1.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
2.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
3.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
4.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
5.Selection and Weight Determination of Diagnostic Items for Qi Stagnation Syndrome Based on Delphi Method and Analytic Hierarchy Process
Xuan ZHOU ; Ge FANG ; Qingyu MA ; Xiaojuan LI ; Yongxin LI ; Zhixi HU ; Xiantao LI ; Jiaxu CHEN
Journal of Traditional Chinese Medicine 2024;65(21):2211-2216
ObjectiveUsing the Delphi method and analytic hierarchy process (AHP) to screen diagnostic items for qi stagnation syndrome and determine their weights, providing a reference for the development of a diagnostic scale of qi stagnation syndrome. MethodsLiterature related to qi stagnation syndrome were screened from databases including CNKI, Wanfang, VIP, SinoMed (from inception to October 31, 2020). Through systematic review of literature and expert discussions, the information on the four examinations of traditional Chinese medicine were organized and an item pool was constructed. The Delphi method was used to screen the item indicators, while the AHP was employed to determine their weights. Statistical methods such as mean value, full score ratio, rank sum, unimportant percentage, and coefficient of variation were used for item screening, with the weights calculated by AHP serving as the item weights. ResultsA total of 235 articles and books were included for analysis, resulting in an item pool of 16 items. After three rounds of expert consultation, a total of 84 valid questionnaires were collected, with a total expert enthusiasm coefficient of 99% and authority coefficient of 0.86, 0.84, 0.83, respectively, and the coordination coefficients were 0.45, 0.49, and 0.29, respectively. Through the statistics analysis, 8 diagnosis items were screened out, including distension (stuffi-ness) or distending pain or scurrying pain, wiry pulse, depressed emotions, frequent sighing, deep and wiry pulse, irritability, pale red tongue, and thin white coating. The AHP showed that the order of weights of the first-level indicators from high to low was clinical symptoms, pulse manifestation, and tongue manifestation; the order of weights of the second-level indicators from high to low was distension (stuffiness) or distending pain or scurrying pain, wiry pulse, depressed emotions, frequent sighing, deep and wiry pulse, irritability, pale red tongue, and thin white coating. ConclusionBy applying the Delphi method and AHP to analyze and evaluate the diagnostic items for qi stagnation syndrome, key diagnostic items were screened and their weights determined, laying the foundation for the development of a diagnostic scale for qi stagnation syndrome.
6.Expression levels of serum microRNA-1-3p and activating transcription factor 4 in elderly patients with chronic heart failure and their relationships with cognitive impairment
Wenjuan XU ; Huimin WANG ; Juan'e PENG ; Qian HUANG ; Li CHEN ; Liesong CAI
Journal of Clinical Medicine in Practice 2024;28(15):59-63
Objective To explore the expression levels of serum microRNA-1-3p (miR-1-3p) and activating transcription factor 4 (ATF4) in elderly patients with chronic heart failure (CHF) and their relationships with cognitive impairment. Methods A total of 150 elderly patients with CHF were selected as the study subjects. Based on the Montreal Cognitive Assessment (MoCA) score, the patients were divided into cognitive impairment group (
7.Reconstruction points of intrauterine applicator in intracavitary brachytherapy for cervical cancer
Yongfu FENG ; Shaojun CHEN ; Yusong LONG ; Junwen TAN ; Xiantao HE ; Gang LI ; Chengjun FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2024;33(9):825-832
Objective:To evaluate the effect of different reconstruction points of intrauterine applicator on the source dwell positions and plan dosimetry in intracavitary brachytherapy for cervical cancer.Methods:Clinical data of 43 patients with cervical cancer who had completed radical radiotherapy in Liuzhou Workers' Hospital from May 2020 to October 2022 were retrospectively analyzed. Among 43 patients, aged 32-79 years, 40 cases were diagnosed with squamous carcinoma and 3 cases of adenocarcinoma. All patients received external irradiation for 50.4 Gy / 28 fractions and CT-guided intracavitary brachytherapy (45° intrauterine applicator) was 36 Gy / 6 fractions. Brachytherapy was performed by using Fletcher applicator, the curvature of intrauterine applicator were 15°, 30°and45°. Two sets of brachytherapy plans were simulated for each patient. One set of plans extracted the simulated CT positioning images and the original plan of the patient's brachytherapy. The reconstruction point of the curved part of the 45° intrauterine applicator was adjusted to slice-by-slice reconstruction. The plan was optimized to meet clinical requirements according to the prescription, which was called the slice-by-slice group. In the other set of plans, slice-by-slice group was used as a template. The reconstruction points of the curved section of the 45° intrauterine applicator were adjusted to 1, 3, 5, and 7, without modifying the applicator weights and other parameters, which was called the average group 1, 3, 5 and 7. The deviation analysis of 15°, 30° and 45° intrauterine applicator with different number of reconstruction points was carried out, the reconstruction deviation of 45°, 30° and 15° intrauterine applicator at different reconstruction points was compared. Paired-sample t-test or Wilcoxon signed rank test were used to compare the differences in high-risk clinical target volume (HR-CTV) D 50%, D 90%, D 100%, V 100%, V 150%, V 200% and conformity index (CI) as well as D 2 cm3, D 1 cm3 and D 0.1 cm3 in bladder, rectum, and small intestine between two groups of 45° intrauterine applicator. Results:The reconstruction deviation in the average group was mainly from the vertical direction of the 45° intrauterine applicator. The mean reconstruction deviations of 45° (1, 3, 5, 7 reconstruction points), 30° (1, 3, 5 reconstruction points) and 15° (1, 2 reconstruction points) were 1.30 mm, 0.32 mm, 0.14 mm and 0.08 mm; 0.57 mm, 0.14 mm and 0.06 mm; 0.14 mm and 0.06 mm, respectively. There was no significant difference in the parameters of high-risk clinical target volume (HR-CTV) in the slice-by-slice group compared with the average group 5 and 7 (all P>0.005), and no significant difference was found between the average group 5 and 7 (all P>0.005). There were no statistically significant differences in bladder and rectum doses between the slice-by-slice group and the average groups or within the average groups (all P>0.005). The parameters of small intestine in the slice-by-slice group were higher than those of the average group 1, the difference was statistically significant ( P=0.002,<0.001,<0.001). The dose of small intestine in the slice-by-slice group was not statistically significant compared with those in the average group 5 and 7 (both P>0.005). The dose of small intestine in the average group 5 was not statistically significant compared with that in the average group 7 ( P>0.005). The small intestine dose deviations of D 0.1 cm3, D 1 cm3 and D 2 cm3 in the average groups at 1 reconstruction point were 2.41%±1.70%, 1.95%±1.27% and 1.71%±1.10%, respectively. Conclusion:The number of reconstruction points is recommended to be no less than 1, 3 and 5 of the curved part of the 15°, 30°and 45° Fletcher intrauterine applicator, respectively, during intracavitary brachytherapy for cervical cancer.
