1.Optimal b-Value Sets Based on Intravoxel Incoherent Motion in Pulmonary Solid Benign and Malignant Lesions
Wei WEI ; Heng LI ; Na ZHAO ; Chanjuan YU ; Xiuzheng YUE ; Zhiwei SHEN ; Xiangfei CHEN ; Sheng ZHANG ; Xiao YANG ; Yuedong HAN
Chinese Journal of Medical Imaging 2025;33(8):834-839
Purpose To quantitatively compare the diffusion parameters of mono-and biexponential diffusion-weighted imaging models,and to obtain optimal sets of b-values in diffusion-weighted MRI for obtaining monoexponential apparent diffusion coefficient(ADC)close to perfusion-insensitive intravoxel incoherent motion(IVIM)model ADC(ADCIVIM)in identifying of pulmonary solid benign and malignant lesions.Materials and Methods IVIM was performed in 40 patients with solid nodule and masse in Xi'an Gaoxin Hospital from July 2021 to August 2022 using a 3.0T MR imager.Two experienced diagnostic radiologists subjectively evaluated the IVIM images.A single index model was used to calculate ADC values(ADC0-1 000,ADC20-1 000,ADC50-1 000,ADC80-1 000,ADC150-1 000,ADC300-1 000,ADC500-1 000,ADC300,500,1 000,ADC300,800,1 000,ADC300,500,ADC300,800 and ADC300,1 000).The reference standard ADCIVIM value were calculated using a double-exponential model.The physician's measurements between two physicians were measured.The malignant and benign groups were compared and receiver operator characteristic curve for all parameters were analyzed.Results The measurement consistency of ADC values under b value sets and ADCIVIM was very good,and the intraclass correlation coefficient was more significant than 0.75.The differences between ADCIVIM and ADC values in each b group were statistically significant(t=-6.016--2.500,all P<0.05).The area under the curve(AUC)of ADCIVIM was the largest(0.906),with an optimal threshold of 1.271×10-3 mm2/s,a sensitivity of 80.0%and a specificity of 93.0%.The diagnostic efficacy close to ADCIVIM were ADC300,800(AUC=0.891),ADC50-1 000(AUC=0.827)and ADC300,800,1 000(AUC=0.795),respectively.The optimal threshold of ADC300,800 was 1.140×10-3 mm2/s,the sensitivity and specificity were 80.0%and 93.7%,respectively.Conclusion Combining b-values 300 s/mm2 and 800 s/mm2 is recommended as routine scanning parameters for identifying the insensitive monoexponential ADC between benign and malignant solid pulmonary lesions.
2.MR Three-Dimensional Multi-Echo Ultrashort Echo Time Quantitative Technique in Differential Diagnosis in Benign and Malignant Pulmonary Nodules and Masses
Heng LI ; Wei WEI ; Xiao YANG ; Na ZHAO ; Xiuzheng YUE ; Yuedong HAN
Chinese Journal of Medical Imaging 2025;33(10):1115-1119
Purpose To explore the value of quantitative parameters(T2* value,R2* value)of three-dimensional multi-echo ultrashort echo time technique for the differential diagnosis of benign and malignant pulmonary nodules and masses(PNMs).Materials and Methods The MRI data of 68 patients with PNMs in Xi'an Gaoxin Hospital from July 2021 to October 2022 were retrospectively analyzed,and PNMs were grouped into benign(34 cases)and malignant(34 cases)categories using histopathology or clinical follow-up as the reference standard.Two observers respectively outlined the regions of interest on three-dimensional multi-echo ultrashort echo time-T2* and R2* maps,and quantitatively measured the T2* and R2* values.The intraclass correlation coefficient(ICC)was used to evaluate the consistency of the measured values.Differences in the above indicators between the two groups of PNMs were analyzed,and their diagnostic efficacy was assessed.The predictive probability of the combined two indicators was computed,the receiver operating characteristic curve was plotted,and the area under the curve(AUC)was calculated.Results The measurement results of each parameter of PNMs in the benign and malignant groups by the two observers were consistent(ICC>0.75).The T2* value of the malignant group was higher than that of the benign group(Z=-5.158,P<0.001),and the R2* value was lower than that of the benign group(Z=-4.845,P<0.001),and the differences were statistically significant.The AUC of the T2* value was 0.864(95%CI 0.775-0.953,P<0.001),with a maximum Youden index of 0.677,a threshold of 9.675 ms,a sensitivity of 76.5%,and a specificity of 91.2%.The AUC of the R2* value was 0.842(95%CI 0.746-0.937,P<0.001),with a maximum Youden index of 0.647,and a threshold of 109.15/s,with a sensitivity of 73.5%and a specificity of 91.2%.The AUC of the combined diagnosis of T2* and R2* values was 0.867(95%CI 0.779-0.955,P<0.001),with a maximum Youden index of 0.677,a sensitivity of 82.4%,and a specificity of 85.3%.There was no statistically significant difference in the pairwise comparison of T2* values,R2* values,and their combined AUC(all P>0.05).Conclusion The T2* value and R2* value of the three-dimensional multi-echo ultrashort echo time technique,as well as the combination of the two indicators,are all helpful in differentiating benign and malignant PNMs,providing imaging support for the preoperative non-invasive and precise differentiation of PNMs and optimizing clinical diagnosis and treatment decisions.
