1.Evaluation of efficacy and tolerability of TCIC-001 for bowel preparation prior to colonoscopy: an exploratory randomized controlled clinical trial
Baohui SONG ; Xiaolong ZHUANG ; BAHETINUER JIASHAER ; Xiaoyue XU ; Jiaxin XU ; Danfeng ZHANG ; Yunshi ZHONG ; Pinghong ZHOU ; Mingyan CAI
Chinese Journal of Clinical Medicine 2025;32(5):743-747
Objective To compare the efficacy and tolerability of the novel bowel-cleansing agent TCIC-001 and the traditional polyethylene glycol (PEG) regimen for bowel preparation prior to colonoscopy. Methods Prospective inclusion of 62 patients who were scheduled to undergo colonoscopy at Zhongshan Hospital, Fudan University from July 2021 to July 2022. They were randomly divided into TCIC-001 group (n=31) and PEG group (n=31) using a random number table method. The TCIC-001 group took TCIC-001 orally, drinking water in stages, with a total liquid intake of 1 500 mL; the PEG group took PEG orally, taking it in 4 doses, with a total liquid intake of 3 000 mL. The primary endpoint indicator is the quality of intestinal hygiene evaluated by the Boston Bowel Preparation Scale (BBPS), the secondary endpoint indicators were medication adherence, medication duration, frequency of bowel movements, duration of bowel movements, and incidence of adverse events between two groups. Results No significant differences were observed in sex, age, or defecation frequency between the two groups. For efficacy, both groups achieved equivalent bowel cleanliness, with a “good preparation” rate of 93.55% and comparable BBPS score of each intestinal segment and total scores. For tolerability, the TCIC-001 group had a shorter medication duration compared to the PEG group ([48.8±25.9] min vs [82.8±28.4] min, P<0.001), a longer defecation duration ([288.6±74.0] min vs [236.5±74.3] min, P<0.001), and a lower incidence of first defecation before medication completion (9.68% vs 41.94%, P=0.004). Regarding safety, no significant differences were observed between the TCIC-001 group and the PEG group in incidences of chloride disturbances (0% vs 9.68%) and calcium disturbances (3.23% vs 6.45%), and no other adverse events. Conclusions TCIC-001 demonstrated comparable bowel-cleansing efficacy to PEG while significantly improving tolerability (reduced medication time and lower risk of premature defecation) and maintaining favorable safety.
2.Endoscopic submucosal dissection of gastrointestinal polyps with a novel plasma radio frequency generator and a disposable mucosal incision knife: A prospective, multicenter, non-inferiority, randomized, controlled clinical trial
Baohui SONG ; Guijun SHI ; Xiaoyue XU ; Jiaxin XU ; Li FENG ; Jianguang XU ; Pinghong ZHOU ; Mingyan CAI
Chinese Journal of Gastrointestinal Surgery 2025;28(4):384-391
Objective:To evaluate the efficacy and safety of a new plasma radiofrequency generator and a disposable mucosal incision knife for endoscopic submucosal dissection (ESD) of gastrointestinal lesions.Methods:This study is a prospective, randomized, non-inferiority multicenter study (Chinese Clinical Trial Registry No.: ChiCTR2000041394). The inclusion criteria for cases are as follows: (1) being able to understand and voluntarily participate in this clinical trial, and voluntarily signing the informed consent form; (2) being 18-70 years old, regardless of gender; (3) having a gastrointestinal lesion and meeting the endoscopic treatment conditions for the indications of endoscopic submucosal dissection (ESD). The exclusion criteria are: (1) meeting the contraindications for ESD; (2) having a surgical contraindication due to coagulation dysfunction or still taking anticoagulants 1 week before surgery; (3) having coagulation dysfunction, that is, the prothrombin time is prolonged by more than 3 seconds (more than 5 seconds in patients with liver disease), or the activated partial thromboplastin time is prolonged by more than 10 seconds, and the platelet count is < 70×10?