1.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
XU Xinyi ; WEI Shifeng ; ZHANG Qiming ; HE Langchong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):045-050
Objective: To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Methods: Introduce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Results: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guidelines of the ICH Q series, and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety, efficacy, and quality controllability is further increased.
Conclusion: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China’s drugs to go international, standardized testing technology support for achieving full process quality control, and better meet the needs of drug research and development, production, quality control, and supervision in China.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Molecular characterization of FGFR fusion in a large real-world population and clinical utility of bidirectional fusion.
Xinyi ZHANG ; Jing ZHAO ; Ling MA ; Yitong TIAN ; Jiaguang ZHANG ; Hejian ZHENG ; Junling ZHANG ; Runyu HE ; Luhang JIN ; Jing MA ; Mengli HUANG ; Xiao LI ; Xiaofeng CHEN
Chinese Medical Journal 2025;138(12):1510-1512
8.Comprehensive management of tophaceous wound.
Guoyu HE ; Shuliang LU ; Xinyi LU ; Yingkai LIU
Journal of Zhejiang University. Medical sciences 2025;54(5):611-619
Tophaceous wound represent a severe complication of end-stage gout, characterized by the deposition of monosodium urate (MSU) crystals leading to localized tissue ischemia, chronic inflammation, and non-healing ulcers. The pathological mechanism involves the formation of MSU crystals under persistent hyperuricemia, inflammatory encapsulation, and mechanical compression of the vascular system due to tophus enlarge-ment, ultimately resulting in chronic non-healing ulcers. This article consolidates current evidence to outline an integrated management strategy for such wounds, combining systemic metabolic control with localized interventions. Effective treatment depends on maintaining serum uric acid levels below 300 μmol/L through urate-lowering agents, including conventional drugs and novel urate transporter 1 inhibitors such as AR882, complemented by anti-inflammatory medications such as nonsteroidal anti-inflammatory drugs and glucocorticoids to alleviate pain and reduce inflammation. Topical agents and advanced dressings are utilized to support healing and manage exudate. Debridement, which encompasses sharp, ultrasonic, and micro-techniques, is essential for removing necrotic tissue and MSU deposits, with efficacy assessed via local uric acid monitoring. Surgical reconstructions, including skin flap grafting and tendon or ligament reconstruction, are indicated for significant tissue loss or functional impairment. Long-term management emphasizes continuous metabolic control, personalized rehabilitation, and lifestyle modification. The comprehensive treatment of tophaceous wounds requires multidisciplinary collaboration to balance local repair and systemic regulation for improved prognosis. Future research directions include gene therapy to regulate purine metabolism and artificial intelligence-assisted personalized treatment plans, to achieve precision medicine for tophaceous wounds.
Humans
;
Wound Healing
;
Gout/therapy*
;
Uric Acid/blood*
;
Debridement
9.NK cell-specific knockout of UTX modulates pulmonary metastasis of melanoma in a sex-dependent manner
Pei HUANG ; Hongchen WANG ; He HUANG ; Jiaxin XIE ; Yu WU ; Simin ZHOU ; Xinyi LIAO ; Xiao GUAN
Journal of Army Medical University 2025;47(8):807-815