3.MR Three-Dimensional Multi-Echo Ultrashort Echo Time Quantitative Technique in Differential Diagnosis in Benign and Malignant Pulmonary Nodules and Masses
Heng LI ; Wei WEI ; Xiao YANG ; Na ZHAO ; Xiuzheng YUE ; Yuedong HAN
Chinese Journal of Medical Imaging 2025;33(10):1115-1119
Purpose To explore the value of quantitative parameters(T2* value,R2* value)of three-dimensional multi-echo ultrashort echo time technique for the differential diagnosis of benign and malignant pulmonary nodules and masses(PNMs).Materials and Methods The MRI data of 68 patients with PNMs in Xi'an Gaoxin Hospital from July 2021 to October 2022 were retrospectively analyzed,and PNMs were grouped into benign(34 cases)and malignant(34 cases)categories using histopathology or clinical follow-up as the reference standard.Two observers respectively outlined the regions of interest on three-dimensional multi-echo ultrashort echo time-T2* and R2* maps,and quantitatively measured the T2* and R2* values.The intraclass correlation coefficient(ICC)was used to evaluate the consistency of the measured values.Differences in the above indicators between the two groups of PNMs were analyzed,and their diagnostic efficacy was assessed.The predictive probability of the combined two indicators was computed,the receiver operating characteristic curve was plotted,and the area under the curve(AUC)was calculated.Results The measurement results of each parameter of PNMs in the benign and malignant groups by the two observers were consistent(ICC>0.75).The T2* value of the malignant group was higher than that of the benign group(Z=-5.158,P<0.001),and the R2* value was lower than that of the benign group(Z=-4.845,P<0.001),and the differences were statistically significant.The AUC of the T2* value was 0.864(95%CI 0.775-0.953,P<0.001),with a maximum Youden index of 0.677,a threshold of 9.675 ms,a sensitivity of 76.5%,and a specificity of 91.2%.The AUC of the R2* value was 0.842(95%CI 0.746-0.937,P<0.001),with a maximum Youden index of 0.647,and a threshold of 109.15/s,with a sensitivity of 73.5%and a specificity of 91.2%.The AUC of the combined diagnosis of T2* and R2* values was 0.867(95%CI 0.779-0.955,P<0.001),with a maximum Youden index of 0.677,a sensitivity of 82.4%,and a specificity of 85.3%.There was no statistically significant difference in the pairwise comparison of T2* values,R2* values,and their combined AUC(all P>0.05).Conclusion The T2* value and R2* value of the three-dimensional multi-echo ultrashort echo time technique,as well as the combination of the two indicators,are all helpful in differentiating benign and malignant PNMs,providing imaging support for the preoperative non-invasive and precise differentiation of PNMs and optimizing clinical diagnosis and treatment decisions.