/L; (4) having severe cardiopulmonary insufficiency and being unable to tolerate the surgery; (5) being a reproductive-aged woman with a positive blood or urine pregnancy test or a lactating woman; (6) the investigator deems that there are other factors that are not suitable for inclusion or affect the subject's participation. Patients who underwent ESD treatment for gastrointestinal lesions from March 2019 to April 2023 at the Endoscopy Center of Zhongshan Hospital Affiliated to Fudan University, the Department of Gastroenterology of Minhang District Central Hospital in Shanghai, and the Department of Gastroenterology of Quzhou People's Hospital were prospectively included. The experimental group used a new plasma radiofrequency therapy instrument and a disposable mucosal incision knife, while the control group used a high-frequency electrosurgical system and a disposable mucosal incision knife. The primary efficacy indicator was the en bloc resection success rate, the secondary efficacy indicators included the coagulation success rate, and the operation stability of the plasma radiofrequency therapy instrument and the disposable mucosal incision knife; the safety indicators included the incidence of intraoperative bleeding, intraoperative perforation, and postoperative complications. Results:The study cohort comprised 194 patients, 95 in the experimental group and 99 in the control group. Analysis of the full set showed rates of en bloc resection of 97.89% (93/95) and 96.97% (96/99) in the experimental and control groups, respectively; the difference being 0.53% (-5.58%, 6.64%). Analysis of the compliance set showed rates of en bloc resection of 97.83% (90/92) and 96.88% (93/96) in the experimental and control groups, respectively; the difference being 0.58% (-5.79%, 6.94%). These data indicate that the rate of en bloc resection in the experimental group using plasma radiofrequency therapy and disposable mucosal incision was not inferior to that of the control group. The rates of achieving intraoperative coagulation in the experimental and control groups were 7.14% (5/70) and 5.97% (4/67), respectively; this difference is not statistically significant ( P=1.000). The control group had a significantly better rate of using the same instruments throughout the procedure than did the experimental group ( P<0.001). In the safety analysis set, the incidences of intraoperative and postoperative adverse events did not differ significantly between the two groups (both P>0.05). Conclusion:Plasma radiofrequency therapy equipment and a disposable mucosal incision knife are safe and effective instruments for performing ESD of gastrointestinal lesions.
3.Applications of artificial intelligence in the diagnosis and treatment of lung cancer
Kunkun GE ; Xin JIN ; Jianguo ZHONG ; Xiaoyue SUN ; Huangsheng XIE ; Sibo PENG ; Jingliang GAN ; Lingling ZU ; Song XU
Chinese Journal of Oncology 2025;47(11):1057-1065
Lung cancer is one of the malignant tumours with the highest morbidity and mortality rates worldwide today, posing a major threat to human health. Accurate diagnosis and standardised treatment play a crucial role in improving the survival rate of lung cancer patients. In recent years, the rapid rise of artificial intelligence (AI) has brought about significant changes in the medical field, providing a new diagnostic and treatment model for lung cancer, and making a series of breakthroughs in lung cancer diagnostic imaging, pathological diagnosis, surgical oncology, radiotherapy, and drug development and treatment. This article introduces the current status of AI application in the field of lung cancer diagnosis and treatment, and extensively discusses the current challenges and future prospects, hoping to provide references and suggestions for future clinical practice.
4.Research progress of nucleic acid aptamer AS1411 in tumor molecular imaging
Wenpeng HUANG ; Xinyao SUN ; Xiaoyue ZHANG ; Qi YANG ; Lele SONG ; Lei KANG
Journal of Chinese Physician 2025;27(4):622-626
Nucleic acid aptamers are a type of single-stranded oligonucleotides screened through in vitro exponentially enriched ligand phylogenetic technology, and they can bind to various targets with high specificity and high affinity. AS1411 is a 26-base guanine-rich DNA aptamer, and its target nucleolin is widely distributed in multiple locations within the cell, including the nucleolus, nucleoplasm, cytoplasm and cell membrane. AS1411 demonstrates multiple advantages, such as weak immunogenicity, low toxicity, easy structural modification, and strong tissue penetration ability. Despite numerous challenges in the clinical transformation process, with the continuous advancement of molecular imaging technology, AS1411 has demonstrated great potential in the fields of targeted imaging and targeted delivery of cancer drugs. This article mainly focuses on the research progress of AS1411 in the field of molecular imaging, covering its applications in magnetic resonance imaging, fluorescence imaging and nuclear medicine imaging, etc.
