1.The management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection
Xuelian DENG ; Liang ZANG ; Xiaofang GONG ; Lei ZHOU ; Xiaochun LIU ; Lin WANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):444-451
Objective: To explore the management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection. Methods: Multiple HCV antibody assays, repeating HCV RNA testing, follow-up of blood donors and retesting of archive samples were performed to confirm HCV infection, identify infection status, and exclude false positives in blood donors reactive to HCV in blood screening. Results: From 2011 to 2024, the unqualified rate of HCV detection in blood screening was 2.45‰(2 751/1 122 026). Among these, anti-HCV+-&NAT-accounted for 1.85‰, followed by anti-HCV++ at 0.60‰. The proportion of anti-HCV+-&NAT-and HCV RNA yields was extremely low (0.007‰). The positive rate of anti-HCV+-&NAT-samples tested by electrochemiluminescence method (ELCIA) was approximately 7.5%, differing among reagents (P<0.05). The follow-up of anti-HCV+-&NAT-donors showed that 96.2% (202/210) were false positives, but 51.4% of donors remained anti-HCV+-&NAT-during follow-up. Among them, 8 donors (3.8%) could not be ruled out from HCV infection due to positive retesting by ELCIA. Of the anti-HCV+-&NAT-donors who were reactive at the first follow-up, 86.8% remained anti-HCV+-&NAT-at the second follow-up. The sampling confirmation data showed that all of 260 anti-HCV++ donors were confirmed as anti-HCV positive, and the proportion of false positives or missed detections by NAT was very low. Two occult HBV infections (OBIs) and one HBsAg carrier were identified among the 3 anti-HCV +-&NAT+ donors, and no HCV infection was confirmed in 5 anti-HCV--&HCV RNA + donors. Conclusion: The prevalence of HCV among blood donors in Dalian was about 0.06%, with extremely low proportion of window-period infection and slightly higher proportion of resolved infections than that of current infections. The majority of anti-HCV+-&NAT-were false positive. Blood donors confirmed as false positive should be qualified in blood screening 3 months later before next donation. In order to reduce the false positive results, it was advisable to avoid the same type of supplementary reagents as the initial reagents when performing confirmation.
2.Palpitations, Shortness of Breath, Weakness in Limbs, Edema, and Dyspnea: A Rare Inflammatory Myopathy with Positive Aniti-mitochondrial Antibodies and Cardiac Involvement
Chunsu LIANG ; Xuchang ZHANG ; Ning ZHANG ; Lin KANG ; Xiaohong LIU ; Jiaqi YU ; Yingxian LIU ; Lin QIAO ; Yanli YANG ; Xiaoyi ZHAO ; Ruijie ZHAO ; Na NIU ; Xuelian YAN
Medical Journal of Peking Union Medical College Hospital 2025;16(1):248-255
This article presents a case study of a patient who visited the Geriatric Department of Peking Union Medical College Hospital due to "palpitations, shortness of breath for more than 2 years, limb weakness for 6 months, edema, and nocturnal dyspnea for 2 months". The patient exhibited decreased muscle strength in the limbs and involvement of swallowing and respiratory muscles, alongside complications of heart failure and various arrhythmias which were predominantly atrial. Laboratory tests revealed the presence of multiple autoantibodies and notably anti-mitochondrial antibodies. Following a comprehensive multidisciplinary evaluation, the patient was diagnosed with anti-mitochondrial antibody-associated inflammatory myopathy. Treatment involved a combination of glucocorticoids and immunosuppressants, along with resistance exercises for muscle strength and rehabilitation training for lung function, resulting in significant improvement of clinical symptoms. The case underscores the importance of collaborative multidisciplinary approaches in diagnosing and treating rare diseases in elderly patients, where careful consideration of clinical manifestations and subtle abnormal clinical data can lead to effective interventions.
3.A Case Report of Hypothyrotropin Hypothyroidism Caused by Roxadustat
Xuelian YAN ; Bingying TANG ; Xuan QU ; Ning ZHANG ; Lin KANG
Medical Journal of Peking Union Medical College Hospital 2025;16(2):519-522
Roxadustat is the world's first small molecule hypoxia-inducible factor prolyl hydroxylase inhibitor. Its adverse effect of causing hypothyroidism with low thyroid-stimulating hormone (TSH) is relatively rare and manifests subtly in elderly patients with multiple coexisting diseases. This article reports a case of an elderly patient with renal anemia who developed reversible low-TSH hypothyroidism after taking roxadustat for 12 days, with a significant decrease in thyroid hormone levels. After discontinuing roxadustat for 15 days, the thyroid hormone levels gradually returned to normal. Due to the worsening of renal anemia, the patient took roxadustat again, and 9 days later, the thyroid function-related indicators decreased upon re-examination, leading to the initiation of levothyroxine replacement therapy. In conjunction with relevant literature, this article analyzes the adverse reactions that occur during the oral administration of roxadustat in elderly patients with chronic kidney disease, aiming to provide reference for drug treatment of such patients.
4.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
5.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
6.Research progress in the treatment of minor stroke
Lingming KONG ; Xuelian DENG ; Lin YIN
Chinese Journal of General Practitioners 2025;24(7):868-871
Minor stroke has a high incidence, accounting for up to 50% of acute ischemic stroke (AIS). The symptoms are typically mild at the initial onset, with significant concealment, and thus are easily overlooked by patients, leading to delayed medical intervention. However, minor stroke is associated with a high recurrence rate and susceptibility to early neurological deterioration (END), which may rapidly worsen the condition. This often results in missing the optimal treatment window and unfavorable prognoses. Currently, controversies persist regarding standardized treatment strategies for minor stroke, as inappropriate interventions could increase the risk of disability and mortality. This article reviews recent research advances in treatment plans for patients with a National Institutes of Health Stroke Scale (NIHSS) score ≤5, aiming to summarize the latest evidence and provide references for clinical practice.
