1.Small bowel video keyframe retrieval based on multi-modal contrastive learning.
Xing WU ; Guoyin YANG ; Jingwen LI ; Jian ZHANG ; Qun SUN ; Xianhua HAN ; Quan QIAN ; Yanwei CHEN
Journal of Biomedical Engineering 2025;42(2):334-342
Retrieving keyframes most relevant to text from small intestine videos with given labels can efficiently and accurately locate pathological regions. However, training directly on raw video data is extremely slow, while learning visual representations from image-text datasets leads to computational inconsistency. To tackle this challenge, a small bowel video keyframe retrieval based on multi-modal contrastive learning (KRCL) is proposed. This framework fully utilizes textual information from video category labels to learn video features closely related to text, while modeling temporal information within a pretrained image-text model. It transfers knowledge learned from image-text multimodal models to the video domain, enabling interaction among medical videos, images, and text data. Experimental results on the hyper-spectral and Kvasir dataset for gastrointestinal disease detection (Hyper-Kvasir) and the Microsoft Research video-to-text (MSR-VTT) retrieval dataset demonstrate the effectiveness and robustness of KRCL, with the proposed method achieving state-of-the-art performance across nearly all evaluation metrics.
Humans
;
Video Recording
;
Intestine, Small/diagnostic imaging*
;
Machine Learning
;
Image Processing, Computer-Assisted/methods*
;
Algorithms
2.18F-FDG PET/CT metabolic parameters for prediction of treatment response to neoadjuvant immunochemotherapy in locally advanced gastric cancer
Peng LI ; Shuang LU ; Weiwei ZHAO ; Yanmei LI ; Xianhua HAN ; Xiaofeng ZHANG ; Jianwei YANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(11):648-653
Objective:To investigate the value of midtreatment 18F-FDG PET/CT metabolic parameters for predicting the pathological response in patients with locally advanced gastric cancer (LAGC) after neoadjuvant immunochemotherapy (NICT). Methods:Twenty-five LAGC patients (19 males, 6 females, age: (64.8±8.6) years) who underwent 18F-FDG PET/CT after NICT in Henan Cancer Hospital from August 2019 to June 2024 were retrospectively analyzed. The lesion′s ROI was delineated, then the SUV max and metabolic tumor volume (MTV) were measured, and the SUV max was divided by SUV mean of the descending aorta to obtain the tumor-to-background ratio (TBR). Patients underwent surgery after PET/CT imaging. Based on the tumor regression grade (TRG) system by the American Joint Committee on Cancer (AJCC) criteria on surgical specimen, patients were divided into responders (TRG0+ 1) and non-responders (TRG2+ 3). Independent-sample t test, Mann-Whitney U test, one-way analysis of variance, and Kruskal-Wallis rank-sum test were used to compare the differences of data. The predictive efficacy of PET/CT metabolic parameters was assessed by the ROC curve analysis. Results:Postsurgical pathology showed that 9 patients were responders and 16 were non-responders. The SUV max (3.10±1.95) and TBR (2.44±1.54) of primary lesions in responders were lower than those in non-responders (7.40±4.68, 5.85±3.74; t values: -2.61, -2.59, both P<0.05), while the MTV of primary tumors and short diameter and metabolic parameters of positive lymph nodes were not significantly different between those 2 groups ( t=-1.50, Z values: -1.09 to -0.75, all P>0.05). No significant relation was found between PET/CT parameters and pathological differentiation or Lauren classification, or other pathological features ( t values: -1.55 to 1.38, Z values: -1.84 to 0, F values: 0.12-2.43, H values: 0.13-0.98, all P>0.05). ROC curve showed that the cut-off value of SUV max for predicting postoperative TRG was 5.40, and the AUC reached 0.77 (95% CI: 0.56-0.91), with the sensitivity and specificity of 9/16, 9/9, respectively. With TBR=3.54 as the cut-off value, its AUC reached 0.77 (95% CI: 0.56-0.91), and the sensitivity and specificity were 11/16, 8/9, respectively. The sensitivity and specificity of PET/CT for predicting lymph node positivity of patients were 8/12 and 13/13, respectively. Conclusion:Interim 18F-FDG PET/CT metabolic parameters can accurately predict the pathological response of LAGC patients after NICT.