5.Applications of artificial intelligence in the diagnosis and treatment of lung cancer
Kunkun GE ; Xin JIN ; Jianguo ZHONG ; Xiaoyue SUN ; Huangsheng XIE ; Sibo PENG ; Jingliang GAN ; Lingling ZU ; Song XU
Chinese Journal of Oncology 2025;47(11):1057-1065
Lung cancer is one of the malignant tumours with the highest morbidity and mortality rates worldwide today, posing a major threat to human health. Accurate diagnosis and standardised treatment play a crucial role in improving the survival rate of lung cancer patients. In recent years, the rapid rise of artificial intelligence (AI) has brought about significant changes in the medical field, providing a new diagnostic and treatment model for lung cancer, and making a series of breakthroughs in lung cancer diagnostic imaging, pathological diagnosis, surgical oncology, radiotherapy, and drug development and treatment. This article introduces the current status of AI application in the field of lung cancer diagnosis and treatment, and extensively discusses the current challenges and future prospects, hoping to provide references and suggestions for future clinical practice.
6.Research progress of nucleic acid aptamer AS1411 in tumor molecular imaging
Wenpeng HUANG ; Xinyao SUN ; Xiaoyue ZHANG ; Qi YANG ; Lele SONG ; Lei KANG
Journal of Chinese Physician 2025;27(4):622-626
Nucleic acid aptamers are a type of single-stranded oligonucleotides screened through in vitro exponentially enriched ligand phylogenetic technology, and they can bind to various targets with high specificity and high affinity. AS1411 is a 26-base guanine-rich DNA aptamer, and its target nucleolin is widely distributed in multiple locations within the cell, including the nucleolus, nucleoplasm, cytoplasm and cell membrane. AS1411 demonstrates multiple advantages, such as weak immunogenicity, low toxicity, easy structural modification, and strong tissue penetration ability. Despite numerous challenges in the clinical transformation process, with the continuous advancement of molecular imaging technology, AS1411 has demonstrated great potential in the fields of targeted imaging and targeted delivery of cancer drugs. This article mainly focuses on the research progress of AS1411 in the field of molecular imaging, covering its applications in magnetic resonance imaging, fluorescence imaging and nuclear medicine imaging, etc.
7.Endoscopic submucosal dissection of gastrointestinal polyps with a novel plasma radio frequency generator and a disposable mucosal incision knife: A prospective, multicenter, non-inferiority, randomized, controlled clinical trial
Baohui SONG ; Guijun SHI ; Xiaoyue XU ; Jiaxin XU ; Li FENG ; Jianguang XU ; Pinghong ZHOU ; Mingyan CAI
Chinese Journal of Gastrointestinal Surgery 2025;28(4):384-391
Objective:To evaluate the efficacy and safety of a new plasma radiofrequency generator and a disposable mucosal incision knife for endoscopic submucosal dissection (ESD) of gastrointestinal lesions.Methods:This study is a prospective, randomized, non-inferiority multicenter study (Chinese Clinical Trial Registry No.: ChiCTR2000041394). The inclusion criteria for cases are as follows: (1) being able to understand and voluntarily participate in this clinical trial, and voluntarily signing the informed consent form; (2) being 18-70 years old, regardless of gender; (3) having a gastrointestinal lesion and meeting the endoscopic treatment conditions for the indications of endoscopic submucosal dissection (ESD). The exclusion criteria are: (1) meeting the contraindications for ESD; (2) having a surgical contraindication due to coagulation dysfunction or still taking anticoagulants 1 week before surgery; (3) having coagulation dysfunction, that is, the prothrombin time is prolonged by more than 3 seconds (more than 5 seconds in patients with liver disease), or the activated partial thromboplastin time is prolonged by more than 10 seconds, and the platelet count is < 70×10?/L; (4) having severe cardiopulmonary insufficiency and being unable to tolerate the surgery; (5) being a reproductive-aged woman with a positive blood or urine pregnancy test or a lactating woman; (6) the investigator deems that there are other factors that are not suitable for inclusion or affect the subject's participation. Patients who underwent ESD treatment for gastrointestinal lesions from March 2019 to April 2023 at the Endoscopy Center of Zhongshan Hospital Affiliated to Fudan University, the Department of Gastroenterology of Minhang District Central Hospital in Shanghai, and the Department of Gastroenterology of Quzhou People's Hospital were prospectively included. The experimental group used a new plasma radiofrequency therapy instrument and a disposable mucosal incision knife, while the control group used a high-frequency electrosurgical system and a disposable mucosal incision knife. The primary efficacy indicator was the en bloc resection success rate, the secondary efficacy indicators included the coagulation success rate, and the operation stability of the plasma radiofrequency therapy instrument and the disposable mucosal incision knife; the safety indicators included the incidence of intraoperative bleeding, intraoperative perforation, and postoperative complications. Results:The study cohort comprised 194 patients, 95 in the experimental group and 99 in the control group. Analysis of the full set showed rates of en bloc resection of 97.89% (93/95) and 96.97% (96/99) in the experimental and control groups, respectively; the difference being 0.53% (-5.58%, 6.64%). Analysis of the compliance set showed rates of en bloc resection of 97.83% (90/92) and 96.88% (93/96) in the experimental and control groups, respectively; the difference being 0.58% (-5.79%, 6.94%). These data indicate that the rate of en bloc resection in the experimental group using plasma radiofrequency therapy and disposable mucosal incision was not inferior to that of the control group. The rates of achieving intraoperative coagulation in the experimental and control groups were 7.14% (5/70) and 5.97% (4/67), respectively; this difference is not statistically significant ( P=1.000). The control group had a significantly better rate of using the same instruments throughout the procedure than did the experimental group ( P<0.001). In the safety analysis set, the incidences of intraoperative and postoperative adverse events did not differ significantly between the two groups (both P>0.05). Conclusion:Plasma radiofrequency therapy equipment and a disposable mucosal incision knife are safe and effective instruments for performing ESD of gastrointestinal lesions.
