1.Structural Design and Experimental Study of a New Aerodynamic Electric Hook
Cao LIU ; Junwei HUANG ; Haidong LIAO ; Jiale YUAN ; Yang XIE ; Jiafeng LIU ; Yong YING ; Xiangtai ZENG ; Cong LIAO
Chinese Journal of Minimally Invasive Surgery 2025;25(10):628-635
Objective To investigate the safety parameters of the air-powered electrocautery hook and its advantages in laparoscopic surgery.Methods In pressure trauma experiments,21 healthy New Zealand White Rabbits were randomly divided into three groups.In each group,three sites(liver,intestine,and kidney)were selected from each rabbit,and the air-powered electrocautery hook was used under laparoscopy to apply pressure and time gradients in a cross-combination manner.The three groups of experimental rabbits were dissected at three time points:immediately after application,3 d post-application,and 7 d post-application.Pathological sections were prepared from the corresponding treated sites,and the extent of injury was assessed.In rabbit renal capsule removal experiment,another 20 healthy New Zealand White Rabbits were randomly divided into 2 groups.Renal capsule removal was performed by using an air-powered electrosurgical hook and a conventional electrosurgical hook,respectively,to compare the two groups in terms of surgical time,intraoperative bleeding volume,intraoperative complications,and the number of times of wiping speculum.Results In pressure trauma experiment,except for the intestinal tract at 3 seconds(P=0.060),the histopathological scores under 0.3 MPa pressure were significantly higher than those under 0.1 MPa(P<0.05)and 0.2 MPa(P<0.05)in all the tissues.In the tissue sampling groups at 3 d and 7 d post-surgery,no tissue damage was observed in any tissue at any time point under 0.1 MPa pressure.In rabbit renal capsule removal experiment,the aerodynamic electrocautery group had less intraoperative bleeding volume than the conventional electrocautery group[(2.9±0.5)ml vs.(3.4±0.5)ml,t=-2.280,P=0.035].There were no significant differences between the two groups in terms of surgical time,intraoperative complication rates,and the number of times of wiping speculum(P>0.05).Conclusions The safe pressure range for using the air-powered electrosurgical hook on the surfaces of the kidney and intestinal tract is within 0.2 MPa.Within the safe pressure range,blowing on tissue for 6 seconds or less is relatively safe.Using the air-powered electrosurgical hook in surgeries requiring the separation of loose connective tissue can reduce intraoperative bleeding.
2.Structural Design and Experimental Study of a New Aerodynamic Electric Hook
Cao LIU ; Junwei HUANG ; Haidong LIAO ; Jiale YUAN ; Yang XIE ; Jiafeng LIU ; Yong YING ; Xiangtai ZENG ; Cong LIAO
Chinese Journal of Minimally Invasive Surgery 2025;25(10):628-635
Objective To investigate the safety parameters of the air-powered electrocautery hook and its advantages in laparoscopic surgery.Methods In pressure trauma experiments,21 healthy New Zealand White Rabbits were randomly divided into three groups.In each group,three sites(liver,intestine,and kidney)were selected from each rabbit,and the air-powered electrocautery hook was used under laparoscopy to apply pressure and time gradients in a cross-combination manner.The three groups of experimental rabbits were dissected at three time points:immediately after application,3 d post-application,and 7 d post-application.Pathological sections were prepared from the corresponding treated sites,and the extent of injury was assessed.In rabbit renal capsule removal experiment,another 20 healthy New Zealand White Rabbits were randomly divided into 2 groups.Renal capsule removal was performed by using an air-powered electrosurgical hook and a conventional electrosurgical hook,respectively,to compare the two groups in terms of surgical time,intraoperative bleeding volume,intraoperative complications,and the number of times of wiping speculum.Results In pressure trauma experiment,except for the intestinal tract at 3 seconds(P=0.060),the histopathological scores under 0.3 MPa pressure were significantly higher than those under 0.1 MPa(P<0.05)and 0.2 MPa(P<0.05)in all the tissues.In the tissue sampling groups at 3 d and 7 d post-surgery,no tissue damage was observed in any tissue at any time point under 0.1 MPa pressure.In rabbit renal capsule removal experiment,the aerodynamic electrocautery group had less intraoperative bleeding volume than the conventional electrocautery group[(2.9±0.5)ml vs.(3.4±0.5)ml,t=-2.280,P=0.035].There were no significant differences between the two groups in terms of surgical time,intraoperative complication rates,and the number of times of wiping speculum(P>0.05).Conclusions The safe pressure range for using the air-powered electrosurgical hook on the surfaces of the kidney and intestinal tract is within 0.2 MPa.Within the safe pressure range,blowing on tissue for 6 seconds or less is relatively safe.Using the air-powered electrosurgical hook in surgeries requiring the separation of loose connective tissue can reduce intraoperative bleeding.
