1.Meta-analysis of the efficacy and safety total glucosides of paeonia in the treatment of systemic lupus erythematosus
Xiangyan HAO ; Jiahui LENG ; Zhengqi LIU ; Xinchang WANG ; Cong HUANG ; Xiaopeng LI ; Yi LING
China Pharmacy 2026;37(2):232-237
OBJECTIVE To evaluate the efficacy and safety of total glucosides of paeonia (TGP) in the treatment of systemic lupus erythematosus (SLE). METHODS Randomized controlled trial (RCT) about TGP combined with western medicine versus western medicine alone for SLE treatment were retrieved from PubMed, Embase, Cochrane Library, Web of Science, CNKI, VIP, Wanfang Data, and CBM. The search period spanned from the inception of each database to June 1, 2025. After literature screening, data extraction, and quality assessment of the included studies, Meta-analysis was performed using RevMan 5.4 software. RESULTS Fifteen RCTs, involving 1 318 patients, were included. Meta-analysis results showed that compared with western medicine alone, TGP combined with western medicine significantly improved clinical efficacy [OR=4.96, 95%CI(3.41, 7.23), P<0.000 01], complement 3 [MD=0.18, 95%CI (0.13, 0.23), P<0.000 01] and complement 4[MD=0.08, 般021) 95%CI (0.04, 0.11), P<0.000 01], and reduced the levels of immunoglobulin G (IgG) [MD=-3.10, 95%CI (-3.59,-2.62), P<0.000 01], IgA [MD=-0.68, 95%CI (-0.78, -0.58), P<0.000 01], IgM [MD=-0.43, 95%CI (-0.53,-0.34), P<0.000 01], systemic lupus erythematosus disease activity index (SLEDAI) [MD=-1.59, 95%CI (-2.20, -0.99), P<0.000 01], recurrence rate [OR=0.23, 95%CI (0.13, 0.42), P<0.000 01] and the incidence of adverse drug reactions [OR= 0.54, 95%CI (0.36, 0.82), P=0.004]. CONCLUSIONS TGP therapy can improve clinical efficacy of SLE patients, promote the restoration of immunoglobulins and complements, reduce SLEDAI and recurrence rate and has good safety.
2.Proteomics combined with bioinformatics analysis of protein markers of dry eye
Yanting YANG ; Yajun SHI ; Guang YANG ; Haiyang JI ; Jie LIU ; Jue HONG ; Dan ZHANG ; Xiaopeng MA
International Eye Science 2025;25(1):104-111
AIM:To analyze differential proteins associated with the pathogenesis of dry eye(DE)using bioinformatics methods, in order to reveal their potential molecular mechanisms.METHODS: Articles published in PubMed and EMBASE databases from the inception of the database to August 31, 2023, that used proteomic methods to detect protein expression in clinical samples of dry eye were searched. Differential proteins were selected and further analyzed using the STRING database and Cytoscape software for hub gene screening and module analysis. Protein-protein interaction(PPI)analysis, gene ontology(GO)functional annotation, and Kyoto encyclopedia of genes and genomes(KEGG)pathway enrichment analysis were performed.RESULTS: A total of 21 articles were included, identifying 74 differentially expressed proteins. The most frequently occurring differential proteins were calgranulin A(SA1008), lipocalin-1(LCN1), lysozyme C(LYZ), mammaglobin-B(SCGB2A1), proline-rich protein 4(PRR4), transferrin(TF), and calgranulinB(S100A9). The top 10 hub genes were serum albumin(ALB), tumor necrosis factor(TNF), interleukin 6(IL6), IL1B, IL8, matrix metalloproteinase 9(MMP9), alpha-1-antitrypsin(SERPINA1), IL10, complement component 3(C3), and lactotransferrin(LTF). Module analysis suggested MMP9 and PRR4 as seed genes. KEGG analysis showed that differential proteins were mainly enriched in the IL17 signaling pathway(61.9%).CONCLUSION: The results reveal potential molecular targets and pathways for DE and confirm the association between the pathogenesis of DE and inflammation. Further in-depth research is needed to confirm the significance of these biomarkers in clinical practice.
