1.Secondary aesthetic restoration of tetracycline-stained teeth with incongruous gingival margins by digitally guided precision crown lengthening: a case report and literature review
LING Huiling ; SUN Jiyu ; REN Wei ; YUE Li ; RUAN Yifeng ; QIN Ziqi ; GAN Xueqi
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(9):784-791
Objective:
To evaluate the clinical efficacy of digitally guided precision crown lengthening in secondary aesthetic rehabilitation cases, and to provide a clinical reference for digitally guided crown lengthening procedures and secondary aesthetic restorations.
Methods:
We present a case of a patient with tetracycline-stained teeth, partial detachment of anterior resin veneers, and gingival margin discrepancies. The patient underwent digitally guided precision crown lengthening followed by secondary aesthetic rehabilitation. Multimodal data, including intraoral, facial, and CBCT scans, were integrated to construct a four-dimensional virtual patient model (incorporating teeth, face, bone, and occlusion) for surgical planning and 3D-printed guide fabrication. Secondary aesthetic restoration was performed after achieving stable post-surgical outcomes. Based on this case, we conducted a detailed analysis and reviewed relevant literature on crown lengthening in secondary aesthetic rehabilitation.
Results:
The gingival contour of the anterior teeth exhibited significant improvement, with enhanced symmetry and stable gingival margin positioning that closely matched the preoperative design. The crown lengthening procedure demonstrated high precision, and the final outcome was aesthetic and functional. Literature review indicated that secondary restorations frequently present challenges such as gingival contour discrepancies and inflammation. Aesthetic crown lengthening in the anterior region should optimize both soft and hard tissue morphology to meet aesthetic standards, with digital technology improving procedural accuracy.
Conclusion
Precision crown lengthening effectively addresses gingival margin discrepancies in secondary aesthetic rehabilitation, ensuring stable gingival positioning and superior aesthetic outcomes. This approach is particularly suitable for cases with high aesthetic demands.
2.Treatment based on meridian differentiation and its application in clinical acupuncture research: reflections and recommendations.
Jing HE ; Cong CHE ; Ying ZHOU ; Xueqi TENG ; Hongxiu CHEN ; Jialin JIA ; Tie LI
Chinese Acupuncture & Moxibustion 2025;45(5):708-712
Treatment based on meridian differentiation is a characteristic method in clinical acupuncture diagnosis and treatment. Accurately defining and explaining its main content and core concepts is essential for effective clinical guidance. This paper reviews the historical and contemporary understanding, concepts, and primary content of treatment based on meridian differentiation. It proposes a four-step process for clinical application: meridian examination, treatment based on meridian differentiation, acupoint selection, and appropriate treatment methods, with TCM syndrome differentiation applied throughout. Constructing a diagnostic and treatment system which is based on meridian differentiation and suited to clinical acupuncture is significant for enhancing therapeutic efficacy and maximizing the benefits of acupuncture in disease treatment.
Humans
;
Meridians
;
Acupuncture Therapy/methods*
;
Acupuncture Points
;
Medicine, Chinese Traditional
3.Clinical Values of Combined Detection of SerumCystatin C, β2-Microglobulin, and Urine Transferrin in Diagnosing Early Primary Glomerulonephritis
Xueqi ZHANG ; Xueying BAO ; Cuicui WU ; Binxian LI ; Mingcheng LI
Annals of Laboratory Medicine 2025;45(3):329-333
Despite primary glomerulonephritis (PGN) being a leading cause of chronic kidney disease and end-stage renal disease, specific and sensitive biomarkers for the early detection and monitoring of this condition are lacking. We evaluated the value of the combined detection of serum cystatin C (CYSC), β2-microglobulin (β2-MG), and urine transferrin (TRF) for diagnosing early-stage PGN. From May 2021 to May 2023, we enrolled 105 patients in our hospital as the observation group and 50 healthy volunteers as the control group. Their serum expression levels of CYSC, β2-MG, and TRF were evaluated. We plotted separate ROC curves and calculated the area under the curve (AUC) values of CYSC, β2-MG, and TRF to assess their diagnostic performance in PGN. The levels of CYSC, β2-MG, and TRF were significantly higher (P < 0.05) in the observation group than in the healthy control group. CYSC, β2-MG, and TRF were expressed at significantly higher levels in G2, G3a, and G3b of PGN than in G1. The combined use of CYSC, β2-MG, and TRF as biomarkers could significantly improve the early diagnosis and monitoring of PGN and may lead to better patient outcomes by facilitating earlier intervention and treatment strategies.