4.Optimal b-Value Sets Based on Intravoxel Incoherent Motion in Pulmonary Solid Benign and Malignant Lesions
Wei WEI ; Heng LI ; Na ZHAO ; Chanjuan YU ; Xiuzheng YUE ; Zhiwei SHEN ; Xiangfei CHEN ; Sheng ZHANG ; Xiao YANG ; Yuedong HAN
Chinese Journal of Medical Imaging 2025;33(8):834-839
Purpose To quantitatively compare the diffusion parameters of mono-and biexponential diffusion-weighted imaging models,and to obtain optimal sets of b-values in diffusion-weighted MRI for obtaining monoexponential apparent diffusion coefficient(ADC)close to perfusion-insensitive intravoxel incoherent motion(IVIM)model ADC(ADCIVIM)in identifying of pulmonary solid benign and malignant lesions.Materials and Methods IVIM was performed in 40 patients with solid nodule and masse in Xi'an Gaoxin Hospital from July 2021 to August 2022 using a 3.0T MR imager.Two experienced diagnostic radiologists subjectively evaluated the IVIM images.A single index model was used to calculate ADC values(ADC0-1 000,ADC20-1 000,ADC50-1 000,ADC80-1 000,ADC150-1 000,ADC300-1 000,ADC500-1 000,ADC300,500,1 000,ADC300,800,1 000,ADC300,500,ADC300,800 and ADC300,1 000).The reference standard ADCIVIM value were calculated using a double-exponential model.The physician's measurements between two physicians were measured.The malignant and benign groups were compared and receiver operator characteristic curve for all parameters were analyzed.Results The measurement consistency of ADC values under b value sets and ADCIVIM was very good,and the intraclass correlation coefficient was more significant than 0.75.The differences between ADCIVIM and ADC values in each b group were statistically significant(t=-6.016--2.500,all P<0.05).The area under the curve(AUC)of ADCIVIM was the largest(0.906),with an optimal threshold of 1.271×10-3 mm2/s,a sensitivity of 80.0%and a specificity of 93.0%.The diagnostic efficacy close to ADCIVIM were ADC300,800(AUC=0.891),ADC50-1 000(AUC=0.827)and ADC300,800,1 000(AUC=0.795),respectively.The optimal threshold of ADC300,800 was 1.140×10-3 mm2/s,the sensitivity and specificity were 80.0%and 93.7%,respectively.Conclusion Combining b-values 300 s/mm2 and 800 s/mm2 is recommended as routine scanning parameters for identifying the insensitive monoexponential ADC between benign and malignant solid pulmonary lesions.
5.Influencing Factors of Three-Dimensional Amide Proton Transfer Weighted Imaging on Right Kidney in Normal Chinese
Gang TIAN ; Xia WANG ; Na ZHAO ; Chaoqun BU ; Xiuzheng YUE ; Yuedong HAN
Chinese Journal of Medical Imaging 2024;32(2):175-179
Purpose The study aims to investigate the effects of various ages,genders and body mass index(BMI)on amide proton transfer weighted(APTw)in the right kidney of normal Chinese.Materials and Methods A total of 182 healthy volunteers enrolled from September 2021 to February 2022 at Xi'an GaoXin Hospital were prospectively performed.There were 7 groups(11-80 years)according to age per 10 years;2 groups according to gender,male and female;4 groups according to BMI,slim group,normal group,overweight group and obese group.3D-APTw imaging of the right kidney was performed via intermittent breath-holding.The correlation between APT values and age and BMI was analyzed,and the differences in APT values between age groups,different BMI groups and gender were analyzed,respectively.Results A total of 131 cases were finally included.There was a weak positive correlation between APT and age(r=0.325,P<0.001).There were statistical difference in APT values among different age groups(F=3.566,P=0.003),the post-hoc analysis showed that the APT values of 11-20 years[(1.853±0.357)%]old group was significantly lower than those of 41-50 years[(2.387±0.432)%]old group and 51-60 years[(2.336±0.451)%]old group(P<0.05);the APT value of male[1.980(2.320,1.820)%]was significantly lower than that of female[2.284(2.586,1.825)%;Z=2.301,P=0.021].There was a very weak positive correlation between APT and BMI(r=0.181,P=0.039),with statistically different APT values among BMI groups(F=3.265,P=0.024).The results of intra-group analysis showed that APT values in emaciation group were significantly lower than those in normal group,overweight group and obesity group,respectively(all P<0.05).Conclusion The APT value of the right kidney may be correlated with age and BMI,with males lower than females.The effect of age,gender and BMI on APT on the clinical application of 3D-APTw may be considered.