3.Value of cranial CT cisternal grading,D-dimer,and Glasgow Coma Scale score in predicting short-term postoperative prognosis in patients with severe traumatic brain injury
Liexiang ZHANG ; Yuchao HE ; Chang CAI ; Xianhua FU ; Meng LI ; Jin XU ; Ning JIANG ; Xiefeng WANG ; Honglin CHEN
Journal of Clinical Medicine in Practice 2025;29(8):17-21
Objective To investigate the value of cranial CT cisternal grading combined with D-dimer(D-D)and Glasgow Coma Scale(GCS)score in predicting the short-term postoperative prog-nosis of patients with severe traumatic brain injury.Methods A total of 165 patients with severe trau-matic brain injury who were treated in the hospital from January 2019 to May 2024 were selected as study subjects,all underwent craniotomy surgery.Postoperative follow-up was conducted for 3 months to analyze the differences in clinical data and preoperative indicators such as cranial CT cisternal grad-ing,D-D levels,and GCS scores between patients with poor and good prognosis.The value of cranial CT cisternal grading,D-D levels,and GCS scores in predicting short-term postoperative poor prognosis in patients with severe traumatic brain injury was also analyzed.Results Compared with patients with good prognosis,patients with poor prognosis had higher proportion of age,cranial CT cisternal grading of Ⅰ to Ⅱ,D-D levels,and GCS scores<6(P<0.05).There were no statistically significant differences in C-reactive protein,prothrombin time,activated partial thromboplastin time,international normalized ratio,total cholesterol,triglycerides,high-density lipoprotein cholesterol,and low-density lipoprotein cholesterol levels between patients with poor and good prognosis(P>0.05).Cranial CT cisternal grading,D-D levels,and GCS scores were influencing factors for short-term postoperative poor prognosis in patients with severe traumatic brain injury(P<0.05).The area under the curve for poor prognosis by three indicators in combination was 0.941(95%CI,0.906 to 0.975),which was higher than the area under the curve for the individual predictions of cranial CT cisternal grad-ing,D-D levels,and GCS scores(P<0.05).Conclusion The influencing factors for short-term postoperative prognosis in patients with severe traumatic brain injury include cranial CT cisternal grading,D-D levels,and GCS scores.The model based on these three indicators has certain appli-cation value in predicting patient prognosis.
4.Consistency verification of reverse screening strategy for syphilis in maternal and child populations and assocliation between S/CO value and false positive rate of CLIA
Weiming LU ; Jiewen LI ; Chunming GU ; Junfei GUO ; Kefeng LAI ; Xianhua ZHENG ; Mingyong LUO
The Journal of Practical Medicine 2025;41(20):3249-3255
Objective To compare the diagnostic performance of two syphilis reverse testing protocols recommended by the U.S.Centers for Disease Control and Prevention(USCDC)and the European Centre for Disease Prevention and Control(ECDC)within maternal and child populations,and to explore the factors contributing to false-positive results in chemiluminescent immunoassays(CLIA).Methods A retrospective analysis was performed on serological test results from 109,003 patients collected between 2021 and 2023.All participants were initially screened for specific syphilis antibodies using CLIA,and those with positive results underwent confirmatory testing with both the toluidine red unheated serum test(TRUST)and the Treponema pallidum particle agglutination assay(TPPA).The kappa statistic was employed to assess the diagnostic agreement between the USCDC and ECDC protocols,while also analyzing the distribution patterns of CLIA false-positive results across varying S/CO value ranges and demographic groups.Results Both protocols achieved a syphilis positivity rate of 0.34%.The hospital's high-prevalence syphilis screening program identified no cases with CLIA-positive or TRUST-positive but TPPA-negative results,suggesting high specificity in this population.The two protocols demonstrated perfect agreement with a Kappa value of 1.0,indicating no significant difference in diagnostic performance between maternal and child populations.CLIA exhibited a true positive rate of 71.04%,which was positively correlated with S/CO values:21.88%when 1.010.The highest false positive rate for CLIA(38.75%)was observed among young adults,while the largest proportion of false positives-reaching 40.00%—was associated with pregnancy and abortion status.Conclusions The two reverse detection methods for syphilis exhibit comparable diagnostic efficacy in women and children from populations with low syphilis prevalence.CLIA demonstrates high sensitivity;however,when the S/CO ratio is less than 10,particularly in adult women of childbearing age,clinicians should remain vigilant for potential false-positive results to prevent misdiagnosis and unnecessary medical interventions.