4.Evaluation of a prediction model for the risk of acute urinary retention in elderly hip fracture patients in the Emergency Care
Ran BI ; Xueqi LI ; Lan GUAN ; Zhaoxing TIAN
Chinese Journal of Emergency Medicine 2024;33(8):1172-1177
Objective:To establishing a clinical prediction model can assist clinicians in identifying at-risk patients early and intervening promptly to decrease AUR incidence.Methods:A retrospective collection of 313 elderly patients with hip fracture treated between 1st July and 31st August 2023 at the Emergency Department of our hospital. Patients were categorised into two groups: The AUR group (45 patients) and the non-AUR group (268 patients) based on the presence or absence of AUR. Basic characteristics, laboratory indicators and bladder volume were compared between the two groups. Factors independently associated with the incidence of AUR were analysed using Logistic regression. Analysis of the independent risk factors impacting the occurrence of AUR, development of a clinical prediction model for the risk of AUR in elderly patients with hip fractures, and internal validation of the model.Results:Comorbid psycho-behavioural symptoms of dementia ( OR=3.334, 95% CI 1.258-8.839, P=0.015), use of hypnotic sedatives ( OR=6.758, 95% CI 2.184-20.912, P=0. 001), increased heart rate ( OR=1.041, 95% CI 1.013-1.070, P=0.004), and increased bladder volume ( OR=1.005, 95% CI 1.004-1.007, P<0.01) were all identified as risk factors. The study identified independent risk factors for AUR in elderly patients who suffered a hip fracture. Based on these factors, the research team developed a prediction model which underwent internal validation using the Bootstrap method. The analysis indicated that the model’s prediction curves aligned closely with the standard model curves. The average absolute error was 0.021. The study's ROC results showed an AUC of 0.083 and a 95% CI of 0.767-0.909. Conclusions:Comorbid psycho-behavioural symptoms of dementia, the use of hypnotic sedative drugs, an increased heart rate, and an increased bladder volume are independent risk factors for the occurrence of AUR in elderly patients who have suffered a hip fracture. The creation of a chart prediction model using columns allows for a visual evaluation of the likelihood of AUR in elderly patients with hip fractures. This model provides important reference material for emergency physicians.
5.Clinical value of multiparameteric quantitative ultrasound for assessing high-risk steatohepatitis
Xueqi LI ; Guangwen CHENG ; Xiaohui QIAO ; Liyun XUE ; Chong HUANG ; Xianjue HUANG ; Qiyuan YAO ; Hong DING
Chinese Journal of Hepatology 2024;32(9):820-827
Objective:To investigate the clinical value of multiparameteric quantitative ultrasound combined with a non-invasive prediction model for assessing high-risk steatohepatitis.Methods:One hundred and ninety-four cases with metabolic-associated fatty liver disease (MAFLD) who underwent liver biopsy in Huashan Hospital, Fudan University, from June 2021 to September 2022 were selected. Shear wave elastography (SWE), shear wave dispersion (SWD) imaging, and attenuation imaging (ATI) examinations were conducted in all patients before biopsy. High-risk steatohepatitis was defined as a total activity score of ≥4 in patients with steatohepatitis, hepatocellular ballooning, and liver lobular inflammation based on pathological hepatic steatosis, inflammatory activity, and fibrosis scoring system (SAF), and fibrosis stage≥F2. Binary logistic regression analysis was used to identify the factors influencing high-risk steatohepatitis. A predictive model for diagnosing high-risk steatohepatitis was constructed using R language. The DeLong test was used to compare the area under the curve between groups. Measurement data was compared between groups using the t-test or rank-sum test, and count data were compared between groups using the χ2 test. Results:There were 46 cases (23.7%) with high-risk steatohepatitis. The quantitative ultrasound parameters included elastic modulus ( OR=2.958, 95% CI: 1.889-4.883, P<0.001), dispersion coefficient ( OR=1.786, 95% CI: 1.424-2.292, P<0.001) and attenuation coefficient ( OR=42.642, 95% CI: 3.463-640.451, P=0.004). Serological indexes of fasting blood glucose ( OR=1.196, 95% CI: 1.048-1.392, P=0.011), alanine aminotransferase ( OR=1.012, 95% CI: 1.006-1.019, P<0.001), aspartate aminotransferase ( OR=1.027, 95% CI: 1.014-1.042, P<0.001), γ-glutamyl transferase ( OR=1.008, 95% CI: 1.001-1.017, P=0.041) and HDL cholesterol ( OR=0.087, 95% CI: 0.016-0.404, P=0.003) were the factors influencing its progression. The AUCs of elastic modulus, dispersion coefficient, attenuation coefficient, multiparametric ultrasound model, serological index model, and ultrasound combined with serology model for the diagnosis of high-risk steatohepatitis were 0.764, 0.758, 0.634, 0.786, 0.773 and 0.825, respectively. The results of the DeLong test showed that the ultrasound combined with the serological model was significantly better than the serological index model and the elastic modulus, dispersion coefficient, and attenuation coefficient alone ( P=0.024, 0.027, 0.038 and <0.001). Conclusion:The combination of multiparametric quantitative ultrasound is helpful for the non-invasive diagnosis of high-risk steatohepatitis and possesses great clinical significance.