3.Distribution of gamma pass rates for ultra-long target volumes of cervical cancer based on two measurement methods
Junjie LEI ; Jiren LIU ; Xiaopeng PAN ; Xu HOU ; Xiaoli JIN
Chinese Journal of Radiological Medicine and Protection 2025;45(9):870-875
Objective:To compare gamma pass rates for ultra-long target volumes of cervical cancer between individual measurements by moving the phantom isocenter and segmented measurements combined with merging and to assess the influence of scattering blocks on verification result during segmented measurements.Methods:A retrospective study was conducted on 24 cervical cancer patients with ultra-long target volumes (lengths: 23.5–36.0 cm) treated using helical tomotherapy. Two measurement methods were used to verify the gamma pass rates: individual measurements by moving the phantom isocenter and segmented measurements combined with merging. For the first measurement method, the patients′ treatment plans were transferred to the ArcCheck phantom. After the dose distribution was calculated and exported, the gamma pass rates measured and calculated were compared. For the segmented measurements, a 50-cm-long virtual phantom was imported, and the treatment plans of patients were then transferred to the virtual phantom. Afterward, the dose distribution of the virtual phantom was calculated and exported. Then, two dose measurements were conducted under upward and downward setup of the ArcCheck phantom. Two dose measurement files were obtained and then fused to produce a merged file. Then, the γ pass rates were calculated. Repeated measurements were conducted after scattering blocks were installed. The γ-pass rates were assessed using varying dose criteria.Results:Under various evaluation criteria, no statistically significant differences in γ pass rates were observed between the individual measurements by moving the phantom isocenter and the segmented measurement in the presence of scattering blocks ( P > 0.05). In contrast, there existed statistically significant differences in γ pass rates between the individual measurements by moving the phantom isocenter and the segmented measurement in the absence of scattering blocks according to the (global) criterion of 3%/2 mm absolute dose ( Z = -2.31, P = 0.02). Additionally, the segmented measurement in the presence of scattering blocks enhanced pass rates, with statistical significant difference under the criterion of 3%/2 mm relative dose ( Z = -2.11, P = 0.04). Conclusions:In the case where ArcCheck is used to measure the dose distribution of ultra-long target volumes in cervical cancer, it is advisable to preferentially use individual measurements by moving the phantom isocenter. When segmented measurements combined with merging are required, it is necessary to install scattering blocks during measurements. This will improve γ-pass rates during verification and ensure the accuracy of dose verification.
4.Correlation analysis between FO with spiral CT measurement and prognosis of percutaneous-assisted superior capsulotomy approach for THA
Changzeng LIU ; Jianjie MAO ; Cong CHEN ; Xiaopeng LI ; Hui CHU
China Medical Equipment 2025;22(10):61-65
Objective:To explore the clinical application value of the measured femoral offset(FO)based on three-dimensional modeling of spiral computed tomography(CT)in percutaneous-assisted superior capsulotomy approach for total hip arthroplasty(THA).Methods:A total of 92 patients with fractures at hip joint who underwent percutaneous-assisted superior capsulotomy approach for THA at the 904th Hospital of People's Liberation Army Joint Service Support Force between January 2023 and June 2024 were prospectively enrolled.According to the preoperative FO median(34.8 mm)that was measured by CT,these patients were divided into high-FO group(n=46)and low-FO group(n=46).Postoperative outcomes between two groups,which included bone density T value(T value),FO value,external tilt angle and forward tilt angle of mortar cup,and the deviation of femoral stem alignment,as well as the scores of Harris Hip Score(HHS),Visual Analog Scale(VAS),positive rate of Trendelenburg sign and incidence of complication,were compared.Results:The preoperative bone density T value of high-FO group was(-1.1±0.7),which was higher than(-1.3±0.8)of low-FO group,and the difference was not significant(P>0.05).The FO was(38.5±3.4)mm in high-FO group,which was lower than(30.9±2.7)in low-FO group,and the difference was significant(t=12.356,P<0.001).The external tilt angle and forward tilt angle of mortar cup,and the deviation of femoral stem alignment of high-FO group were respectively(42.6±3.9)°,(16.8±2.6)° and(1.1±0.7)mm,which were lower than(43.4±4.1)°,(17.5±3.0)° and(1.3±0.8)mm of low-FO group,and the differences were not significant(P>0.05).The HHS scores at the 1st,3rd,6th and 12th month after surgery in high-FO group were significantly better than those of low-FO group,and the differences were significant(t=3.104,4.772,6.358,7.326,P<0.05).The VAS scores at the 3rd and 12th month after surgery in high-FO group were significantly lower than those in low-FO group,and the difference was significant(t=-9.215,-7.582,P<0.05).The positive rate of Trendelenburg sign at the 1st month after surgery in high-FO group was 15.2%(7/46),which was significantly lower than 39.1%(18/46)in low-FO group,and the difference was significant(x2=7.324,P<0.05).The used time of walking aids was shortened by 37%[(13.5±3.1)d]in high-FO group,which was significantly shorter than[(21.4±4.9)d]in low-FO group,and the difference was significant(t=9.127,P<0.05).Conclusion:Spiral CT-guided FO precision reconstruction can significantly enhance postoperative recovery quality of joint function of patients who undergo percutaneous-assisted superior capsulotomy approach for THA,and reduce the risks of abnormal gait and dislocation.
