1.Analysis of the current situation and influencing factors of platelet supply in medical institutions
Xuan WU ; Ting ZHANG ; Xiaozhen GUAN ; Yang YU
Chinese Journal of Blood Transfusion 2026;39(3):339-345
Objective: To systematically analyze the current status and influencing factors of platelet supply in medical institutions across China, and to explore the problems and future development directions of the existing supply models. Methods: From February 25 to March 5, 2025, a web-based questionnaire survey was performed. A self-designed questionnaire was distributed to staff in the blood transfusion departments of medical institutions nationwide in China. Data on the current status and influencing factors of platelet supply were collected and analyzed. Results: A total of 2 268 responses were collected in this survey, with 1 366 valid questionnaires finally included, covering 33 provinces, autonomous regions, and municipalities directly under the central government across China. The survey revealed that platelet supply in Chinese medical institutions exhibited a pattern of "sufficient in the eastern region, stable in the central region, and scarce in the western region": adequate in East China; generally favorable in South China except Guangxi; centered on Beijing and Tianjin in North China; basically met but with insufficient reserves in Central China; subject to seasonal fluctuations in Northeast China; only meeting the baseline supply in Yunnan, Guizhou, and Sichuan in Southwest China; and notably short in Qinghai, Ningxia, and Xinjiang in Northwest China. Family donor mobilization was required in 81.2% (1 109/1 366) of institutions, whereas this proportion was only 12.7% (173/1 366) among institutions with sufficient supply. Tertiary hospitals constituted the main users, among which tertiary Class A hospitals had the highest sufficiency rate, and secondary Class B hospitals showed the most pronounced shortage. A total of 84% (1 147/1 366) of institutions lacked a professional management team; only 19% (266/1 366) had an inventory warning system, of which 88% (234/266) considered it effective. Platelet reservation required 3 days in 33% (458/1 366) of institutions. The mandatory transfusion rate was 30.55% (29/118) when the reservation lead time exceeded 3 days, representing an increase of 5.98% compared with 24.57% (55/180) in the same-day reservation group. For optimization, most institutions called for improved blood donation services, strengthened education and incentives, establishment of regional coordination and policy collaboration, and supplementary suggestions focused on technologies for extending platelet shelf life. Conclusion: Regional imbalance in platelet supply across China is prominent, with supply shortages in some provinces, reliance on family donor mobilization in most institutions, weak grassroots support capacity, imperfect management systems, and supply timeliness constraining clinical practice. Systematic improvements are needed in optimizing blood donation services, strengthening regional coordination, improving relevant policies, and developing platelet preservation technologies, so as to enhance the level of supply security and patient safety.
2.A prediction model for mild cognitive impairment risk among the elderly
MA Zongkang ; LIU Xinglang ; LI Huihui ; HE Guowei ; YAN Ping ; ZHANG Chuanrong ; MA Xuan ; CHE Yajie ; YU Shan ; CHEN Fenghui
Journal of Preventive Medicine 2026;38(2):124-129
Objective:
To develop a prediction model for mild cognitive impairment (MCI) risk among the elderly, so as to provide a tool for MCI early screening.
Methods :
From July 2022 to September 2024, a multi-stage stratified random cluster sampling method was used to recruit permanent residents aged ≥65 years from the Xinjiang Uygur Autonomous Region as study participants. Data on sociodemographic characteristics, nutritional status, body composition indices, bone mineral density, and handgrip strength were collected through questionnaires and physical examinations. Sarcopenia was defined based on appendicular skeletal muscle index and handgrip strength. MCI was assessed using the Mini-Mental State Examination, with adjustments for educational level. Participants were randomly divided into a training set and a validation set in a 7∶3 ratio. LASSO regression and multivariable logistic regression models were employed to screen for predictors and construct an MCI risk prediction model. The predictive performance of the model was evaluated using receiver operating characteristic (ROC) curve and decision curve analysis (DCA).