6.Digital repair for a patient with limited mouth opening:a case report and literature review
Zhenghao YANG ; Xiting ZHU ; Chen LI ; Min ZHOU ; Xueqi GAN
Journal of Prevention and Treatment for Stomatological Diseases 2024;(3):216-222
Objective To explore an accurate method to obtain an intraoral model of patients with specific limited mouth opening(microstomia)due to systemic scleroderma.Methods This study followed medical ethics,and informed consent has been obtained from patients.A case of Ken's Type Ⅰ mandibular dentition defect scleroderma with limited mouth opening was addressed with digital technology as the leading method combined with the traditional impression method of segmental impression.Individual trays were made based on the patient's left and right mandibular dentition,and segmented molds were obtained.Simultaneously,intraoral scanning was performed to obtain the morphological data of both the soft and hard tissues of the upper and lower mandibles.After each part of the model was obtained,the man-dibular model was scanned and digitally aligned to form the final denture model,and the final removable partial denture was designed and made by computer aided design/computer aided manufacturing(CAD/CAM)technology.At the same time,combined with the literature,the diagnosis and treatment of removable partial denture in patients with limited mouth opening were retrospectively analyzed.Results The denture was well retained and achieved a good repair ef-fect.The patients expressed satisfaction with the mastication efficiency and other functions of the denture.The findings of the literature review show that the integration of digital technology with the traditional impression method,along with computer fitting,can accurately obtain the patient's oral model and facilitate successful follow-up repairs.However,when the anterior mandibular dentition of the patient is absent,the margin of error is increased in this procedure,which deserves further exploration.Conclusion Utilizing digital technology as the leading method,combined with the tradi-tional impression method of segmental impression,for the repair of dental defects in patients with limited mouth open-ing,has proven to be effective.Thus,patients report a positive medical experience with high satisfaction,indicating that this approach is worthy of clinical promotion.
7.Digital repair for a patient with limited mouth opening:a case report and literature review
Zhenghao YANG ; Xiting ZHU ; Chen LI ; Min ZHOU ; Xueqi GAN
Journal of Prevention and Treatment for Stomatological Diseases 2024;(3):216-222
Objective To explore an accurate method to obtain an intraoral model of patients with specific limited mouth opening(microstomia)due to systemic scleroderma.Methods This study followed medical ethics,and informed consent has been obtained from patients.A case of Ken's Type Ⅰ mandibular dentition defect scleroderma with limited mouth opening was addressed with digital technology as the leading method combined with the traditional impression method of segmental impression.Individual trays were made based on the patient's left and right mandibular dentition,and segmented molds were obtained.Simultaneously,intraoral scanning was performed to obtain the morphological data of both the soft and hard tissues of the upper and lower mandibles.After each part of the model was obtained,the man-dibular model was scanned and digitally aligned to form the final denture model,and the final removable partial denture was designed and made by computer aided design/computer aided manufacturing(CAD/CAM)technology.At the same time,combined with the literature,the diagnosis and treatment of removable partial denture in patients with limited mouth opening were retrospectively analyzed.Results The denture was well retained and achieved a good repair ef-fect.The patients expressed satisfaction with the mastication efficiency and other functions of the denture.The findings of the literature review show that the integration of digital technology with the traditional impression method,along with computer fitting,can accurately obtain the patient's oral model and facilitate successful follow-up repairs.However,when the anterior mandibular dentition of the patient is absent,the margin of error is increased in this procedure,which deserves further exploration.Conclusion Utilizing digital technology as the leading method,combined with the tradi-tional impression method of segmental impression,for the repair of dental defects in patients with limited mouth open-ing,has proven to be effective.Thus,patients report a positive medical experience with high satisfaction,indicating that this approach is worthy of clinical promotion.
8.Application of socket-shield technique for immediate implant placement and provisionalization in esthetic zone:a case report and literature review
Xiting ZHU ; Hao WANG ; Zhuoli ZHU ; Min ZHOU ; Chen LI ; Xueqi GAN
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(1):57-63
Objective To investigate the effect of the socket-shield technique(SST)concurrent with immediate im-plant placement and provisionalization(IIPP)in the aesthetic restoration of anterior teeth.Methods A case of maxil-lary anterior tooth stumps with a thin labial bone wall was treated with SST for preservation of labial soft and hard tissue fullness,combined with an immediate implant placement and immediate provisional crown for restoring the shape of the tooth and gingival molding.Results Immediate implant placement and provisionalization restored the morphology and function of the affected tooth in the shortest possible time.The patient's labial soft and hard tissue contours in the affected tooth area were well preserved in the 18-month follow-up after the application of the SST,which presented a better aesthetic result.The literature review indicates that the indications for SST are unrestorable maxillary anterior teeth,whose dental,periodontal and periapical tissues are healthy and intact.In the esthetic zone,root shielding is effec-tive in maintaining the soft and hard tissue contour on the labial side of the implant.However,there is no consensus on the technical details of SST,such as the ideal coronal height and thickness of the shield,and the management of the gap between the shield and the implant.Thus,more clinical studies and histologic evidence are needed to provide a refer-ence for clinical decision-making.In addition,digital technology can improve the accuracy of implant placement and shield preparation.Conclusion The correct application of SST combined with IIPP in the esthetic zone can ensure es-thetic results.However,more high-quality evidence-based medical evidence is needed for its long-term efficacy,and in-dications should be strictly controlled during clinical application.
