1.Analysis on the results of national external quality assessment for transfusion compatibility test in 2023
Junhua HU ; Peng ZHANG ; Yanming LIU ; Shengchen TIAN ; Wanru MA ; Xiang LI ; Xuebin ZHAO ; Feng XUE ; Yuntian WANG ; Dong LIN ; Zheng SUN ; Lin ZHOU ; Jiwu GONG
Chinese Journal of Laboratory Medicine 2025;48(2):223-229
Objective:To analyze the results of national external quality assessment (EQA) for transfusion compatibility test in 2023, and provide reference for quality management of clinical transfusion compatibility testing.Methods:The EQA of clinical transfusion compatibility testing by NCCL was performed 3 times in 2023 among included laboratories. The panel consisting of 22 samples was distributed to 4 186 laboratories across 31 provinces (Including 2 961 tertiary hospital laboratories, 1 085 secondary hospital laboratories, 23 primary hospital laboratories, 106 blood station laboratories and 11 independent clinical laboratories). Each panel contains 11 red blood cell and 11 plasma samples per 1.5 ml/tube. Each participant laboratory of the EQA program was required to carry out the detection and return results in expected time. Statistical analysis and evaluation on the reported results were conducted by NCCL from the aspects of regional distribution, laboratory grading, testing methodology, reagent and testing system usage.Results:The qualification rates of EQA for five items including ABO positive typing, ABO reverse typing, RhD blood type, antibody screening, and cross matching were 96.68%, 95.10%, 96.46%, 95.32%, and 91.04%, respectively. The EQA qualification rate of tertiary hospital laboratories was 87.77% (2 599/2 961), which was significantly higher than the 77.79% (844/1 085) of secondary hospital laboratories. There were significant differences in the qualification rate of participating laboratories among different regions. The utilization rates of micro column agglutination method in ABO positive typing, ABO reverse typing, RhD blood type, antibody screening, and cross matching were 80.81% (10 080/12 474), 75.06% (9 337/12 440), 81.38% (10 118/12 433), 89.59% (11 104/12 394) and 76.25% (9 495/12 453), respectively. The qualification rate of micro column agglutination method was significantly higher than that of saline slide method in ABO positive typing detection ( P<0.05). The qualification rate of micro column agglutination method was significantly higher than that of the polyamine method and anti-human globulin test tube method in antibody screening ( P<0.05). There were statistically significant differences in qualification rate of 7 reagents in ABO reverse typing, antibody screening and cross matching ( P<0.05). There was no statistically significant difference in the qualification rate between the two detection systems for other reagents, except for the ABO reverse typing where the qualification rate of reagent 1 in a single system was higher than that in a mixed system ( P<0.05). Conclusion:The testing capabilities of clinical laboratories in different regions and different type varied significantly in China. Micro column agglutination method was the most popular selection in transfusion compatibility testing. The regents used in these laboratories showed good performance. However, the detection efficiency of some reagents still need to be improved. EQA could be used to evaluate, monitor, and improve the quality of testing.
2.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
3.The impact of implantable cardioverter defibrillator with lead alert function on inappropriate shocks caused by lead malfunctions
Cuizhen YUAN ; Feng ZE ; Cuncao WU ; Jiangbo DUAN ; Xu ZHOU ; Dandan YANG ; Ding LI ; Xuebin LI
Chinese Journal of Cardiology 2025;53(12):1398-1403
Objective:To evaluate the incidence and frequency of inappropriate shocks caused by defibrillation lead failure in patients with implantable cardioverter-defibrillators (ICD), and to explore methods for reducing the incidence and frequency of such inappropriate shocks.Methods:This was a single-center retrospective study involving patients treated for defibrillation lead failures at Peking University People′s Hospital between March 2015 and May 2024. Patients were divided into an alarm function group and a non-alarm function group based on whether their ICDs were equipped with lead alarm functions. Clinical data, lead data, and the incidence and frequency of inappropriate shocks were collected and compared between the two groups. A multivariate logistic regression model was used to analyze factors influencing the incidence and frequency of inappropriate ICD shocks. Kaplan-Meier survival curves were plotted to compare the trends in the incidence and frequency of inappropriate shocks over time since ICD implantation between the two groups.Results:A total of 59 patients were enrolled, with a age of (56.7±15.2) years, including 42 males (71%). The lifespan of the failed leads in the entire cohort was 64.0 (36.0, 96.0) months. There were 26 patients in the alarm function group and 33 in the non-alarm function group. The most common manifestations of lead failure were oversensing (85%, 50/59) and abnormal pacing impedance (42%, 25/59). A total of 33 patients (56%, 33/59) experienced inappropriate shock therapy, with an average of 27.3 shocks per patient. The frequency of inappropriate ICD shocks in the non-alarm function group was higher than that in the alarm function group (25.0 (10.0, 60.0) times/year vs. 5.0 (2.8, 7.8) times/year, P=0.001). Multivariate logistic regression analysis showed that oversensing ( OR=2.057, 95% CI 1.125-6.763, P=0.019) was an influencing factor for incidence of inappropriate shocks, while the lead alert function ( OR=0.062, 95% CI 0.005-0.719, P=0.001) was a factor influencing the frequency of inappropriate shocks. Kaplan-Meier survival analysis revealed that the incidence and frequency of inappropriate shocks increased with the duration of ICD implantation in both groups, but the differences were not statistically significant (incidence: log-rank P=0.908; frequency: log-rank P=0.767). Conclusion:The lead alert function can reduce the frequency of inappropriate shocks caused by lead failure.