Results:
A total of 1 641 participants were surveyed, including 755 males (46.01%) and 886 females (53.99%). The majority of participants were aged 65-<75 years, comprising 1 154 individuals (70.32%). MCI was detected in 517 participants, corresponding to a detection rate of 31.51%. Resultsfrom LASSO regression and multivariate logistic regression analysis showed that residence (rural, OR = 2.323, 95% CI: 1.682-3.210), age (75-<85 years, OR = 1.405, 95% CI: 1.019-1.937; ≥85 years, OR = 3.655, 95% CI: 1.696-7.875), educational level (primary school, OR = 0.341, 95% CI: 0.247-0.472; junior high school, OR = 0.255, 95% CI: 0.160-0.408; high school, OR = 0.286, 95% CI: 0.154-0.531; bachelor's degree or above, OR = 0.120, 95% CI: 0.041-0.351), history of alcohol consumption (yes, OR = 3.216, 95% CI: 2.164-4.779), risk of malnutrition (yes, OR = 1.464, 95% CI: 1.064-2.014), sarcopenia (yes, OR = 3.197, 95% CI: 2.332-4.385), and waist-to-hip ratio (abnormal, OR = 1.540, 95% CI: 1.159-2.048) were identified as predictive factors for MCI among the elderly. In the training set, the area under the ROC curve, sensitivity, and specificity were 0.788, 0.719, and 0.712, respectively. In the validation set, the corresponding values were 0.784, 0.913, and 0.542, respectively. DCA demonstrated that the model provided a higher clinical net benefit for predicting MCI risk when the risk threshold probability ranged from 0.124 to 0.764.
Conclusion
The prediction model developed in this study demonstrates good discriminative ability and clinical utility, indicating its substantial value for predicting the MCI risk among the elderly.
3.Skeleton Binding Protein 1 of Plasmodium berghei Influences Deformability and Cytoskeletal Ultrastructure of Infected Erythrocyte
Xin-Yue GUO ; Huan-Qi ZHAO ; Yan-Xuan ZHONG ; Ru-Meng JIANG ; Yao-Xian LI ; Lei-Ting PAN ; Qian WANG ; Xiao-Yu SHI
Progress in Biochemistry and Biophysics 2026;53(4):1015-1027
ObjectiveThe malaria parasites remodel the host erythrocyte structure by exporting parasite proteins that interact with the membrane skeleton proteins of red blood cells (RBCs), facilitating their intracellular survival and pathogenicity. Skeleton-binding protein 1 (SBP1) is a conserved exported protein across Plasmodium species. In Plasmodium falciparum, SBP1 has been reported to interact with erythrocyte membrane skeleton proteins 4.1R and spectrin, while its contribution to erythrocyte remodeling and parasite virulence in Plasmodium berghei (Pb) remains unclear. This study aims to determine whether PbSBP1 associates with the host cytoskeletal protein 4.1R and to investigate its role in the remodeling of host RBCs and the pathogenicity of Plasmodium berghei. MethodsIn Plasmodium berghei, the relationship between PbSBP1 and the erythrocyte cytoskeletal protein 4.1R was examined using co-immunoprecipitation. A Pbsbp1 gene knockout mutant of Plasmodium berghei (Pbsbp1∆) was generated based on the principle of double crossover homologous recombination. The deformability of erythrocytes infected with Pbsbp1∆ parasites was assessed using microfluidic methods. Microchannels with an array of cylindrical pillars were used to detect modifications in infected RBC deformability. The infected RBCs were squashed between the rows and recovered between the columns and the transit velocity (μm/s) of infected RBCs travelling through the microchannel was recorded. The component of the erythrocyte membrane skeleton junctional complex, tropomodulin (TMOD), was fluorescently labeled, and the cytoskeletal network of infected erythrocytes was imaged using super-resolution stochastic optical reconstruction microscopy (STORM) to analyze ultrastructural changes in the cytoskeleton of wild-type (WT) and Pbsbp1∆-infected erythrocytes. Actin-based junctional complexes were displayed as individual clusters by the labeled TMOD in the STORM images, and the cluster densities and distances between adjacent clusters of infected RBCs were calculated. Additionally, rodent malaria models (BALB/c mice) and experimental cerebral malaria models (C57BL/6 mice) were employed to monitor the growth of Pbsbp1∆ and WT parasites during the intraerythrocytic stage and their capacity to induce cerebral malaria in mice. ResultsPbSBP1 may participate in the remodeling of infected erythrocytes through direct or indirect interaction with the erythrocyte cytoskeletal protein 4.1R. Microfluidic assays revealed that the deformability of erythrocytes infected with Pbsbp1∆ parasites was significantly enhanced compared to those infected with WT parasites. STORM imaging further demonstrated that the ultrastructure of the erythrocyte cytoskeleton in Pbsbp1∆-infected cells was altered relative to that in WT-infected erythrocytes. The distances between nearest neighbors of clusters had a tendency to increase while the cluster densities were decreased in Pbsbp1∆-infected RBCs compared to WT-infected RBCs. Subsequent phenotypic analysis indicated that the growth rate of Pbsbp1∆ parasites during the intraerythrocytic stage was significantly slower than that of WT parasites, and their ability to induce cerebral malaria in mice was also attenuated. These findings suggest that PbSBP1 is involved in the remodeling of the erythrocyte membrane skeleton, likely through its direct or indirect interaction with protein 4.1R, thereby regulating the deformability of infected erythrocytes and influencing the pathogenicity of the blood-stage parasites. ConclusionThis study establishes a role for PbSBP1 in host erythrocyte remodeling and parasite virulence, providing new research strategies for the prevention and treatment of malaria.
