1.The seroepidemiological characteristics of Toxoplasma gondii infection among blood donors in Jiangxi Province
Yanglin ZHUANG ; Xinyu GUO ; Fang WANG ; Dan CHEN
Chinese Journal of Blood Transfusion 2025;38(12):1673-1677
Objective: To investigate the current status of Toxoplasma gondii (T. gondii) infection among blood donors in Jiangxi Province, thereby providing scientific evidence for ensuring blood transfusion safety. Methods: Serum samples from 1 529 blood donors were tested for T. gondii IgG and IgM antibodies using enzyme-linked immunosorbent assay (ELISA). Positive samples were further analyzed by B1 gene PCR testing and Giemsa staining microscopy. Risk factor data were collected via telephone follow-up. Infection rate differences were analyzed using χ
tests. Results: The overall T. gondii infection rate among blood donors was 3.92% (60/1 529), with IgG positivity being predominant (3.86%) and IgM positivity at 0.20%. All antibody-positive samples tested negative for T. gondii DNA. Blood group AB donors had the highest infection rate (7.00%), whereas group O donors had the lowest rate (2.47%), with a statistically significant difference (χ
=8.27, P<0.05). The infection rate in the 46-55 age group was higher than that in the 18-25 age group, χ
=4 237.75, P<0.05. No significant differences were observed across subgroups stratified by sex, occupation, or education level. Multivariate analysis identified cat/dog ownership (χ
=28.23, P<0.05), and frequent consumption of cold dishes (χ
=4.09, P<0.05) as key risk factors. Conclusion: In Jiangxi province, T. gondii infection among blood donors is predominantly characterized by past infection, with higher infection rates observed in blood type AB donors and those aged 46-55. The main risk factors include contact with cats/dogs as pets and frequent consumption of cold dishes. It is recommended to disseminate health knowledge on toxoplasmosis prevention in communities and schools to reduce the transfusion transmission risk.
2.Three-dimensional finite element analysis of three-dimensional printed personalized orthodontic appliances for vertical movement of single teeth
Yilin CAO ; Xinyu WANG ; Yan ZHUANG ; Yaru WANG ; Zhixiu JIANG ; Danyu LIU ; Jiuxu MEN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(16):3360-3368
BACKGROUND:Based on the principle of vertical tooth movement,a personalized orthodontic appliance is created through digital design combined with 3D printing,so that the personalized orthodontic appliance forms a support system with the individual incisors.With the help of the absolute support of the micro-implant,the single tooth is precisely controlled in a three-dimensional direction.OBJECTIVE:To design personalized orthodontic appliances with 11,12,21,and 22 intrusion and extrusion based on biomechanical principles,and analyze the safety of the personalized orthodontic appliances in terms of their movement effect on the teeth by means of the three-dimensional finite element method.METHODS:Three-dimensional finite element models of alveolar bone-periodontium-maxillary incisors-personalized cantilever micro-implant-connecting plates-personalized brackets in the maxillary anterior region(teeth numbers 11,12,21,and 22)were established using Mimics,Geomagic Wrap,SolidWorks,and Ansys Workbench software,respectively.Personalized orthodontic appliances with low pressure movement and extended movement were set up at each tooth position.The stress level of each component of the personalized orthodontic appliances was analyzed,and the tooth displacement and periodontal stress distribution were calculated under loading of 300 g tensile or thrust force.RESULTS AND CONCLUSION:(1)The maximum equivalent force on the personalized intrusion mobile orthodontic appliance was 162.90 MPa,and the maximum equivalent force on the personalized extrusion mobile orthodontic appliance was 239.57 MPa.The maximum equivalent stress on both devices was located in the vertical portion of the personalized bracket loading attachment.The equivalent stresses on each part of the personalized orthodontic appliance were all within the yield strength,and they had good safety.(2)The initial displacement of the teeth under the action of the personalized orthodontic appliances showed a tendency towards overall intrusion or extrusion,with the displacement in the vertical direction far exceeding that in the horizontal and sagittal directions.The equivalent stress peak appeared at the root tip or neck of the periodontal membrane,and the equivalent stress concentration area appeared in the periodontal membrane of the root apical region.(3)The results show that the personalized orthodontic appliance allows 11,12,21,and 22 to approximate either intrusion movement or extrusion movement,initially confirming the effectiveness of the personalized vertical movement orthodontic appliance.
