1.Biomechanical characteristics of a novel sacroiliac lag screw
Cheng LIANG ; Chuanchuan ZHUO ; Xiaogang ZHANG ; Guan WANG ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO ; Zhongmin JIN
Chinese Journal of Tissue Engineering Research 2025;29(33):7080-7086
BACKGROUND:The pelvis has abundant trabecular bone content,but the ability of conventional sacroiliac percutaneous fixation to control trabecular bone is limited,leading to fixation failure.Therefore,the development of devices that can more effectively control trabecular bone tension is of significant importance.OBJECTIVE:The mechanical properties of a novel sacroiliac tension screw were investigated using biomechanical testing and numerical modeling analysis,along with an assessment of the reliability of the pull-out force numerical model.METHODS:A mechanical model was established based on the working principle of the novel sacroiliac tension screw.Numerical methods were employed to analyze its pull-out performance,validated through mechanical testing with polyurethane material to assess the reliability of the pull-out force numerical model.Using pelvic specimens,the mechanical effectiveness of the novel sacroiliac tension screw in repairing sacroiliac joint injuries was analyzed under normal standing posture,along with an evaluation of the load stiffness of different pelvic models in the standing position.RESULTS AND CONCLUSION:(1)The average error between the computed values of the numerical model and the measured values was 13.19%,indicating a certain level of validity for the numerical model.(2)The damage to the polyurethane material after the extraction of the screw was less pronounced in the novel screw group.(3)The average effective holding displacement for the novel screw was approximately(9.24±0.27)mm,significantly greater than the average displacement of(1.71±0.57)mm observed with the lag screws.However,the maximum resistance to pullout for the lag screws was significantly higher than that for the novel screws.(4)The novel screw effectively repaired sacroiliac joint injuries.(5)The stiffness after repair of sacroiliac joint injuries was equivalent when using a single novel screw compared to using two lag screws.(6)These results prove that the theoretical model for the maximum resistance to pullout of the screws established in this study has a certain level of validity and can guide the design of them with improved mechanical performance.The novel sacroiliac spiral blade screw can effectively hold trabecular bone and has practical clinical utility.
2.Biomechanical characteristics of a novel sacroiliac lag screw
Cheng LIANG ; Chuanchuan ZHUO ; Xiaogang ZHANG ; Guan WANG ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO ; Zhongmin JIN
Chinese Journal of Tissue Engineering Research 2025;29(33):7080-7086
BACKGROUND:The pelvis has abundant trabecular bone content,but the ability of conventional sacroiliac percutaneous fixation to control trabecular bone is limited,leading to fixation failure.Therefore,the development of devices that can more effectively control trabecular bone tension is of significant importance.OBJECTIVE:The mechanical properties of a novel sacroiliac tension screw were investigated using biomechanical testing and numerical modeling analysis,along with an assessment of the reliability of the pull-out force numerical model.METHODS:A mechanical model was established based on the working principle of the novel sacroiliac tension screw.Numerical methods were employed to analyze its pull-out performance,validated through mechanical testing with polyurethane material to assess the reliability of the pull-out force numerical model.Using pelvic specimens,the mechanical effectiveness of the novel sacroiliac tension screw in repairing sacroiliac joint injuries was analyzed under normal standing posture,along with an evaluation of the load stiffness of different pelvic models in the standing position.RESULTS AND CONCLUSION:(1)The average error between the computed values of the numerical model and the measured values was 13.19%,indicating a certain level of validity for the numerical model.(2)The damage to the polyurethane material after the extraction of the screw was less pronounced in the novel screw group.(3)The average effective holding displacement for the novel screw was approximately(9.24±0.27)mm,significantly greater than the average displacement of(1.71±0.57)mm observed with the lag screws.However,the maximum resistance to pullout for the lag screws was significantly higher than that for the novel screws.(4)The novel screw effectively repaired sacroiliac joint injuries.(5)The stiffness after repair of sacroiliac joint injuries was equivalent when using a single novel screw compared to using two lag screws.(6)These results prove that the theoretical model for the maximum resistance to pullout of the screws established in this study has a certain level of validity and can guide the design of them with improved mechanical performance.The novel sacroiliac spiral blade screw can effectively hold trabecular bone and has practical clinical utility.