4.Clinical Observation on Huatan Quyu Formula Improving Cerebral Small Vessel Disease with Phlegm and Blood Stasis Blocking Collateral Pattern via Regulating Glymphatic System Circulation
Xiaofeng HUANG ; Ting YU ; Xuan ZHANG ; Daichao MA ; Yongmei YAN ; Hui ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):205-211
ObjectiveTo observe the clinical efficacy and safety of Huatan Quyu formula in treating cerebral small vessel disease (CSVD) with phlegm and blood stasis blocking collateral pattern via randomized controlled trial, and explore its mechanism of improving CSVD by regulating glymphatic system (GS) circulation. MethodsSixty-eight CSVD patients with phlegm and blood stasis blocking collateral pattern in the Department of Encephalopathy, Affiliated Hospital of Shaanxi University of Chinese Medicine from April to December 2024 were selected and randomly divided into an experimental group (34 cases) and a control group, with 34 cases in each group. Both groups received basic Western medicine treatment, while the experimental group additionally received Huatan Quyu formula. After a course of 12 weeks, the following parameters were compared between the two groups before and after treatment. Clinical outcomes were assessed using the Tinetti performance-oriented mobility assessment (POMA), Montreal Cognitive Assessment (MoCA), Scales for Outcomes in Parkinson's Disease-Autonomic (SCOPA-AUT), and traditional Chinese medicine (TCM) syndrome scores of phlegm and blood stasis blocking collateral pattern. Perivascular space (PVS) in the frontal lobe/basal ganglia and cerebrospinal fluid (CSF) flow parameters in the cerebral aqueduct were evaluated by 3.0T brain MRI, cerebrospinal fluid flow imaging, and phase-contrast magnetic resonance imaging (PC-MRI). Then, safety indicators were monitored, and SPSS 25.0 was used for statistical analysis. ResultsSixty-four patients completed the study (32 in each group). ①Baseline data: No statistically significant difference was found between the two group. ②Efficacy indicators: After treatment, the experimental group exhibited significantly improved total POMA, SCOPA-AUT, and TCM syndrome scores (P<0.01), outperforming the control group (P<0.05). No significant change was observed in MoCA scores between the two groups. ③Imaging indicators: The experimental group showed a reduced PVS area alongside significantly increased CSF flow parameters (including downward flow during the systolic period, and upward flow during the diastolic period) (P<0.01), which were superior to the control group (P<0.01). ④Safety: The laboratory indicators were normal in both groups, with no drug-related adverse reactions. ConclusionFor CSVD patients with phlegm and blood stasis blocking collateral pattern, Huatan Quyu formula can safely and effectively improve motor function, autonomic nerve function, and TCM syndromes, with potential mechanisms related to pulsatile CSF flow enhancement and GS circulation efficiency improvement.
5.Value of dual-energy CT quantitative parameters combined with clinical features in diagnosis of stages T2 and T3 colorectal cancer
Ni FANG ; Xin WEI ; Weijuan CHEN ; Mei FENG ; Lingjing ZHANG ; Yuexi LIU ; Qi LAI ; Xuan DING ; Xinjie LIU ; Wei JIANG ; Han YU
Journal of Army Medical University 2025;47(2):177-185
Objective To investigate the diagnostic value of our regression model based on quantitative parameters of dual-energy CT and clinical features for stages T2 and T3 colorectal cancer.Methods A cross-section study was performed on 91 patients with colorectal cancer confirmed by postoperative pathology in our hospital from January 2022 to November 2023.All of them underwent dual-energy CT examination.According to the pathological T staging criteria of Chinese Colorectal Cancer Diagnosis and Treatment Standard(2020 Edition),they were divided into T2 group(n=43)and T3 group(n=48).Univariate analysis was used to compare the differences in quantitative CT parameters and clinical features between the 2 groups,and the obtained significant variables were employed to construct diagnosis models by univariate or multivariate logistic regression analysis.The area under receiver operating characteristic curve(AUC)of the CT parametric model and the model combined with clinical features was compared to evaluate the efficacy of diagnosing T2 and T3 stages.Results Univariate analysis showed that carcinoembryonic antigen(CEA),N stage,tumor location,tumor longest diameter(LD),CT value of virtual noncontrast(CT-VNC),fat fraction,electron density(Rho)and dual energy index(DEI)were significantly different between the T2 and T3 groups(P<0.05).Multivariate logistic regression analysis found that N stage,tumor location,LD,fat fraction and DEI were independent risk factors for the diagnosis of stage T3.The AUC value of the model of above CT parameters in diagnosing stage T3 colorectal cancer was 0.671(95%CI:0.558~0.783),and the AUC value of the combined model of above CT parameters and clinical features was 0.886(95%CI:0.815~0.957),and statistical difference was observed in the AUC value between the combined model and the CT parametric model(P<0.01).Conclusion The regression model constructed with dual-energy CT quantitative parameters combined with clinical features has high value in the preoperative diagnosis of stages T2 and T3 colorectal cancer before surgery.