3.Evidence-based guideline for diagnosis and early fixation of severe open tibiofibular fractures (version 2025)
Yongjun RUI ; Yongqing XU ; Qingtang ZHU ; Xin WANG ; Zhao XIE ; Shanlin CHEN ; Jingyi MI ; Xianyou ZHENG ; Juyu TANG ; Xiaoheng DING ; Aixi YU ; Tao SONG ; Jianxi HOU ; Jian QI ; Xinyu FAN ; Jun FEI ; Lin GUO ; Xingwen HAN ; Weixu LI ; Aiguo WANG ; Yun XIE ; Tao XING ; Meng LI ; Baoqing YU ; Yan ZHUANG ; Xiaoqing HE ; Tao SUN ; Pengcheng LI ; Jihui JU ; Hongxiang ZHOU ; Haidong REN ; Guangyue ZHAO ; Gang ZHAO ; Yongwei WU ; Jun LIU ; Yunhong MA ; Yapeng WANG
Chinese Journal of Trauma 2025;41(11):1021-1034
Severe open tibiofibular fractures account for approximately 28.1% of all open fractures. Among them, Gustilo-Anderson type IIIB/C fractures present significant clinical challenges due to associated bone and soft tissue defects, high infection rates, and risk of amputation. Inadequate preoperative assessment may lead to suboptimal emergency surgical planning or intraoperative complications. Historically, external fixation was often preferred, but this approach has been associated with limitations such as restricted joint mobility, delayed bone union, joint stiffness, and disuse osteoporosis, resulting in poor functional recovery. With advancements of debridement techniques, standardization of antibiotic use, and popularization of early soft tissue coverage, early internal fixation has gained broader acceptance. Nevertheless, controversies persist regarding the choice of fixation method, timing of definitive fixation, use of reamed versus unreamed intramedullary nailing, and necessity of fibular fixation. To standardize the diagnosis and early management of severe open tibiofibular fractures, reduce complication rates, and improve functional recovery, the Society of Microsurgery of the Chinese Medical Association organized a panel of domestic experts to develop the Evidence-based guideline for the diagnosis and early fixation of severe open tibiofibular fractures ( version 2025), using evidence-based methodology. The guidelines provided 12 recommendations covering diagnostic and early fixation strategies of severe open tibiofibular fractures, aiming to provide clinicians with scientifically grounded and standardized guidance.
4.Application of subcutaneous soft tissue expanders
Xinyu CONG ; Mengqi ZHAO ; Shubo ZHUANG
Chinese Journal of Plastic Surgery 2025;41(10):1001-1009
Soft tissue expansion technology is a technique that involves placing a tissue expander under the skin and gradually expanding the surrounding soft tissue with tension as the volume of the tissue expander increases. In this paper, the application progress of subcutaneous soft tissue expanders is discussed, with emphasis on the advantages and disadvantages of water-filled and self-inflating hydrogel expanders. The water-filled expander has good controllability, but the procedure is relatively complex and the risk of complications is high. The self-inflating hydrogel expander simplifies the surgical procedure and improves patient comfort, but the expansion speed is difficult to control. The article also discusses the research and application of some new expanders, exploring future research directions and clinical application prospects.