8.Associations of the magnesium depletion score and magnesium intake with diabetes among US adults: an analysis of the National Health and Nutrition Examination Survey 2011-2018
Zhong TIAN ; Shifang QU ; Yana CHEN ; Jiaxin FANG ; Xingxu SONG ; Kai HE ; Kexin JIANG ; Xiaoyue SUN ; Jianyang SHI ; Yuchun TAO ; Lina JIN
Epidemiology and Health 2024;46(1):e2024020-
OBJECTIVES:
The magnesium depletion score (MDS) is considered more reliable than traditional approaches for predicting magnesium deficiency in humans. We explored the associations of MDS and dietary magnesium intake with diabetes.
METHODS:
We obtained data from 18,853 participants in the National Health and Nutrition Examination Survey 2011-2018. Using multivariate regression and stratified analysis, we investigated the relationships of both MDS and magnesium intake with diabetes. To compute prevalence ratios (PRs), we employed modified Poisson or log-binomial regression. We characterized the non-linear association between magnesium intake and diabetes using restricted cubic spline analysis.
RESULTS:
Participants with MDS ≥2 exhibited a PR of 1.26 (95% confidence interval [CI], 1.19 to 1.34) for diabetes. Per-standard deviation (SD) increase in dietary magnesium intake was associated with a lower prevalence of diabetes (PR, 0.91; 95% CI, 0.87 to 0.96). Subgroup analyses revealed a positive association between MDS ≥2 and diabetes across all levels of dietary magnesium intake, including the lowest (PR, 1.35; 95% CI, 1.18 to 1.55), middle (PR, 1.23; 95% CI, 1.12 to 1.35), and highest tertiles (PR, 1.25; 95% CI, 1.13 to 1.37; pinteraction<0.001). Per-SD increase in magnesium intake was associated with lower diabetes prevalence in participants with MDS <2 (PR, 0.92; 95% CI, 0.87 to 0.98) and those with MDS ≥2 (PR, 0.91; 95% CI, 0.84 to 0.98; pinteraction=0.030).
CONCLUSIONS
MDS is associated with diabetes, particularly among individuals with low magnesium intake. Adequate dietary magnesium intake may reduce diabetes risk, especially in those with high MDS.