6.Prediction of risk for acute kidney injury and its progression to mortality in obese patients admitted to ICU postoperatively
Qiang LI ; Guo MU ; Wenzhang WANG ; Jie YIN ; Xuan YU ; Bin LU ; Qian LI ; Jun ZHOU
Journal of Army Medical University 2025;47(10):1110-1125
Objective To develop a machine learning-based risk prediction model for postoperative acute kidney injury(AKI)and a model for mortality in obese patients admitted to intensive care unit(ICU)in order to improve early warning and prognostic evaluation to support clinical decision-making.Methods Data of obese postoperative ICU patients were retrospectively retrieved from the MIMIC-Ⅳ and eICU databases for statistical analysis.Ultimately,2 520 patients(670 from MIMIC-Ⅳ and 1 850 from eICU databases)were included to build the risk prediction models for AKI and mortality.The data included demographic information,vital signs,laboratory findings,surgical types,comorbidities,and medication use.After data cleaning and preprocessing,Boruta feature selection was applied,followed by the construction of prediction models using 7 machine learning algorithms,that is,Gradient Boosting Machine(GBM),Generalized Linear Model(GLM),k-Nearest Neighbors(KNN),Na?ve Bayes(NB),Neural Network(NNET),Support Vector Machine(SVM),and XGBoost.Model performance was evaluated through cross-validation and external validation.Results In the risk prediction models of AKI,the SVM model achieved the highest AUC value of 0.80 in the testing set and 0.71 in the external validation test.For the risk prediction models of mortality,the GBM model outperformed others in the prediction,attaining an AUC value of 0.91 in the testing set.Conclusion Risk predictive models for postoperative AKI and mortality in obese ICU patients are successfully constructed,and are valuable tools for clinicians to optimize early intervention and improve clinical outcomes for the patients.
7.Recent Advances of Carbon Dots in Chemiluminescence
Yu-Jie XIAO ; Xuan TAN ; Yue ZHAO ; Ke CHENG ; Xue ZHANG ; Xian YANG ; Hong ZHENG
Chinese Journal of Analytical Chemistry 2025;53(1):27-37
Chemiluminescence,as a self-luminous phenomenon that does not require light,heat,acoustic,electric and magnetic excitation,has been widely used in the fields of analytical chemistry,cold light source and bio-imaging because of its advantages including high sensitivity,wide linear range,simple equipment and fast detection speed compared with other analytical techniques.Carbon dots(CDs)are a class of nanomaterials with excellent photoluminescence properties and high biocompatibility.CDs are stable,easy to prepare and abundant in types,and researchers have introduced many types of CDs into different chemiluminescence systems.In this paper,the applications of CDs in common chemiluminescence systems and the possible mechanisms of action were discussed,and the research progresses on the application of CDs in different chemiluminescence detection fields in recent years were summarized.Finally,the development trend of CDs in chemiluminescence was analyzed.