5.Construction and application of a decision support education program on hospice care for family members of patients with advanced cancer
Changlian CHEN ; Shumei ZHUANG ; Jiayan CAO ; Xiwei CHEN ; Xuya HAN ; Xinyu TANG ; Jinjing XIE ; Wanmin QIANG
Chinese Journal of Nursing 2025;60(11):1344-1351
Objective To construct a decision support education program for the family members of patients with advanced cancer and to investigate its application effects,so as to improve understanding and acceptance of hospice care for family members of advanced cancer patients.Methods Using the Ottawa Decision Support Framework as a theoretical guide,the program was initially drafted based on a literature review,qualitative interview and expert consultation.From September 2023 to January 2024,a convenience sampling method was used to select patients' families in a tertiary-level hospital in Tianjin as the research subjects,and they were randomly divided into an experimental group and a control group.The experimental group received the decision support education program in addition to routine care,while the control group received routine care.Family members' knowledge about hospice,the scores on the Death Attitude Profile Scale,and their willingness to choose hospice care were compared before and after the interventions.Results The program finally included 4 first-level items,15 second-level items,and 59 third-level items.During the program implementation phase,4 cases withdrew from the study,resulting in 46 cases in the experimental group and 47 cases in the control group.After intervention,the experimental group had higher scores on hospice knowledge and positive attitude towards death than the control group,while scores on negative attitude towards death were lower(P<0.05);their willingness to choose hospice care for themselves and for the patients was higher than that of the control group(P<0.05).Conclusion The hospice care decision support education program is scientific,feasible and practical,which can improve the knowledge of hospice care of the family members,improve their attitude towards death,and ultimately improve their willingness to choose hospice care.
6.Evidence-based guideline for diagnosis and early fixation of severe open tibiofibular fractures (version 2025)
Yongjun RUI ; Yongqing XU ; Qingtang ZHU ; Xin WANG ; Zhao XIE ; Shanlin CHEN ; Jingyi MI ; Xianyou ZHENG ; Juyu TANG ; Xiaoheng DING ; Aixi YU ; Tao SONG ; Jianxi HOU ; Jian QI ; Xinyu FAN ; Jun FEI ; Lin GUO ; Xingwen HAN ; Weixu LI ; Aiguo WANG ; Yun XIE ; Tao XING ; Meng LI ; Baoqing YU ; Yan ZHUANG ; Xiaoqing HE ; Tao SUN ; Pengcheng LI ; Jihui JU ; Hongxiang ZHOU ; Haidong REN ; Guangyue ZHAO ; Gang ZHAO ; Yongwei WU ; Jun LIU ; Yunhong MA ; Yapeng WANG
Chinese Journal of Trauma 2025;41(11):1021-1034
Severe open tibiofibular fractures account for approximately 28.1% of all open fractures. Among them, Gustilo-Anderson type IIIB/C fractures present significant clinical challenges due to associated bone and soft tissue defects, high infection rates, and risk of amputation. Inadequate preoperative assessment may lead to suboptimal emergency surgical planning or intraoperative complications. Historically, external fixation was often preferred, but this approach has been associated with limitations such as restricted joint mobility, delayed bone union, joint stiffness, and disuse osteoporosis, resulting in poor functional recovery. With advancements of debridement techniques, standardization of antibiotic use, and popularization of early soft tissue coverage, early internal fixation has gained broader acceptance. Nevertheless, controversies persist regarding the choice of fixation method, timing of definitive fixation, use of reamed versus unreamed intramedullary nailing, and necessity of fibular fixation. To standardize the diagnosis and early management of severe open tibiofibular fractures, reduce complication rates, and improve functional recovery, the Society of Microsurgery of the Chinese Medical Association organized a panel of domestic experts to develop the Evidence-based guideline for the diagnosis and early fixation of severe open tibiofibular fractures ( version 2025), using evidence-based methodology. The guidelines provided 12 recommendations covering diagnostic and early fixation strategies of severe open tibiofibular fractures, aiming to provide clinicians with scientifically grounded and standardized guidance.