4.Management for Redundant Lead:Current Status and Future Perspectives
Chinese Circulation Journal 2025;40(4):397-401
With the increasing numbers of implanted cardiovascular implantable electronic devices(CIED),the issue of lead management has become increasingly prominent.Currently,there is controversy on the management of redundant lead.In clinical practices such as CIED device upgrades,choosing to abandon redundant leads can avoid the risks associated with lead extraction.However,the strategy may increase the risks of future CIED infections,venous occlusions,and the risks of future lead extraction.On the other hand,choosing to remove redundant leads might expose patients to risks associated with lead extraction.Therefore,the management regarding redundant lead need to balance the risks of abandonment and extraction strategies.This article discusses the current strategies for redundant lead management and their potential risks.
5.Research on Lightweight Large Language Models for Ancient Traditional Chinese Medicine Texts Based on Lora Fine-Tuning
Jingxian CHAI ; Xufeng LANG ; Hongyan LI ; Zuojian ZHOU ; Yun LING ; Libin ZHAN ; Kongfa HU ; Xuebin QIAO
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(3):823-831
Objective To address the challenges of constructing large language models for traditional Chinese medicine(TCM)classics,which are complex and expensive to fine-tune,this study explores a lightweight fine-tuning method for such models,aiming to develop a question-answering model centered on TCM classics,particularly various editions of Shang Han Lun through the ages.Methods Dataset construction involved designing prompts to guide GPT-4 in generating Q&A pairs based on Shang Han Lun and integrating them with the ShenNong_TCM_Dataset and cMedQA2 datasets.Five general-purpose large models were selected for Lora fine-tuning.The best model was chosen through evaluation,and the performance of multiple quantized versions was validated.Results After fine-tuning,the BLEU,ROUGE-1,ROUGE-2,and ROUGE-L metrics for the Qwen-7B-Chat model improved by 17.61,19.63,14.3,and 21.4,respectively,compared to the base model.Conclusion The selected model in this study is capable of effectively understanding and utilizing professional terms and concepts from TCM classics,such as Shang Han Lun,to provide accurate answers to user queries.Compared to similar models,it requires lower fine-tuning costs and computational power,contributing to the dissemination of TCM knowledge and the development of intelligent systems.