5.Dynamic analysis of immune responses in heterotopic heart transplantation model of genetically modified pig-to-macaque
Le BAI ; Ziqiang DAI ; Zhipeng REN ; Chenghong LAI ; Xianhua LI ; Xiaoyang XIE ; Dengke PAN ; Enwu LONG ; Dianyuan LI
Organ Transplantation 2025;16(5):747-755
Objective To evaluate the efficacy of a combined immunosuppression regimen in modulating rejection in genetically modified pig-to-macaque xenogeneic heart transplantation.Methods Two xenogeneic heart transplantation models were constructed using genetically modified pigs and macaques.Dynamic monitoring of recipient peripheral blood immune parameters and observation of graft pathological changes were performed.Results Regimen 1,featuring B-cell depletion,T-cell inhibition,and C3 complement suppression,reduced lymphocyte levels but failed to control acute humoral rejection and macrophage infiltration.Regimen 2,adding C5 complement inhibition and interleukin-6 inhibition to Regimen 1,more effectively lowered lymphocyte levels,inhibited acute humoral rejection and complement activation,and decreased antibody deposition.However,a late-phase cytokine storm and residual T cells emerged.Conclusions Regimen 2 reduces the hyperacute and acute rejection risks through multi-target intervention.Yet,it requires balancing medication complexity and safety.This indicates the need to optimize cellular immune regulation and adjust the plan through dynamic multidimensional monitoring.
6.18F-FDG PET/CT metabolic parameters for prediction of treatment response to neoadjuvant immunochemotherapy in locally advanced gastric cancer
Peng LI ; Shuang LU ; Weiwei ZHAO ; Yanmei LI ; Xianhua HAN ; Xiaofeng ZHANG ; Jianwei YANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(11):648-653
Objective:To investigate the value of midtreatment 18F-FDG PET/CT metabolic parameters for predicting the pathological response in patients with locally advanced gastric cancer (LAGC) after neoadjuvant immunochemotherapy (NICT). Methods:Twenty-five LAGC patients (19 males, 6 females, age: (64.8±8.6) years) who underwent 18F-FDG PET/CT after NICT in Henan Cancer Hospital from August 2019 to June 2024 were retrospectively analyzed. The lesion′s ROI was delineated, then the SUV max and metabolic tumor volume (MTV) were measured, and the SUV max was divided by SUV mean of the descending aorta to obtain the tumor-to-background ratio (TBR). Patients underwent surgery after PET/CT imaging. Based on the tumor regression grade (TRG) system by the American Joint Committee on Cancer (AJCC) criteria on surgical specimen, patients were divided into responders (TRG0+ 1) and non-responders (TRG2+ 3). Independent-sample t test, Mann-Whitney U test, one-way analysis of variance, and Kruskal-Wallis rank-sum test were used to compare the differences of data. The predictive efficacy of PET/CT metabolic parameters was assessed by the ROC curve analysis. Results:Postsurgical pathology showed that 9 patients were responders and 16 were non-responders. The SUV max (3.10±1.95) and TBR (2.44±1.54) of primary lesions in responders were lower than those in non-responders (7.40±4.68, 5.85±3.74; t values: -2.61, -2.59, both P<0.05), while the MTV of primary tumors and short diameter and metabolic parameters of positive lymph nodes were not significantly different between those 2 groups ( t=-1.50, Z values: -1.09 to -0.75, all P>0.05). No significant relation was found between PET/CT parameters and pathological differentiation or Lauren classification, or other pathological features ( t values: -1.55 to 1.38, Z values: -1.84 to 0, F values: 0.12-2.43, H values: 0.13-0.98, all P>0.05). ROC curve showed that the cut-off value of SUV max for predicting postoperative TRG was 5.40, and the AUC reached 0.77 (95% CI: 0.56-0.91), with the sensitivity and specificity of 9/16, 9/9, respectively. With TBR=3.54 as the cut-off value, its AUC reached 0.77 (95% CI: 0.56-0.91), and the sensitivity and specificity were 11/16, 8/9, respectively. The sensitivity and specificity of PET/CT for predicting lymph node positivity of patients were 8/12 and 13/13, respectively. Conclusion:Interim 18F-FDG PET/CT metabolic parameters can accurately predict the pathological response of LAGC patients after NICT.