7.Current status and influencing factors of intrinsic capacity in elderly patients with Parkinson's disease based on health ecology model
Yan ZHANG ; Fan JI ; Mengya HAN ; Xinyu ZHAO ; Ludan XU ; Huanhuan FENG ; Ping ZHUANG ; Wei SHU ; Binru HAN
Chinese Journal of Modern Nursing 2025;31(22):2962-2972
Objective:To explore the current status and influencing factors of intrinsic capacity in elderly patients with Parkinson's disease.Methods:Convenience sampling was used to select 306 elderly patients with Parkinson's disease who attended Xuanwu Hospital of Capital Medical University from March to September 2024 for the study. Influencing factors were screened based on the health ecology model. Elderly patients with Parkinson's disease were surveyed using the General Information Questionnaire, Connor-Davidson Resilience Scale, Family APGAR Scale, Social Support Rating Scale, and Intrinsic Capacity Assessment Tool. Multiple linear regression was used to analyze the factors influencing the total score and the scores of each dimension of intrinsic capacity in elderly patients with Parkinson's disease.Results:A total of 306 questionnaires were distributed and 301 valid questionnaires were recovered, with a valid recovery rate of 98.37% (301/306). The total intrinsic capacity score of 301 elderly patients with Parkinson's disease was (67.21±11.47), of which 297 elderly patients with Parkinson's disease had impaired intrinsic capacity, and the rate of impaired intrinsic capacity was 98.7% (297/301). The dimensions in descending order of impairment were motor [89.7% (270/301) ], mental [76.1% (229/301) ], sensory [70.4% (212/301) ], vitality [38.2% (115/301) ], and cognitive [25.6% (77/301) ]. Multiple linear regression analysis showed that age, Hoehn-Yahr staging, levodopa equivalent dosage, activity of daily living, history of falls, regular exercise, psychological resilience, social support, and monthly income were the factors influencing the total intrinsic capacity score of elderly patients with Parkinson's disease ( P<0.05) and heterogeneity of influencing factors in each dimension. Conclusions:Elderly patients with Parkinson's disease have a high rate of impaired intrinsic capacity, with the motor dimension being the most severely impaired. Healthcare professionals should pay attention to the assessment of the intrinsic capacity of elderly patients with Parkinson's disease, and customize interventions according to the influencing factors to promote the functioning of elderly patients so as to reduce the burden of care on families and society.
8.Contrast-enhanced ultrasound for evaluating DeBakey Ⅰaortic dissection involved renal artery
Yuanyuan SUN ; Lihua LI ; Hui ZHUANG ; Maolong SU ; Xinyu WANG ; Caimei CHEN ; Guoming ZHANG ; Xu CHEN
Chinese Journal of Medical Imaging Technology 2025;41(2):273-276
Objective To observe the value of contrast-enhanced ultrasound(CEUS)for evaluating DeBakey Ⅰ aortic dissection involved renal artery.Methods Totally 137 patients with DeBakey Ⅰ aortic dissection involved renal artery were retrospectively enrolled,including 132 cases involved unilateral and 5 cases involved bilateral renal arteries.The opening of totally 274 renal arteries in bilateral kidneys were observed.Taken CT angiography(CTA)as reference standard,the renal artery opened in true lumen was considered as unaffected,while opened in false lumen or true-false lumen were both considered as affected.Relative CEUS manifestations were observed,and their value for evaluating involved renal artery or not were analyzed.Results CTA showed that 132 renal arteries opened in true lumens,90 opened in false lumens and 52 opened in true-false lumens.CEUS diagnosed 131 renal arteries opened in true lumens,111 opened in false lumens and 32 opened in true-false lumens,and the sensitivity for diagnosing DeBakey Ⅰ aortic dissection involved renal artery was 90.84%,81.08%and 90.63%,respectively.The consistency between CEUS and CTA for evaluating renal artery opened in true lumen or false lumen was good(Kappa=0.786).Logistic regression analysis showed that the time to peak(TTP)and peak intensity(PI)of time intensity curve(TIC)were both impact factors for differentiating renal artery opened in true lumen or false lumen,as well as true lumen or true-false lumen(both P<0.05),while the area under the curve(AUC)of TIC was impact factor for differentiating renal artery opened in true lumen or false lumen(P<0.05).The AUC of receiver operating characteristic curve of the combination of TTP,PI and AUC of TIC for differentiating renal artery opened in true lumen or false lumen,true lumen or true-false lumen and false lumen or true-false lumen was 0.703,0.686 and 0.493,respectively.Conclusion CEUS was helpful for evaluating DeBakey Ⅰ aortic dissection involved renal artery.