6.Feasibility study of subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction
Cuizhen YUAN ; Feng ZE ; Ding LI ; Cuncao WU ; Jinshan HE ; Yi WEI ; Jingliang ZHOU ; Xuebin LI
Chinese Journal of Cardiology 2025;53(10):1141-1145
Objective:To evaluate the clinical feasibility of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation following transvenous lead extraction (TLE).Methods:This was a retrospective study. Consecutive patients who underwent S-ICD implantation at Peking University People′s Hospital between June 2015 and October 2023 were enrolled. Patients were divided into the TLE group and the newly implanted group based on whether they received TLE prior to S-ICD implantation. Baseline characteristics, S-ICD indication, defibrillation threshold test results, complications, and postoperative follow-up data were collected and compared between the two groups.Results:A total of 27 patients were included, aged (49.2±14.2) years, including 19 males. There were 12 patients in the TLE group and 15 in the newly implanted group. Compared with the TLE group, patients in the newly implanted group were younger ((43.3±13.7) years vs. (55.6±12.0) years, P=0.013). The main S-ICD indication in the TLE group was high infection risk (9/12), whereas in the newly implanted group it was younger age (11/15). All patients underwent successful S-ICD implantation, with 18 patients completing defibrillation threshold testing (all successful). Additionally, the TLE group had longer follow-up duration than the newly implanted group (42 (19, 60) months vs. 12 (3, 28) months, P=0.001). No complications or deaths occurred during follow-up, with normal device function in both groups. A total of 17 ventricular tachycardia or fibrillation events were recorded, of which 7 met defibrillation criteria and all received effective therapy. Conclusion:S-ICD demonstrates safety and efficacy as a therapeutic option for patients after TLE, with comparable device functionality and follow-up outcomes to patients with newly implanted S-ICD.
7.The impact of implantable cardioverter defibrillator with lead alert function on inappropriate shocks caused by lead malfunctions
Cuizhen YUAN ; Feng ZE ; Cuncao WU ; Jiangbo DUAN ; Xu ZHOU ; Dandan YANG ; Ding LI ; Xuebin LI
Chinese Journal of Cardiology 2025;53(12):1398-1403
Objective:To evaluate the incidence and frequency of inappropriate shocks caused by defibrillation lead failure in patients with implantable cardioverter-defibrillators (ICD), and to explore methods for reducing the incidence and frequency of such inappropriate shocks.Methods:This was a single-center retrospective study involving patients treated for defibrillation lead failures at Peking University People′s Hospital between March 2015 and May 2024. Patients were divided into an alarm function group and a non-alarm function group based on whether their ICDs were equipped with lead alarm functions. Clinical data, lead data, and the incidence and frequency of inappropriate shocks were collected and compared between the two groups. A multivariate logistic regression model was used to analyze factors influencing the incidence and frequency of inappropriate ICD shocks. Kaplan-Meier survival curves were plotted to compare the trends in the incidence and frequency of inappropriate shocks over time since ICD implantation between the two groups.Results:A total of 59 patients were enrolled, with a age of (56.7±15.2) years, including 42 males (71%). The lifespan of the failed leads in the entire cohort was 64.0 (36.0, 96.0) months. There were 26 patients in the alarm function group and 33 in the non-alarm function group. The most common manifestations of lead failure were oversensing (85%, 50/59) and abnormal pacing impedance (42%, 25/59). A total of 33 patients (56%, 33/59) experienced inappropriate shock therapy, with an average of 27.3 shocks per patient. The frequency of inappropriate ICD shocks in the non-alarm function group was higher than that in the alarm function group (25.0 (10.0, 60.0) times/year vs. 5.0 (2.8, 7.8) times/year, P=0.001). Multivariate logistic regression analysis showed that oversensing ( OR=2.057, 95% CI 1.125-6.763, P=0.019) was an influencing factor for incidence of inappropriate shocks, while the lead alert function ( OR=0.062, 95% CI 0.005-0.719, P=0.001) was a factor influencing the frequency of inappropriate shocks. Kaplan-Meier survival analysis revealed that the incidence and frequency of inappropriate shocks increased with the duration of ICD implantation in both groups, but the differences were not statistically significant (incidence: log-rank P=0.908; frequency: log-rank P=0.767). Conclusion:The lead alert function can reduce the frequency of inappropriate shocks caused by lead failure.