5.A Comparative Study of Digital 3D Technology Assisted Versus Traditional One-hole Split Endoscopic Surgery for Lumbar Spinal Stenosis With Degenerative Scoliosis
Weiliang SU ; Min ZHANG ; Guohua DAI ; Kuishuai XU ; Dawei WANG ; Xiaopeng GENG ; Dong LIU ; Yongfeng DOU
Chinese Journal of Minimally Invasive Surgery 2025;25(10):615-622
Objective To compare the clinical efficacy of digital 3D technology assisted and traditional one-hole split endoscopic surgery for lumbar spinal stenosis with degenerative scoliosis(LSS-DS).Methods Clinical data of 42 patients with LSS-DS who underwent one-hole split endoscopic surgery from January 2022 to December 2023 were retrospectively analyzed.Among them,20 cases were treated with digital 3D technology assisted one-hole split endoscopic surgery(3D group),and 22 cases were treated with traditional one-hole split endoscopic surgery(traditional group).The operation time,intraoperative blood loss,lateral articular surface preservation rate,Visual Analogue Scale(VAS)of lower extremity pain,Oswestry Disability Index(ODI)and modified MacNab criteria at the last follow-up were compared between the two groups.Results Both groups of patients were operated successfully.The operation time of the 3D group and the traditional group was(73.3±24.0)min and(65.7±23.8)min,respectively,with no significant difference(t=1.020,P=0.314).The intraoperative blood loss was(65.3±14.7)ml and(66.7±17.1)ml,respectively,with no significant difference(t=-0.298,P=0.767).The retention rate of lateral articular surface in the 3D group[(88.2±6.3)%]was significantly higher than that in the traditional group[(82.7±4.6)%,t=3.201,P=0.003].One patient in the traditional group had dural tear and was cured after conservative treatment.There were 3 cases of calf muscle venous thrombosis in the 3D group and 4 cases in the traditional group.All the 7 patients were given anticoagulant therapy and appropriately delayed time of ambulation.In the3D group,20 cases were followed up for6-13 months,with a mean of(8.2±2.0)months;in the traditional group,22 cases were followed up for 6-12 months,with a mean of(7.7±1.7)months.According to the modified MacNab criteria,the excellent and good rate was 95.0%(19/20)in the 3D group and 90.1%(20/22)in the traditional group at the last follow-up,and there was no significant difference between the two groups(Z=-0.311,P=0.756).The VAS score and ODI of the two groups were significantly improved at 3 months and 6 months after operation(all P=0.000),but there was no significant difference between the two groups at each time point(P>0.05).Conclusion The short-term efficacy of digital 3D technology assisted one-hole split endoscopic surgery in the treatment of LSS-DS is definite,and the symptoms of patients are significantly improved.
6.Application of dual-energy computed tomography imaging for evaluation of bone repair
Danyang SU ; Yuanbo MA ; Jinlong LIU ; Haoran ZHANG ; Shenyu YANG ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
Chinese Journal of Comparative Medicine 2025;35(1):155-162
Bone defect repair is an urgent problem in the field of orthopedics,and numerous researchers are working to develop more effective treatment plans.The accurate evaluation of bone repair after surgery is a crucial step.In line with the development of computed tomography(CT)imaging,dual-energy CT imaging has shown significant advantages in analyzing bone composition and reducing metal artifacts.This article reviews the application of dual-energy CT imaging for the evaluation of bone repair in animals.
