1.Comparison between ultrafiltration and dextran gel method in the purification of Tfn/PCL micelles
Lingbo YU ; Yadong ZHANG ; Rui XU ; Yuyu SUN ; Huiyun WANG ; Jinjin YANG ; Yanan CUI
Acta Universitatis Medicinalis Anhui 2026;61(2):258-263
ObjectiveTo compare the differences between the ultrafiltration method and the dextran gel filtration method during the purification of Tfn-modified PCL micelles by using purification efficiency and micelle purity as indicators. MethodsCoumarin-6 (C6) was used as a fluorescent probe and was loaded into HOOC-PEG-PCL to form PCL micelles by the film-dispersion method. Tfn was then conjugated to the surface of PCL micelles via an amidation reaction, resulting in two types of micelles: Tfn/PCLH and Tfn/PCLL. The pharmaceutical properties of the two types of micelles were characterized. The micelles were then purified through ultrafiltration method and dextran gel method respectively, and the efficiency of the two methods, along with the purity of the final micelles, was compared. The density of Tfn on the surface of PCL micelles was also calculated. ResultsThe hydrated diameter of PCL micelles was approximately 73 nm, and the C6 loading efficiency was around 0.046%. The size increased to 134 nm and 158 nm for Tfn/PCLL and Tfn/PCLH, respectively. The micelle population was monodisperse. The purification results showed that, for the ultrafiltration method, after two and one rounds of purification, the Tfn/C6 ratio stabilized at 23.6 and 3.4 for Tfn/PCLH and Tfn/PCLL, respectively. For the dextran gel filtration method, the Tfn/C6 ratio reached 23.7 for the Tfn/PCLH group after two rounds of purification. However, for the Tfn/PCLL group, the Tfn/C6 ratio increased during four rounds of dextran gel purification, and a significant difference (P = 0.042 4) was observed between the first and last filtrations. The density of Tfn in the final micelles were calculated. For the ultrafiltration method, the Tfn density of Tfn/PCLH and Tfn/PCLL were 94.9% and 13.8%, respectively. For the dextran gel filtration method, the density of the two micelles were 95.6% and 14.4%, respectively. For Tfn/PCLL group, the density results revealing a statistically significant difference (P=0.000 2). ConclusionThe purification efficiency of the two methods is comparable. However, the purity of the final micelles shows a significant difference, with the dextran gel filtration method resulting in higher purity, particularly for the Tfn/PCLL micelles.
2.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
3.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
4.Effect of Transcutaneous Electrical Acupoint Stimulation on Stress Response in Patients Undergoing Unilateral Biportal Endoscopy
Yanan LI ; Zhengzuo WAN ; Xueliang DONG ; Shiyi TANG ; Xuelai YU
Journal of Traditional Chinese Medicine 2026;67(10):1071-1077
ObjectiveTo explore the effect of transcutaneous electrical acupoint stimulation (TEAS) on stress response in patients undergoing unilateral biportal endoscopy (UBE) and to identify optimal TEAS parameters. MethodsA total of 96 patients undergoing UBE were randomly grouped into total intravenous anesthesia (TIVA) group, acupuncture-assisted anesthesia with continuous waves (AACW) group, and acupuncture-assisted anesthesia with sparse-dense waves (AASDW) group, with 32 patients per group. All groups were given a standardized TIVA protocol. In the AACW group (100 Hz continuous wave stimulation) and the AASDW group (2/100 Hz sparse-dense wave stimulation), TEAS intervention was applied to both bilateral Zusanli (ST36) and Sanyinjiao (SP6) 30 minutes before TIVA induction and continued until the end of the surgery. In the TIVA group, electrodes were only connected without electrical stimulation. The stress response indicators including cortisol (Cor) and adrenocorticotropic hormone (ACTH), heart rate (HR), mean arterial pressure (MAP), and bispectral index (BIS) at before anesthesia induction (T0), after tracheal intubation (T1), during laminectomy (T2), and 1 hour after surgery (T3) were compared across groups. The operation duration, anesthesia duration, extubation and recovery duration were recorded, as well as pain intensity including visual analogue scale (VAS), and sedation level (by Ramsay sedation score) at 2, 6, 12 hours after surgery, and postoperative complications. ResultsThe AACW group and AASDW group had lower ACTH and COR levels at T1, T2 and T3, as well as lower HR and MAP levels at T1 and T2 than TIVA group, with AASDW group being lower than AACW group (P<0.05). At T3, the AASDW group had higher BIS than TIVA group and AACW group (P<0.05). No significant difference in operation duration was observed (P>0.05). The AACW group and AASDW group had shorter anesthesia, extubation and recovery duration than TIVA group, with AASDW group being the shortest (P<0.05). The