6. Research progress of traditional Chinese medicine treating diabetes with pulmonary tuberculosis
Xiuzheng WANG ; Hao ZHANG ; Lili DIAO ; Dong WANG ; Rui LI ; Lei ZHAO ; Yanqing TIAN
International Journal of Traditional Chinese Medicine 2020;42(2):189-191
This paper reviewed the literatures of TCM treating diabetes mellitus and pulmonary tuberculosis from two aspects, Chinese patent medicine and TCM decoctions, which showed that TCM therapy can control blood sugar levels, improve clinical symptoms such as cough, expectoration and wheezing, promote pulmonary tuberculosis lesion absorption, cavity closure and sputum vaginal discharge, and improve patients' quality of life.
7.Correlation between heart rate deceleration, serum homocysteine and coronary artery lesion in coronary heart disease patients with hypertension
Lingyan DING ; Xiling ZHAO ; Lei ZHANG ; Yan LIU ; Xiuzheng LI
Chinese Journal of Primary Medicine and Pharmacy 2020;27(15):1798-1802
Objective:To explore the correlation between the level of heart rate deceleration (DC), serum homocysteine(Hcy), the scope and extent of coronary artery lesion in coronary heart disease patients with hypertension.Methods:From January 2019 to October 2019, 103 coronary heart disease patients with hypertension who were diagnosed and hospitalized in cardiovascular department of Binzhou Central Hospital were selected as coronary heart disease(CHD) group, and 52 patients with simple hypertension were selected as control group.The serum Hcy levels of the two groups were measured and analyzed.The DC value and the difference of the two groups were analyzed.The degree of coronary artery lesion was evaluated by the number of coronary artery lesion and Gensini score.The relationship between DC, Hcy and the degree of coronary artery lesion was analyzed.Results:Compared with the control group, the DC value of CHD group was significantly lower [(6.02±1.97)ms vs.(4.97±1.59)ms, t=-3.989, P<0.05], and the serum Hcy level was increased [(11.46±4.38)μmol/L vs.(16.79±6.31)μmol/L, t=4.260, P<0.05]. In the CHD group, the DC values and Gensini scores of the patients with single vessel lesion, double vessel lesions and three vessel lesions were (5.52±1.34)ms, (5.06±1.29)ms, (4.39±1.19)ms, (21.35±17.10)points, (26.93±18.18)points, (49.39±30.14)points, respectively.The DC value of patients with three vessel lesions was lower than that of patients with single vessel lesion( F=7.349, P<0.05), and the Gensini score was higher( F=13.487, P<0.05). There were no statistically significant differences in DC value and Gensini score between patients with three vessel lesions and those with two vessel lesions and those with single vessel lesion( P>0.05). The serum Hcy levels of patients with single, double and three vessel lesions were (14.67±5.97)μmol/L, (15.85±6.29)μmol/L and (16.97±7.13)μmol/L, respectively.The difference among the three groups was statistically significant ( F=12.427, P<0.05). There was a negative correlation between DC and Gensini score( r=-0.310, P<0.05), and a positive correlation between serum Hcy and Gensini score( r=0.369, P<0.05). Conclusion:The DC value and Hcy level in coronary heart disease patients with hypertension are significantly decreased, which are closely related to the degree of coronary artery lesion.