7.Consistency verification of reverse screening strategy for syphilis in maternal and child populations and assocliation between S/CO value and false positive rate of CLIA
Weiming LU ; Jiewen LI ; Chunming GU ; Junfei GUO ; Kefeng LAI ; Xianhua ZHENG ; Mingyong LUO
The Journal of Practical Medicine 2025;41(20):3249-3255
Objective To compare the diagnostic performance of two syphilis reverse testing protocols recommended by the U.S.Centers for Disease Control and Prevention(USCDC)and the European Centre for Disease Prevention and Control(ECDC)within maternal and child populations,and to explore the factors contributing to false-positive results in chemiluminescent immunoassays(CLIA).Methods A retrospective analysis was performed on serological test results from 109,003 patients collected between 2021 and 2023.All participants were initially screened for specific syphilis antibodies using CLIA,and those with positive results underwent confirmatory testing with both the toluidine red unheated serum test(TRUST)and the Treponema pallidum particle agglutination assay(TPPA).The kappa statistic was employed to assess the diagnostic agreement between the USCDC and ECDC protocols,while also analyzing the distribution patterns of CLIA false-positive results across varying S/CO value ranges and demographic groups.Results Both protocols achieved a syphilis positivity rate of 0.34%.The hospital's high-prevalence syphilis screening program identified no cases with CLIA-positive or TRUST-positive but TPPA-negative results,suggesting high specificity in this population.The two protocols demonstrated perfect agreement with a Kappa value of 1.0,indicating no significant difference in diagnostic performance between maternal and child populations.CLIA exhibited a true positive rate of 71.04%,which was positively correlated with S/CO values:21.88%when 1.010.The highest false positive rate for CLIA(38.75%)was observed among young adults,while the largest proportion of false positives-reaching 40.00%—was associated with pregnancy and abortion status.Conclusions The two reverse detection methods for syphilis exhibit comparable diagnostic efficacy in women and children from populations with low syphilis prevalence.CLIA demonstrates high sensitivity;however,when the S/CO ratio is less than 10,particularly in adult women of childbearing age,clinicians should remain vigilant for potential false-positive results to prevent misdiagnosis and unnecessary medical interventions.