9.Clinical characteristics and prognostic analysis of neonatal chylothorax
Yan CHEN ; Xueqi LI ; Zixin YANG ; Xiying XIANG ; Yujie QI ; Mingyan HEI
Chinese Journal of Neonatology 2024;39(4):209-212
Objective:To investigate the clinical characteristics and prognosis of neonatal chylothorax.Methods:The clinical data of newborns diagnosed with chylothorax from June 2016 to June 2023 in Neonatal Center of Beijing Children's Hospital were retrospectively analyzed, and divided into congenital group and acquired group according to the pathogenesis of chylothorax. The clinical characteristics, treatment methods and prognosis of the two groups were compared.Results:A total of 23 cases were included, including 17 cases (73.9%) in the congenital group and 6 cases (26.1%) in the acquired group. There was no significant difference in gender, gestational age and birth weight between the two groups ( P>0.05). Compared with the acquired group, the proportion of lymphocytes (97.0% vs. 85.0%), the use of erythromycin (7/17 vs. 1/6) and octreotide (9/17 vs. 1/6) and special formula milk feeding (13/17 vs. 2/6) were higher in the congenital group; the proportion of right hydrothorax (1/17 vs. 3/6), invasive mechanical ventilation (6/17 vs. 6/6) and breastfeeding (0/17 vs. 3/6) were lower in the congenital group ( P<0.05). There were no significant differences in terms of the white blood cell count in pleural fluid and plasma protein content, incidence of bilateral and left pleural fluid, proportion of closed thoracic drainage, maximum daily drainage volume, drainage duration, total drainage volume, albumin utilization rate, length of stay and survival rate between the two groups ( P>0.05). 18 cases of pleural effusion absorption without recurrence after conservative treatment; 5 cases died, of which 4 cases died after their parents abandoned treatment, and 1 case died of neonatal necrotizing enterocolitis after thoracic duct ligation surgery. Conclusions:Congenital chylothorax and acquired chylothorax were similar in severity, course of disease and overall prognosis. The utilization rate of erythromycin and octreotide in congenital chylothorax was higher than that in acquired chylothorax. The neonatal chylothorax is usually with an overall good prognosis.
10.Digital repair for a patient with limited mouth opening:a case report and literature review
Zhenghao YANG ; Xiting ZHU ; Chen LI ; Min ZHOU ; Xueqi GAN
Journal of Prevention and Treatment for Stomatological Diseases 2024;(3):216-222
Objective To explore an accurate method to obtain an intraoral model of patients with specific limited mouth opening(microstomia)due to systemic scleroderma.Methods This study followed medical ethics,and informed consent has been obtained from patients.A case of Ken's Type Ⅰ mandibular dentition defect scleroderma with limited mouth opening was addressed with digital technology as the leading method combined with the traditional impression method of segmental impression.Individual trays were made based on the patient's left and right mandibular dentition,and segmented molds were obtained.Simultaneously,intraoral scanning was performed to obtain the morphological data of both the soft and hard tissues of the upper and lower mandibles.After each part of the model was obtained,the man-dibular model was scanned and digitally aligned to form the final denture model,and the final removable partial denture was designed and made by computer aided design/computer aided manufacturing(CAD/CAM)technology.At the same time,combined with the literature,the diagnosis and treatment of removable partial denture in patients with limited mouth opening were retrospectively analyzed.Results The denture was well retained and achieved a good repair ef-fect.The patients expressed satisfaction with the mastication efficiency and other functions of the denture.The findings of the literature review show that the integration of digital technology with the traditional impression method,along with computer fitting,can accurately obtain the patient's oral model and facilitate successful follow-up repairs.However,when the anterior mandibular dentition of the patient is absent,the margin of error is increased in this procedure,which deserves further exploration.Conclusion Utilizing digital technology as the leading method,combined with the tradi-tional impression method of segmental impression,for the repair of dental defects in patients with limited mouth open-ing,has proven to be effective.Thus,patients report a positive medical experience with high satisfaction,indicating that this approach is worthy of clinical promotion.


Result Analysis
Print
Save
E-mail