8. Synthesis and Anti-tumor Activity of New Rotundic Acid Derivatives
Min-lun NAN ; Yu-fang HE ; Xue-ling SI ; Yu-wei ZHAO ; Xue WANG ; Xue BAI ; Chuan-jing LI
Chinese Journal of Experimental Traditional Medical Formulae 2019;25(11):139-144
Objective:To design and synthesize series of rotundic acid derivatives by introducing aromatic ester groups with rotundic acid as the parent nucleus, test their anti-tumor activity in vitro,investigate the structure-activity relationship of rotundic acid derivatives in inhibiting tumor cell proliferation, and obtain the novel rotundic acid derivatives with high anti-tumor activity. Method:Compounds 1-8 were synthesized with rotundic acid as the initial raw material through the 28-etherification,3β and 23di-aromatic esterification eaction. The anti-tumor activities in vitro were evaluated by MTT assay against A375 (human malignant melanoma cells),HeLa (human cervical cancer cells),SPC-A1 (human lung adenocarcinoma cells),and HepG2 (human liver cancer cells). Result:Compounds 2-8 were new compounds. Their structures were identified by melting point (MP),high resolution electrospray ionization tandem mass spectrometry (HR-ESI-MS),1H nuclear magnetic resonance (1H-NMR) and 13 C nuclear magnetic resonance (13 C-NMR). MTT results showed that compounds 3,5 and 8 exhibited significant anti-tumor activity, especially compound 5 was found to have the best inhibition activity on HeLa,A375, HepG2 and SPC-A1 with IC50 values of (5.25±1.08),(5.99±0.88),(3.31±1.89),(5.74±1.78) μmol·L-1, 1.92,3.22,3.79, 3.72 times of that of rotundic acid,respectively. Conclusion:Compound 5 has significant anti-tumor activity with great significance for further research and development of new anti-tumor medicines.
9.Study on Synthesis and Identification of Rotundic Acid Esters Derivatives and in vitro Antitumor Activity
Minlun NAN ; Yufang HE ; Xueling SI ; Yuwei ZHAO ; Xue WANG ; Xue BAI ; Chuanjing LI
China Pharmacy 2019;30(5):591-595
OBJECTIVE: To synthesize and identify rotundic acid esters derivatives, and to evaluate in vitro antitumor activity. METHODS: Using rotundic acid as raw material, rotundic acid esters derivatives were synthesized by 28-esterification, 3β and 23-position hydroxyl group combined with acid anhydride. The structure of rotundic acid esters derivatives were identified by HRMS, 1H-NMR, 13C-NMR and physicochemical properties. The in vitro antitumor activities were evaluated by MTT assay against paclitaxel (positive control), rotundic acid and rotundic acid esters derivatives with human cervical cancer cells HeLa, human malignant melanoma cells A375, human lung adenocarcinoma cells SPC-A1 and human liver cancer cells HepG2 (take IC50 as an indicator). RESULTS: Totally 6 kinds of rotundic acid esters derivatives were synthesized, i.e. rotundic acid methyl ester(compound 1), 3, 23-O-di(acetyl) rotundic acid methyl ester(compound 2), 3, 23-O-di(propionyl) rotundic acid methyl ester(compound 3), 3, 23-O-di(butyryl) rotundic acid methyl ester(compound 4), 3, 23-O-di(phthaloyl) rotundic acid methyl ester(compound 5) and 3, 23-O-di(succinyl) rotundic acid methyl ester(compound 6). Compared with paclitaxel, the antitumor activity of compound 5 and compound 6 to Hela, A375, HepG2 and SPC-A1 was similar to it, and there was no significant difference between them (P>0.05); the IC50 of rotuntic acid and other compounds decreased with statistical significance (P<0.05). CONCLUSIONS: In the study, 6 kinds of rotundic acid esters derivatives are synthesized and compound 5 and compound 6 have significant antitumor activity in vitro, which can provide reference for further study.
10.Research progress in sinomenine structural modification
Xiuzheng LI ; Qingjie ZHAO ; Jiaxiao DONG ; Yunyun JIANG ; Guangming YE
Journal of Pharmaceutical Practice 2018;36(3):204-209,214
Sinomenine is an alkaloid found in the climbing plant Sinomenium acutum.Structurally,it belongs to the iso-quinoline derivatives,which have various bioactivities.Clinically,it is used in the treatment for rheumatism,rheumatoid arthri-tis and arrhythmia,etc.Nevertheless,due to the need of large dose,photo and thermal instability,quick metabolism in vivo and highly allergic for some patients,scientists have committed to modify its structure to develop the highly effective and low toxic derivatives.In this paper,the recent advances in structural modification of sinomenine are reviewed.