8.Clinical-epidemiological characteristics of connective tissue diseases complicated with pulmonary hypertension in Shanxi province, 2018-2021
Lizhi WANG ; Xuebin HAN ; Li LI ; Zhixin WANG ; Yanqing GUO
Chinese Journal of General Practitioners 2025;24(2):156-161
Objective:To investigate the clinical-epidemiological characteristics of connective tissue diseases (CTD) complicated with pulmonary hypertension in Shanxi province from 2018 to 2021.Methods:This was a cross-sectional study. Data of CTD patients with pulmonary hypertension from 2018 to 2021 were collected from the Shanxi Provincial Health Statistics Direct Reporting System based on inpatient medical records. The demographic and clinical data of patients with different CTD types were analyzed.Results:A total of 1 697 CTD patients with pulmonary hypertension were included, among whom there were 451 cases (26.58%) of Sj?gren′s syndrome, 392 cases (23.10%) of systemic lupus erythematosus, 289 cases(17.03%) of systemic sclerosis, 109 cases (6.42%) of mixed CTD, 69 cases (4.07%) of Takayasu arteritis, and 387 cases (22.80%) of other CTD. The majority of patients were female (1 410 (83.09%)), and 783 cases (46.14%) were aged between 41 and 65 years, and 6 cases (0.35%) were performed right heart catheterization. The prevalence of CTD with pulmonary hypertension increased from 0.06/10 4 in 2018 to 0.20/10 4 in 2021. There were significant differences in the severity of pulmonary hypertension, New York Heart Association (NYHA) functional class, length of hospital stay, medical costs, and clinical outcomes among patients with different CTD subtypes (all P<0.001). Patients with systemic sclerosis had the highest proportion of NYHA functional class Ⅲ/Ⅳ(65.1%(188/289)), the longest length of hospital stays (13 (9, 18) days), the highest average medical costs (13 622.67 (8 636.38, 20 597.75) ¥(RMB)), and the lowest rate of improvement and discharge (51.90%(150/289)). Conclusions:Between 2018 and 2021, Shanxi province, where CTD is more common in Sj?gren′s syndrome, has a high proportion of women, a high proportion of people aged 41-65 years, and a low prevalence of right ventricular catheterization in patients with CTD complicated with pulmonary hypertension. The prevalence of CTD complicated with pulmonary hypertension shows a rising trend in Shanxi province from 2018 to 2021, while patients with systemic sclerosis exhibit the most severe cardiac impairment and poorer clinical outcomes compared to other subtypes.
9.Analysis on the results of national external quality assessment for transfusion compatibility test in 2023
Junhua HU ; Peng ZHANG ; Yanming LIU ; Shengchen TIAN ; Wanru MA ; Xiang LI ; Xuebin ZHAO ; Feng XUE ; Yuntian WANG ; Dong LIN ; Zheng SUN ; Lin ZHOU ; Jiwu GONG
Chinese Journal of Laboratory Medicine 2025;48(2):223-229
Objective:To analyze the results of national external quality assessment (EQA) for transfusion compatibility test in 2023, and provide reference for quality management of clinical transfusion compatibility testing.Methods:The EQA of clinical transfusion compatibility testing by NCCL was performed 3 times in 2023 among included laboratories. The panel consisting of 22 samples was distributed to 4 186 laboratories across 31 provinces (Including 2 961 tertiary hospital laboratories, 1 085 secondary hospital laboratories, 23 primary hospital laboratories, 106 blood station laboratories and 11 independent clinical laboratories). Each panel contains 11 red blood cell and 11 plasma samples per 1.5 ml/tube. Each participant laboratory of the EQA program was required to carry out the detection and return results in expected time. Statistical analysis and evaluation on the reported results were conducted by NCCL from the aspects of regional distribution, laboratory grading, testing methodology, reagent and testing system usage.Results:The qualification rates of EQA for five items including ABO positive typing, ABO reverse typing, RhD blood type, antibody screening, and cross matching were 96.68%, 95.10%, 96.46%, 95.32%, and 91.04%, respectively. The EQA qualification rate of tertiary hospital laboratories was 87.77% (2 599/2 961), which was significantly higher than the 77.79% (844/1 085) of secondary hospital laboratories. There were significant differences in the qualification rate of participating laboratories among different regions. The utilization rates of micro column agglutination method in ABO positive typing, ABO reverse typing, RhD blood type, antibody screening, and cross matching were 80.81% (10 080/12 474), 75.06% (9 337/12 440), 81.38% (10 118/12 433), 89.59% (11 104/12 394) and 76.25% (9 495/12 453), respectively. The qualification rate of micro column agglutination method was significantly higher than that of saline slide method in ABO positive typing detection ( P<0.05). The qualification rate of micro column agglutination method was significantly higher than that of the polyamine method and anti-human globulin test tube method in antibody screening ( P<0.05). There were statistically significant differences in qualification rate of 7 reagents in ABO reverse typing, antibody screening and cross matching ( P<0.05). There was no statistically significant difference in the qualification rate between the two detection systems for other reagents, except for the ABO reverse typing where the qualification rate of reagent 1 in a single system was higher than that in a mixed system ( P<0.05). Conclusion:The testing capabilities of clinical laboratories in different regions and different type varied significantly in China. Micro column agglutination method was the most popular selection in transfusion compatibility testing. The regents used in these laboratories showed good performance. However, the detection efficiency of some reagents still need to be improved. EQA could be used to evaluate, monitor, and improve the quality of testing.