8.Meta-analysis on Xixian Tongshuan Capsules/Pills combined with western medicine in treating cerebral infarction
Yuqian JIANG ; Linglin ZHANG ; Xinfu LIAN ; Xiantao LI ; Rong XIE ; Yongjun BAI
International Journal of Traditional Chinese Medicine 2023;45(6):755-759
Objective:To systematically evaluate the clinical efficacy and safety of Xixian Tongshuan Capsules/Pills combined with Western medicine in treating cerebral infarction.Methods:All RCTs about Xixian Tongshuan Capsules/Pills combined with Western medicine in treating cerebral infarction were retrieved from CNKI, Wanfang Database, VIP database, PubMed and CBM. The search period was from the database establishment to December 31, 2021. Two researchers independently extracted the basic literature data and evaluated the methodological quality, then used RevMan5.4 software for meta-analysis.Results:Totally 9 articles were included, involving a total of 988 patients, including 505 cases in the observation group and 483 cases in the control group. Meta-analysis showed that the total effective rate of Xixian Tongshuan Capsules/Pills combined with Western medicine in treating cerebral infarction was higher than that of conventional Western medicine [ RR=1.20, 95% CI (1.13, 1.27), P<0.05]. At the same time, the effect of NIHSS score, Barthel score and FIB were better than those of conventional Western medicine [respectively: MD=-3.21, 95% CI (-4.45, -1.97), P<0.05; MD=11.83, 95% CI (10.66, 13.00), P<0.05; MD=-0.95, 95% CI (-1.36, -0.54), P<0.05]. After treatment with Xixian Tongshuan Capsules/Pills combined with Western medicine, the adverse reactions mainly included dizziness, nausea, indigestion, rash, facial blushing, etc. There was no statistically significant difference in safety between the two groups [ RR=1.50, 95% CI (0.75, 3.01), P>0.05]. Conclusions:Under the treatment of conventional Western medicine, the addition of Xixian Tongshuan Capsules/Pills can improve the clinical efficacy of cerebral infarction treatment, effectively improve the symptoms of neurological impairment, improve the ability of daily life, and promote the prognosis and recovery, and without increasing the incidence of adverse reactions. However, large sample and high quality studies are still needed to support the conclusion.
9.Correlation between monitor units and pass rate of plan dose verification in VMAT plan for different cancers
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2023;32(6):546-550
Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.
10.Establishment the Evaluation System of the Diagnostic Scale for Gastrointestinal Qi Stagnation Syndrome
Ge FANG ; Yuquan TAN ; Xingyu FAN ; Siyuan HU ; Fei WANG ; Jiaxu CHEN ; Xiantao LI ; Zhixi HU
World Science and Technology-Modernization of Traditional Chinese Medicine 2023;25(10):3377-3383
Objective To establish a preliminary evaluation system for gastrointestinal qi stagnation syndrome.Methods On the basis of the systematic evaluation of medical literature in the early stage of the research group,24 high-frequency items were subjected to Delphi method,the item indexes were determined through three rounds of expert consultation,and the proportion value of the indexes was determined by AHP,and the evaluation system of gastrointestinal qi stagnation syndrome was initially constructed.Results A total of 84 valid questionnaires were collected by three rounds of Delphi method,including 15 in the first round,32 in the second round and 37 in the third round.According to the statistics,16 items including distention(stuffy)or distending pain or moving pain(epigastric,abdominal,etc.),belching,borborygmus,flatus,etc.were selected.The order of the proportion of the first level indexes obtained by the analytic hierarchy process from high to low is:clinical symptoms,pulse,tongue;The proportion of secondary indicators from high to low is as follows:distention(stuffy)or distending pain or moving pain(epigastric,abdominal,etc.),pulse string,greasy fur,thin white fur,slippery pulse string,pulse sinking string,light red tongue,flatus,borborygmus,belching,induced or aggravated in case of emotional distress,hiccup,abdominal mass,anorexia,vomiting,belching and swallowing acid.Conclusion Delphi method and analytic hierarchy process have been used to study gastrointestinal qi stagnation syndrome,and an evaluation system has been preliminarily formed.The index structure is reasonable,targeted and has strong clinical practicability.


Result Analysis
Print
Save
E-mail