7.Clinical application value of contrast-enhanced ultrasound in the differential diagnosis of testicular masses
Hui CHEN ; Ruoli LIU ; Xuelian ZHU ; Xuanchen JIN ; Wenya LIN ; Zuoliu XIE
China Modern Doctor 2025;63(14):15-17,30
Objective To explore the clinical application value of contrast-enhanced ultrasound in the differential diagnosis of testicular masses.Methods A total of 63 patients at the First Affiliated Hospital of Wenzhou Medical University with testicular masses from January 2014 to August 2024 were sellected.All patients underwent both conventional ultrasound and contrast-enhanced ultrasound examinations.Among them,pathological results were obtained through surgical resection in 55 cases,and 8 non-tumorous patients were diagnosed through clinical follow-up.According to the results,testicular masses were classified into neoplastic and non-neoplastic lesions.Neoplastic lesions were further divided into benign and malignant masses.The routine ultrasound parameters,serum tumor markers and ultrasound contrast parameters were analyzed.Results In the differential diagnosis between neoplastic and non-neoplastic lesions of the testis,there were significant statistical differences in the maximum diameter of the mass,blood flow grade,enhancement time,and enhancement intensity(P<0.05).In the differential diagnosis between benign and malignant testicular masses,significant statistical differences were found in mass location,maximum diameter of the mass,echo characteristics,blood flow grade indicators,enhancement time,and enhancement intensity(P<0.05).Conclusion Contrast-enhanced ultrasound may have certain reference value in the diagnosis of testicular masses.Hypo-enhancement or non-enhancement,along with slow enhancement,may be manifestations of benign lesions.
8.Advances in the application of gene copy number alteration detection technology in lymphoma
Yu PENG ; Shuang CHEN ; Tingting JIANG ; Can LIN ; Longrong RAN ; Xuelian WU ; Lian LI ; Liangmei LI ; Xinyi TANG ; Yakun ZHANG ; Huiyu XIANG ; Junxi LIU ; Dan JI ; Zailin YANG
International Journal of Laboratory Medicine 2025;46(15):1860-1866
Lymphoma is a highly heterogeneous malignancy characterized by complex molecular regulatory mechanisms that result in significant differences in aggressiveness and prognosis across its subtypes.Gene copy number alteration(CNA)analysis,an emerging technology,has become a pivotal tool in the precision re-search and management of lymphoma.By detecting DNA deletions,amplifications,and chromosomal copy number changes,CNA analysis addresses the limitations of traditional cytogenetic techniques,enhances the ac-curacy of subtype classification,and aids in evaluating tumor heterogeneity and disease progression.This re-view provides a comprehensive summary of CNA detection methods and their applications in lymphoma,with a focus on recent advancements in the field.It offers a comparative analysis of CNA detection techniques and discusses their role in precision diagnosis,subtype classification,monitoring disease progression,predicting therapeutic resistance,and assessing prognosis.Additionally,the review explores the potential applications of CNA analysis in uncovering molecular regulatory mechanisms,optimizing therapeutic strategies,and impro-ving patient survival outcomes.
9.Clinical application value of contrast-enhanced ultrasound in the differential diagnosis of testicular masses
Hui CHEN ; Ruoli LIU ; Xuelian ZHU ; Xuanchen JIN ; Wenya LIN ; Zuoliu XIE
China Modern Doctor 2025;63(14):15-17,30
Objective To explore the clinical application value of contrast-enhanced ultrasound in the differential diagnosis of testicular masses.Methods A total of 63 patients at the First Affiliated Hospital of Wenzhou Medical University with testicular masses from January 2014 to August 2024 were sellected.All patients underwent both conventional ultrasound and contrast-enhanced ultrasound examinations.Among them,pathological results were obtained through surgical resection in 55 cases,and 8 non-tumorous patients were diagnosed through clinical follow-up.According to the results,testicular masses were classified into neoplastic and non-neoplastic lesions.Neoplastic lesions were further divided into benign and malignant masses.The routine ultrasound parameters,serum tumor markers and ultrasound contrast parameters were analyzed.Results In the differential diagnosis between neoplastic and non-neoplastic lesions of the testis,there were significant statistical differences in the maximum diameter of the mass,blood flow grade,enhancement time,and enhancement intensity(P<0.05).In the differential diagnosis between benign and malignant testicular masses,significant statistical differences were found in mass location,maximum diameter of the mass,echo characteristics,blood flow grade indicators,enhancement time,and enhancement intensity(P<0.05).Conclusion Contrast-enhanced ultrasound may have certain reference value in the diagnosis of testicular masses.Hypo-enhancement or non-enhancement,along with slow enhancement,may be manifestations of benign lesions.
10.Research progress in the treatment of minor stroke
Lingming KONG ; Xuelian DENG ; Lin YIN
Chinese Journal of General Practitioners 2025;24(7):868-871
Minor stroke has a high incidence, accounting for up to 50% of acute ischemic stroke (AIS). The symptoms are typically mild at the initial onset, with significant concealment, and thus are easily overlooked by patients, leading to delayed medical intervention. However, minor stroke is associated with a high recurrence rate and susceptibility to early neurological deterioration (END), which may rapidly worsen the condition. This often results in missing the optimal treatment window and unfavorable prognoses. Currently, controversies persist regarding standardized treatment strategies for minor stroke, as inappropriate interventions could increase the risk of disability and mortality. This article reviews recent research advances in treatment plans for patients with a National Institutes of Health Stroke Scale (NIHSS) score ≤5, aiming to summarize the latest evidence and provide references for clinical practice.

Result Analysis
Print
Save
E-mail