9.Contrast-enhanced ultrasound for evaluating DeBakey Ⅰaortic dissection involved renal artery
Yuanyuan SUN ; Lihua LI ; Hui ZHUANG ; Maolong SU ; Xinyu WANG ; Caimei CHEN ; Guoming ZHANG ; Xu CHEN
Chinese Journal of Medical Imaging Technology 2025;41(2):273-276
Objective To observe the value of contrast-enhanced ultrasound(CEUS)for evaluating DeBakey Ⅰ aortic dissection involved renal artery.Methods Totally 137 patients with DeBakey Ⅰ aortic dissection involved renal artery were retrospectively enrolled,including 132 cases involved unilateral and 5 cases involved bilateral renal arteries.The opening of totally 274 renal arteries in bilateral kidneys were observed.Taken CT angiography(CTA)as reference standard,the renal artery opened in true lumen was considered as unaffected,while opened in false lumen or true-false lumen were both considered as affected.Relative CEUS manifestations were observed,and their value for evaluating involved renal artery or not were analyzed.Results CTA showed that 132 renal arteries opened in true lumens,90 opened in false lumens and 52 opened in true-false lumens.CEUS diagnosed 131 renal arteries opened in true lumens,111 opened in false lumens and 32 opened in true-false lumens,and the sensitivity for diagnosing DeBakey Ⅰ aortic dissection involved renal artery was 90.84%,81.08%and 90.63%,respectively.The consistency between CEUS and CTA for evaluating renal artery opened in true lumen or false lumen was good(Kappa=0.786).Logistic regression analysis showed that the time to peak(TTP)and peak intensity(PI)of time intensity curve(TIC)were both impact factors for differentiating renal artery opened in true lumen or false lumen,as well as true lumen or true-false lumen(both P<0.05),while the area under the curve(AUC)of TIC was impact factor for differentiating renal artery opened in true lumen or false lumen(P<0.05).The AUC of receiver operating characteristic curve of the combination of TTP,PI and AUC of TIC for differentiating renal artery opened in true lumen or false lumen,true lumen or true-false lumen and false lumen or true-false lumen was 0.703,0.686 and 0.493,respectively.Conclusion CEUS was helpful for evaluating DeBakey Ⅰ aortic dissection involved renal artery.
10.Three-dimensional finite element analysis of personalized orthodontic devices for 3D printed maxillary single-rooted rotated tooth
Yan ZHUANG ; Xinyu WANG ; Yilin CAO ; Yuanxin DING ; Jiaqi WANG ; Miao YU ; Chunyang LUAN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(30):6409-6415
BACKGROUND:In orthodontic treatment,full-mouth treatment is usually used to treat single-root severely twisted teeth,and single-tooth treatment is less common.OBJECTIVE:To design a personalized orthodontic device based on biomechanical principles to address the rotation of teeth 11,12,13,21,22,and 23,and evaluate the device's impact on tooth movement using three-dimensional finite element method.METHODS:Based on the biomechanical principle of tooth rotation and movement,a personalized orthodontic device was made by digital design combined with three-dimensional printing,so that the personalized orthodontic device and the tooth formed an anchorage system.The absolute anchorage of the micro-implant was used to precisely control the single-root twisted tooth in the three-dimensional direction.The CBCT data of the maxillary alveolar bone and tooth tissue of a female volunteer were collected.The three-dimensional finite element models of the twisted tooth-periodontal ligament-maxillary bone-personalized orthodontic device were established using Mimics,Geomagic Wrap,SolidWorks,3-matic Research 15.0,and Ansys Workbench software.The equivalent stress distribution characteristics of the personalized orthodontic device,the movement trend of the tooth,and the equivalent stress distribution characteristics of the periodontal ligament were calculated under a thrust of 60 g.RESULTS AND CONCLUSION:(1)The maximum equivalent stress observed on the personalized orthodontic device was 47.71 MPa.(2)The initial tooth displacement under the device demonstrated a rotational trend.The peak equivalent stress in the periodontal ligament was concentrated at the neck,while lower stress was observed in the apex region.(3)The safety and feasibility of the personalized orthodontic device designed in this study for severely rotated single-rooted teeth were preliminarily verified through finite element analysis.

Result Analysis
Print
Save
E-mail