7.Construction of a Nomogram risk prediction model for deep vein thrombosis in patients with knee osteoarthritis after artificial total knee arthroplasty
Peng LIU ; Xiaopeng WANG ; Linfeng HU
Journal of Shenyang Medical College 2025;27(1):55-60
Objective:To investigate the factors influencing the occurrence of deep vein thrombosis(DVT)in patients with knee osteoarthritis after artificial total knee arthroplasty(TKA)and to construct a nomogram prediction model.Methods:A total of 120 patients with knee osteoarthritis underwent TKA from Dec 2020 to Dec 2022 were selected.The patients were divided into DVT group(n=20)and non-DVT group(n=100)according to whether DVT occurred after surgery.Receiver operating characteristic(ROC)curve was used to analyze the predictive value of each influencing factor to the occurrence of DVT.Multivariable logistic regression was used to analyze the factors affecting the occurrence of DVT.The nomogram prediction model of DVT was constructed by the R software 4.0"rms"package.The calibration and decision curves were used to internally validate and clinically assess the predictive efficacy of the nomogram prediction model.Results:There were significant differences between DVT group and non-DVT group in age,body mass index(BMI),diabetes mellitus,hyperlipidaemia,plasma D-dimer level,operative time,intraoperative haemorrhage,post-operative bedrest,and anaesthesia modality(P<0.05).ROC curve showed that the AUC for age,BMI,plasma D-dimer,operative time,intraoperative haemorrhage,and postoperative bedrest were 0.663,0.678,0.985,0.856,0.925 and 0.925,respectively.Multivariable logistic regression analysis showed that age≥71 years old,BMI≥25.47 kg/m2,diabetes mellitus,hyperlipidaemia,plasma D-dimer level≥0.69 mg/L,and general anaesthesia were independent risk factors for postoperative DVT(P<0.05).The calibration curve of the nomogram prediction model was close to the original and ideal curves,with a C-index of 0.813(0.721-0.905),indicating a high degree of fit.The threshold value of the nomogram prediction model was>0.17,which could provide a net clinical benefit.And its net clinical benefit was higher than age,BMI,diabetes mellitus,hyperlipidemia,plasma D-dimer,and anaesthesia mode.Conclusions:The factors affecting the occurrence of DVT in patients with knee osteoarthritis after TKA are age,BMI,diabetes mellitus,hyperlipidaemia,plasma D-dimer level,operative time,intraoperative haemorrhage,postoperative bedtrest,and anaesthesia mode.The personalized neomorph prediction model constructed by these predictive factors can help to predict and evaluate whether DVT will be occurred in patients with knee osteoarthritis after TKA,so as to intervene early,reduce the incidence and improve the prognosis.
8.Preparation of vancomycin hydrochloride-loaded polydopamine nanoparticles and their antimicrobial effect in combination with photothermal therapy
Lihua PAN ; Bin LIU ; Xiayun JIANG ; Xiaopeng ZHOU
China Pharmacy 2025;36(15):1887-1892
OBJECTIVE To prepare vancomycin hydrochloride(VH)-loaded polydopamine(PDA)nanoparticles(VH@PDA nanoparticles),and study their antimicrobial effect in combination with photothermal therapy.METHODS Using PDA as the carrier,VH was loaded to prepare VH@PDA nanoparticles(PDA nanoparticles were prepared using the same method).The nanoparticles were characterized with laser particle size analyzer,transmission electron microscope,and UV visible absorption spectrometer;the drug loading capacity and encapsulation efficiency of the nanoparticles were determined.The near-infrared laser irradiation was adopted to determine their photothermal ability.Taking Staphylococcus aureus as the research object,the bactericidal properties of the nanoparticles in combination with photothermal therapy in vitro were clarified through plate colony coating method,live/dead staining analysis,crystal violet staining.Using L929 cells as the research object,the effects of VH@PDA nanoparticles at different mass concentrations(0,3.125,6.25,12.5,25,50 and 100 μg/mL)on cell viability were investigated to assess their biocompatibility.RESULTS VH@PDA nanoparticles were successfully loaded with VH,exhibiting uniform particle size(approximately 300 nm),distinct pore size,and a spherical structure.The drug loading capacity was 11.34%,the encapsulation efficiency was 32.00%,the photothermal conversion efficiency reached 23.55%,and they demonstrated stable photothermal performance.The antibacterial effect results of the combined photothermal therapy demonstrated that without near-infrared laser irradiation,the antibacterial effects of VH,PDA nanoparticles,and VH@PDA nanoparticles were not significant.However,when subjected to near-infrared laser irradiation,VH@PDA nanoparticles exhibited a pronounced antibacterial effect.The results of the cell experiments revealed that after treatment with VH@PDA nanoparticles at various mass concentrations,the cell viability rates remained above 80%.CONCLUSIONS VH@PDA nanoparticles are successfully prepared,which exhibit stable photothermal properties,significant antibacterial effects when combined with photothermal therapy,and good biocompatibility.