3.Clinical effectiveness of endoscopic thyroidectomy via transoral submental approach vs.open surgery:a comparative study
Huilin LUO ; Mengqiao DAI ; Cao LIU ; Zhener LI ; Yang XIE ; Yong YING ; Xiangtai ZENG
The Journal of Practical Medicine 2024;40(3):384-388
Objective To compare endoscopic thyroidectomy via transoral submental approach with open surgery for treating thyroid tumors in terms of the clinical effectiveness.Methods We retrospectively reviewed and analyzed the clinical data and follow-up records of 154 patients in the study,who were hospitalized for thyroidectomy in our hospital from January 2021 to June 2022.Among them,74 cases undergoing endoscopic thyroidectomy via transoral submental approach were assigned to the endoscopic group and 80 cases undergoing traditional open thyroid surgery to the open surgery group.Results All operations were completed successfully and safely in both groups,with no intermediate openings in the endoscopic group.Compared with the open surgery group,the endoscopic group had significantly fewer intraoperative blood losses[(19.46±10.24)mL vs.(32.05±15.87)mL],significantly less incision length[(1.95±0.30)cm vs.(7.05±0.60)cm],significant shorter operative time[(136.66±22.44)min vs.(82.75±15.20)min],and significantly less total postoperative drainage[(111.35±38.92)mL vs.(95.45±36.73)mL](all P<0.05).Endoscopic patients had superior postoperative pain and cosmetic satisfaction compared to open patients,and the difference was statistically significant(P<0.05).The two groups had no significant differences in the number of lymph node dissections,parathyroid hormone,and postoperative morbidity between the two groups(P>0.05).Conclusion The endoscopic thyroidectomy via transoral submental approach can achieve the same clinical effectiveness as the traditional open surgery.However,it is advantageous in reducing intra-operative blood loss,relieving post-operative pain,and achieving a better cosmetic effects of neck incision,thus deserving clinical promotion and application.
4.Application of a New Type Non-inflatable Retractor in Transoral Endoscopic Thyroidectomy via Submental and Vestibular Approach
Zhiqiang JIANG ; Mengqiao DAI ; Zihang AI ; Huilin LUO ; Cong LIAO ; Yang XIE ; Yong YING ; Xiangtai ZENG
Chinese Journal of Minimally Invasive Surgery 2024;24(8):534-539
Objective To investigate the safety of using a self-made new type non-inflatable retractor for transoral endoscopic thyroidectomy via submental and vestibular approach(TOETSMVA).Methods A retrospective analysis was conducted on the surgical records of 119 cases of unilateral thyroid lobe tumor from January 2021 to June 2022.Among them,37 cases underwent non-inflatable TOETSMVA by using a new type non-inflatable retractor(non-inflatable group),37 cases underwent traditional inflatable TOETSMVA(inflatable group),and 45 cases underwent traditional open anterior cervical thyroid surgery(open group).The differences in surgical indicators,postoperative complications,and patient satisfaction with incision were compared among the three groups.Results Compared with the open group,the non-inflatable group had longer operation time[(131.0±20.1)min vs.(81.1±15.7)min,P=0.000],but less intraoperative blood loss[19(15,27)ml vs.30(25,37)ml,P=0.000],lower pain score on the first day after surgery[(4.8±2.1)points vs.(6.4±1.9)points,P=0.000],and higher patient's satisfaction with the incision(the number of cases of very dissatisfied,dissatisfied,satisfied,comparatively satisfied,and very satisfied were 0,0,6,16,15 vs.4,3,19,17,2,P=0.000).Compared with the inflatable group,the non-inflatable group had shorter surgical time[(131.0±20.1)min vs.(141.8±22.9)min,P=0.019],and there were no statistically significant differences in intraoperative bleeding volume,pain score on the first day after surgery,and patient satisfaction with the incision(P>0.05).There were no statistically significant differences in the number of lymph node dissection,total postoperative drainage volume,and parathyroid hormone(PTH)levels on the first day after surgery among the three groups(P>0.05).Postoperative bleeding occurred in 1 case in the open group,and 1 case of hoarseness and 1 case of subcutaneous ecchymosis of the neck were noted in the non-inflatable group.No tracheoesophageal injury,severe subcutaneous emphysema,hypercapnia,or gas embolism happened among the three groups.Conclusions The new type non-inflatable retractor can effectively maintain space during TOETSMVA surgery.Compared with traditional open anterior cervical thyroid surgery and conventional inflatable TOETSMVA,it has better surgical safety.
5.Value of MRI in the diagnosis of complex congenital heart disease
Yanhai CUI ; Changhong LIANG ; Meiping HUANG ; Hui LIU ; Xiangtai YANG
Clinical Medicine of China 2012;28(7):689-691
Objective To evaluate the value of MRI in the diagnosis of complex congenital heart disease.Methods Twenty-one patients with complex congenital heart disease,who had undergone MRI examination were enrolled in this research.The MRI data of every patient was analyzed and abnormalities of anatomy was counted by two experienced cardiovascular radiologist.Surgical diagnosis (17 cases) or consistent diagnosis (4 cases) of ultrasonic,cardiac catheter and cardiac CT was regarded as reference standards.Accuracy and misdiagnosis rate were obtained.Results Twenty-one patients had 63 main abnormalities,61 malformations was found by MRI examination,the diagnostic accuracy was 96.8%,and the misdiagnosis rate was 4.8% (1 atrial septal defect (ASD) and 1 major aorta pulmonary collateral arteries (MAPCAS) were missed,1 arterialduct stump was misdiagnosed as patent ductus arteriosus (PDA).Conclusion MRI has excellent diagnosticaccuracy on complex congenital heart disease,it is another good noninvasive cardiac examination method beside ultrasonic.

Result Analysis
Print
Save
E-mail