1.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
XU Xinyi ; WEI Shifeng ; ZHANG Qiming ; HE Langchong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):045-050
Objective: To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Methods: Introduce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Results: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guidelines of the ICH Q series, and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety, efficacy, and quality controllability is further increased.
Conclusion: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China’s drugs to go international, standardized testing technology support for achieving full process quality control, and better meet the needs of drug research and development, production, quality control, and supervision in China.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Molecular characterization of FGFR fusion in a large real-world population and clinical utility of bidirectional fusion.
Xinyi ZHANG ; Jing ZHAO ; Ling MA ; Yitong TIAN ; Jiaguang ZHANG ; Hejian ZHENG ; Junling ZHANG ; Runyu HE ; Luhang JIN ; Jing MA ; Mengli HUANG ; Xiao LI ; Xiaofeng CHEN
Chinese Medical Journal 2025;138(12):1510-1512
8.Comprehensive management of tophaceous wound.
Guoyu HE ; Shuliang LU ; Xinyi LU ; Yingkai LIU
Journal of Zhejiang University. Medical sciences 2025;54(5):611-619
Tophaceous wound represent a severe complication of end-stage gout, characterized by the deposition of monosodium urate (MSU) crystals leading to localized tissue ischemia, chronic inflammation, and non-healing ulcers. The pathological mechanism involves the formation of MSU crystals under persistent hyperuricemia, inflammatory encapsulation, and mechanical compression of the vascular system due to tophus enlarge-ment, ultimately resulting in chronic non-healing ulcers. This article consolidates current evidence to outline an integrated management strategy for such wounds, combining systemic metabolic control with localized interventions. Effective treatment depends on maintaining serum uric acid levels below 300 μmol/L through urate-lowering agents, including conventional drugs and novel urate transporter 1 inhibitors such as AR882, complemented by anti-inflammatory medications such as nonsteroidal anti-inflammatory drugs and glucocorticoids to alleviate pain and reduce inflammation. Topical agents and advanced dressings are utilized to support healing and manage exudate. Debridement, which encompasses sharp, ultrasonic, and micro-techniques, is essential for removing necrotic tissue and MSU deposits, with efficacy assessed via local uric acid monitoring. Surgical reconstructions, including skin flap grafting and tendon or ligament reconstruction, are indicated for significant tissue loss or functional impairment. Long-term management emphasizes continuous metabolic control, personalized rehabilitation, and lifestyle modification. The comprehensive treatment of tophaceous wounds requires multidisciplinary collaboration to balance local repair and systemic regulation for improved prognosis. Future research directions include gene therapy to regulate purine metabolism and artificial intelligence-assisted personalized treatment plans, to achieve precision medicine for tophaceous wounds.
Humans
;
Wound Healing
;
Gout/therapy*
;
Uric Acid/blood*
;
Debridement
9.Spatially resolved metabolomics visualizes heterogeneous distribution of metabolites in lung tissue and the anti-pulmonary fibrosis effect of Prismatomeris connate extract
Jiang HAIYAN ; Zheng BOWEN ; Hu GUANG ; Kuang LIAN ; Zhou TIANYU ; Li SIZHENG ; Chen XINYI ; Li CHUANGJUN ; Zhang DONGMING ; Zhang JINLAN ; Yang ZENGYAN ; He JIUMING ; Jin HONGTAO
Journal of Pharmaceutical Analysis 2024;14(9):1330-1346
Pulmonary fibrosis(PF)is a chronic progressive end-stage lung disease.However,the mechanisms un-derlying the progression of this disease remain elusive.Presently,clinically employed drugs are scarce for the treatment of PF.Hence,there is an urgent need for developing novel drugs to address such diseases.Our study found for the first time that a natural source of Prismatomeris connata Y.Z.Ruan(Huang Gen,HG)ethyl acetate extract(HG-2)had a significant anti-PF effect by inhibiting the expression of the transforming growth factor beta 1/suppressor of mothers against decapentaplegic(TGF-β1/Smad)pathway.Network pharmacological analysis suggested that HG-2 had effects on tyrosine kinase phosphorylation,cellular response to reactive oxygen species,and extracellular matrix(ECM)disassembly.Moreover,mass spec-trometry imaging(MSI)was used to visualize the heterogeneous distribution of endogenous metabolites in lung tissue and reveal the anti-PF metabolic mechanism of HG-2,which was related to arginine biosyn-thesis and alanine,asparate and glutamate metabolism,the downregulation of arachidonic acid meta-bolism,and the upregulation of glycerophospholipid metabolism.In conclusion,we elaborated on the relationship between metabolite distribution and the progression of PF,constructed the regulatory metabolic network of HG-2,and discovered the multi-target therapeutic effect of HG-2,which might be conducive to the development of new drugs for PF.
10.A qualitative study of facilitators and hindrances of smoking cessation in patients with chronic obstructive pulmonary disease
Zheng TIAN ; Jingchun HE ; Dajun LIU ; Yimiao LI ; Xinyi LIU ; Zhijun ZHANG ; Nan ZHANG ; Lan WANG
Chinese Journal of Practical Nursing 2024;40(26):2034-2040
Objective:To investigate the facilitators and hindrances of smoking cessation in patients with chronic obstructive pulmonary disease (COPD), and to provide a basis for developing individualized smoking cessation intervention strategies for COPD patients.Methods:Based on the health ecology theory and using a phenomenological approach in qualitative research, purposive sampling was used to select 15 COPD patients with smoking history who were admitted to Tianjin Fourth Central Hospital from March to May 2023 and face-to-face semi-structured interviews were conducted. Colaizzi seven-step analysis was used to analyze the interview content.Results:A total of 15 COPD patients were interviewed, including 13 males and 2 females, aged 61-75 years old. The facilitators of smoking cessation in COPD patients included complications, sequelae of novel coronavirus infection, fear of death, smoking cessation counseling by medical staff, heavy family financial burden, and smoke-free environment. The hindrances of smoking cessation in COPD patients included milder disease symptoms of COPD, higher levels of nicotine dependence, false disease-related perceptions, family supervision and control, and occupational experience.Conclusions:Smoking cessation in COPD patients is influenced by five factors: personal characteristics, behavioral characteristics, interpersonal network, living and working conditions, and policy environment. Medical staff and relevant national institutions should formulate corresponding smoking cessation strategies according to address the facilitators and hindrances of smoking cessation in COPD patients, so as to further reduce the smoking prevalence of COPD patients, promote the health of patients and reduce the burden of disease.

Result Analysis