VAS scores at 2 h, 6 h, and 12 h after surgery in the AACW and AASDW groups were lower than those in the TIVA group, with the AASDW group showing significantly lower scores than the AACW group (P<0.05). The Ramsay sedation scores in the AASDW group were lower than those in the AACW group at 2 h and 6 h after surgery (P<0.05). The total incidence of complications in the AASDW group was 6.25% (2/32), significantly lower than 28.13% (9/32) in the TIVA group (P<0.05). ConclusionTEAS can effectively suppresses stress response in patients undergoing UBE, with the 2/100 Hz sparse-dense wave parameter being most effective, which can stabilize hemodynamics, accelerate recovery, improve postoperative sedation and analgesia quality, and reduces complications.
5.Construction of the Theoretical Model of the "Manipulative Effect Units" and Its Application in Complex Interventions of Manual Medicine
Yanan SUN ; Qun NIU ; Changhe YU
Journal of Traditional Chinese Medicine 2026;67(13):1365-1372
Drawing on the concepts of behavioural change taxonomies and theoretical coding schemes, this paper designs a theoretical model of "manipulative effect units" for manual medicine, establishing a logical framework that links "treatment objectives (theory-driven)-treatment techniques (precise implementation)-expected effects (immediate verification)". First, it analyses the methodological challenges faced by manual medicine as a complex intervention, reviewing the insights and limitations of existing research frameworks. It then focuses on the model's core concepts, theoretical architecture and multi-level coding system of "manipulative effect units", illustrating its application logic using tuina for knee osteoarthritis as an example. Finally, it proposes a development pathway of "manipulative effect units" model in complex interventions based on consensus, technological integration and artificial intelligence. This model aims to provide a unified methodological foundation for the standardised description, reproducible research and identification of active components in manual interventions, thereby propelling manual medicine from empirical transmission towards a new phase guided by theory and evidence optimization.
6.Analysis of thyroid examination results among interventional radiation workers in Tianjin from 2020 to 2022
Yanan DU ; Pei HAO ; Jinglin YU ; Jinwei YU ; Lina FAN ; Xueying YANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(8):610-614
Objective:To investigate and analyze the thyroid examination results and influencing factors of interventional radiation workers in Tianjin.Methods:In February 2023, A convenient sampling method was used to select the staff engaged in interventional radiation work in an occupational health inspection institution in Tianjin from 2020 to 2022 as the study object. After excluding the incomplete data, 1080 people were included, and 363 medical staff with non-radiological work during the same period were included as the control group. To analyze the individual doses and occupational health examination data of interventional radiation workers, and to analyze the possible influencing factors of thyroid abnormalities.Results:The cumulative dose M ( Q1, Q3) of interventional radiation workers was 1.039 (0.528, 1.905) mSv. The levels of FT 3 and FT 4 in the intervention group were higher than those in the control group, while TSH levels were lower than those in the control group ( Z=4.84、6.03、-5.82, P<0.05). The levels of FT 3 and FT 4 in female interventional radiation workers were lower than those in males, while the levels of TSH were higher than those in males ( Z= -17.54、-6.65、3.61, P<0.05). There were statistically significant differences in FT 3 levels among different ages, differen tradiation exposure years, different initial age of exposure to radiation, and different cumulative doses ( H=47.22、11.33、16.70, Z=-2.48, P<0.05). There were statistically significant differences in thyroid ultrasound abnormalities among different genders, different ages, different initial age of exposure to radiation, and different cumulative doses ( χ2=28.02、61.12、17.87、11.30, P<0.05). The results of logistic regression analysis showed that the influencing factors of FT 3 distributed in the low-level group were female ( OR=10.53, 95% CI: 7.66-14.47, P<0.05), and age 40-49, ≥50 years old ( OR=2.40, 95% CI: 1.12-5.14 OR=3.79, 95% CI: 1.59-9.03, P<0.05). The influencing factors of thyroid ultrasound abnormalities were female ( OR=1.92, 95% CI: 1.48-2.50, P<0.05) and age ≥50 years old ( OR=3.93, 95% CI: 1.91-8.09, P<0.05) . Conclusion:Long term low dose ionizing radiation has a certain effect on FT 3, FT 4 and TSH levels of interventional radiation workers. Gender and increased age are possible influencing factors of the decreased FT 3 levels and thyroid ultrasound abnormalities.
