1.Analysis of Microbiological and Parasitic Testing Results for Laboratory Animals in Jiangxi Province, 2020-2024
Fangping XIAO ; Lijuan XIONG ; Bo JIA ; Huan LIU ; Yongbing LUO ; Xiaorong WAN
Laboratory Animal and Comparative Medicine 2026;46(1):119-126
Objective To assess the current status of microbial and parasitic quality control for laboratory animals in Jiangxi Province by analyzing microbiological and parasitic test results from production facilities between 2020 and 2024, and to provide a basis for enhancing quality control measures. MethodsIn accordance with the current national standards for laboratory animals at the time of testing, the Jiangxi Provincial Laboratory Animal Quality Inspection Station (affiliated to Institute of Occupational Medicine of Jiangxi) conducted microbial and parasitic testing on 451 laboratory animals of 4 species from 6 laboratory animal production units in Jiangxi Province between 2020 and 2024, and analyzed the quality status of laboratory animals in the province. ResultsPasteurella pneumotropica was detected in one mouse sample in 2020, with a detection rate of 5.00%. Pseudomonas aeruginosa was detected in one mouse sample and mouse hepatitis virus antibody was detected in another mouse sample in 2023, with a detection rate of 2.78%, respectively. No microorganisms or parasites that should be excluded from SPF grade mice as specified in the national standards were detected in 2021, 2022, or 2024, with a qualification rate of 100.00%. Pasteurella pneumotropica was detected in four rat samples in 2020, with a detection rate of 20.00%. Pseudomonas aeruginosa was detected in two rat samples in 2021, with a detection rate of 10.00%, and Tyzzer's disease agent antibody was detected in four rat samples in 2024, with a detection rate of 10.00%. No microorganisms or parasites that should be excluded from SPF grade rats as specified in the national standards were detected in 2022 or 2023, with a qualification rate of 100.00%. For rabbits and guinea pigs, no microorganisms or parasites required to be tested for conventional grade rabbits and guinea pigs as specified in the national standards were detected from 2020 to 2024, with the qualification rate of both species reaching 100.00%. ConclusionBased on the microbial and parasitic testing results, the quality of rabbits and guinea pigs in Jiangxi Province is satisfactory. However, some issues persist with rats and mice. It is recommended to enhance the quality of experimental animals in Jiangxi Province by increasing the frequency of random inspections by quality testing units or by improving the self-inspection capabilities of production and user facilities.
2.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
3.Investigation of natural radionuclide activity in drinking water in Hohhot, China
Bo JU ; Yulong BAO ; Shuai ZHANG ; Xiang LIU ; Xiao XU ; Zhichao SUN ; Xiaojuan YANG
Chinese Journal of Radiological Health 2026;35(2):159-164
Objective To investigate the activity concentrations of natural radionuclides in drinking water (tap water and well water) in urban and rural areas of Hohhot, assess the safety of drinking water, and to provide data support for local drinking water radioactivity monitoring and management. Methods Representative samples of well water and tap water were collected from nine banners/counties/districts in Hohhot. Activity concentrations were measured using a low-background gross α/β counter, an α spectrometer, inductively coupled plasma mass spectrometry, and a radium/radon analyzer. Results A total of nine tap water samples and nine well water samples were analyzed. For the tap water samples, gross α activity concentrations ranged from 0.093 to 0.193 Bq/L, gross β from 0.091 to 0.225 Bq/L, uranium mass concentrations from 2.32 to 10.36 μg/L, thorium mass concentrations from 0.09 to 0.20 μg/L,210Po activity concentrations from below the minimum detectable limit to 0.41 mBq/L, and 226Ra activity concentrations from 8.70 to 13.35 mBq/L. For the well water samples, gross α activity concentrations ranged from 0.111 to 0.203 Bq/L, gross β from 0.111 to 0.270 Bq/L, uranium mass concentrations from 2.31 to 13.28 μg/L, thorium mass concentrations from 0.17 to 0.26 μg/L,210Po activity concentrations from 1.03 to 2.12 mBq/L, and 226Ra activity concentrations from 15.38 to 23.63 mBq/L. Conclusion The activity concentrations of natural radionuclides in both well water and tap water in the Hohhot region were at environmental background levels and met national drinking water hygiene standards.
4.Study on Colorimetric Sensor Array Based on Enzymatic Method for Highly Selective Detection of Sarin
Lian-Bo JIANG ; Guo-Hong LIU ; Zhuang-Hu XU ; Jian LI ; Yong-Ling SHEN ; Cai-Xia XU ; Chuan-Qin ZANG ; Yan-Hua XIAO ; Dan-Ping LI ; Ting LIANG
Chinese Journal of Analytical Chemistry 2025;53(5):832-841,中插21-中插23
Sarin(GB)is a typical representative of nerve agents with high toxicity,and very low amount can cause death.GB can cause water and atmospheric environment poisoning,so the detection of GB in water and air is of great significance.In this work,a colorimetric sensor array(CSA)based on GB inhibition of cholinesterase activity was constructed to detect GB with high selectivity.A 4×4 colorimetric array was constructed using acetylcholinesterase(AChE),butyryl cholinesterase(BuChE)and the corresponding substrate acetylthiocholine iodide(S-ACh),butyryl thiocholine iodide(S-BCh),acetylcholine chloride(ACh),butyryl choline chloride(BCh)and 2,6-dichloroindophenol ethyl ester(DCIE).The linear curve of the sensor was Y=131.3×lgC+271.6(R2=0.997),where Y was the array response Euclidean distance,C was the concentration of GB(mg/L),the linear range was 0.03?0.32 mg/L,and the detection limit was 27.6 μg/L.The method could effectively distinguish chemical warfare agents(CWA)such as VX,Soman(GD),mustard gas(HD),Louie reagent(L),and had high anti-interference ability,sensitivity and good repeatability.It was successfully applied to the detection of GB in simulated water and simulated air samples,and the sample recovery rate was 97.2% ?100.9%.This method would be potentially applied to the field rapid detection of nerve agents.