8.Energy-resolved Mass Spectrometry-Strengthened Structural Identification and Empirical Justification of Glucuronidation Metabolites for Chrysophanol and Physcion
Xiao-Yun LI ; Hang-Yun HE ; Mao-Dong WANG ; Yu-Xuan ZHOU ; Hui JIN ; Qian WANG ; Yue-Lin SONG
Chinese Journal of Analytical Chemistry 2025;53(4):652-659,中插29-中插30
Chrysophanol(Chr)and physcion(Phy)are primary active ingredients of a well-known traditional Chinese medicine namely rhubarb(Chinese name:Dahuang),and their glucuronides have been revealed as the dominant forms presenting in rats after oral administration.Either Chr or Phy has two glycosylation sites,resulting in a pair of positional isomers for glucuronides of either compound(CG1&CG2 and PG1&PG2).To confirmatively identify these glucuronides,energy-resolved mass spectrometry(ER-MS)was used to pursue the fragmentation trajectories of the targeted fragment ions,and the resultant breakdown graphs that were described by the optimal collision energy(OCE)were expected to exhibit the differences of glycosidic bond cleavage between the isomers.Quantum chemical calculation was thereafter conducted to produce the bond dissociation energy(BDE)of the glycosidic bonds.The isomers were unambiguously identified through applying the positive correlation rule between OCE and BDE.Fortunately,the glucuronides of Chr and Phy in vivo were observed through liver microsomes incubationin vitro.ER-MS was utilized to collect the Gaussian-shaped breakdown graphs in response to the neutral loss of 176 Da,and the absolute values of OCE were compared between positional isomers.The results revealed that CG1(-32.31 eV)>CG2(-31.61 eV),and nonetheless,PG1(-30.00 eV)
9.Design and verification of accurate measurement of human body mass in microgravity environment
Zhe ZHANG ; Weibo LIU ; Zhi XU ; Yan ZHANG ; Jianping GUO ; Yu ZHANG ; Sheng Yuan WANG ; Yong XUAN ; Yue GAO ; Mi JIANG
Space Medicine & Medical Engineering 2025;36(1):50-57
Traditional mass measurement methods are not applicable in microgravity environments,and the main challenge for in-orbit body mass measurement technology based on inertial principles is to address the random errors brought about by the weightless environment.These include additional torques due to shifts in the center of mass,nonlinear accelerations due to non-rigid human bodies,mechanical energy consumption due to organ vibrations,and random vibrations of the measurement device itself.To address the above difficulties,the project proposes a technical scheme based on the principle of linear acceleration,designs and constructs a ground-specific air-floating experimental and simulation platform,studies key data such as motion trajectory,acceleration change,and vibration frequency amplitude during the mass measurement process,and simulates the changes in the center of mass and random vibrations of the human body in a weightless environment.The project has designed an adjustable posture bracket to adapt to changes in the center of mass,enhance body restraint,and greatly reduce shaking;it has also developed an integrated four-bar linkage motion guidance mechanism,high-precision integrated photoelectric distance measurement,and modular motion constant force measurement device to ensure the accurate measurement of acceleration and constant force data.The product has undergone simulation calculations,ground human applicability tests,and in-orbit applicability verification in the space station.Ground test results show that the device achieves a body mass measurement accuracy better than 0.5%,and the dispersion is better than 0.38%;after flight mission verification and evaluation,the in-orbit body mass measurement dispersion is less than 0.4%,which is superior to the SLAMMD,a mass measurement device of the same principle on the International Space Station,and is at the forefront internationally,achieving accurate body mass measurement.
10.Electrocardiogram signal quality estimation by the similarity of heartbeat morphology and wave slope character
Yu ZHANG ; Zhi XU ; Xinming YU ; Jinzhong SONG ; Zhongping CAO ; Linghao XIONG ; Yong XUAN
Space Medicine & Medical Engineering 2025;36(3):225-229
Objective Electrocardiogram(ECG)signal quality degrades when the level of activity is high and motion artifacts are severe.Poor quality signals may result in false alarms,poor patient monitoring,imprecise measurement,and misleading diagnosis.The quantitative assessment of ECG signal quality forms the basis of automatic ECG noise reduction and heart disease diagnosis.Methods The ECG signal quality index(SQI)was obtained by statistically analyzing the heartbeat similarity and the slope character,respectively,namely rSQI and kSQI.Results Using MIT-BIH Noise Stress Test Database to test,both rSQI and kSQI decreased when the Signal Noise Ratio(SNR)decreased,which revealed the ECG signal quality.Based on the quasiperiodic property,the waveform similarity,as a beat-to-beat index,is obtained by cross correlation between two ECG cycles with high precision but heavy computation.Slope-based method dispenses with QRS detection and is very simple and real-time,but its sensitivity is lower than similarity-based method and it only get statistical data.Conclusion Both morphology similarity and slope character algorithms could provide objective estimation of ECG quality.Slope-based method is an attractive measure due to its simplicity and mathematical convenience,while similarity-based method is more accurate and robust for ECG quality assessment.