7.Mediating effects of cardiovascular health status in association between educational level and cardiovascular disease
Yanan WU ; Minhua TANG ; Biying WANG ; Yiling WU ; Liping YI ; Hongjie YU ; Yunlong KAN ; Shuai ZHU ; Xiaohua LIU ; Yonggen JIANG ; Genming ZHAO
Chinese Journal of Epidemiology 2025;46(5):840-849
Objective:To analyze the mediating effect of cardiovascular health status (CVH) on the association between educational level and cardiovascular disease (CVD).Methods:The participants were from Shanghai Suburban Adult Cohort and Biobank, and questionnaire survey, physical examination, blood biochemistry were conducted from 2016 to 2020 for baseline information collection, and follow up was conducted until March 31, 2024 based on the medical data, CVD incidence data and death surveillance data at different levels. The associations of educational level, CVH and time to CVD onset of the study population were analyzed using the accelerated failure time model to analyze the mediating effects of CVH, health behaviors, and health factors in the association of educational level and time to CVD onset. The mediating effects of educational level, gender, and age moderated associations were also analyzed.Results:A total of 57 312 participants were included, with 2 780 new cases of CVD during a median follow-up of 6.71 (6.71-6.72) years, and a mean incidence density of 7.77/1 000 person-years (95% CI: 7.48/1 000 person-years -8.06/1 000 person-years). In total, the less educational level and the lower CVH, the higher CVD incidence density ( P<0.05). The results of accelerated failure time models showed that the time ratio for CVD-free survival was 1.15 (95% CI: 1.06-1.24) and 1.33 (95% CI: 1.10-1.60) for moderate and high educational level, respectively. The results of the mediation effect analysis showed that the association between moderate and high educational level and time to CVD onset was 29.60% (20.50%-50.00%) and 36.10% (23.80%-59.00%), 9.97% (5.07%-20.00%) and 13.84% (6.84%-29.00%), 15.24% (9.64%-27.00%) and 17.55% (11.58%-33.00%) of mediators mediated by CVH, health behaviors, health factors, respectively. Among them, there was an exposure-mediated interaction of educational level and a positive moderating effect of age. Conclusion:CVH, health behaviors and health factors had a proportionate mediating effect in the association between educational level and risk of CVD development.
8.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
9.Chinese expert consensus on the evaluation of allergen-specific immunotherapy outcomes(Wuhan, 2025).