Objective To explore the role of X chromosome encoded epigenetic regulator UTX in NK cell-mediated anti-tumor activity.Methods Male Ncr1-iCre mice were crossed with female UTXfl/fl mice to generate F1 Ncr1-iCre+UTXfl/-male mice,which were further crossed with female UTXfl/fl mice to obtain male Ncr1-iCre-UTX fl/-control mice(M-Con)and NK-specific deletion of UTX male mice Ncr1-iCre+UTXfl/-(M-KO),as well as female Ncr1-iCre-UTXfl/fl control mice(F-Con)and UTX-deficient female mice Ncr1-iCre+UTXfl/fl(F-KO).UTX-deficient mice were injected with melanoma cell line B16F10 via tail vein to observe pulmonary metastatic tumor nodules.Moreover,flow cytometry was applied to detect the proportion and quantity of pulmonary NK cells(CD3-CD19-NK1.1+),maturation makers KLRG1 and CD11b,activation receptors NKG2D and CD69,and effector molecules,including perforin,granzyme B,CD107a,and IFN-γ.Then pulmonary NK cells were sorted and co-cultured with B16F10 cells,and the apoptosis of the melanoma cells was measured with flow cytometry.Results Compared with the M-Con mice,the M-KO mice presented less number of pulmonary tumor nodules(P<0.05),increased proportion and quantity of NK cells in the tumor microenvironment(P<0.01),though no obvious changes in the ratio of NK maturation makers KLRG1 to CD11b,enhanced expression level of cytotoxic molecule perforin(P<0.01),but no changes in the expression of effector molecule granzyme B,degranulation marker CD107a and cytokine IFN-γ in NK cells.Co-culture of NK cells and B16F10 cells promoted the apoptosis of tumor cells(P<0.05).Compared with the F-Con mice,the F-KO mice had no statistical difference in the number of pulmonary tumor nodules,but larger proportion and number of NK cells(P<0.05),decreased ratio of KLRG1 to CD11b(P<0.01),elevated level of perforin but decreased levels of granzyme B,CD107a and IFN-γ in NK cells(P<0.01).The co-culture of NK cells and B16F10 cells reduced the apoptosis of tumor cells in F-KO female mice(P<0.05).Conclusion NK-specific deletion of UTX regulates pulmonary metastasis of melanoma in a sex-dependent manner.
10.Clinical characteristics and contributors to diagnostic delay in autoimmune gastritis
Haofeng LI ; He MA ; Tao FU ; Xinyi HUANG ; Qing SHI ; Yan ZHENG ; Hanning LIU ; Hengqi LIU ; Yan GUO ; Chunhui LAN
Journal of Army Medical University 2025;47(19):2396-2404
Objective To analyze the diagnostic process and clinical characteristics of autoimmune gastritis(AIG)in order to improve the awareness and diagnostic proficiency of this disease.Methods A retrospective cohort study was conducted on 114 patients diagnosed with AIG in Army Medical Center of PLA between January 2021 and June 2024.Comprehensive statistical analysis was performed on clinical data,including demographic characteristics(age,sex),clinical symptoms,comorbidities,diagnostic process,Helicobacter pylori(H.pylori)infection and treatment history,laboratory indicators[results of routine blood test,anemia-related indices,thyroid function,anti-parietal cell antibody(APCA),intrinsic factor antibody(IFA)],and gastrointestinal endoscopic findings(frequency and endoscopic features).Results Among the 114 patients,males accounted for 28.1%(32/114)and females for 71.9%(82/114),and they were at a mean age of 56.3±8.4 years.Predominant symptoms included epigastric/upper abdominal pain(47.4%,54/114)and postprandial fullness(43.0%,49/114),while 24.6%(28/114)reported acid reflux or heartburn.Diagnostic delay occurred in 76.4%(87/114)of patients,with a median delay duration of 11.5 months.Primary diagnostic clues were endoscopic reverse gradient atrophy(significantly more severe mucosal atrophy in the gastric corpus/fundus versus antrum;53.5%,61/114)and repeated H.pylori eradication failure(≥2 attempts;22.8%,26/114).Positivity rate of thyroid peroxidase antibody(TPOAb)and thyroglobulin antibody(TgAb)was 56.9%(33/58)and 36.2%(21/58),respectively.APCA positive rate was 98.8%(81/82),IFA positive rate was 34.1%(28/82),and dual-antibody rate was 32.9%(27/82).Anemia was present in 25.7%(26/101)of the patients.Gastric neuroendocrine tumors(NET)were found in 12.2%(14/114),intraepithelial neoplasia in 5.3%(6/114),and gastric adenocarcinoma in 0.9%(1/114).Among colonoscopy-examined patients,tubular adenomas occurred in 25.0%(13/52)and colorectal malignancies in 3.4%(2/58).There were 18.4%(21/114)patients having gallbladder-related diseases,7.9%(9/114)having diabetes mellitus,and 1.8%(2/114)of subacute combined degeneration of the spinal cord.Conclusion AIG is frequently associated with diagnostic delay.The reverse pattern of atrophy on endoscopy serves as a critical diagnostic clue,necessitating enhanced recognition in endoscopists.Patients with recurrent H.pylori eradication failure(≥2 attempts)should be evaluated for AIG.

Result Analysis