1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Csde1 Mediates Neurogenesis via Post-transcriptional Regulation of the Cell Cycle.
Xiangbin JIA ; Wenqi XIE ; Bing DU ; Mei HE ; Jia CHEN ; Meilin CHEN ; Ge ZHANG ; Ke WANG ; Wanjing XU ; Yuxin LIAO ; Senwei TAN ; Yongqing LYU ; Bin YU ; Zihang ZHENG ; Xiaoyue SUN ; Yang LIAO ; Zhengmao HU ; Ling YUAN ; Jieqiong TAN ; Kun XIA ; Hui GUO
Neuroscience Bulletin 2025;41(11):1977-1990
Loss-of-function variants in CSDE1 have been strongly linked to neuropsychiatric disorders, yet the precise role of CSDE1 in neurogenesis remains elusive. In this study, we demonstrate that knockout of Csde1 during cortical development in mice results in impaired neural progenitor proliferation, leading to abnormal cortical lamination and embryonic lethality. Transcriptomic analysis revealed that Csde1 upregulates the transcription of genes involved in the cell cycle network. Applying a dual thymidine-labelling approach, we further revealed prolonged cell cycle durations of neuronal progenitors in Csde1-knockout mice, with a notable extension of the G1 phase. Intersection with CLIP-seq data demonstrated that Csde1 binds to the 3' untranslated region (UTR) of mRNA transcripts encoding cell cycle genes. Particularly, we uncovered that Csde1 directly binds to the 3' UTR of mRNA transcripts encoding Cdk6, a pivotal gene in regulating the transition from the G1 to S phases of the cell cycle, thereby maintaining its stability. Collectively, this study elucidates Csde1 as a novel regulator of Cdk6, sheds new light on its critical roles in orchestrating brain development, and underscores how mutations in Csde1 may contribute to the pathogenesis of neuropsychiatric disorders.
Animals
;
Neurogenesis/genetics*
;
Cell Cycle/genetics*
;
Mice, Knockout
;
Mice
;
Neural Stem Cells/metabolism*
;
DNA-Binding Proteins/metabolism*
;
Cyclin-Dependent Kinase 6/genetics*
;
Cell Proliferation
;
3' Untranslated Regions
;
Cerebral Cortex/embryology*
;
RNA-Binding Proteins
;
Mice, Inbred C57BL
6.Early outcome of balloon-expandable valves in the treatment of severe aortic stenosis: A single-center study
Yihang LI ; Jingnan ZHANG ; Fang FANG ; Junyi WAN ; Liang XU ; Xiangbin PAN ; Gejun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(07):1007-1013
Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. Conclusion The use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.
7.Multicenter expert recommendations on interventional valve-in-valve technology for mitral bioprosthetic valve destruction in China
Haibo ZHANG ; Xiangbin PAN ; Yingqiang GUO ; Lai WEI ; Jian YANG ; Daxin ZHOU ; Yongjian WU ; Xu MENG ; Liming LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(08):1090-1095
Mitral valve replacement is one of the most common heart valve surgeries in China. In recent years, with the increase in degenerative valve diseases, older patients, and the progress of anti-calcification technology of biological valves, the proportion of mitral valve biological valve replacement has been increasing year by year. After the damage of traditional mitral valve biological valves, re-operation of valve replacement with thoracotomy is required. However, the adhesion between the heart and sternum, as well as the damage caused by cardiopulmonary bypass and cardiac arrest, can cause significant trauma to elderly patients and those with multiple organ dysfunction, leading to increased mortality and complication rates. In recent years, interventional valve surgery, especially transcatheter valve-in-valve surgery, has developed rapidly. This procedure can correct the damaged mitral valve function without stopping the heart, but there are still many differences between its technical process and conventional aortic valve replacement surgery. Therefore, organizing and writing multicenter expert recommendations on the technical process of transcatheter valve-in-valve surgery for damaged mitral valve biological valves is of great significance for the training and promotion of this technology.
8.In vitro bench testing using patient-specific 3D models for percutaneous pulmonary valve implantation with Venus P-valve
Yu HAN ; Zehua SHAO ; Zirui SUN ; Yan HAN ; Hongdang XU ; Shubo SONG ; Xiangbin PAN ; De Jaegere Peter P. T. ; Taibing FAN ; Gejun ZHANG
Chinese Medical Journal 2024;137(8):990-996
Background::Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. Methods::Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University.Results::3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) ( n = 2) or risk of compression coronary artery ( n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). Conclusions::In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.
9.Contrast-zero ultrasound-guided transcatheter aortic valve replacement: A case report
Jie DONG ; Wenbin OUYANG ; Zefu LI ; Fengwen ZHANG ; Donghui XU ; Jiande WANG ; Yongquan XIE ; Xiaopeng HU ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(02):320-324
Conventional transcatheter aortic valve replacement is normally recommended with transthoracic echocardiography, and contrast agent mediated fluoroscopy under anesthesia to guide a better implantation of the transcatheter valve. However, iodine-containing contrast agent possibly damages the patient’s kidney, and even induces the acute kidney injury. We reported a 75-year-old patient diagnosed with severe aortic valve stenosis, moderate regurgitation, and chronic renal failure. We performed the aortic valve replacement under the guidance of fluoroscopy and transesophageal ultrasound without contrast agent. Seven days after surgery, the patient recovered well and discharged with alleviated aortic stenosis and fixed transcatheter aortic valve.
10.Preliminary analysis of subclinical leaflet thrombosis after percutaneous aortic valve replacement with balloon dilation
Yihang LI ; Jingnan ZHANG ; Fang FANG ; Junyi WAN ; Liang XU ; Xiangbin PAN ; Gejun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(03):410-415
Objective To analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.

Result Analysis
Print
Save
E-mail