local governments,the Ministry of Human Resources and Social Security,the National Healthcare Security Administration,and the National Public Service Platform for Standards Information,were retrieved.A comparative analysis was used to summarize and compare the content of these policy texts.Results Currently,there are 49 pilot cities implementing the long-term care insurance system in China.47 cities have issued disability level assessment standards,with 38 cities adopting the trial standards issued by the National Healthcare Security Administration.In 42 pilot cities,the disability level assessment includes indicators such as activities of daily living,cognitive function,and sensory and communication abilities.22 cities have issued policies related to care needs assessment.In most cities,the care needs assessment partially or fully includes indicators from the disability level assessment.Conclusion There is no national uniformity in disability level assessment standards,and the care needs assessment framework needs further improvement.It is recommended to standardize disability level assessment criteria,clearly delineate the boundaries and content of disability level and care needs assessments,and enhance the development of the care needs assessment system.

Result Analysis
Print
Save
E-mail