Yuqin DENG ; Xi LUO ; Zhuofu LIU ; Shuguang SUN ; Jing YE ; Tiansheng WANG ; Jianjun CHEN ; Meiping LU ; Yin YAO ; Ying WANG ; Wei ZHOU ; Bei LIU ; Qingxiang ZENG ; Yuanteng XU ; Qintai YANG ; Yucheng YANG ; Feng LIU ; Chengli XU ; Yanan SUN ; Haiyu HONG ; Haibo YE ; Liqiang ZHANG ; Fenghong CHEN ; Huabin LI ; Hongtian WANG ; Yuncheng LI ; Wenlong LIU ; Yu XU ; Hongfei LOU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1075-1085
Allergen-specific immunotherapy(AIT) remains the only therapeutic approach with the potential to modify the natural course of allergic rhinitis(AR). Nevertheless, considerable inter-individual variability exists in patients'responses to AIT. To facilitate more reliable assessment of treatment efficacy, the China Rhinopathy Research Cooperation Group(CRRCG) convened young and middle-aged nasal experts in China to formulate the present consensus. The recommended subjective outcome measures for AIT comprise symptom scores, medication scores, combined symptom and medication scores, quality-of-life assessments, evaluation of disease control, and assessment of comorbidities. Objective indicators may supplement these measures. Currently available objective approaches include skin prick testing, nasal provocation testing, and allergen exposure chambers. However, these methods remain constrained by practical limitations and are not yet appropriate for routine implementation in clinical efficacy evaluation. In addition, several biomarkers, including sIgE and the sIgE/tIgE ratio, sIgG4, serum IgE-blocking activity, IgA, cytokines and chemokines, as well as immune cell surface molecules and their functional activity, have been shown to have associations with AIT outcomes. While these biomarkers may complement subjective assessments, they are subject to significant limitations. Consequently, large-scale multicenter trials and real-world evidence are required to strengthen the evidence base. The present consensus underscores the necessity of integrating patients'subjective experiences with objective testing throughout the treatment process, thereby providing a more comprehensive and accurate framework for efficacy evaluation. Looking forward, future investigations should prioritize the incorporation of multi-omics data and artificial intelligence methodologies, which hold promise for overcoming current limitations in assessment strategies and for advancing both the standardization and personalization of AIT.
Humans
;
Allergens/immunology*
;
China
;
Consensus
;
Desensitization, Immunologic
;
Immunoglobulin E
;
Quality of Life
;
Rhinitis, Allergic/therapy*
;
Treatment Outcome
;
East Asian People
10.Clinical Safety Monitoring of 3 035 Cases of Juvenile Feilike Mixture After Marketing in Hospital
Jian ZHU ; Zhong WANG ; Jing LIU ; Jun LIU ; Wei YANG ; Yanan YU ; Hongli WU ; Sha ZHOU ; Zhiyu PAN ; Guang WU ; Mengmeng WU ; Zhiwei JING
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):194-200
ObjectiveTo explore the clinical safety of Feilike Mixture (FLK) in the real world. MethodsThe safety of all children who received FLK from 29 institutions in 12 provinces between January 21,2021 and December 25,2021 was evaluated through prospective centralized surveillance and a nested case control study. ResultsA total of 3 035 juveniles were included. There were 29 research centers involved,which are distributed across 12 provinces,including one traditional Chinese medicine (TCM) hospital and 28 general hospitals. The average age among the juveniles was (4.77±3.56) years old,and the average weight was (21.81±12.97) kg. Among them,119 cases (3.92%) of juveniles had a history of allergies. Acute bronchitis was the main diagnosis for juveniles,with 1 656 cases (54.46%). FLK was first used in 2 016 cases (66.43%),and 142 juvenile patients had special dosages,accounting for 4.68%. Among them,92 adverse drug reactions (ADRs) occurred,including 73 cases of gastrointestinal system disorders,10 cases of metabolic and nutritional disorders,eight cases of skin and subcutaneous tissue diseases,two cases of vascular and lymphatic disorders,and one case of systemic diseases and various reactions at the administration site. The manifestations of ADRs were mainly diarrhea,stool discoloration,and vomiting,and no serious ADRs occurred. The results of multi-factor analysis indicated that special dosages (the use of FLK)[odds ratio (OR) of 2.642, 95% confidence interval (CI) of 1.105-6.323],combined administration: spleen aminopeptide (OR of 4.978, 95%CI of 1.200-20.655),and reason for combined administration: anti-infection (OR of 1.814, 95%CI of 1.071-3.075) were the risk factors for ADRs caused by FLK. Conclusion92 ADRs occurred among 3 035 juveniles using FLK. The incidence of ADRs caused by FLK was 3.03%,and the severity was mainly mild or moderate. Generally,the prognosis was favorable after symptomatic treatment such as drug withdrawal or dosage reduction,suggesting that FLK has good clinical safety.

Result Analysis
Print
Save
E-mail