10.Meropenem-loaded microbubbles combined with ultrasound-targeted disruption of Escherichia coli biofilms
Youcai MA ; Wenbo MU ; Liqin YAO ; Qiongdan XING ; Li CAO ; Xuebin SUN
Chinese Journal of Ultrasonography 2025;34(3):247-255
Objective:To investigate the therapeutic efficacy and disruptive effects of Meropenem(MEM)-loaded microbubbles(MBs)combined with ultrasound targeted microbubble destruction(UTMD)technology on Escherichia coli and its biofilm.Methods:MEM-MBs were prepared using the thin-film hydration method,and their characterization was assessed using a Zeta potential analyzer,with morphological observations conducted under an optical microscope. An in vitro biofilm model of periprosthetic joint infection(PJI)caused by Escherichia coli was constructed,and the morphology of the biofilm and the distribution of MEM-MBs in the bacterial biofilm were observed under a laser confocal microscope after staining the biofilm with SYTO59 staining and DIL staining for Microbubbles. The biofilm morphology and the distribution of MEM-MBs in bacterial biofilm were observed under laser confocal microscope. The biofilms were randomly divided into 5 groups using a random number table:control,Meropenem(MEM),MEM-MBs,UTMD,and MEM-MBs+UTMD,with 12 samples per group. After applying the respective interventions,scanning electron microscopy(SEM)and laser scanning confocal microscopy(LSCM)were employed to observe the effects on the morphology and structure of Escherichia coli and its biofilm. Crystal violet staining was utilized to determine and compare the biofilm density among groups using a microplate reader. LSCM was also used to observe the biofilm thickness,while both LSCM and spread plate counting were employed to assess bacterial viability differences across groups.Results:①MEM-MBs meeting the experimental requirements were successfully constructed.②A dense Escherichia coli biofilm visible under both the naked eye and LSCM was established,with a thickness of(10.61 ± 0.17)μm and a proportion of dead bacteria within the biofilm of(16.8 ± 0.8)%.③MEM-MBs were observed to penetrate into all layers of the biofilm using LSCM.④The results of crystal violet staining showed a decreasing trend in the biofilm density of the control group,the MEM group,the MEM-MBs group,the UTMD group,and the MEM-MBs+UTMD group. There was no significant difference between the MEM group and the MEM-MBs group( P>0.05),while there was a significant difference in biofilm density between the other groups,as revealed by pairwise comparison(all P<0.05).⑤UTMD technique and MEM-MBs+UTMD could significantly disrupt the biofilm of Escherichia coli. LSCM results showed that,compared to the control group,the thickness of the biofilm was reduced in all other groups,with only the UTMD group and the MEM-MBs+UTMD group showing an increase in porosity(both P<0.05). In comparison with the MEM group and the MEM-MBs group,the UTMD group showed an increase in porosity,while the MEM-MBs+UTMD group had a decrease in biofilm thickness and an increase in porosity(both P<0.05). Additionally,compared to the UTMD group,the MEM-MBs+UTMD group had a decrease in biofilm thickness and an increase in porosity(both P<0.05),based on laser confocal microscopy results.⑥The results of the plate counting and LSCM showed that,compared with the control group,clump counts decreased,and the proportion of dead cells increased in the MEM group,the MEM-MBs group,and the MEM-MBs+UTMD group(all P<0.05). Compared with MEM group and MEM-MBs group,the clump counts of UTMD group increased,the proportion of dead cells decreased(all P<0.05);the clump counts of MEM-MBs+UTMD group decreased,and the proportion of dead cells increased(all P<0.05).Compared with UTMD group(all P<0.05),the clump counts of MEM-MBs+UTMD group decreased,while the proportion of dead cells increased(all P<0.05).⑦The results of scanning electron microscopy revealed that the network structure of Escherichia coli was completely destroyed in the MEM-MBs+UTMD group. Conclusions:UTMD technology combined with MEM-MBs exerts a significant disruptive effect on the morphology and structure of Escherichia coli biofilm and significantly enhances bactericidal efficacy.

Result Analysis
Print
Save
E-mail