8.Dynamic analysis of immune responses in heterotopic heart transplantation model of genetically modified pig-to-macaque
Le BAI ; Ziqiang DAI ; Zhipeng REN ; Chenghong LAI ; Xianhua LI ; Xiaoyang XIE ; Dengke PAN ; Enwu LONG ; Dianyuan LI
Organ Transplantation 2025;16(5):747-755
Objective To evaluate the efficacy of a combined immunosuppression regimen in modulating rejection in genetically modified pig-to-macaque xenogeneic heart transplantation.Methods Two xenogeneic heart transplantation models were constructed using genetically modified pigs and macaques.Dynamic monitoring of recipient peripheral blood immune parameters and observation of graft pathological changes were performed.Results Regimen 1,featuring B-cell depletion,T-cell inhibition,and C3 complement suppression,reduced lymphocyte levels but failed to control acute humoral rejection and macrophage infiltration.Regimen 2,adding C5 complement inhibition and interleukin-6 inhibition to Regimen 1,more effectively lowered lymphocyte levels,inhibited acute humoral rejection and complement activation,and decreased antibody deposition.However,a late-phase cytokine storm and residual T cells emerged.Conclusions Regimen 2 reduces the hyperacute and acute rejection risks through multi-target intervention.Yet,it requires balancing medication complexity and safety.This indicates the need to optimize cellular immune regulation and adjust the plan through dynamic multidimensional monitoring.
9.Analysis of cardiovascular disease prevention indicators among residents with intra-urban migration in Central China
HUANG Tianshu ; TIAN Yuan ; ZHANG Xingyi ; LI Chenhui ; ZHAO Yun ; ZHAO Dongyuan ; CHEN Xianhua ; ZHU Mengyao ; JIAO Guanqi ; GUO Dongmin ; LI Xi ; CUI Jianlan
Journal of Preventive Medicine 2024;36(5):451-456
Objective:
To investigate cardiovascular disease (CVD) prevention status among residents with intra-urban migration in Central China, so as to provide insights into targeted prevention and control of CVD.
Methods:
Basic data of residents aged 35 to 75 years who participated in Early Screening and Comprehensive Intervention Project for CVD high-risk populations in Central China from September 2015 to August 2020 were collected. According to birth place, type of registered residence and current residence, residents were divided into four groups: local residents in old urban area, local residents in new urban area, other urban migrants and other rural migrants. The status of CVD primary and secondary prevention, were analysed by using a robust Poisson regression model.
Results:
A total of 76 513 residents were recruited, including 29 420 males (38.45%) and 47 093 females (61.55%), and had a mean age of (56.36±9.84) years. There were 45 087 (58.93%) local residents in old urban area, 23 868 (31.19%) local residents in new urban area, 5 668 (7.41%) other urban migrants and 1 890 (2.47%) other rural migrants. After adjusting for variables such as age, gender and educational level, the results of robust Poisson regression analysis showed that compared with local residents in old urban area, local residents in new urban area had lower compliance rates of non- or moderate-drinking (RR=0.987, 95%CI: 0.975-1.000) and healthy diet (RR=0.535, 95%CI: 0.365-0.782), lower proportion of using aspirin as primary prevention in CVD high-risk population (RR=0.616, 95%CI: 0.511-0.741), lower awareness (RR=0.873, 95%CI: 0.782-0.974) and control rates (RR=0.730, 95%CI: 0.627-0.849) of hypertension; other urban migrants had higher compliance rate of non-smoking (RR=1.045, 95%CI: 1.017-1.075); other rural migrants had lower proportion of using aspirin as primary prevention in CVD high-risk population (RR=0.826, 95%CI: 0.707-0.966).
Conclusion
The CVD primaryprevention among local residents in new urban area is relatively poor among four groups of residents in Central China, and key interventions are needed.
10.Development of an Integrated Disposable Device for SARS-CoV-2 Nucleic Acid Extraction and Detection
Ma JING ; Hao YANZHE ; Hou MEILING ; Zhang XIAOSHAN ; Liu JINGDUAN ; Meng HAODI ; Chang JIANGBO ; Ma XUEJUN ; Liu JIHUA ; Ying QINGJIE ; Wang XIANHUA ; Li HONGXIA ; Cao YUXI ; Zhang XIAOGUANG
Biomedical and Environmental Sciences 2024;37(6):639-646
Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2). Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated. Results The precision of the syringe transfer volume was 19.2±1.9 μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0 ℃(set value was 60)and 95.1±0.2 ℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×106 copies/mL,while a commercial kit yielded 2.98×106 copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL. Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT).


Result Analysis
Print
Save
E-mail