3.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
4.Survey on the awareness and clinical application of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians
Yuanyuan KONG ; Yujie GUO ; Yujuan GUAN ; Xuan LIANG ; Zhongjie HU ; Xiaobo LU ; Mingqin LU ; Yongfeng YANG ; Meifang HAN ; Hong YOU ; Zhiyun YANG ; Jidong JIA
Journal of Clinical Hepatology 2025;41(6):1068-1074
ObjectiveTo investigate the awareness and clinical practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. MethodsFrom July 19 to December 31, 2024, a self-designed electronic questionnaire was distributed via the WeChat mini program to collect related data from 1 588 clinicians nationwide, including their awareness and practice based on 18 questions regarding testing and referral, diagnosis and treatment, and follow-up. ResultsAmong all respondents, only 350 clinicians correctly understood all the updated key points of antiviral indications and treatment for special populations in the 2022 edition of guidelines for the prevention and treatment of chronic hepatitis B, with an overall awareness rate of 22.0%. Only 20% — 40% of the patients with positive HBV DNA and an age of >30 years receive antiviral therapy, while 80% — 100% of the patients with positive HBV DNA and a family history of hepatitis B cirrhosis or hepatocellular carcinoma receive antiviral therapy. The median follow-up rates at 1 year, 3 years, and 5 years were 67.5% 57.5% and 47.5%,respectively, showing a trend of gradual reduction, which might be associated with the influencing factors such as insufficient time for follow-up management by clinicians, insufficient awareness of the disease among patients, and poor adherence to follow-up. ConclusionThere is a gap between the awareness and practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. It is recommended to further strengthen training and focus on the whole process of “detection, diagnosis, treatment, and management” for patients with chronic hepatitis B in healthcare institutions, in order to promote the implementation of the guidelines.
5.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
6.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
7.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
8.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.
9.Mechanics Analysis on Novel Micro-Movement Elastic Implant of Distal Tibiofibular Syndesmosis in Dorsiflexion Position
Cheng LIANG ; Chunyan LI ; Hanwen ZHANG ; Jianqiang XUE ; Ke DUAN ; Guan WANG ; Xiaobo LU
Journal of Medical Biomechanics 2022;37(2):E256-E261
Objective To study mechanical properties of the novel micro-movement elastic implant of distal tibiofibular syndesmosis in dorsiflexion position.Methods A combination of simulation and experiment was used. The normal ankle dorsiflexion model, the bone nail repaired model and the micro-movement elastic implant repaired model were established by using Mimics and CT data. Besides, ANSYS Workbench was used for finite element analysis. Mechanical experiments on lower limb specimens were conducted on Instron E10000 mechanical test instrument, and five sets of experimental data were measured and analyzed.Results Mechanical properties of the micro-movement elastic implant repaired model were closer to those of the normal ankle dorsiflexion model, but stress of the micro-movement elastic implant repaired mode was greater than that of the bone nail repaired model. The results of two-sample heteroscedasticity t test indicated that there was no significant difference in resistance torque between the micro-movement elastic implant repaired model and the normal ankle dorsiflexion model.Conclusions For dorsiflexion position, repairing mechanical properties of the novel micro-movement elastic implant are much better than those of the bone nail, and there is still room for optimizing the micro-movement elastic implant.
10.Mechanical Properties of Novel Interlocking Intramedullary Nail for Fixing Transverse Olecranon Fractures
Xiaoshuai QIN ; Yun GAO ; Guan WANG ; Yulin XU ; Jinui LIU ; Jianhua GE ; Ke DUAN ; Xiaobo LU ; Cheng LIANG
Journal of Medical Biomechanics 2022;37(4):E618-E623
Objective To study the effect of interlocking intramedullary nail on fixing transverse olecranon fracture. Methods Nine pairs of fresh ulna specimens were collected and the transverse fracture model of olecranon was established. Kirschner wire tension band and interlocking intramedullary nail were used to repair the fracture. Cyclic dynamic tension loads with amplitude of 25 N, mean value of 45 N and frequency of 05 Hz were applied to the triceps tendon under simulated elbow flexion conditions of 30°, 45° and 60°, respectively. The fracture displacements of specimens within 300 cycles were recorded in three groups. ResultsAt 30° flexion angle, the fracture displacement of interlocking intramedullary nail group and Kirschner wire tension band group was (1.831±0.333) mm and (3.723±2.390) mm, respectively. At 45° flexion angle, the fracture displacement of interlocking intramedullary nail group and Kirschner wire tension band group was (1.167±0.374) mm and (2.455±0.609) mm, respectively. At 60° flexion angle, the fracture displacement of interlocking intramedullary nail group and Kirschner wire tension band group was (1.407±0.342) mm and (3.112±1.025) mm, respectively. The fracture displacement of interlocking intramedullary nail was smaller. Conclusions The mechanical properties of interlocking intramedullary nail are better than those of Kirschner wire tension band, and the interlocking intramedullary nail is more stable and firmer for fixing transverse olecranon fracture. Moreover, the interlocking intramedullary nail is installed with the operating tool, thus the operation is more accurate and faster, and the operation efficiency is greatly improved.

Result Analysis