9.Hydrogen therapy promotes macrophage polarization to the M2 subtype by inhibiting the NF-κB signaling pathway
Xue GAO ; Shiying NIU ; Guohua SONG ; Lulu LI ; Xiaoyue ZHANG ; Wentao PAN ; Xuetao CAO ; Xinhui ZHANG ; Meili SUN ; Guoli ZHAO ; Yueying ZHANG
Chinese Journal of Radiological Health 2024;33(1):33-39
Objective To investigate the role of hydrogen therapy in reducing radiation-induced lung injury and the specific mechanism. Methods Forty C57BL/6 mice were randomly divided into four groups: normal control group, model group, hydrogen therapy group I, and hydrogen therapy group II. A mouse model of radiation-induced lung injury was established. The pathological changes in the lung tissue of the mice were examined with HE staining. Immunofluorescence staining was used to detect the expression of surface markers of M1 and M2 macrophages to observe macrophage polarization. The expression of interleukin (IL)-6, tumor necrosis factor-α (TNF-α), and IL-10 in the lung tissue was measured by immunohistochemistry. The expression of nuclear factor-kappa B (NF-κB) p65 and phosphorylated NF-κB (P-NF-κB) p65 was measured by Western blot. Results HE staining showed that compared with the control group, the model group exhibited alveolar septal swelling and thickening, vascular dilatation and congestion, and inflammatory cell infiltration in the lung tissue; the hydrogen groups had significantly reduced pathological damage and inflammatory response than the model group, with more improvements in hydrogen group II than in hydrogen group I. Immunohistochemical results showed that compared with those in the control group, the levels of the inflammatory cytokines IL-6 and TNF-α were significantly increased in the model group; the hydrogen groups showed significantly decreased IL-6 and TNF-α levels and a significantly increased level of the anti-inflammatory factor IL-10 than the model group, which were more marked in hydrogen group II than in hydrogen group I. Immunofluorescence results showed that compared with the control group, the expression of the surface marker of M1 macrophages in the model group was significantly upregulated; the hydrogen groups showed significantly downregulated M1 marker and significantly upregulated M2 marker, and hydrogen group II showed significantly increased M2 marker compared with hydrogen group I. Western blot results showed that compared with that in the control group, the ratio of P-NF-κB p65/NF-κB p65 in the model group was significantly increased; the P-NF-κB p65/NF-κB p65 ratio was significantly reduced in the hydrogen groups than in the model group, and was significantly lower in hydrogen group II than in hydrogen group I. Conclusion Hydrogen inhalation therapy may reduce the inflammatory response of radiation-induced lung injury by inhibiting the NF-κB signaling pathway to promote the polarization of the macrophage M1 subtype to the M2 subtype.
10.Correlation between serum HbA1c,LAG-3 and thyroid nodules in patients with type 2 diabetes mellitus
Xiaoyue YANG ; Honghong SONG ; Shaozhen HU ; Ying PAN ; Xiaoxue BAO ; Wenying YAN
International Journal of Laboratory Medicine 2024;45(2):160-164
Objective To explore the correlation between serum glycosylated hemoglobin(HbA1c),lym-phocyte activation gene-3(LAG-3)and thyroid nodules in patients with type 2 diabetes mellitus(T2DM).Methods A total of 120 T2DM patients with thyroid nodules admitted to the Third Hospital of Hebei Medi-cal University from July 2021 to July 2022 were included as the study group,and 100 simple T2DM patients(without thyroid nodules)were included as the control group during the same period.According to the patho-logical examination results of thyroid nodules,the study group was grouped into a benign nodule group(85 ca-ses)and a malignant nodule group(35 cases).Enzyme linked immunosorbent assay was applied to detect the serum LAG-3 level of all study subjects.Fully automated glycated hemoglobin analyzer was applied to detect HbA1c level in all study subjects.Spearman method was applied to analyze the correlation between serum HbA1c,LAG-3,and thyroid imaging report and data system(TI-RADS)scores in patients with T2DM and thyroid nodules.Multivariate Logistic regression was applied to analyze the influencing factors of T2DM with thyroid nodules.Receiver operating characteristic(ROC)curve was applied to analyze the diagnostic value of HbA1c and LAG-3 levels in T2DM with thyroid nodules.Results Compared with the control group,the level of HbA1c in the study group was obviously higher(P<0.05),while the level of LAG-3 was obviously lower(P<0.05).Compared with the benign nodule group,the serum LAG-3 level in the malignant nodule group was obviously lower(P<0.05),while the level of LAG-3 was obviously lower(P<0.05).Spearman analysis showed a positive correlation between HbA1c level and TI-RADS score in T2DM patients with thyroid nod-ules(r=0.378,P<0.001),while the serum LAG-3 level was negatively correlated with TI-RADS score(r=-0.472,P<0.001).The results of multivariate Logistic regression analysis showed that HbA1c was a risk factor for the occurrence of thyroid nodules in T2DM patients(P<0.05),and LAG-3 was a protective factor for the occurrence of thyroid nodules in T2DM patients(P<0.05).The combination of HbA1c and LAG-3 in the diagnosis of T2DM with thyroid nodules was superior to their individual diagnosis(Zcombination-HbA1c=2.542,P=0.011;Zcombination-LAG-3=3.098,P=0.002).Conclusion Patients with T2DM combined with thyroid nodules have obviously lower serum LAG-3 level and higher HbA1c level,and the two are related to the malignancy of thyroid nodules.

Result Analysis