5.Study of Reference Materials for Quantitative Analysis of Gene Copy Numbers of Lentiviral Vectors
Yin-Bo HUO ; Jia-Qi YANG ; Qing TAO ; Wen LIANG ; Li XU ; Lan-Ying LI ; Xiao-Lei ZUO ; Juan YAN ; Min DING ; Ai-Wen MA ; Gang LIU
Chinese Journal of Analytical Chemistry 2025;53(9):1555-1565
Lentiviral vectors(LVs)are key gene delivery tools for integrating target genes into the host genome,but they may also pose risks of insertional mutagenesis.The vector copy number(VCN)in cells is critical for determining the safety of gene modification.However,the reliability and accuracy of its quantification process are influenced by multiple factors.Developing cell reference materials with specific vector copy numbers represents a viable approach to enhance the reliability and consistency of measurement results,enabling quality control of the quantification process and traceability of outcomes.However,the preparation of such reference materials faces challenges in cell sample design,preparation protocols,and advanced quantification techniques.In this study,T lymphocyte cell line Jurkat-based reference materials with LV gene copy numbers of 1 and 2 copy/cell were developed.A high-precision duplex digital polymerase chain reaction(dPCR)method was established to quantify the LV gene and endogenous genes simultaneously.Additionally,the results of dPCR were cross-validated through next-generation sequencing and flow cytometric analysis.Ultimately,confocal microscopy characterization results showed that the developed cell reference materials had intact morphology.The quantification result of VCN-1 was(1.07±0.11)copy/cell,and that of VCN-2 was(2.09±0.21)copy/cell.These cell reference materials demonstrated compliance with stability and homogeneity requirements,and could be applied for quality control throughout the VCN measurement workflow and metrological traceability,improving the accuracy,comparability,and validity of copy number measurements.
6.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Isoliquiritigenin alleviates abnormal endoplasmic reticulum stress induced by type 2 diabetes mellitus
Kai-yi LAI ; Wen-wen DING ; Jia-yu ZHANG ; Xiao-xue YANG ; Wen-bo GAO ; Yao XIAO ; Ying LIU
Acta Pharmaceutica Sinica 2025;60(1):130-140
Isoliquiritigenin (ISL) is a chalcone compound isolated from licorice, known for its anti-diabetic, anti-cancer, and antioxidant properties. Our previous study has demonstrated that ISL effectively lowers blood glucose levels in type 2 diabetes mellitus (T2DM) mice and improves disturbances in glucolipid and energy metabolism induced by T2DM. This study aims to further investigate the effects of ISL on alleviating abnormal endoplasmic reticulum stress (ERS) caused by T2DM and to elucidate its molecular mechanisms.
10.Shaoyaotang Restores Th17/Treg Cell Balance by Regulating Glucose Metabolism Reprogramming in Treatment of Ulcerative Colitis
Yiwen WANG ; Yiling XIA ; Erle LIU ; Shaijin JIANG ; Bo ZOU ; Dongsheng WU ; Youwei XIAO ; Hui CAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):78-85
ObjectiveTo investigate the effect of Shaoyaotang on T helper cell 17/regulatory T lymphocyte(Th17/Treg) cell balance in ulcerative colitis and decipher the intervention mechanism based on glucose metabolism reprogramming. MethodsThe mouse model of ulcerative colitis was established by the dextran sulfate sodium (DSS) method. Forty-eight C57BL/6 mice were randomly allocated into normal, model, Western drug control (mesalazine, 0.39 g·kg-1·d-1), Shaoyaotang (15.54 g·kg-1·d-1), inhibitor (2-deoxy-D-glucose, 2-DG, 100 mg·kg-1·d-1), and inhibitor (2-DG, 100 mg·kg-1·d-1) + Shaoyaotang (15.54 g·kg-1·d-1) groups. Mice were administrated with the corresponding drugs by gavage for 7 days. The general conditions and the colon injury degree were observed 24 h after the last administration. The expression of interleukin (IL)-10 and IL-17 in the colon tissue was detected by immunohistochemical staining. Western blot and Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) were performed to determine the protein and mRNA levels, respectively, of hypoxia-inducing factor-1α (HIF-1α), lactate dehydrogenase (LDHA), and hexokinase 2 (HK2) in the colon tissue. Th17/Treg cell differentiation was detected by flow cytometry. Enzyme-linked immunosorbent assay was employed to measure the levels of lactic acid and glucose in the colon tissue and IL-10, IL-17, and IL-6 in the serum. ResultsCompared with the normal group, the model group showed decreases in body weight and disease activity index (DAI) (P<0.05), elevations in levels of HIF-1α, LDHA, HK2, IL-17, IL-6, Th17 cells, lactic acid, and glucose in the colon tissue (P<0.05), and declines in the levels of of IL-10 and Treg cells (P<0.05). Compared with the model group, the drug administration groups showed increases in body weight and DAI (P<0.05), declines in levels of HIF-1α, LDHA, HK2, IL-17, IL-6, Th17 cells, lactic acid, and glucose in the colon tissue (P<0.05), and rises in levels of IL-10 and Treg cells (P<0.05). Shaoyaotang+2-DG group had the most obvious effect. ConclusionShaoyaotang can relieve diarrhea and bloody stool in mice with ulcerative colitis by restoring the Th17/Treg cell balance via regulation of glucose metabolism reprogramming, thus playing a role in the treatment of ulcerative colitis.


Result Analysis
Print
Save
E-mail