9.Effect of the thicknesses of different reconstruction layer and the ROI thicknesses on the measurement of BMD value of QCT
Jinlong LIU ; Danyang SU ; Haoran ZHANG ; Yuanbo MA ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
China Medical Equipment 2025;22(1):19-23
Objective:To assess the effect of using different thicknesses of reconstruction layer and different thicknesses of region of interest (ROI) on the results of vertebral bone mineral density (BMD) values that were measured by quantitative computed tomography (QCT). Methods:A total of 100 patients who underwent QCT screening for opportunistic osteoporosis between May and September 2021 at the First Affiliated Hospital of Zhengzhou University were retrospectively collected. Images that the thicknesses of QCT reconstruction layer were respectively 1 and 5 mm were transferred to the QCT Pro workstation,and ROI thicknesses were adjusted to 5,7,and 9 mm,respectively. The average BMD values of QCT measurements were recorded under different thicknesses of reconstruction layer and different ROI thicknesses. Then,the effects of the choose of different thicknesses of reconstruction layer and the different ROI thicknesses on BMD values that were measured by QCT were analyzed. Results:The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (117.41±45.97) mg/cm3 and (118.77±44.84) mg/cm3 when ROI thickness was 5 mm,with a statistically significant difference (t=-2.283,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.38±46.06) mg/cm3 and (119.06±44.55) mg/cm3 when the ROI thickness was 7mm,and the difference was statistically significant (t=-3.280,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.25±45.36) mg/cm3 and (120.12±44.10) mg/cm3 when the ROI thickness was 9 mm,and the difference was statistically significant (t=-5.841,P<0.001). The differences in BMD measurement values among 5,7 and 9 mm ROI thicknesses were not statistically significant when the thicknesses of reconstruction layer were respectively 1 and 5 mm. Conclusion:There is an effect of the thickness of QCT reconstruction layer on average BMD measurement values,and 1 mm thickness of reconstruction layer is more suitable to clinical application,while there is not significant effect in ROI thickness on average BMD measurement value of QCT. In clinical application,it is feasible to adjust ROI thickness according to actual situation so as to avoid the effect caused by some factors such as fracture or vertebral implants.
10.Effect of the thicknesses of different reconstruction layer and the ROI thicknesses on the measurement of BMD value of QCT
Jinlong LIU ; Danyang SU ; Haoran ZHANG ; Yuanbo MA ; Qiuju MIAO ; Zhen BAI ; Xiaopeng YANG
China Medical Equipment 2025;22(1):19-23
Objective:To assess the effect of using different thicknesses of reconstruction layer and different thicknesses of region of interest (ROI) on the results of vertebral bone mineral density (BMD) values that were measured by quantitative computed tomography (QCT). Methods:A total of 100 patients who underwent QCT screening for opportunistic osteoporosis between May and September 2021 at the First Affiliated Hospital of Zhengzhou University were retrospectively collected. Images that the thicknesses of QCT reconstruction layer were respectively 1 and 5 mm were transferred to the QCT Pro workstation,and ROI thicknesses were adjusted to 5,7,and 9 mm,respectively. The average BMD values of QCT measurements were recorded under different thicknesses of reconstruction layer and different ROI thicknesses. Then,the effects of the choose of different thicknesses of reconstruction layer and the different ROI thicknesses on BMD values that were measured by QCT were analyzed. Results:The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (117.41±45.97) mg/cm3 and (118.77±44.84) mg/cm3 when ROI thickness was 5 mm,with a statistically significant difference (t=-2.283,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.38±46.06) mg/cm3 and (119.06±44.55) mg/cm3 when the ROI thickness was 7mm,and the difference was statistically significant (t=-3.280,P<0.05). The average BMD values of 1 mm and 5 mm thicknesses of reconstruction layer were respectively (116.25±45.36) mg/cm3 and (120.12±44.10) mg/cm3 when the ROI thickness was 9 mm,and the difference was statistically significant (t=-5.841,P<0.001). The differences in BMD measurement values among 5,7 and 9 mm ROI thicknesses were not statistically significant when the thicknesses of reconstruction layer were respectively 1 and 5 mm. Conclusion:There is an effect of the thickness of QCT reconstruction layer on average BMD measurement values,and 1 mm thickness of reconstruction layer is more suitable to clinical application,while there is not significant effect in ROI thickness on average BMD measurement value of QCT. In clinical application,it is feasible to adjust ROI thickness according to actual situation so as to avoid the effect caused by some factors such as fracture or vertebral implants.

Result Analysis
Print
Save
E-mail